Siemens Healthineers Academy

SOMATOM go.All & SOMATOM go.Top VB10 Hardware Overview Online Training USA

This online training describes the hardware components and system features of the SOMATOM go.All and SOMATOM go.Top CT scanners, including the new gantry cover. 

Target group: Basic user, all users.
Audio: Yes.
Recommended to be viewed on the following devices: Tablet, laptop, desktop computer (sufficiently large display required).

Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue som_go_all_go_top_hw_vb10_new_customers Master Template HILS2218 | Effective Date: 25 Mar 2022 ? SOMATOM go.All & SOMATOM go.Top VB10 Hardware Overview Online Training Welcome to the SOMATOM go.All and SOMATOM go.Top VB10 Hardware Overview online training. This training will cover the five learning objectives on the right. 1 2 3 4 5 Recognize the operating state of the scanner Differentiate between the RSC and control box Gantry control panel and Remote Scan Control (RSC) Describe the function of the tablet Identify the components of the gantry front Welcome Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_01 Audio Script: Welcome to the SOMATOM go.All and SOMATOM go.Top VB10 Hardware Overview online training. This training will cover the five learning objectives on the right. Table with 2 columns and 4 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages show a ? button in the lower-right corner. Select the ? button to get a quick guide through the navigation elements. Select the button on the left upper corner to display or hide the menu. ? Navigation Hints Before you start, we would like to give you a few tips on how to navigate: Enjoy the course! ? Navigation Hints ? SOMATOM go.All & SOMATOM go.Top System Features System Features Computer Performance Computer Performance System Specification (1/2) System Specification (1/2) System Specification (2/2) System Specification (2/2) Introduction Introduction Introduction The SOMATOM go.All and SOMATOM go.Top scanners offer low-dose technology with the option of mobile operation and workflow automation. Features and components covered in this training are: Patient table Gantry Table foot switch Tablet Remote Scan Control (RSC) Control box The remainder of this online training will review only the features that are present in both scanners. Pending 510(k) Clearance SOMATOM go.All & SOMATOM go.Top Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_03 Audio Script: The SOMATOM go.All and SOMATOM go.Top scanners offer low-dose technology with the option of mobile operation and workflow automation. Features and components covered in this training are: Patient Table Gantry Table Foot Switch Tablet Remote Scan Control (RSC) control box The remainder of this online training will review only the features that are present in both scanners. Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. * Optional feature System Specification (2/2) Table with 3 columns and 7 rows SOMATOM go.All SOMATOM go.Top mA @ low kV 825 mA* @ 70 & 80 kV 825 mA* @ 70 & 80 kV Table load up to 227 kg (307 kg*) 227 kg (307kg*) Gantry aperture 70 cm 70 cm Generator power 75 kW, equivalent to 187 kW with SAFIRE 75 kW, equivalent to 187 kW with SAFIRE Slice acquisition 32 x 0.7 mm 64 x 0.6 mm Slices reconstructed 64 128 System Specification (1/2) * Optional feature Table with 3 columns and 8 rows SOMATOM go.All SOMATOM go.Top Scanner type Single Source Single Source Detectors Stellar Detector UFC (Ultra Fast Ceramics) Stellar Detector UFC (Ultra Fast Ceramics) Max. table speed 200 mm/s 200 mm/s In-plane temporal resolution 165 ms* 165 ms* Rotation time 0.5, 1.0, 0.33 s* 0.5, 1.0, 0.33 s* kV steps 70, 80, 90, 100, 110, 120, 130, 140 kV 70, 80, 90, 100, 110, 120, 130, 140 kV Tin Filter scanning Sn100, Sn110, Sn120, Sn130, Sn 140 kV Sn100, Sn110, Sn120, Sn130, Sn140 kV Computer Performance Table with 4 columns and 4 rows SOMATOM go.All SOMATOM go.Top FAST AWP + Ultra FAST IRS RAM: 32 GB DDR4 Hard disk size: 960 GB SDD Data storage: 432 GB Max. recon rate: 75 fps for FBP 55 fps for IR Raw data storage: 1.4 TB FAST AWP + Ultra FAST IRS RAM: 32 GB DDR4 Hard disk size: 960 GB SDD Data storage: 432 GB Max. recon rate: 75 fps for FBP 55 fps for IR Raw data storage: 1.4 TB Ultra FAST AWP + Ultra FAST IRS RAM: 64 GB DDR4 Hard disk size: 1,92 TB SDD Data storage: 1.236 TB Max. recon rate: 75 fps for FBP 55 fps for IR Raw data storage: 1.4 TB FAST AWP + Ultra FAST IRS II RAM: 32 GB DDR4 Hard disk size: 960 GB SDD Data storage: 432 GB Max. recon rate: 85 fps for FBP 65 fps for IR Raw data storage: 3.84 TB Ultra FAST AWP II + Ultra FAST IRS II RAM: 128 GB DDR4 Hard disk size: 3,84 TB SDD Data storage: 2,847 TB Max. recon rate: 85 fps for FBP 65 fps for IR Raw data storage: 3,84 TB System