Siemens Healthineers Academy

SmartSimulator Workbook – Basics: Scan UI

This workbook will guide you through your lab sessions with MAGNETOM Skyra VA30 in the SmartSimulator. The material in this Basics: Scan UI workbook is based on the Numaris X platform’s general features and includes a description of the scan user interface.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)

SmartSimulator Workbook Basics: Scan UI MAGNETOM Skyra VA30 https://smartsimulator.siemens-healthineers.com/#/ SIEMENS SIEMENS Healthineers Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 15 Dec 2022 | HOOD05162003319097 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Table of Contents Foreword 3 MR System Overview 5 Examination user interface 5 User interface 8 1.1 Scheduler – Entry point to the examination workflow at the acquisition workplace 8 1.2 Scheduler - Search Field 12 Patient Registration 16 2.1 Patient Registration tab 16 2.2 Program Selection tab 18 2.3 Examination Information 22 2.4 Toolbar 23 User interface - Examination UI screen 25 3.1 Examination UI - Queue 38 3.2 Exam UI queue – Toolbars 44 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 2 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Foreword Dear Participant, Welcome to the SmartSimulator Workbook! This workbook will guide you through your lab sessions with MAGNETOM Skyra VA30 in the SmartSimulator. You will have a maximum of 8 hours with your MAGNETOM Skyra VA30 SmartSimulator – so make the most of it, have some fun and explore what it can do. The material in this Basics: Scan UI workbook is based on the Numaris X platform’s general features and includes a description of the scan user interface. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means be regarded as a substitute for the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of these Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the latest information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 3 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 © Siemens Healthcare GmbH 2023 Good luck and we hope you enjoy your SmartSimulator time. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 4 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 MR System Overview Examination user interface Before you undertake the following exercises, please learn more on PEPconnect: Outside US: System start-up and Home screen (siemens-info.com) US: System Start-Up and Home- Screen (XA30) Home screen Home screen icons are visible as soon as the MR system is up and running. colthingers> CH System Check Dot Cockpit Examination Lock Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 5 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 a) System Check icon – Status of the MR system to open the Customer Service Portal: O X MR System Ready MR System Warning MR Maintenance Required Operational – No Errors Possible Errors Errors Occurred Please make sure that MR System Ready is available before carrying out any examinations. The System Check icon provides quick access to the System Status Overview tab of the Administration Portal. b) Status overview of the entire MR system: • Startup Reports • Customer Environment • Periphery Groups • Host Infrastructure • Licenses • Quality Assurance c) Dot Cockpit icon: Ability to create and manage examination programs d) Examination icon: Open the examination user interface to access Scheduler and Patient Registration Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 6 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 e) Lock icon: Lock/Unlock the workplace 1. Within the Home screen in the lower right corner you can find the Restart button to carry out the following operations: a) Restart MR system b) Shut down MR system c) Restart workplace d) Standby system Restart System Shut Down System Restart Workplace Standby System Exercise 1. Home screen is visible 2. Click on the Examination icon 3. Return to the Home screen The Home icon can be found in the Search field and Results list area. SIEMENS Healthineers .. O Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 7 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 User interface 1.1 Scheduler – Entry point to the examination workflow at the acquisition workplace Learn more on PEPconnect: Outside US: Scheduler (siemens-info.com) US: Scheduler (XA30) You will learn and practice the following Functions: • Visualizing/retrieving planned procedures and corresponding patient data • Adding, deleting and/or correcting planned procedures and corresponding patient data before the examination starts • Searching for and retrieving prior studies • Procedure status visualization • Starting the examination • Managing the procedure status (MPPS) Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 8 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Click on the Examination icon on the Homescreen O CH System Check Dot Cockpit Examination Lock In the Scheduler and you will find the following areas: tewithingers › O Scheduler 2 1 3 Patients Sulle Medical Information Examination Information Mama Mia "titreses, female Aamperios Nr. Fil, An Alerts Chaly Denopten "tit/1965, female SASOR0032 81 4/2006, 10:34 Medical Al PAudy Comment Fil, An "in1965, Female SA5000032 5 4 Jack, Daniels Institution Melbourne, Bob vit Scan Wust Gaga, Lady SASOOOOCE 1 Scan Heat 8142006, 14:15 Clooney, George Physician Program Selection 814000€. 