Important information for the MOBILETT Elara Max SmartSimulator
This PDF explains what you should consider in general when using the MOBILETT Elara Max SmartSimulator.
SmartSimulator Important information MOBILETT Elara Max – Radiography systems General information With the SmartSimulator MOBILETT Elara Max, you are able to experience a virtual training environment. The products are simulated on virtual machines on the cloud. There is no limitation on the number of virtual machines that can be used for training. SmartSimulator enables trainees to connect to the simulated product from their personal computers using the Internet. Trainings need to be scheduled in advance in SmartSimulator. The system is flexible and can accommodate changes in the training schedule. SmartSimulator trainings can be offered on your premises, or in the Siemens Healthineers training centers as trainer sessions or workshops. Help: For help or support, please click on the ? icon in the SmartSimulator booking portal. https://smartsimulator.siemens-healthineers.com PEX-Editor • Login: SIEMENS • Password: tcapmoc When the Examination tab is open, and the simulator is ready to perform the acquisition, please use the key combination CTRL+F8 on your keyboard in order to simulate the exposure. Unrestricted | Published by Siemens Healthineers AG I © Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 21 Apr 2023 | HILS 2224 Job Aid Effective Date: 23 Feb 2023 | QR700005629 Healthineers Job Aid | SmartSimulator – Important information Effective Date: 23 Feb 2024 | QR700005629 SmartSimulator allows you to experience a lof of the system’s functionality. However, please note that SmartSimulator is not an actual system, and therefore, it comes with some limitations. • Since no RIS is configured, only manual or emergency registration is possible. • The monitor on the actual system is a touch sensitive monitor. However on the SmartSimulator, you have to operate the monitor with a mouse. • Please note that examining might not result in the correct clinical image. However, these functions can be used for training purposes. • An internal archive node is set up. Once the transfer is completed however, the sending job will fail. • Do not use Remote assistance (SRS). You can click the button, but it will bring up an error. • All exposure programs are set to either Manual or AEC due to the virtual environment. • In examination, the configuration parameters of the system hardware have no effect on the image. They can be configured in the FLC UI (KVs and mAs). The parameters will not have any impact on the image. However, they will be seen on the image as image text with the configured value. The selected KVs and mAs values will also be available in the exam protocol. • For Quality Control (QC) tests, no appropriate images are linked. If you need to demonstrate this to customers, please bear in mind that only clinical images will be displayed. • Please be aware that the keyboard language is designed for English. The language can be changed to the different supported languages. • Some images from the examined Patients tab card appear white in postprocessing. • The functionalities Zooming an image continuously and Zooming an image to 1:1 pixel display in the Postprocessing tab card are not working. • Flipping is working for the 90° rotation, but arbitrary rotation is not working. • You have to click on the OGP (organ program) each time for acquisition (The simulator does not switch automatically to the next OGP). • The four-by-four view in the Documentation tab card is not fully operational, but the twin view is functioning. • The recycle bin is working for non-imported images. • Detector view is not possible. SIEMENS Unrestricted | Published by Siemens Healthineers AG I © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 2 of 3 Job Aid | SmartSimulator – Important information Effective Date: 23 Feb 2024 | QR700005629 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthineers AG I © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 3 of 3