Features *Optional Table with 2 columns and 6 rows SOMATOM go.All SOMATOM go.Top 2.2 cm detector width and sub-millimeter slices over the whole detector width 3.8 cm detector width and sub-millimeter slices over the whole detector width Mechanical tilting: 30 degrees, bidirectional Mechanical tilting: 30 degrees, bidirectional High speed scanning with up to 100 mm/s High speed scanning with up to 175 mm/s Low dose, low kV imaging down to 70 kV with highest tube current of its class of up to 825 mA* Low dose, low kV imaging down to 70 kV with highest tube current of its class of up to 825 mA* Able to perform coronary and stroke assessment Dual energy scanning in routine with TwinBeam Dual Energy and zero-click post-processing ? Hardware Components We will describe the three main hardware components in detail: The patient table, the gantry, and the control box. Throughout the training, you will explore several important elements of the gantry. Hardware Components Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_04 Audio Script: We will describe the three main hardware components in detail: The patient table, the gantry, and the control box. Throughout the training, you will explore several important elements of the gantry. ? Patient Table This chapter gives you an overview of the characteristics and operating elements of the patient table. Select the tab arrows for more information. Table Components Retracting Lever Handle Physiological Measurement Module (PMM) Table Versions Patient Table Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_05 Audio Script: This chapter gives you an overview of the characteristics and operating elements of the patient table. Select the tab arrows for more information. Table Versions 227 kg / 500 lbs patient table Combined horizontal and vertical Max. load of 227 kg / 500 lbs 307 kg / 676 lbs patient table Combined horizontal and vertical movement Max. load of 307 kg / 676 lbs Physiological Measurement Module (PMM) The physiological measurement module is an optional device. It provides the receptacle for the electrocardiogram electrodes and a push button for changing the ECG channel. The PMM evaluates the ECG signal to detect the R-peaks. Select the marker on the left to learn more about PMM. PMM interface Push button Retracting Lever Handle In an emergency with the STOP key pressed or during a power failure, you can position the table top manually. You can use the handle at the end of the table to move the table top out of the gantry. Retracting lever handle Table Components The head end is the end of the patient table closer to the gantry. The foot end is the end of the patient table further away from the gantry. The patient table top is impervious to water. The table, mattress, and accessories are shaped such that they cause, if at all, only minimal artifacts. The markings on the positioning mat indicate the metal-free area of the patient table. The side rail can be long or short. The storage box and the side rail can slide along both sides of the table. Select the markers on the left to learn more about table components. Table foot end Storage box (optional) Side rail (optional) Table head end ? Gantry Front There are eight (8) major components of the gantry front. These include the tablet, Remote Scan Control, gantry control panel, gantry interface, laser light markers, the connector box, a gantry-mounted FAST 3D Camera and myExam Care, which consists of a full-range CARE 2D Camera, CARE Breathe, and the CARE Moodlight. Learn more about these components in this chapter. We will discuss the tablet and the Remote Scan Control in more detail later on in the training. FAST 3D Camera Produces a three-dimensional live image of the patient to help you with patient positioning and topogram planning Tablet Interaction device inside and outside the examination room with contact charging Tablet Interaction device inside and outside the examination room with contact charging Gantry Control Panel Shall be attached at the side which customer can operate most conveniently Wireless Remote Control Interaction device in the examination room with contact charging CARE 2D Camera Helps you observe the patient while moving the patient table during the examination CARE Breathe Gantry Ring Light It has the standard color orange and comes as standard on every scanner except for SOMATOM go.Now. Moodlight (optional) CARE Moodlight (optional) Gantry Front Audio Filename: SOMATOM_go.Now&go.Up_HW_Overview_06 Audio Script: There are eight (8) major components of the gantry front. These include the tablet, Remote Scan Control, gantry control panel, gantry interface, laser light markers, the connector box, a gantry-mounted FAST 3D Camera and myExam Care, which consists of a