14.30 Operator Gaga, Lady Lead Program te Queue "530/1 985, Female SASOOOOCE Mit SuasCHdix Angay- art4/2toc. 15:15 RF Transmit Mode Melbourne, Bob Patient Orientation Safiy revant intrmarion rodi to be calcioed and sortirrad "Mandatory rformation Caval Local Outa Per Stadles tan 1. Search and Filter area 2. Patient Registration and Program Selection tabs 3. Toolbar 4. Content area of patient Registration or Program Selection tabs 5. Patients list Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 9 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Go to the Patients list area and select Procedures to change the Display list SIEMENS Healthineers Scheduler Search by Name, ID, DoB, Description, Procedure Date, Acc No. and Modality (Ctrl+F) Q Patients Scheduled, Today (0 result(s), 2:03:55 PM) C Patient Procedure Date and Time Display list of Procedures. Overview of the Scheduler concepts: • Patients list is the worklist for your daily work and represents one or more planned procedures for a registered patient • In the Scheduler, change patient and procedure data before you start the examination • If connected to an RIS – Acquisition workplace retrieves data from the RIS at regular intervals • Patients list view switch gives the Option to switch between Patients view and Procedures view in the Patients list Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 10 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Patients Procedures Exercise 1. Select the Patients list and switch between: a) Patients view b) Procedures view Patients list options: • Procedures (default) • List of procedures • List of patients with assigned procedures • Patient • Shows one or more procedures for a registered patient • Shows available procedure data & patient data Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 11 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Sort the Patients list by: a) Sort by b) Filter by Time c) Filter by Status Sort by Patients seleclicked Tochy (15 results) 9:21.18 PM Patiort Mama Sort by enc Name ascending nt flame descending stent ID ascending Fil, An Faktent. ID descending Drie of Birth excendigi Filter by Time Date of Birth descending Filter by Status Patients Scheduled, Nohay (15 cas to), 11 21:4 PV) Dife int Tinet Patent Dote and Tive Filter by time Mama Mia Filter by status Fil, An Tenorday *1/1/1955, Femal SA5000026 Scheduled Fil, An Scanrad Fil. An Aatime MR Scan Prostate 8:04/2020, 10:34 1.2 Scheduler - Search Field General information: 1. Search by: a) Patient name b) Date of birth c) Patient ID d) Accession number e) Procedure description f) Procedure start date Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 12 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 g) Modality Scheduler Search by Name, ID, DoB, Description, Procedure Date, Acc No. and Modality (Ctrl+F) Q Patients Scheduled, Today (15 result(s), 9:21:18 PM) G Patient Procedure Date and Time Mama Mia +1/1/1965, Female SAS000026 MR Scan Brain Angiogram 8/14/2020, 10:26 Fil, An *1/1/1965, Female SAS000032 MR Scan Prostate 8/14/2020, 10:34 Fil, An *1/1/1965, Female SAS000032 MR Scan Pelvis 8/14/2020, 10:34 Please note: • Wildcards are supported[*] before or after the search word • Date and time formats • DICOM format (YYYYMMDD) • Windows regional settings Continue an examination SIEMENS Healthineers Patient Browser Local Data Search try Name, ID, Date, Description ani Modality (Cul+F) More Filters Results (69 results, 9:10:20 AM) Patient Name Patient ID Date of Birth Study Date a ... Study Descripti ... Accession Nu ... Work View&GO Dat ... 123456789 1/28/1991 1128/2021 9 View&GO Dat. Aera Abdomen Germany_MAC 8/14/2020 Aera Abdomen Germany_MAC 6/1/1966 8/13/2020 Open Ctrl+O Aera Neck Austria_MAC 8/1 1/2020 Open with Meta_Knee Germany_MAC 8/1 1/2020 8/1 1/2020 View as Read-Only with hera_Heart Germany_MAC 8/5/2020 B/4/2020 95 Batch Open Aera_Knee Germany_MAC 7/31/2020 7/31/2020 Prisma_Head Germany_MAC 7/24/1967 7/24/2020 Assign Workflow Prisma_C-spine Germany_MAC 2/5/1947 7/22/2020 Cancel Workflow Prisma_Head Germany_MAC 3/2/1952 7/22/2020 Search Patient with DICOM OUR Aera Anide Germany_MAC 2/1/1940 7/16/2020 Add to Demo List Aera L-spine Austria_MAC 7/7/2020 717/2020 6: Prisma_Pelvis ... Germany_MAC 7/13/2001 7/1/2020 1: Remove from Demo List Skyra_Angio Germany_MAC 1/1/1970 6/24/2020 Set Mark state Skyra_Hand Germany_MAC 2/2/1991 6/22/2020 5 Set Delete Protection state Skyra_Breast Germany_MAC 1/1/1976 6/22/2020 Set Archive state Prisma Elbow Siemens_MAC 1/1/1989 1/23/2020 4 Aera_Head Siemens MAC 1/1/1947 1/21/2020 Remove Correction state Skyra_Heart Siemens MAC 2/1/1956 1/14/2020 New Examination Aera Heart Siemens MAC 1/1/1953 1/14/2020 Resume Examination Skyra_Heart Siemens MAC 1/1/1956 1/10/2020 Skyra Head Siemens MAC 1/1/1969 1/9/2020 11 Prisma Head Siemens MAC 1/1/1945 12/5/2019 Cut Altea Abdomen Siemens MAC 5/3/1995 10/18/2019 Paste Al RC Prostate ... Belgium MAC 1/1/1949 6/6/2019 11 Delete Del ans MA XA11 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 13 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Please