ACUSON Sequoia™ Ultrasound System 2.5 (VA50) SW Release Auto Intima Media Thickness (Auto IMT) with Preview Function

This job aid describes the Auto IMT measurement feature available on the ACUSON Sequoia system VA50 software release with the preview function.

QuickReference Card Auto Intima Media Thickness (IMT) with Preview Function ACUSON Sequoia™ Ultrasound System (VA50) siemens-healthineers.com/sequoia HOOD05162003227904 · Effective date 10-Apr-2023 ... Using Auto IMT with preview function helps establish risk profiles, and to classify patients with intermediate vascular disease. SIEMENS Healthineers Step 1 – Per Label Configuration System Settings • Go to System Configuration Workflow Enhancement > Measurement & Report > Measurement Imaging Settings > Per Label Configuration Tab v Measurement & Report > Select Carotid exam type > Select Label to edit Measurement > Select default Tool and Method > Select Output values to Show Touch Screen Measurement Config > Select Display Units & Precision Custom Measurement Label Report OB Tables Carotid Dist CCA IMT Max Min Max Last Average Output Show Unit Precision C10 mm V 0.00 Max mm V 0.00 V Mean mm 0.00 Min mm V 0.00 Step 2 10L4 Select compatible transducer1 and Carotid exam Carotid • preset2 Step 3 – Acquire Images3 • Acquire image of distal carotid artery and bulb • Ensure the vessel image is perpendicular to the ultrasound beam and clearly shows the intimal lining Freeze • Press Freeze 1 Auto IMT with preview function is compatible with all linear transducers and the carotid preset. 2 If using the 18L6, be sure to add it to the Carotid preset. System Configuration > Workflow Enhancements > Image Preset > Image Preset Editor tab > Select Carotid preset > Select Add transducer > Select 18L6. 3 Imaging protocols may vary between institutions. 2 siemens-healthineers.com/ultrasound Step 4 – Measurement • Select Caliper on the control panel • Select an IMT measurement from touch screen x ... x Caliper Dist CCA IMT Step 5 – ROI • Roll trackball to position the dotted reference line and the ROI (region-of-interest) • Ensure the ROI is over a section of the posterior wall of the CCA Step 6 – Preview Mode • Press the Update (Preview) key on the control panel Update to enter the preview mode • Note the on-screen home base reference guide • Two blue lines will appear showing the tracings • Use the trackball to readjust the ROI position as needed, and the prior tracings will disappear Preview • Press Update (Preview) to enter Preview mode again Set Set • Press either Set key to enter Edit mode Cal 1 siemens-healthineers.com/ultrasound 3 Step 7 – Edit Mode • The more anterior trace will now remain blue, indicating the trace to be edited • The non-editable trace will be yellow • Move the tiny cursor and use either Set key to adjust the tracing of the line • Move the cursor towards the posterior tracing and that line will turn blue • Use either Set key to adjust the tracing of the line End Set Set Edit Step 8 – Save Measurements To enter measurement into report: Update • Press Image to store image and enter the measurement into the report Clip or • Press Update (End) to enter the measurement into the report PO Image 4 siemens-healthineers.com/ultrasound Step 9 – Reports Report • Press Report on the touch screen • The values seen will be the method Intima Media Thickness (IMT) chosen under the per measurement configuration tab Value Rt Dist CCA IMT Mean 0.96 mm Max 1.25 mm Step 10 – Edit Report Edit Report • Select Edit Report on the touch screen or monitor to see or delete individual measurements or to change the displayed - Intima Media Thickness (IMT) method in the report4 Mean Max Method • To delete a measurement, select the X next to a measurement Rt Dist CCA IMT 0.96 mm 1.25 mm Max • The drop-down method choices include: 0.96 1.25 X Last, Avg, Min, Max and the option to choose any of the prior individual 0.62 0.74 x measurements Method • Select Summary on the touch screen or monitor to return to the measurement summary page Max • Pressing Store Report will automatically save images of all report pages to the Last hard drive Avg Min Max 1 2 13 Summary 4 When the method chosen is Avg, only the Mean measurement is displayed in the report summary. Max and Mean are displayed in the summary report for all other methods. siemens-healthineers.com/ultrasound 5 For the proper use of the software or hardware, please always use At Siemens Healthineers, we pioneer breakthroughs in healthcare. the Operator Manual or Instructions for Use (hereinafter collectively For everyone. Everywhere. By constantly bringing breakthrough “Operator Manual”) issued by Siemens Healthineers. This material is innovations to market, we enable healthcare professionals to deliver to be used as training material only and shall by no means substitute high-quality care, leading to the best possible outcome for patients. the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest Our portfolio, spanning from in-vitro and in-vivo diagnostics to version of the software and hardware available at the time of the image-guided therapy and innovative cancer care, is crucial for training. The Operator Manual shall be used as your main reference, clinical decision-making and treatment pathways. With our strengths in particular for relevant safety information like warnings and in patient twinning, precision therapy, as well as digital, data, and cautions. artificial intelligence (AI), we are well positioned to take on the biggest challenges in healthcare. We will continue to build on Note: Some functions shown in this material are optional and might these strengths to help fight the world’s most threatening diseases, not be part of your system. improving the quality of outcomes, and enabling access to care. Certain products, product related claims or functionalities described We are a team of 66,000 highly dedicated employees across more in the material (hereinafter collectively “Functionality”) may not than 70 countries passionately pushing the boundaries of what’s (yet) be commercially available in your country. Due to regulatory possible in healthcare to help improve people’s lives around the requirements, the future availability of said functionalities in world. any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · HOOD05162003227904 · 13607 0423 online · Effective date 10-Apr-2023 ©Siemens Medical Solutions USA, Inc., 2023

  • Atherosclerosis
  • arteriosclerosis
  • Framingham heart study
  • Cardiovascular disease
  • CVD
  • stroke
  • intima-media thickness
  • intima media thickness
  • IMT
  • heart disease
  • area
  • cerebrovascular
  • ultrasound