
SmartSimulator general information - Overview, data and usage: MAGNETOM Sola Fit XA70A
This overview introduces the workflows and data available in your booked MAGNETOM Sola Fit system using the syngo MR XA70A software version in the SmartSimulator. It is based on general SmartSimulator information, workflow simulations, postprocessing data, and use cases.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)
SIEMENS Healthineers SmartSimulator general information Workflows, data and usage MAGNETOM Sola Fit XA70A smartsimulator.siemens-healthineers.com/ SIEMENS Healthineers MAGNETOM Solo Fit Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2025 Effective Date: 06 Aug 2025 | QR700026738 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Table of contents Table of contents 2 Foreword 3 Disclaimer 4 General information 5 Workflow simulations and use cases5 Postprocessing data and use cases15 Tips and tricks 19 Siemens tree protocols 19 Usage of contrast media 20 General tips and tricks 20 Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 2 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Foreword Dear participant, Welcome to the SmartSimulator overview list. This overview guides you through all available workflows and data within your booked MAGNETOM Sola Fit system based on the syngo MR XA70A software version in the SmartSimulator. Make the most of it! Have some fun and explore what it can do. The material in this Workflows, data and usage overview list is based on the general SmartSimulator information, available workflow simulations, postprocessing data and use cases. We hope you enjoy your SmartSimulator experience! Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 3 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always consult the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only, and shall by no means be regarded as a substitute for the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims, or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of these Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the latest information. The reproduction, transmission, or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration- dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 4 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 General information Workflow simulations and use cases WorkflowSimulation tree can be found and selected within myExam Cockpit - Explorer. myExam Cockpit - Explorer Explorer Browse Import Export X WorkflowSimulation SIEMENS USER WorkflowSimulation DEFAULT The WorkflowSimulation tree contains many different simulated workflows, which can be easily selected while registering and examining patients to simulate examination workflows in the clinical routine. The data for the simulated workflows was acquired on MRI scanners. All workflows are based on Siemens tree guided workflows, so-called myExam Assists, or proposed sets of program protocols from available Siemens tree. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 5 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 A dedicated set of examination regions is available; these are sorted alphabetically: myExam Cockpit - Explorer Explorer Pro Browse Import Export m X WorkflowSimulation Q Abdomen [Angio Assist > Ankle Brain Breast Implants > [] Breast [ Cardiac Flow [ Cardiac Manual Planning >[ C-spine [ Female Pelvis > [ Hip Bilateral > [ Hip Unilateral [ Knee 2D Knee 3D [L-spine > [ Pelvis male > [ Shoulder []T-spine > Ventricular Function [ Whole Body [ Whole Spine > [] Wrist Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 6 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 All the visible simulated workflows were scanned on volunteers and provide you with a real examination experience. Real images appear while scanning the data and correspond to the protocols available within the examination programs. Please note: If you change any protocol parameters within the available simulated workflows, this will not have any influence on output images. All the available simulated workflow images are hard-coded and cannot be changed or adapted in any way. Overview of the available simulated workflows and their usage: (1)Abdomen: Abdomen Abdomen Assist E LiverLab Assist El Abdomen Assist Liver Eval CB “Abdomen Assist Liver Eval CB” - represents dynamic liver MRI including simulation of liver iron quantification with breath-hold