perform the following steps within the Scheduler: a) Select Filter by Status > Scanned items b) Select the Patient and complete the Registration again 2. Select Patient Browser icon – defaults to Local Data base a) Select an existing patient from the list b) Right click and select New Examination – generates a new study c) Complete and confirm the registration. d) Select Patient Browser icon e) Select the same patient > right click and select Resume Examination f) Complete and confirm the registration – the study already examined is resumed within the same study Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 14 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Before we proceed with Patient Registration, some important information about correcting Patient Data must be kept in mind: Correcting Patient Data Please note: Modify local patient data before starting the examination: • It is possible to change any patient data • Correcting the Height & Weight attributes only affects the selected procedure. If more than one procedure - for the same patient exists, you have to change these attributes separately for every procedure. • Correcting attributes that are used for patient identification by the Scheduler only affects the selected procedure Example: Patient ID • Constraints on patient data received from the RIS: • Only empty fields can be adapted • Height and Weight attributes can be updated, Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 15 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 even if the field has been filled out in the RIS Please note: Patient data is only saved locally when it is updated on the MR scanner. If the patient data is used across modalities, change the patient data in the central information system (RIS), then refresh the data on the scanner. Patient Registration Please learn more on PEPconnect: Outside US: Patient Registration (siemens- info.com) US: Patient Registration (XA30) 2.1 Patient Registration tab Click the Register Patient icon. The Patient Registration tab of the Scheduler is shown. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 16 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 a) View and enter the examination data for the patient b) All fields marked with an * are mandatory – Please complete the entries c) Select the orange Exam button – button is active once all mandatory fields are completed Please note: If the Exam button is selected at any time during registration, any mandatory fields that are missing will be highlighted: SIEMENS Healthineers O Scheduler Medical Information Examination Information Alerts Institution Program Selection RF Transmit Mode Patient Orientation Sent Background: Plausibility check – Orange fields have safety relevant information which needs to be validated and confirmed. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 17 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Corrections in the dialog box are possible! . Date of Birth | 10/8/1980 M/d/yyyy Allergie Plausibility Check The entered patient values are not plausible. Please confirm or correct the values. Name Inician Date of Birth | 10/8/1980 M/d/yy Age 39 Year(s) Height 6 0 4 in mician Weigh 20 erator This is an unusually low weight. Confirm Cancel ISafety relevant information needs to be validated and confirmed "Mandatory information Save Cancel Delete Local Data Prior Studies 2.2 Program Selection tab Please learn more on PEPconnect: Outside US: Program Selection (siemens- info.com) US: Program Selection (XA30) a) Patient Data: Data entered on Patient Registration tab b) All Programs: Area to access all examination programs stored on the system (e.g., Siemens, User Programs) c) Examination Information: Specific settings from the Patient Registration tab Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 18 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise Program Selection Patient Registration Program Selection test All Programs Examination Information Last Name test SIEMENS Procedure First Name Accession Nr. Middle Name Q Req Proc ID * Patient ID Study Description . head . Date of Birth |10/8/1980 [M/d/yyyy] > c-spine Study Comment * Age |39 Year(s) › t-spine Sex M (Male) › I-spine . whole-spine Height |6 ft in neck soft tissue Weight 200 lbs › thorax · heart Medical Information › breast › abdomen Admitting Diagnosis pelvis female > pelvis male Alerts · shoulder Medical Alerts elbow Allergies WTIST › hand Program Selection hip Select knee Load Program to Queue › ankle · foot RF Transmit Mode · whole body oncology Any Polarization peripheral angiography › spectroscopy Patient Orientation intervention Select ISafety relevant information needs to be validated and confirmed " Mandatory information Save Cancel Delete Local Data Prior Studies Exam The top 10 programs are displayed for selection 1. Open the selection list and choose one of the appropriate programs (if any are available) 2. To Delete items > right-click and select “Remove item from list” (i.e., If any programs are available within the pre- selected list) 3. Select Other Examination… to navigate to the Program Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 19 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 