full-range CARE 2D Camera, CARE Breathe and the CARE Moodlight. Learn more about these components in this chapter. We will discuss the tablet and the Remote Scan Control in more detail later on in the training. ? FAST 3D Camera The FAST 3D Camera produces a three-dimensional live image of the patient to help you with patient positioning and topogram planning. Ceiling-mounted camera (optional) Ceiling-mounted camera (optional) X-ray indicator lights X-ray indicator lights FAST 3D Camera (gantry-mounted) FAST 3D Camera (gantry-mounted) FAST 3D Camera (gantry-mounted) FAST 3D Camera Provides you with live images that help you with patient positioning and collision detecting. Stop key This should only be used in case of emergencies. X-ray indicator Its location depends on your configuration. It is located either on the left or the right of the gantry-mounted FAST 3D Camera (optional) or in the center of the Halo cover plate on the gantry front. FAST 3D Camera Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_07 Audio Script: The gantry-mounted FAST 3D Camera provides you with live images that help you with patient positioning and collision detecting. X-ray indicator lights No illumination: No radiation Illumination in yellow: Radiation Ceiling-mounted camera (optional) The ceiling-mounted FAST 3D Camera captures data of the patient structure in three dimensions. It is equipped with an infrared light source and sensor, and an RGB camera. The ceiling-mounted FAST 3D Camera system is positioned above the patient table and in front of the gantry. The camera system allows automated patient positioning in the examination room. It consists of several components: Ceiling flange: Covers the fixation to the concrete or suspended ceiling Ceiling extension: The length of the ceiling extension is variable to allow an installation of the ceiling-mounted FAST 3D Camera at different room heights Ceiling-mounted FAST 3D Camera: Produces a three dimensional image of the patient structure 2 3 1 ? Laser Light Markers The light markers are laser beams that emanate from three points in the gantry opening. These points indicate the scan center and form a cross when the beams intersect. They help correctly position the patient. Please take caution that you or the patient do not look directly into the laser beam. Select the colored callouts on the right for more information. Laser Light Markers Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_08 Audio Script: The light markers are laser beams that emanate from three points in the gantry opening. These points indicate the scan center and form a cross when the beams intersect. They help correctly position the patient. Please take caution that you or the patient do not look directly into the laser beam. Select the colored callouts on the right for more information. To turn the light marker on, press the Light Marker key on the control box or the Remote Scan Control. After approximately one minute, the laser light marker is switched off automatically. If you want to switch off the light marker immediately, press the Light Marker key again. ? Ring Light Gantry Ring Light It has the color orange and comes as standard ambient light on every scanner except for SOMATOM go.Now. Moodlight (optional) Aims to reduce the patient's anxiety and stress levels during the examination by providing a soothing ambient light with different colors. CARE Moodlight (optional) Consists of LED lights on the gantry front cover and is used to indicate the following states: Scan countdown: LED lights are illuminated in white and turn off sequentially clockwise. Radiation on: LED lights are illuminated in yellow when the X-ray indicator is illuminated, and the scan is in progress. System startup: LED lights turn on sequentially counter-clockwise until all LED lights are illuminated in orange. Ring Light Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_09 Audio Script: The gantry ring light has the color orange and comes as standard ambient light on every scanner except for SOMATOM go.Now. The optional gantry ring Moodlight aims to reduce the patient's anxiety and stress levels during the examination by providing a soothing ambient light with different colors. The optional CARE Moodlight consists of LED lights on the gantry front cover and is used to indicate the following states: - Scan countdown - Radiation on - System startup Please read through the different CARE Moodlight states. ? CARE Breathe To help patients understand the different audio instructions during a scan, CARE Breathe displays visual patient instructions (VPI) before, during, and after a scan if the scan range has a patient instruction. You can find the CARE Breathe display units on the gantry front and back in the