Siemens Healthineers Academy

SOMATOM go. platform Routine Scan Workflow Video

This video provides an overview of a routine scan workflow, when operating a SOMATOM go. platform scanner.

Start the topogram scan. Fast planning defines the scan range automatically. If you want to adjust the scan range, select one of the white dots and drag it to the required position. Then select Go to start the tomogram scan. After the scan, select Reconstruction and select Recon All to start all Recon jobs. On the left side, you can find all recons. In the Job status window, you can see the progress of the Recon jobs which are running. In order to prioritize a specific Recon job, click on it and select Prioritize. Select close to close the current examination.

60 512 444 350 3. 4/1/2020 54 120 62 110 69 100 68 400 40 67 44 200 SOMATOM go. Routine Scan Workflow Video Scan 1 * 4/1/1976 (44) 444 Thorax (Adult) Recon Ranges Topogram Thorax Length mm CTDivol SPR (32 cm) 0.01 mGy DLP mA KV Sn 100 Scan Time Reconstruction Close Confirm GO Cancel 3.3s 4.8s Length 512 Scan Training Center Erlangen SOMATOM go Top syngo CT VA20A 1 IMA TOP 100 10cm KV Sn100 512 0/0 administ 10:19:38:77 AM 1 IMA 1 mAs Preconditions CTDIvol (32 cm) 4.86 mGy 122.1 mGy*cm Check image quality Activate Thorax scan 4.68 s SOMATOM go. Top 5.12 s SP2-901 2 LEN 318.9 mA 60 Loading scan parameters ... Start Thorax scan 10:20:28.31 AM RTD 200 KV 100 Eff. mAs 70 Quality ref. mAs 80 GT 0.0 413 0/0 5.1s MPR 200 SL 4.0 Coverage check result Scanned volume is sufficient. Repeat Scan Start Auto Tasking Start reconstructions Switch to Reconstruction Recon Next auto Tools MPR MIP Thin Set Ref Planning Base Switch to Close RT HRA RAF uto Sel Fov Job Status Range Name Series Description Requested Procedure Recon Progress Order Auto Recon Auto View&GO Transfer Nodes Auto Printing Local Application Workfl Thorax 5.00 Br40 S3 cor Thorax 5.00 Br40 S3 sag Thorax 10.00 Br60 S3 coronal On Off None Open Recon Tab Close patient Prioritize off Reconstructionse note that the learnim For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used'as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information Like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your Local Siemens Healthineers sales representative for the most current information. Please note that the learning material is for training purposes only! The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. and examples only. All names and data of patients, parameters and configuration dependent designations are fictional All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright Siemens Healthcare GmbH, 2020 SIEMENS Healthineers

  • somatom go.
  • somatom go
  • somatom
  • somotom
  • somatom go. up
  • somatom go.now
  • scan
  • workflow
  • routine