4. Program Selection tab and choose an exam from the All Program list All Programs Examination Information SIEMENS Procedure Accession Nr. Req. Proc. ID Study Description head c-spine Study Comment > t-spine > I-spine > whole-spine > neck soft tissue ›thorax heart breast abdomen pelvis female wrist Program Selection > pelvis male > tmj Select › shoulder Load Program to Queue elbow RF Transmit Mode hand > hip Any Polarization knee Patient Orientation > ankle foot IT Select Exercise Patient Orientation Standard positions: • Head First Supine • Feet First Supine • Head First Prone • Feet First Prone • Head First Left Lateral • Feet First Right Lateral • Head First Right Lateral • Feet First Left Lateral 1. Select Head First Supine for Head examination Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 20 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Head First Feet First Supine Supine Head First Feet First Prone Prone Head First Feet First Left Right Lateral Lateral Head First Feet First Right Left Lateral Lateral Special Orientations ... Special orientations: • Superman Wrist Supine • Superman Wrist Prone • Superman Elbow Supine • Superman Elbow Prone 2. Select Superman Wrist Prone for Hand/Wrist examination O Superman Superman Wrist Supine Wrist Prone Superman Elbow Superman Supine Elbow Prone Standard Orientations ... Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 21 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 2.3 Examination Information • Multi‐study registration • Procedures are consecutively numbered • Displayed with individual procedure information • Program & Study Parts are mapped Ready to Examine Sach Air Name il Dor. Cescription Procedling late Accio and AModaliy formaE) Q Patients Scheduled, Today (10 result(s), 1:01:49 AM) Patient Procedure Date and Time Clooney, George *1/1/1960, Male SAS000025 MR Scan Knee 8/14/2020, 14:30 Fil, An *1/1/1965, Female SAS(XXX0032 MR Scan Prostate 8/14/2020, 10:34 Fil, An *1/1/1965, Female SAS000032 MR Scan Pelvis 8/14/2020, 10:34 Gaga, Lady *S/30/1985, Female MR Scan Heart SAS000008 more ... 8/14/020, 10:00 Jack, Daniels Emergency Register Patient Patient Patient Procedure Examination Information MR Scan Heart Accession Nr. 0495A1P000000090 Req. Proc. ID 71 * Study Part Study Description Study Comment MR Scan Heart Accession Nr. 0495A1P000000105 Req. Proc. ID 85 Study Part Program Selection Multi-study Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 22 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 • All Study Parts must be assigned • Define Study Parts within your Multi StudyProgram in Dot Cockpit • Defaults generated if program has none • Study Part assignments saved for later use! Examination Information MR Scan Heart Accession Nr. 0495A1P000000090 Req. Proc. ID: 71 * Study Part Study Description Study Comment MR Scan Heart Accession Nr. 0495A1 P000000106 Req. Proc. ID 85 Study Part 2.4 Toolbar Right side above Patient Registration and Program Selection content area Emergency Add Patient Delete Patient Examin ... Query Procedure Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 23 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Please click on Emergency Patient a) Complete all mandatory fields. Minimal input is required fast registration can be done – b) Select Scheduler 2. Select previous patient registered (e.g., emergency) a) Right-click and select Add Examination 3. Click on Delete Procedure icon a) Select a locally registered patient from the Patients list b) You can delete a locally registered patient from the Patients list as long as the exam has not started Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 24 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 User interface - Examination UI screen Examination screen: Manages all individual tasks throughout the examination. General overview including the following features: • Patient Tab • Protocol Info Line • Queue • GSP Segments • Stamp Segments • Flyout Toolbar • Exam Toolbar • Parameter Card • Status Bar SIEMENS Healthineers ME VwAGO Broin Dot Engine PLOC / ** * + Gren Del CHans 09:31 Queue & Add-In Area GSP Segments 347FF (Am (42 1107-47-401 1:00 Stamp Segments Exam Toolbar Parameter Card Area Status Bar wating for skx postisurg Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 25 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Please register a patient 2. Select exam program: Brain Dot Engine 3. Click on Exam: a) Simulated Brain Dot Engine workflow is loaded, click on GO to start the localizer b) During the acquisition, please go to the Exam toolbar and open the Inline Display c) Enlarge GSP Overview segment as soon the localizer image is loaded to it d) Open the flyout toolbar and switch from Line Mode to Package Mode Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 26 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 3-1 .. 