gantry funnel. Visual patient instruction: The green animation signals the patient to breathe normally. The yellow animation signals the patient to prepare to hold their breath. The ring represents a visual count down. The red animation signals the patient to not breathe or swallow as long as the red animation is displayed. The ring represents a visual count down. CARE Breathe CARE Breathe Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_10 Audio Script: To help patients understand the different audio instructions during a scan, CARE Breathe displays visual patient instructions (VPI) before, during and after a scan if the scan range has a patient instruction. You can find the CARE Breathe display units on the gantry front and back in the gantry funnel. Please read through the different Visual patient instructions. ? Gantry Interface The gantry provides several interfaces. You can find the connectors at the bottom right side of the gantry for various connections depending on the scanner's system configuration. i-Joystick interface X-ray foot switch interface Respiratory gating system interface Gantry Interface Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_11 Audio Script: The gantry provides several interfaces. You can find the connectors at the bottom right side of the gantry for various connections depending on the scanner's system configuration. ? Connector Box The connector box on the right side of the gantry is a key-locked box that houses service options. USB ports for USB 2.0 or higher USB ports for USB 2.0 or higher On/Off power button for the system SD (Secure Digital) card interface for service purposes only Connector Box Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_12 Audio Script: The Connector Box on the right side of the gantry, is a key locked box that houses service options. ? Table Foot Switch You can move the patient table by using the optional table foot switch. This is an alternative to using the keys on the Remote Scan Control or the control box. The table foot switch between the gantry and the patient table connects to the table through a cable. The table foot switch has two Load pedals and two Unload pedals. The pedals are located on both sides of the switch. Table Foot Switch Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_13 Audio Script: You can move the patient table by using the optional Table Foot Switch. This is an alternative to using the keys on the Remote Scan Control or the control box. The Table Foot Switch between the gantry and the patient table connects to the table through a cable. The Table Foot Switch has two Load pedals and two Unload pedals. The pedals are located on both sides of the switch. ? Gantry Back The back of the gantry includes the following components: X-ray indicator light Speaker and microphone to communicate with the patient Gantry intercom Full-range CARE 2D Camera Air filter 1 2 3 4 5 5 Gantry Back Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_14 Audio Script: The back of the gantry includes the following components: 1. an X-ray indicator light 2. a Speaker and microphone to communicate with the patient 3. a Gantry intercom 4. a Full-range CARE 2D Camera 5. an Air filter ? Tablet You can find one tablet or multiple tablets (optional) in the examination room. The CT Scan&GO application on these tablets allows you to perform workflows within the examination room. It synchronizes with the syngo Acquisition Workplace and wirelessly communicates data to the system. Select the tab arrows to learn more about the tablet. Tablet Storage Specifications Application Tablet Audio Filename: SOMATOM_go.Now&go.Up_HW_Overview_15 Audio Script: You can find one tablet or multiple tablets (optional) in the examination room. The CT Scan&GO application on these tablets allows you to perform workflows within the examination room. It synchronizes with the syngo Acquisition Workplace and wirelessly communicates data to the system. Select the tab arrows to learn more about the tablet. Application With the tablet, you can control the exam and scan workflow from inside and outside of the scan room. With Scan&GO technology, you just need a few steps for the entire scan. Start checking patient information as soon as you collect the patient from the waiting room. Then prepare the scan directly at the gantry to stay with the patient longer. Since the images are sent wirelessly from the scanner to the tablet, you can return to the patient after the scan. You can stay there while previewing the images and communicating with radiologists for instant feedback, if required. Specifications System: iPad OS 16 Display: 10,2" multi-touch display (Resolution: 2160 x 1620) Dimensions: 9.8 x 6.8 x 0.3 in (25 x 17.4 x 0.7 cm) Weight: 1.07 lbs (487 g) Please note: These specs may vary from one iPad version to another. Tablet Storage You can attach the tablet to the gantry and charge it in the cradle when you power on the scanner. You can also charge the gantry tablet by attaching it to the contacted charging docking station or the mechanic docking station. One gantry tablet is standard in the examination room. You can use up to four gantry tablets at the same time. If a facility has multiple systems and tablets, it should label the remote scan control and tablet of each respective system with matching identifiers. ? Gantry Control Panel The gantry control panel is standard configuration and part of your system. With the gantry control panel, you control The gantry functions The movement of the patient table Trigger scanning The gantry control panel has the same function keys as the wireless Remote Scan Control (RSC), except for the Out of Range indicator, the Power Off indicator, and the pairing label. Select the colored callouts on the left to learn more. Gantry Control Panel Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_16 Audio Script: The gantry control panel is standard configuration and part of your system. With the gantry control panel, you control The gantry functions, The movement of the patient table And trigger scanning. The gantry control panel has the same function keys as the wireless Remote Scan Control (RSC), except for the Out of Range indicator, the Power Off indicator, and the pairing label. Select the colored callouts on the left to learn more. Laser Light Marker key Press this key to turn the laser light markers on or off. Feed In key Press this key to move the patient table into the gantry. Suspend key Press this key to suspend the scan procedure. This is the preferred method for interrupting a scan before completion. Do not use the STOP key to suspend the scan procedure. Feed Down key Press this key to move the patient table down. This key is disabled if the table does not support a downward motion. Unload key Use this key to unload a patient. Feed Out key Press this key to move the patient table out of the gantry. Start key Press this key to trigger a scan. The X-ray indicator is illuminated when ready for a scan or during a scan. This key is disabled if there is no in-room monitor or tablet installed. Feed Up key Press this key to move the patient table up. This key is disabled if the table does not support an upward motion. Move key Press this key to move the table to the preselected scanning position. ? Wireless Remote Scan Control An optional interaction device in the examination room is the wireless Remote Scan Control (RSC). Select the colored callouts on the left to see which scanner functions you can control with the buttons on the RSC. Wireless Remote Scan Control Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_17 Audio Script: An optional interaction device in the examination room is the wireless Remote Scan Control (RSC). Select the colored callouts on the left to see which scanner functions you can control with the buttons on the RSC. Move key Press this key to move the table to the preselected scanning position. Laser Light Marker key Press this key to turn the laser light markers on or off. Feed In key Press this key to move the patient table into the gantry. Suspend key Press this key to suspend the scan procedure. This is the preferred method for interrupting a scan before completion. Do not use the STOP key to suspend the scan procedure. Feed Down key Press this key to move the patient table down. This key is disabled if the table does not support a downward motion. Unload key Use this key to unload a patient. Feed Out key Press this key to move the patient table out of the gantry. Start key Press this key to trigger a scan. The X-ray indicator is illuminated when ready for a scan or during a scan. This key is disabled if there is no in-room monitor or tablet installed. Feed Up key Press this key to move the patient table up. This key is disabled if the table does not support an upward motion. ? Charging The wireless RSC has rechargeable batteries. Charging On the cradle of the gantry At any USB port, for example, a monitor USB port Please note: The wireless RSC will not react to any operation while it is charging. Battery Indicator Status Not charging On (white): Battery full On (red): Battery medium Blinking (red): Battery low Off: Battery empty Charging Slow blinking (white): Charging On (white): Battery fully charged Fast blinking (white and red blinking alternatively): Charging fault Off: Hardware fault Charging Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_18 Audio Script: The wireless RSC has rechargeable batteries. You can charge the wireless RSC on the