Siemens Healthineers Academy

Smart Select (USA)

In this video you will learn how to use and configure the Smart Select feature.
Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)

Smartselect is a tool menu that allows you to activate and deactivate up to 8 different tools with minimal effort. It reduces the mouse movements necessary. To activate your most frequently used tools. In this video you will learn how to use and configure the Smartselect feature. Please keep in mind that the user interface may differ slightly on different host systems. To call up the smart select interface, press and hold the right mouse button on any image segment. After approximately one second, the smart select interface opens. Keeping the right mouse button pressed, move the mouse pointer towards the tool you want to select. After releasing the mouse button, the tool is activated and the smart select interface disappears. To use the tools activated with Smart Select, press the left mouse button. You can deactivate the selected tool by pressing escape on your keyboard. All the tools displayed in the interface are configurable. To configure the smart select interface, select the configuration icon located on the right top side in the smart. Select configuration dialogue. You can choose the following the tools that you want to display on the interface. How many tools? Should be available. Whether you want to use the quick tool selection mode called Expert mode. To start the configuration, choose whether you want the interface to contain four or eight tools. If you select four tools, the tools located in. The cardinal segments are capped. You can now adapt the tools available on the interface by dragging them from the list to the desired segments in the interface after pressing OK. The Smartselect interface is customized to your needs. You can also activate the Expert mode of Smartselect to invoke all tools using only mouse movements. In this case, the desired tool becomes active without opening the Smartselect interface. Open the Smartselect configuration and activate the Expert mode checkbox. Now press the right mouse button, quickly move the mouse in the direction of the tool you want to select and then release the button, for example to activate the distance line which. Is in the. Upper segment of the smart select interface, press the right mouse button, move the mouse upwards and release it to activate the scroll. Tool which is in the right segment of the smart select interface. Press the right mouse button, move the mouse to the right and release it. You can still open the Smart Select interface with the expert mode active. Simply press the right mouse button for approximately one second. Please note that when the expert mode is activated, right mouse click actions like image scrolling or rotating a VRT image are disabled. You can always. Access the context menu via a single right mouse button click. Remember, for calling up the smart select interface you need to hold down the right mouse button for one second.

2/22/2022 16 20 0.9 22 24 201 31 26 18 741 09 454 923 10. Smart Select This training material is based on the medical device syngo.via base VB60C. SIEMENS Vida_Breast Healthineers * 2/22/2022 F Australia_MAC _... Viewing MR general 11:08:09 AM 11:09:07 AM Series Name 23 IMA 1 FRM 139/224 Favorite Tools Result series: MR Basic Re Results Time Curve RIGHT BREAST SAG LEFT BREAST SAG CORONAL BREAST RIGHT BREAST Series LEFT BREAST Phase_01 SL Findings 10cm Printing SP F38.9 TE 2.5 FoV 361*250 TA 54.8 Tra BW 395.0 Zoom 1.73 p4 MAGN/M/NORM/DIS2D p4 MAGN/SUB/M/NORM/DIS2D W 741 Gadovist 14.00ml subtraction scale 1.0 5:24 AM Result series: MR Bas 2D Phase 05 TR 4.8 ick alle ges Marker Scroll Label t1_fl3d_tra_caipi_dynamic_SUB Result serie 10 ... RIGHT BRE CORONAL 10 .. LEFT BREA 3d1 / 10 syngo.via Scanner Al-Rad Companion Syngo Carbon View&GO Space Please keep in mind that the user interface may differ slightly from what is shown in this video. The actual usage of the tool may differ slightly on the different host systems, for example, on syngo.via, Syngo Carbon Space, syngo.via View&GO, Al-Rad Companion or on the scanner. However, the intended purpose of the tool is the same. The tool functionality defined in this video is applicable to any of the Siemens Healthineers products in which you find this tool. SIEMENS . Serles MR, Lesion_CE_Dixon Sen1 Result series: MR Basic Rei TR 48 TE 25 ₩ 923 t2_tse_fdixon_tra_p3 1 s t1_cor_pre_512_p4_DRB (1] Distance Line 22 cm Esc Results Viewing Smart Select Configuration Home Position Reset Layout Synch Config Align Timepoints Visual Alignment Automatic Registration Undo OK Tools Basic Interactions Zoom/Pan Rotate Movie [1] Distance Line Synch Number of Tools Q 4 Tools Align 8 Tools Expert Mode Tools are invoked directly by right-click, drag and release in the configured direction. Other features on right-click and drag will be disabled. Redo Cancel R 4.8 SP F E 2.5 FoV 361 W 395.0 Zoom 341p A 54.8 SP O 8 Tools Next Study Quick Guide Magnifier Display Types MPR Previous Study MPR Thick MPR/MPR 4 Tools MIP VRT VRT Thin Cinemat. VRT VRT Gallery Reset Preset Cinematic Insight Measurements Distance Line Distance Polyline Angle Angle on Stack Pixel Lens ROI Circle ROI Freehand ROI Auto Contour Assisted Perpendicular Orthomatic Lesion Quantification LungCAD Manual Calibration Annotations Arrow Text Ranges Parallel Ranges Radial Sliced Ranges Curved Ranges Curved R Nur es .22 cm W 925 5:26 AM W 9 Rotat Cance 5:27 AM 1_fl3d_tra_caipi_dynamic T Text Fit to Segment Exclude Timepo Enlarge Orientation Enlarge Series Show in MPR Insert and Propagate Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2023

  • smart select