00:03 MR Viewtico Flyout Toolbar GSP Overview Segment @ 4:38 min ( Aute @ 2 @ 07-0.7-4.0mm + 1.00 Parameters Inline Display aligned by AutoAlign. Note that if you change slice positions manually, it SU Bow up csamirations. ap 1 - FaitView Cariculation of AunAlign wwit is ongoing. Please wait. Exercise Stamp segments 1. While the examination is running: a) Hover the move over the stamp segment – each stamp segment represents one series b) Enlarged thumbnail c) Check the series information displayed Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 27 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Step 14-12_qtse_tra_p3 MAON NORMO _qtse_tra_p3 22_gtse_tra_p3 19 HO Exercise GSP segments 1. GSP segments: The acquired protocols are done and loaded into the GSP (graphical slice positioning) a) Perform a multi-selection of GSP segments > Ctrl + left click • Window the multi-selected segments • Scroll through the multi- selected segments • Zoom/Pan the multi- selected segments b) Enlarge GSP segment > Double-click left mouse button c) Load a series into the Stamp Segments using drag and drop Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 28 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 d) In the measurement queue, depress left-mouse on a Series icon and drag the series into one of the GSP segments t1_mprage_sag_p2_iso Exercise GSP corner menus Corner menus provide specific interactive tools and other user interface elements to support individual tasks throughout the examination. Corner menus are available in all corners of the GSP segments. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 29 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 The lower left corner menu is empty and not used in the GSP. HPL Abdomen 2020.09.25-21:03:00-DST-1.3.12.2.1107-5.99.3- 1 IMA1 FRM 1/1 RPH 5cm A TP 0 SP P19.6 FoV 259*259 .JMPR/RESAMP/NORM/DIS3D Cor>Tra(3)>Sag(-3) AAhead_scout_MPR_cor W Not for diagnostic use 276 1. Select upper left corner menu a) Zoom/Pan – magnify or move image within planning segment b) Windowing – adjust image brightness and contrast c) Scroll – page through images in planning segment Please note: Use Middle mouse to Window/Center images; Depress right mouse and rag Up/Down to scroll through images. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 30 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 d) Fit to Segment – resizes images and remove zoon/pan in the selected segment e) Movie – Movie panel opens to scroll images interactively (e.g. Cardiac movie/real‐time movie support) Zoom/Pan HPL Windowing 31.) 3.12.2.1107-5.99.3- Rotate Scroll Du Movie Fit to Segment R : A Flip Horizontal RPH 5cm 60 FIS no skip 2. Select upper right corner menu a) Pixel Coordinates: Please activate pixel lens HP Pixel Coordinates Abdomen 2020.09.25-21:03:00-DST.J.3.12.2.1107-5.99.3- - - 1 IMA 1 FRM 1/1 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 31 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 3. Lower right corner menu a) Window the images, then left click lower right corner menu and select “Auto Windowing”. The window width & center for the images/series in the selected segment(s) are reset to the original window values automatically b) Change sorting of images displayed in planning segment by choosing the Display Order function: • Anatomical (image position and orientation) • As Numbered (image number) • Chronological (acquisition time) • Triggered (trigger time) SFF19.U FoV 259*259 JMPR/RESAMP/NORM/DIS3D Cor>Tra(3)>Sag(-3) AAhead_scout_MPR_cor Auto Windowing Anatomical Display Order Te As Numbered # Chronological .... + Triggered Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 32 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise GSP context menu: Clear All Segments & Perpendicular 1. Open the GSP context menu > Right click on planning segment a) Clear All Segments – Only clears planning segments (stamp segments remain the same) b) Perpendicular – Aligns object perpendicular to reference plane •Select object to be aligned • Right click > Select Perpendicular from the context menu of the planning segment MAL Brain 2023.01.11-12:03:09 STD-1.3-12 2.1107.5 99.3 10 IMA 1 FRM 96/192 Cleat All Segments Shift to Image Plane C5 Group Graphica IN Perpendicular ARF Non Duale Copy Image Position BD Repeat Step 5cm 2 Hepest & Open Step TP O SP R1.2 FoV 240 240 P2 MAGNINORWDISZO 13>Cor[3]>Tre(1) Hi_mprage_sag_p2_iso W 749 C 330 Not for diagn Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 33 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise GSP context menu: Copy Image Position Copy Image Position – Copies position and orientation of current displayed image in GSP segment into open target sequence in measurement queue 1. Open the Target sequence in the measurement queue a) Select the Reference image in the GSP segment b) Right click > select Copy Image Position from the content menu -or- Right-click on a Stamp Segment > select Copy Image Position Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 34 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 HPL Abdomen 2020.09. 