cradle of the gantry or at any USB port, for example, a monitor USB port. Please note: The wireless RSC will not react to any operation while it is charging. A battery indicator on the wireless Remote Scan Control shows you the current status of the battery as follows. ? Operating in Range The wireless RSC has a certain operating range limitation. Out of Range indicator: Off when you are within the operating range. Turns red when you are out of the operating range. Please note: Once the RSC is out of operation range, the connection turns off. As soon as the RSC is back in the operating range, it will establish the connection to the scanner automatically. This might take a few seconds. Operating in Range Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_19 Audio Script: The wireless RSC has a certain operating range limitation. This is shown by the Out of Range indicator located on the bottom left of the RSC. The Out of Range indicator is off when you are within the operating range. It turns to red when you are out of the operating range, and the connection turns off. As soon as the RSC is back in the operating range, it will establish the connection to the scanner automatically. This might take a few seconds. ? Dead Man's Switch To avoid unintended activation of keys, the wireless RSC includes a dead man's switch. User needs to activate it to enable any of the other keys on the device. Active when the user holds the wireless RSC. Activation of dead man's switch Grasp the lower half of the wireless RSC with your palm. Place your thumb on one side of the wireless RSC. Place your remaining fingers on the other side. Ensure your hands are in contact with both sides of the back of the wireless RSC. Dead Man's Switch Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_20 Audio Script: To avoid unintended activation of keys, the wireless Remote Scan Control includes a dead man's switch. The user needs to activate it to enable any of the other keys on the device. The dead man's switch is active when the user holds the wireless Remote Scan Control. In other situations, the switch is not active. To activate the dead man's switch, grasp the lower half of the RSC with your palm. Place your thumb on one side of the wireless Remote Scan Control and your remaining fingers on the other side. Ensure your hands are in contact with both sides of the back of the RSC. ? Control Box The control box enables you to start and stop a measurement and move the gantry and the table from outside of the examination room. You can find the operating elements for the intercom system also on the control box. Select the colored callouts on the left to see which scanner functions you can control with the keys on the control box. Control Box Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_21 Audio Script: The control box enables you to start and stop a measurement and move the gantry and the table from outside of the examination room. You can find the operating elements for the intercom system also on the control box. Select the colored callouts on the left to see which scanner functions you can control with the keys on the control box. STOP key Press this key to stop radiation and movements altogether in an emergency. Call Patient key Press and hold this key while speaking into the microphone. You can adjust the volume by pressing the + and - keys. The respective volume is indicated by light band. Listen to Patient key Press this key if you want to hear what the patient is saying. You can adjust the volume by pressing the + and - keys. The respective volume is indicated by light band. Move key Press this key to move the table to the preselected scanning position or tilt the gantry to the next measuring position. Feed In key Press this key to move the table into the gantry. Feed Out key Press this key to move the table out of the gantry. Feed Up key Press this key to move the patient table up. Feed Down key Press this key to move the patient table down. Suspend key Press this key to hold the scan procedure. This is the preferred method for interrupting a scan before completion. You should not use the STOP key for this purpose. Unload key Use this key to unload a patient. Laser Light Marker key Press this key to turn the laser light marker on or off. Start key Press this key to trigger a scan. The Start key on the control box is equipped with an X-ray indicator. A warning signal sounds when radiation is being generated. The color of the indicator shows the operating state of the system: When illuminated in green, the scanner is ready for scanning. When illuminated in yellow, radiation is being generated. Similarities ? Gantry control panel Wireless Remote Scan Control (RSC) Control box Similarities Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_22 Audio Script: You may have noticed that the wireless Remote Scan Control and the control box have several hardware buttons in common. Please take some time and compare the similarities among gantry control panel, wireless Remote Scan Control and control box. The manual keys that appear on the devices are color coded to better show similarities. ? Additional Components The SOMATOM go.All and SOMATOM go.Top scanners have additional components including the injector arm, the X-ray foot switch, a tablet dock, and the i-Joystick. Select the numbered steps below or the pictures on the right to learn more about additional components. 