commands. “LiverLab Assist” focuses on liver - iron quantification only. Both available simulated workflows - and their post-contrast protocols do not contain contrast media injections, despite the possibility of Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 7 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 contrast media step selection and execution. (2)Angio Assist: Angio Assist thorax El test_bolus “Angio Assist test_bolus” represents - a chest/thorax angiography examination with a standard examination strategy. Contrast media images are - available within this workflow. This workflow is planned with test - bolus injection. (3)Ankle: Ankle Ankle E Routine right Ankle “Routine right Ankle” provides you - with a set of simulated protocols acquired on a right ankle which are frequently used in a routine ankle examination. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 8 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (4)Brain: y Brain Brain El Brain Assist []Brain Autopilot E program “Brain Assist” represents a routine - brain examination, based on an available standard strategy. “Brain Autopilot” represents an - examination which is completely covered by an Autopilot examination mode within the brain examination routine. Both available simulated workflows - and their post-contrast protocols do not contain contrast media injections, despite the possibility of contrast media step selection and execution. (5)Breast Implants and Breast: Breast Implants [] Breast E Breast Implants Assist [] Breast Breast E Breast Assist “Breast Implants Assist” and “Breast - Assist” represent MRI of the breast (tumoral) and MRI of the breast Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 9 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 with silicone implants based on 2 available examination strategies: o Fat Sat standard strategy o Fat Sat INTERVIEWS strategy Both available simulated workflows - and their post-contrast protocols do not contain contrast media injections, despite the possibility of contrast media step selection and execution. (6)Cardiac examinations: Cardiac Flow [Cardiac Manual Planning Cardiac Flow Assist Manual Planning E Cardiac Flow Assist El Planning Practice Ventricular Function Ventricular Function E Ventricular Function Assist “Cardiac Flow Assist” represents - cardiac MRI flow quantification. “Planning Practice” represents - cardiac manual slice planning and obtaining cardiac images. “Ventricular Function Assist” - represents MRI of the heart, based on a standard examination strategy. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 10 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (7)C-spine, T-spine, L-Spine, Whole Spine: C-spine [c-spine E c-spine Assist [ T-spine [t-spine El t-spine Assist [L-spine [] I-spine E I-spine Assist Whole Spine Whole Spine E Whole Spine Assist “c-spine Assist”, “t-spine Assist”, “l- - spine Assist” and “Whole Spine Assist” represent cervical, thoracal, lumbar and whole spine routine examinations, based on an available standard strategy. (8)Female and male pelvis: [ Female Pelvis [Pelvis male Female Pelvis Prostate Assist E Female Pelvis E Prostate Assist “Female Pelvis” represents a routine - examination of the female pelvis body part. “Prostate Assist” represents MRI of - the prostate, based on a standard examination strategy with axial slice orientation. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 11 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (9)Hip Bilateral: [ Hip Bilateral [ Hip Unilateral Hip Hip E Hip Bilateral Assist E Hip Right Unilateral Assist “Hip Bilateral Assist” represents a - routine examination of both hips, based on a standard strategy. “Hip Right Unilateral Assist” - represents a routine examination of the 2D right hip, based on a standard strategy. (10) Knee: Knee 2D Knee Assist Knee 3D El Right Knee general 2D knee [] Knee Autopilot El Right Knee 3D Assist E Right Knee program “Knee Assist – Right Knee general - 2D” represents a right knee routine examination, based on an available standard strategy. “Knee Autopilot – Right Knee” - represents an examination which is completely covered by an Autopilot examination mode within a right knee standard examination routine. “Right Knee 3D Assist” represents a - routine examination of the right knee, based on a 3D standard strategy. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 12 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (11) Shoulder: Shoulder []Shoulder Assist E Right Shoulder general 2D “Right Shoulder general 2D – - Shoulder Assist” represents a routine examination of the right shoulder, based on 2D standard and motion-insensitive (BLADE) strategies. (12) Whole Body: [ Whole Body Whole Body El Whole Body Assist “Whole Body Assist” represents MRI - of the whole body, based on a standard examination strategy. Please pay attention: - o Organ focus is not implemented while executing the examination. o Leg images were not included in the scan simulation, even though the Coverage parameter allows selection of the Legs segment while planning the examination in the examination queue. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 13 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (13) Wrist: [ Wrist [ Wrist E Left Wrist “Left Wrist” represents MRI of the - left wrist, based on a standard examination strategy. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 14 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Postprocessing data and use cases The Patient Browser function allows you to display a long list of image data. SIEMENS Healthineers O Patient Browser Patient Browser Local Data Search by Name, ID, Date, Description and Modality (Ctrl+F) Q The following data can be found within the Patient Browser: (1) Example images Results (137 results, 1:20:22 PM) Patient Name Accession Nu ... Study Description Sola_Fit_Ankle XA70A Comp_DRB_DRG_DRS_FA16ch_1.5T Skyra_Fit_Breast XAZOA Comp_DRB_DRS_Breast18ch_3T Skyra_Fit_Abdomen XA70A Comp_DRB_DRS_HASTE_Diff_BO18ch_SP32ch_3T Skyra_Fit_Head XA70A Comp_Swift_Brain_DRB_DRS_HN20ch_3T Skyra_Fit_Head XA70A Comp_DRG_DRS_Diff HN20ch_3T Skyra_Fit_Pelvis_male XA70A Prostate_Fast_ZOOMit_DRB_DRS_BO18ch_SP32ch_3T Sola_Fit Pelvis_male XA70A Prostate_Comp_DRB_DRS_ZOOMit_Pro_BO18ch_SP32ch_1.5T Sola_Fit_Abdomen XA70A Kidneys_Comp_ZOOMit_Pro_Diff_DRB_DRS_BO18ch_SP32ch_1.5T Sola_Fit_Breast XA70A Comp_Diff_DRB_DRS_Breast_18ch_1.5T Sola_Fit_L-spine XA70A Comp_DRG_DRS_SP32ch_1.5T Sola_Fit_Head XA70A Comp_Diff_DRB_DRG_DRS_HN20ch_SP32ch_1.5T Skyra_Fit_WB XA70A Comp_Diff_STIR_DRB_DRS_HN_20ch_BO18ch_SP32ch_3T Avanto_Fit_Knee XA70A Quick_2m_Knee_DRB_DRS_TxRx18ch_1.5T Avanto_Fit_Ankle XA70A DRB_DRS_FA16ch_1.5T Avanto_Fit_Shoulder XA70A Comp_DRB_DRS_SHA16ch_1.5T Avanto_Fit_WB XA70A Comp_Diff_DRB_DRS_BO18ch_HN20ch_SP32ch_1.5T Example images were acquired on different MAGNETOM systems with a dedicated syngo MR XA70A software version to provide you with a real impression of how the images might look on your system. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 15 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Image examples are available for almost all body regions, with different acquired techniques and coils – this information can be selected in the Study Description column. (2) Pediatric image examples Click on More Filters in the Patient Browser and enter *ped* under Study Description to display all available data relating to pediatric examinations. Patient Browser Local Data Search by Name, ID, Date, Description and Modality (Ctrl+F) More Filters Results (46 results, 9:43:31 AM) More Filters Patient Name Accession Nu ... Study Description Patient Name Last Name, First Name or Middle Name Prisma_fit_W-spine XA60A Ped_Comp_DRB_DRS_HN20ch Prisma fit Head XA60A Sinusitis Ped Face CE Gadov Patient ID Sola Heart XA31A Ped4y_Septal_wall_defect CE Sola Heart XA31A Ped11m_Septal_wall_defect Sola Neck XA31A Ped5m_Pathology_Dixon_HN1 Accession Number Sola Neck XA31A Ped20m_Pathology_CE_Dixon Sola Neck XA31A Ped11m_Pathology_RESOLVE Study Date and Time Sola Head XA31A Ped8m RESOLVE_MPRAGE HI From Sola Heart XA31A Ped9y_Pathology_CE Dyn_Re Sola Fit Heart XA51A Ped13y_ARVC_Beat_Sensor M To Lumina_Head XA50A Ped9y_Swift_CS-SPACE_HN20 v All day Vida_Extremity XA20A Ped7y_Leg_Cartilaginary_exo Altea_Extremity XA20A Ped_16y_Tibia_Fibula_Unilate Study Description *ped* X Lumina_Head XA20A Ped10y_epilepsy_HN20ch Lumina Knee XA20A Ped14y_Menisci_rupture_TxR Altea Abdomen XA31A Ped CBD stenosis MRCP BLA O + Prisma Head XA30A Ped3y_Post_OP_cerebreilum Search Save Work Add List Condition Aera Head XA30A Ped15y_Arachnoid_cyst_CE_H Prisma Head XA30A Ped4d Periventricular nod_heterotopia SMS Diff Ped16ch Germany_MA ... 7/22/2020 6/30 This is a collection of pediatric studies, acquired on different scanner types and different software versions. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 16 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (3) syngo.via image data sets Enter *MR_* in the search column within the Patient Browser to see all the available data for postprocessing with syngo.via tools, based on different body regions and pathologies. Patient Browser Local Data * MR * X Q More Filters Results (32 results, 9:52:45 AM) Patient Name Accession Nu ... Study Description MR_Prostate, PIRADS 000001 CUN MR Prostate pirads5 bilateral MR_Neurology VE11C Head_Sk_Hydrocephaly_Brain_morphometry_Current MR_Angiography VE11 Stenosis_carotis_interna_Sp_TOF_CE_HN16ch_SP24ch MR_Cardiac_Analysis XA10 Heart_Vi_Full_Case MR_BreVis KA10 Breast_Vi_Pathology_RESOLVE_Dixon MR_Angiography XA10 Peripheral_Vi_CE_Stenosis_3steps_PA36ch_S72ch MR_Neuro3D VE11 Head_Pr_Full_Case MR_Neuro3D VE11 Head_Pr_fMRI_DTI MR_Tissue4D VE11 Pelvis_Pr_Female MR_Neurology VE11 Head_Pr_Tumor_MeanCurve MR_Neuro3D VE11 Cervical_Pr_DTI_ZOOMit (4) Data sets with pathologies Patient Name Date of Birth Patient ID Study ID Referring Phys ... Study Descri ... Access .. Spectra_L-spine 01.01.1972 Spain_MAC_2aaaa 1066 2aaaa 1066 DemoCongress Discus pro .. VE11 Vida_L-spine 01.01.1964 Germany_MAC_3aaaa0301 3aaaa0301 Demo Disc protru ... XA10 Aera_Knee 11.08.2020 Germany_MAC_1aaaa3665 1aaaa3665 DemoCongress Meniscal t ... XA30A Free.Max_T-Spine 01.01.1968 USA_MAC_7aaaa0541 7aaaa0541 Demo Disc Herni ... XA40A Vida_Knee 29.03.1969 Siemens MAC_2aaaa2685 2aaaa2685 Demo Meniscal_ XA50A Lumina_Head 01.01.1972 Germany_MAC_2aaaa2483 2aaaa2483 DemoCongress TMJ discus ... XA50A Avanto_Fit_C-spine 01.01.1900 Germany_MAC_1aaaa4065 1aaaa4065 DemoCongress Disc-hernia ... XA50A Altea Knee 01.01.1942 Siemens MAC_1aaaa4459 1aaaa4459 DemoCongre ... Meniscal_t ... XA51A Sola Fit Knee 01.01.2022 Belgium_MAC_1aaaa4171 1aaaa4171 Demo Traumatic XA51A Free.Max Knee 01.01.1958 Germany_MAC_7aaaa0636 7aaaa0636 DemoCongress Meniscal_ XA60A Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 17 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (5) Dedicated View&GO data set Enter “View” into the search bar, select the data set and use the RMB (right mouse button) to select the “MR View&GO” workflow, which will then be loaded into the postprocessing viewing card. Patient Browser Local Data + View X Q More Filters Results (1 results, 10:19:54 AM) Patient Name Accession Nu ... Study Description View&GO Dataset <<<<<<< Open Ctrl+O <<<<<<< Open with Favorites <<<<<<< <<<<<<< View as Read-Only with Suggested Batch Open <<<< MR Oncology Assign Workflow MR Prostate * Cancel Workflow MR Spectro Search Patient with DICOM Q/R MR Tissue4D * Add to Demo List MR View&GO * Remove from Demo List MR Whole Spine * Set Mark state More Set Delete Protection state Set Archive state Remove Correction state New Examination Resume Examination Correct X Cut Paste Delete Del This data set provides you with the possibility to review and postprocess the data with all available MR View&GO tools. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 18 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Tips and tricks Siemens tree protocols The Siemens protocol tree provides a set of developed clinical examination protocols, covering all possible body regions and organs. These protocols can be used as the basis for creating, adapting and developing protocols in line with clinical needs and guidelines within your clinical department routine. When Siemens tree protocols are selected and loaded into the examination queue, you can easily press “Exam” but please be aware that no real images which correspond to the selected protocols will be displayed in the Graphical Slices Planner (GSP). Because this is a virtual environment, no image reconstruction will take place. Images which might appear in the GSP are placeholders which are displayed instead of black segment images. The visualization is hard-coded and cannot be changed. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 19 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Usage of contrast media Volunteers were used to create the simulated workflows. Usage of contrast media is not allowed. Exception: Angio Assist workflow. The anonymized data has been provided by one of our collaboration partners, who allowed us to use the images for education purposes. Contrast media injection can be simulated, however. General tips and tricks READ ME examination steps are implemented in many of the simulated workflows, providing some important information before starting the examination, and some in the middle of it. These steps were added manually to provide instructions and guide you through the necessary planning, with tips and tricks for the dedicated workflow execution. These implemented steps are visible either in the examination queue, when the patient is loaded, or in the myExam Cockpit in the WorkflowSimulation tree, when you select a program of interest. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 20 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 Here are some examples of different workflow guidance instructions: (1) Example of Abdomen Assist simulated workflow “Please READ me first!” implemented step: Abdomen Assist + 1 Please READ me firstl 2 localizer_bh 00:15 Guidance Please be aware of the following workflow limitations: - Post Contrast images were acquired on volunteers, Contrast Agent could not be injected. Only the Standard Strategy and Decisions provide output images and are included in the scan simulation. - Additional Strategies are Decisions included in the workflow demonstrate other workflow options. If modified in the scan simulation, some images may not be displayed, or incorrect images may be displayed. (2) Example of Angio Assist simulated workflow “READ ME” implemented step: Angio Assist ISO + 1 localizer_trufi_multislice 2 HASTE_tra_db_4bh_iPAT 3 READ ME - planning Test Bolus 4 Test_Bolus 00:57 Guidance Position the Test Bolus slice so the vessels of interest are completely covered - Drag & Drop the Test Bolus images into a GSP segment and scroll through the images until an image is seen with full intensity. The TTC (Time to Center) of these images correspond to the transit time. TTC is displayed as a comment at the bottom of the Test Bolus images. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 21 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (3) Example of Prostate Assist – Pelvis Male - simulated workflow “Please READ me first!” implemented step: Prostate Assist ISO *+ + 1 Please READ me firstl 2 localizer 00:15 3 % AA_Prostate_Segm 01:31 Guidance Please be aware of the following limitations: - Slice orientation "Axial" has been used for image acquisition. - AutoAlign for some steps could require manual adjustment. - Post Contrast images were acquired on volunteers, Contrast Agent could not be injected. In some of the workflows you might get a notification that “AutoAlign” for some steps could require manual adjustments. In such a case please slightly adjust the slice positioning manually and place the desired field of view (FoV – yellow planning box) over the area of interest. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 22 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 (4) Example of Ventricular Function Assist simulated workflow “NOTE – READ ME” implemented step when Step 4 Beat Sensor Training is set to “yes”: Ventricular Function Assist - LOC + localizer 00:03 2 % center on heart 3 localizer_heart 00:04 Beat Sensor Training yes 5 NOTE - READ ME 6 % Beat Sensor training fb 00:47 7 % thorax_cor_tra 00:38 When the “yes” flag is set for Beat Sensor Training, “NOTE – READ ME”, a manually created notification can be activated. When you double-click on Step 5, a dialog becomes visible: Name NOTE - READ ME Description - this is a simulation environment, please make sure the following: - Trigger source Beat Sensor/Trigger to be selected manually for each subsequent protocol -- > open protocol - Physio Card - Signal - 1st Signal/Mode -> Contrast agent admission Agent Name Catalog ... Active Ingredient Dilution Concentration Open Injector Control Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 23 of 24 SmartSimulator general information | Workflows, data and usage: MAGNETOM Sola Fit XA70A Effective Date: 06 Aug 2025 | QR700026738 To learn more about the usage of SmartSimulator, please refer to available workbooks, which guide you through the general functionalities of Basic Scan UI and MR View&GO features: E-Learning Platform: SmartSimulator Workbook - Basics: - Scan UI XA70 SmartSimulator Workbook - Basics: - MR View&GO XA70 Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, Page 24 of 24
- smartsimulator
- smart simulator
- smartsim
- XA70
- smartsim XA70
- xa70