2.1107-5.99.3 -- Dod Clear All Segments" 1 IMA 1 FR shift to Image Plane Group Graphics Perpendicular ‹ orthogonal Align Parallel RPH Align Fov Copy Image Position cm Find Localizer Repeat Step A Repeat & Open Step TP 0 SP P19.6 FoV 259-259 JMPRIRESAMP/NORMIDIS Copy ParametersCor- Tra(3)=Sag(-3) AAhead_scout_MPR_cor 563 Create Snapshot C 276 Not AFR 12.2.1107.5.99.3 Copy Image Position Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 35 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise GSP context menu: Find Localizer Search all images loaded in GSP planning segments for reference images suitable for current table position of an open sequence 1. Open sequence pending in measurement queue a) Right click > Select Find Localizer from the context menu of the planning segment b) Images of a series with the smallest deviation from the protocol table position in Z‐ direction are displayed (e.g., deviation cannot exceed a system‐internal tolerance value) HAL Brain 2023.01 11-12:03:09-STD-1.3.12.2.1107.5 99.3 5 IMA 1 FRM 15/29 Clear All Segments shift to Image Plane ARE CŒ Giroup Graphics la Perpendicular Nig Parallel Copy mage Position Find Localzer Repeat Step Repeat & Open Step TP O SP R0.7 P2 MAGN/NORM/DIS2 Cogy Parameters FoV 220 220 Sac>Con(3)>Tre( 1) t1_qtoo_dark-nuld_sag_ 0Creato Snapshot 1188 520 Not for dia Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 36 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise GSP context menu: Shift to Image Plane 1. Shift to Image Plane – Moves center of all slices and slab groups into a defined reference plane a) Select reference image in GSP planning segment to be used as reference plane b) Right click > Select Shift to Image Plane from the context menu of the planning segment Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 37 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 c) Center of graphical object is moved into the reference plane and into the visible area of the image HAL Brain 2023.01.11-12:03:09-STD-1.3.12.2.1107.5.99.3 5 IMA 1 FRM 15/29 Bog Clear All Segments Shift to Image Planve ARF Group Graphics 15 Perpendicular Orthogonal 5cm Copy Image Position Find Localizer Repeat Stop Repeat & Open Stop TP O SP R0.7 FoV 220 220 P2 MAGN/NORM/DIS2 Copy Parameters Sag>Cor(3)>Tra( 1) tt_atse_dark- fluid_sag Create Snapshot W C 1188 529 Not for diagra 3.1 Examination UI - Queue Please learn more on PEPconnect: Outside US: Exam Workflow (siemens-info.com) US: Exam Workflow (XA30) Overview of the measurement queue 1. Series icon 2. Measurement time of sequence 3. Remaining overall measurement time Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 38 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 4. Toggle between Normal & Extended queue size 5. Opened protocol 5 Brain Dot Engine LOC + AAhead_scout 2 % t1_qtse_dark-fluid_sag_p2 3 t2_qtse_tra_p3 3 01:31 4 t2_qtse_dark-fluid_tra 04:14 5 resolve_3scan_trace_tra_p2_160 01:46 6 t1_mprage_sag_p2_iso 05:21 MPR planning t1_f12d_tra 3 01:19 2 4 E 14:11 HOT Go Cancel Delete Skip Stop Pause Continue Copy&Go Exercise Working man icon 1. Working man off – sequence runs automatically if next in queue 2. Working man on – indicates sequence needs to be planned a) Select a sequence in the queue, left click on the Working Man icon to toggle on or off Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 39 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Overview of the measurement queue 6. Selected Protocol – Bordered with white box 7. Measurement in Progress – Green 8. Completed Measurement – Black 9. Sequence not Executed in Queue 10. Copy Reference Flags Brain Dot Engine LOC . + 8 1 AAhead_scout 12 t1_gtse_dark-fluid_sag_p2 7 t2_qtse_tra_p3 3 01:12 W 6 4 t2_qtse_dark-fluid_tra 04:14 5 ep2d_diff_3scan_trace_p2 01:38 t1_#2d_tra 01:19 9 6 10 E 08:23 FO Delete Stip Stop Pause Go Cancel Continue Copy&Go Measurement queue – Contrast agent Exercise 1. Register patient and select Brain Dot Engine from the Workflow Simulation Tree Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 40 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 2. Select Contrast Agent > with contrast agent Exam Strategy Standard contrast agent with contrast agent Contrast Agent Pause & Contrast Agent icon in the toolbar Exercise a) The Contrast Agent window opens once you reach the inject contrast agent step > enter the information about the contrast agent being administered Brain Dot Engine LO HAL AHR Dee, Jine Doe, Jane AAhad scout RS_201402260313437 AS_201402200313487 OID OffweiPat 2 t1_gtse_dark-nuld_sag_p2 3/04/2022 3/24/2022 10 IMA1 FRM 36/192 7 IMA1 FRM 14/27 12_gtse tra_p3 12_qtse dark fluid_tra resolve_3scan_trace_tra_p2_160 11 mprage sag_02_10 MPR planning Exam Paused 11_112d_tra Inject contrast agent Patient has Contrast Agent (Vol. 0.00) 10 11_82d_tra 01:19 Agent Name Catalog ... Volume 0.00 ml 82 MAGINNORMOIS2D 1!__prage_sag -2-3% Total Dose 101:19 Active Ingredient Dilution Concentration mgiml Paytt Conteve Copykids Go Cancel Timing Injector Control Continue Close b) Click on the Contrast Agent icon next to the Patient name (e.g., Brain Dot Engine) > enter the information about the contrast agent being administered Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 41 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 LOC + General information • Contrast Agent Flag – Set for selected and all succeeding sequences in queue • Contrast Agent Catalog (e.g., created by customer) • Volume of Contrast Agent administered • Contrast Agent from Catalog – Select contrast agent from list Exercise 1. Add measurement program or program steps a) Register a patient with the Brain Dot Engine Workflow b) Select (+) icon on the toolbar c) Add Program/Steps Card opens d) Select Siemens or Customer exam database