1 1 1 2 2 2 3 3 3 4 4 4 Additional Components Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_23 Audio Script: The SOMATOM go.All and SOMATOM go.Top scanners have additional components including the injector arm, the X-ray foot switch, a tablet dock, and the i-joystick. Select the numbered steps below to learn more about additional components. 4 i-Joystick You can use the i-Joystick to move the table during myNeedle Guide procedures in the examination room. You can mount the i-Joystick to the rail on either side of the table to control the horizontal table movements. It can be removed for non-interventional examinations. The i-Joystick provides two interchangeable interfaces: Connect the i-Joystick to the gantry or, if you are using a multi-purpose table, to the table. Connect the tablet dock to the i-Joystick to charge the tablet. 3 Tablet Dock You can mount the tablet dock to the rail on either side of the table. You can press and hold the button at the front of the tablet dock to adjust the height or the tilt angle, or to rotate the tablet dock. For long intervention procedures, it may be necessary to ensure continuous power. In this case, make sure that the tablet dock is plugged in to charge the tablet. 2 X-ray Foot Switch With the optional X-ray foot switch, you can trigger scanning as an alternative to using the Start key. In CT-guided intervention examinations, a scan can be controlled with the X-ray foot switch in the examination room. The X-ray foot switch is disabled by default. It is enabled if an in-room monitor or a tablet-PC is installed, and a connection to the in-room scan app is established. 1 Injector Arm The injector arm enables you to place the injector in a position that is convenient for you, such as the front or rear side of the gantry. The injector arm is available as an option. It is used to mount a dedicated MEDRAD injector in the examination room. You can rotate the injector vertically or horizontally within a certain range by using the injector arm. ? Course Review Congratulations. You have completed the SOMATOM go.All & SOMATOM go.Top VB10 Hardware Overview Online Training. Listed below are the key points of this training. Take time to review the material before you proceed to the final quiz. Recognize the operating state of the scanner Gantry control panel and Remote Scan Control (RSC) Describe the function of the tablet Identify the components of the gantry front 1 1 2 2 2 3 3 3 4 4 4 Differentiate between the RSC and control box 5 5 Course Review Audio Filename: SOMATOM_go.All&go.Top_HW_Overview_24 Audio Script: Congratulations. You have completed the SOMATOM go.All & SOMATOM go.Top VB10 Hardware Overview Online Training course. Listed below are the key points of this training. Take time to review the material before you proceed to the final quiz. Differentiate Between the RSC and Control Box A possible interaction device in the examination room is the wireless Remote Scan Control (RSC). With the operating elements of the control box, you can start and stop a scan and move the gantry and the table from outside of the examination room. ? Recognize the Operating State of the Scanner The color of the indicator shows the operating state of the system: When illuminated in green, the scanner is ready for scanning. When illuminated in yellow, radiation is being generated. ? Gantry Control Panel and Remote Scan Control (RSC) The gantry control panel is standard configuration and part of your system. With the gantry control panel, you control The gantry functions The movement of the patient table And trigger scanning The gantry control panel has the same function keys as the wireless Remote Scan Control (RSC), except for the Out of Range indicator, the Power Off indicator, and the pairing label. ? Describe the Function of the Tablet Specifications System: iPad OS 16 Display: 10.2" multi-touch display (Resolution: 2160 x 1620) Dimensions: 9.8 x 6.8 x 0.3 in (25 x 17.4 x 0.7 cm) Weight: 1.07 lbs (487 g) Please note: These specs may change from one iPad version to the other. Storage and Charging