SOMATOM go.Sim & SOMATOM go.Open Pro - Configuring Slice 0 within Mobile Workflow Job Aid USA
Step by step, this PDF introduces to you how to configure the slice 0 within the mobile workflow.
Target group: All users.
Audio: No.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
Configuring Slice 0 within Mobile Workflow | Job Aid SOMATOM go.Sim and SOMATOM go.Open Pro O This sequence enables the identification of the image slice at the Zero Table position as the reference slice at the Treatment Planning System. What has happened up to now? • You have selected either the Reference Slice at Zero Table position or Reference V Slice at calibration offset position setting in the Clinical configuration workspace. • On the Radiotherapy tab, turn on the Radiotherapy Mode. • You have prepared the RTP test. Creating the Slice 0 in the … CT Laser plane RT Laser plane … … 1. Tap the Zero RT Laser button to move the laser system to the + RT zero (0) position. see next page 2. Use the Feed In and Feed Out buttons to control the table so that the area of interest is within the laser origin of the RT laser beams. 3. Mark the laser origin with radio-opaque markers. 4. In the Tools area, tap the Table Position button to open the Table Position popover. -800.0 5. Tap Move to CT Laser. 6. Press and hold the MOVE key to move the table to the gantry laser plane. (The patient's skin markers align with the red crosshairs of the gantry laser light markers.) 7. Tap the Zero Table icon to set the patient table to zero (0). 0 8. Press and hold the Feed In or the Feed Out buttons to move the table to the topogram start position. 9. Acquire the topogram Acquire the tomogram. Reference Slice at Zero Position is the default setting to create Unrestricted Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 05 Mar 2020 | HOOD05162003074494 Job Aid Effective Date: 16 May 2024 I QR700007625 Healthineers Job Aid | Configuring Slice 0 within Mobile Workflow Effective Date: 22 July 2024 | QR700010384 the reference slice at the table zero position. (Setting in the Administration Portal must be at “ … set Zero … ”) Creating the Slice 0 in the … CT Laser plane RT Laser plane … … see previous page 1. Tap the Zero RT Laser button to move the laser system to the zero (0) position. RT 2. Use the Feed In and Feed Out buttons to control the stage so that the area of interest is within the laser origin of the RT laser beams. 3. Mark the laser origin with radio-opaque markers. 4. In the Tools area, tap the Zero Table icon. (The treatment planning system identifies the image slice at 0 the calibration offset position as the reference slice containing the location of the markers on the patient's skin. The setting in the Admin Portal needs to be “ … calibration offset position … ”) 5. Press and hold the Feed In or the Feed Out buttons to move the table to the topogram start position. 6. Acquire the topogram Acquire the tomogram. Please note: After the tomogram scan has been acquired, the Zero Table icon is deactivated. If you change the patient position for the next tomogram scan, the Zero Table icon is activated. Technical notes: The calibration offset between the center of the imaging device and the center of the laser device is configured in the Administration Portal. The calibration offset value that is configured in the Administration Portal and the calibration offset value in the Sim&GO configuration must be identical. SIEMENS Unrestricted Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Healthineers Master Template Effective Date: 05 Mar 2020 | HOOD05162003074494 Page 2 of 3 Job Aid | Configuring Slice 0 within Mobile Workflow Effective Date: 22 July 2024 | QR700010384 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or In- structions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Opera- tor Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functional- ity”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fic- tional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Healthineers Master Template Effective Date: 05 Mar 2020 | HOOD05162003074494 Page 3 of 3