e) Select Program Tree > Region > Exam > Program Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 42 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 f) Depress left mouse on a sequence and drag into the queue Brain Dot Engine LOC & " + 1 AAhead_scout 2 t1_qtse_dark-fluid_sag_p2 t2_qtse_tra_p3 3 01:31 W 4 t2_qtse_dark-fluid_tra 3 04:14 5 resolve_3scan_trace_tra_p2_160 01:46 6 t1_mprage_sag_p2_iso 05:21 7 7 MPR planning t1_f12d_tra 01:19 9 inject contrast agent 10 t1_f12d_tra 01:19 E 15:30 Delete Go Cancel Skip K Stop Pause Continue Copy&Go Exercise Review of learned steps 1. Window images Window images slightly and reset window using a double middle mouse click (or) the lower right corner menu 2. Stamp segments Float mouse over stamp segment to see enlarged thumbnail 3. GSP segments – Maximize/minimize Overview segment Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 43 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 4. Identify the flyout toolbar 5. Context menu – review context menu options 6. Add a program or a sequence to the queue 3.2 Exam UI queue – Toolbars Queue – Protocol Control toolbar 1. Register patient and select Brain Dot Engine examination program 2. Measurement protocols are loaded to the queue: E 02:41 Go Cancel Delete Skip Stop Pause Continue Copy&Go a) Go to the Program Control toolbar icons below the protocols loaded b) Select a protocol in the queue and press Delete or grab the protocol and drag and drop to the bin: Eliminates current measurement(s) c) Right mouse on sequence 3 and Remove Copy References. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 44 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 d) Left click in front of sequences 3-6 and add a Working Man icon e) Select Go to run the localizer f) Select a sequence and press the Skip button to skip that sequence and continue to the next measurement g) Select protocol in the queue and press Copy&Go – Duplicates protocol and starts scan h) Prepare all protocols for measurement and press Go – Applies all changes made in the opened protocol i) Open protocol in the queue and select Cancel – Discards all changes made in the opened protocol Queue – Examination Toolbar Exercise 1. Register a patient and select the Brain Dot Engine examination program 2. Go to the Examination toolbar icons and review O SAR Stimu PTTySio Inline vetongs lesplay Display Dot Injector Settings Cockpit Control First Normal Level Mode Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 45 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 3. Select the Inroom Settings icon on the Examination toolbar Inroom Settings Inroom Settings Inform the patient about remote table movement. Monitor the patient during remote table movement. Current Position O 142 mm Move Table by mm Lock Table Close a) Please lock/unlock table – make sure that table movement is no longer possible b) Table Stop – Cancels table movement triggered by • Move Table by button • Home button • Center button c) Add a table value e.g., 270 – moves patient table precisely to the center of the measurement field d) Press Home Position icon - moves table out of magnet Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 46 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 e) Select Reset Position button - resets current table position to 0 f) Change magnet bore ventilation by sliding the marker up and down g) Adjust loudspeaker volume on the scanner h) Adjust headphone volume on the scanner i) Adjust lighting on the scanner • Bore lighting • Ring lighting (additional license) • Funnel lighting (additional license) Close Inroom Settings window. 3. Select Exam Settings icon on the Examination toolbar Exam Settings Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 47 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exam Settings ? X Table Move Show Notification Automatic Voice Commands Command Language English (United Stat ... Commands Duration Breathe evenly 3.85 Continue breathing. 2.7s Hold breath (exhaled). 6.3s Hold breath (inhaled). B.9s Hold breath as long as possible ( 9.75 Hold breath as long as possible ( 10.5s Shallow breathing 3.0s Sharp exhale 5.6s Short: Hold breath (exhaled). B.Os Short: Hold breath (inhaled). 3.1s Play Stop Playback 4 40 Close Exercise a) Select Table Move - Show Notification – Automatic table move warning message displayed, confirmation for table to move is needed when measurement is to be started b) Automatic Voice Commands - Controls selection and playback of voice commands stored → Available in 14 languages Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 48 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 c) Please set the voice output language to be played back in the Command Language row d) Commands list: List of patient instructions Please note: If an instruction is not available in the selected language, the speaker symbol and duration time are not displayed e) Start/Stop playback of selected instructions f) Adjust the voice output playback volume using the playback volume slider 4. Select Physio Display icon ECG IO 60 /min RR-1 1000 ms ECG IIO O SAR Stimu inroom Inline ettings Settings Display Display myExam Cockpit Injector Control First Normal Level Mode Displays signal type and