You can attach up to two tablets at the gantry front and optionally up to two tablets at the gantry back The tablet is charged when it is attached to the gantry and the system is powered on The tablet is also charged when it is attached to the contacted charging docking station Scan&GO Perform basic workflows within the examination room. Prepare the scan directly at the gantry. Review images on the tablet. Pairing Identical pairing labels on the tablet and the gantry enable you to identify if they are paired to function together ? Identify Components of the Gantry Front FAST 3D Camera Produces a three-dimensional live image of the patient to help you with patient positioning and topogram planning Tablet Interaction device inside and outside the examination room with contact charging Tablet Interaction device inside and outside the examination room with contact charging Gantry Control Panel Shall be attached at the side which customer can operate most conveniently Wireless Remote Control Interaction device in the examination room with contact charging CARE 2D Camera Helps you observe the patient while moving the patient table during the examination CARE Breathe Gantry Ring Light It has the standard color orange and comes as standard on every scanner except for SOMATOM go.Now. Moodlight (optional) CARE Moodlight (optional) ? Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2023 Siemens Healthineers Headquarters\Siemens Healthineers AG\Siemensstr. 3\ 91301 Forchheim\Germany\Phone: +49 9191 18-0\siemens-healthineers.com ? Disclaimer Assessment Welcome to the assessment. For each question, select the button to the left of your answer, and then select Submit. You will have 3 attempts to take this assessment and to successfully pass this course, you must receive a score of 80% or higher. You will receive your score when you have completed the assessment. Note: If you close the learning activity at any time before you have finished the quiz, your answers will not be saved. Select Start to begin. Start Assessment Select the best answer. ? The Suspend key and Out of Range indicator The Out of Range and Low Battery indicators Question 1 of 5 Which of the following are present on the RSC and the control box? The Feed In and Light Marker key The Volume keys and Light Marker key Multiple Choice Select the best answer. ? Green White Question 2 of 5 What is the correct color of illumination to indicate radiation on the control box? Red Yellow Multiple Choice Select the best answer. ? Laser light markers, connector box, patient table Halo, Remote Scan Control, control box Question 3 of 5 What are the components of the gantry front? Laser light markers, Remote Scan Control, tablet Control box, table foot switch, tablet Multiple Choice Select the best answer. ? …runs on non-rechargeable batteries, so you can use it inside the scan room to stay with the patient longer. The tablet uses Scan&GO technology. Question 4 of 5 What are the three key features of the tablet? The tablet… …communicates wirelessly with the control box, allows you to start collecting patient information in the waiting room, and allows you to stay with the patient longer. …works inside and outside of the scan room, uses Scan&GO technology, and allows you to stay with the patient longer. Multiple Choice Select the best answer. ? Both the wired and the wireless RSC have a dead man’s switch. The wireless RSC has an Out of Range and a Low Battery indicator. Question 5 of 5 Which of the following statements is correct? Both the wired and wireless RSC microphones are located at the bottom of the remote. The wired RSC has Volume keys, a suspend key, and a dead man's switch. Multiple Choice Retry Assessment Results %Quiz1.ScorePercent%% %Quiz1.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Results Slide You have exceeded your number of assessment attempts. Exit You did not pass the course. Select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the SOMATOM go.All & SOMATOM go.Top Hardware Overview Online Training. Completion Question Bank 1 SOMATOM go.all_go_top_vb10-USA scorm 1.1 Welcome 1.2 Navigation Hints 1.3 SOMATOM go.All & SOMATOM go.Top 1.4 Hardware Components 1.5 Patient Table 1.6 Gantry Front 1.7 FAST 3D Camera 1.8 Laser Light Markers 1.9 Ring Light 1.10 CARE Breathe 1.11 Gantry Interface 1.12 Connector Box 1.13 Table Foot Switch 1.14 Gantry Back 1.15 Tablet 1.16 Gantry Control Panel 1.17 Wireless Remote Scan Control 1.18 Charging 1.19 Operating in Range 1.20 Dead Man's Switch 1.21 Control Box 1.22 Similarities 1.23 Additional Components 1.24 Course Review 1.25 Disclaimer 1.26 Assessment 1.33 Completion

  • somatom
  • somotom
  • go
  • all
  • top
  • hardware
  • component
  • feature
  • gantry
  • cover
  • vb10