SOMATOM go.Sim How to Evaluate Topogram and Check for Straightness Job Aid
In Radiation Therapy, patient positioning is paramount. The patient's position in the simulator CT room is the same as the patient's position in the treatment room. Patient position can also affect treatment beam directions..
How to Evaluate Topogram and Check for Straightness Applicable for the following systems for VA40 software. SOMATOM go.Open Pro SOMATOM go.Sim SOMATOM X.cite SOMATOM X.ceed In Radiation Therapy, patient positioning is paramount. The patient's position in the simulator CT room is the same as the patient's position in the treatment room. Patient position can also affect treatment beam directions. There are two ways to evaluate the patient for straightness: 1. Use the scan range borders. 2. View&GO tools. Use the Scan Range Borders 1. Register the patient for the examination. 2. Select the appropriate scan protocol. 3. Scan the Topogram and the image will populate in the pane. NOTE: If two sequential Topograms (e.g., AP and Lateral) are listed in the scan protocol; select the first Topogram in the chronicle to display it before scanning the subsequent Topogram. RTP Abdomen [factor ... topo, evaluation Siemens SOMATONn DO CT VA4DA Topogram *8/8/1974, 50Y 8/8/2024 12:45:43.77 PM 1 IMA 1 TOP 101 TP -750.0 HF supine HF prone HF right HF left Q. Q. C. c. FF supine FF prone FF right FF left Length 768 mm CTDIvol SPR (32 cm) 0.01 mGy DLP 0.66 mGy*cm mA 80 KV Sn 100 Exposure Time 4.60 5 Abdomen Reconstruction Patient Marking Close mA 80 A TI 4.6 513.0 0/0 Simulator Filter Sn Unrestricted | Published by Siemens Healthcare AG SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers 4. The user can then use the scan range lines to check for straightness. One example would be using the horizontal line through the eye canthus, or across the iliac wings. Another example would be using the vertical line down the spinal column. topo, evaluation Siemens *8/8/1974, 50Y 8/8/2024 12:45:43.77 PM 1 IMA1 TOP 101 -TP -- 750.0- A 513.0 0/0 Simulator Filter Sn 2.68 5. If a repeat Topogram is needed after patient adjustment, right-mouse-click on the Topogram in the timeline and select Repeat or continue with the scanning process if a repeat is not needed. 513.0 0/0 Simulator C 106 Filter om Show Parameters Delete Repeat Open Edit Mode L 4.6s 10.6s 2 O O 10 6. Remember to verify the desired location of the borders before acquiring the scan. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers Page 2 of 6 View&GO Tools 1. Register the patient for the examination. 2. Select the appropriate scan protocol. 3. Scan the Topogram, and the image will populate in the pane. 4. On the right-hand side, select the Topogram. RTP Abdomen [factor ... ¡ topo, evaluation Siemens SOMATOM go.Open Pro *8/8/1974, 50Y syngo CT VA\40A Topogram 8/8/2024 HFS 12:45:43.77 PM 1 IMA 1 TOP 101 TP -750.0 HF supine HF prone HF right HF loft FF supine FF prone FF right FF left Length 768 mm CTDIvol SPR (32 cm) 0.01 mGy DLP 0.66 mGy*cm mA 80 KV Sn 100 Exposure Time 4.60 5 Abdomen Reconstruction 10cm Patient Marking Close A 513.0 0/0 268 Simulator Filter Sn 106 5. Navigate to the Recon Ranges section and right-mouse click on the Topogram photo. 6. Select Send to CT View&GO. Recon Ranges Topogram Show Parameters Thorax Send to CT View&GO Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers Page 3 of 6 7. Select the View&GO tab. 8. Because the Topogram is not 3D, you can use a stack layout, typically, the stack 1X1, or double-click the image for full screen. CTVkw&GO CT View&GO Mack 2d Stock Ack Felsw Up topo, evaluation Siemens syngo CT VANDE 708/08/1974, 50Y 08/08/2024 Topogram 0.60 Tr20 cor [1] Favorite Tools 12:45:43.77 PM TOP 101 1 IM4 1 SP A135.0 Favorite Tools Printing kV Sn 100 mA 80 TI 4.6 GT 0.0 513 Filter Br 9. Navigate to the upper right-hand corner menu and select the Distance Line. Distance Line Measure straight distance [D] SOMAT(Pixel Lens -+- syn Arrow Marker Angle Text T Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers Page 4 of 6 10. Left-mouse click where you want to start, and move the mouse to where you want to end, and then release. 11. The lines can then be used to evaluate the image. 12. Turn off the tool by deselecting the Distance Line in the corner menu, or by pressing the ESC button on the keyboard. 21.42 cm H 13. If a repeat Topogram is needed after patient adjustment, right-mouse click on the Topogram in the timeline and select Repeat, or continue with the scanning process if a repeat is not needed. 14. Remember to verify the desired location of the borders before acquiring the scan. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemens Shanghai Healthcare Sector Henkestr. 127 40 Liberty Blvd. Medical Equipment Ltd. 91052 Erlangen Malvern, PA 19355-9998 USA 278 Zhou Shu Road Germany Telephone: +1-888-826-9702 Shanghai 201318 Phone: +49 9131 84-0 Customer Care Telephone: P.R. China https://www.siemens-healthineers.com +1-800-888-7436 Telephone: +1 847 304 7700 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 17 Sept 2024 | QR700012843 Healthineers Page 6 of 6
- topogram