number of signal tracks which can be selected by clicking on the arrow next to ECG l or ECG ll label Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 49 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 a) Modify triggering displayed • Click on the arrow next to the ECG Label > select ECG I, II, or III for physio triggering • One or Two Signals – click on arrow next to ECG > Remove Signal (or) select Two Signals (e.g., ECG, ECG + Pulse, etc.) b) Physiological signal curves • Click the arrow next to the gear wheel icon (Settings menu) in top right corner - Available options • Triggering procedure for individual signal curves • Display rate of all signal curves • Display of statistical values All ECG ECG I ECG II ECG III PULSE Beat Sensor Cardiac RESP External Signal External Signal Il Two Signals Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 50 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 In addition, if you wish to learn in more detail about ECG triggering, please follow the links to PEPconnect: Outside US: • MR Cardiac ECG Triggering - OUS (siemens-info.com) • Cardiac Essentials - PMU in MRI | Basics (siemens- info.com) US: • MR Cardiac ECG Triggering • Cardiac Essentials 5. Select the Inline Display icon automatically displays inline images: • Images reconstructed from a scanner • Graphics of a measurement • Window displayed in lower right corner • Scrolling through images is not possible Inline Display Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 51 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Register a patient and select Heart > Heart> Ventricular Function 2. Select Go to run the localizer and series 2-5 a) Open Inline Display to see the real acquisition of CINE images b) Right click in image area > Inline Display context menu opens c) Perform zoom/pan with middle mouse and then select Fit to Segment • Resets zoom/pan values of images displayed to fit segment size d) Select Image Text (on/off) • Removes or adds image text • Please note: Off recommended for real‐ time scanning e) Click on Clear Segment • Empties image area of Inline Display Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 52 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Fit to Segment Image Text (on/off) Copy Image Position oog Clear segment Step ? X Auto Save Save Pause Cop Continue Current Display Continue Position 6. Select Dot Cockpit icon Dot Cockpit a) Open/Close Dot Cockpit • Here you can find all the available examination trees and protocols 115? Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 53 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 To learn more, please follow the link on PEPconnect: myExam Cockpit and myExam Assist (Dot Cockpit and Dot Engines) (siemens-info.com) 7. Check SAR [Specific Absorption Rate]/Stimu [Stimulation (dB/dt)] icons • Opens/Closes SAR information dialog window SAR Stimu Normal Normal Mode Mode SAR Information SAR Monitor Operating Mode Current Measurement Next Measurement . Normal Mode . First Level Prediction Status Patient Protocol Current Displayed values belong to the last patient! SAR and Stimu Operating Modes: a) Normal Mode – SAR and dB/dt limits set to lower values Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 54 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 • Warming of patient kept to a minimum and simulation can be excluded. • Default operating mode. b) First Level Mode – controlled operating mode • SAR and db/dt limits set to higher values • Increased SAR values… • Increased db/dt….. General information: SAR/Stimu icons • Progress Bar – Indicates current level • Fill Level Progress Bar indicates the highest SAR and stimulation values of the current measurement and when they are getting to the critical limit • Percentage value displayed when moving mouse pointer over progress bar • Click arrow to open SAR information • Switch from Normal to First Level Mode SAR – Progress Bar color codes Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 55 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 • Red – Relative SAR value exceeds 100% • Green – Relative SAR value is below or equal to 100% To learn more, please follow the link on PEPconnect: Outside US: • Tips and Tricks for SAR and Stimulation Reduction Job Aid (siemens-info.com) • Safety information (siemens- info.com) US: • Tips and Tricks for SAR and Stimulation Reduction Job Aid • MRI Content - Safety Check Status Bar icons – lower right corner exam UI EN 9:56:39 PM Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 56 of 57 Job Aid | SmartSimulator Workbook | Basics: Scan UI Effective Date: 15 Dec 2022 | HOOD05162003319097 Exercise 1. Click on Server Load – Degree of utilization for available system resources - click to open Job View dialog window a) Select Storage Capacity – hard disc fill level. Float mouse over icon to display percentage value To learn more, please follow the link on PEPconnect: Outside US: System Messages and Message History (siemens-info.com) US: System Messages and Message History (XA30) To test your knowledge of Scan UI, we recommend taking an online self-assessment on PEPconnect: Scan UI Online Self-Assessment (siemens-info.com) Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Page 57 of 57