ACUSON Sequoia 3.5 (VB30) Text Body Markers and Arrows
This document explains the Text, Body Markers and Arrows features using the ACUSON Sequoia ultrasound system.
SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Sequoia Ultrasound System Text, Body Markers and Arrows Release 3.5 (VB30) 1 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality 2 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 2 SIEMENS Healthineers Accessing Text SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Abdomen Patient Title Text SAG Update Imaging Callper Review RIGHT SAG PANCREAS AORTA PROX LATERAL Report LEFT TRV LIVER INC MID LLD End Exam ABC Image MIDLINE GB KIDNEY DIST CBD SPLEEN SUP HEPATIC V Job Status INF Freeze PORTAL VEIN MEDIAL Clear Screen Select Line Text Size Home Set Home 3 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To access the Text feature, press the ABC key on the Control Panel at the home base location. The text will be highlighted in orange on the Touch Screen. Note: If the body marker or arrow was used last, they will be displayed on the Touch Screen and will require you to select the Text tab. Notes No. 3 SIEMENS Healthineers Text Touch Screen SIEMENS. Healthineers ... System Configuration Tab Menu Hide Words Text Body Marker Arrow Exam Package Exam Packages Abdomen Patient Title/Text Title Text SAG Virtual Imaging Keyboard Active Text Review RIGHT SAG PANCREAS AORTA PROX LATERAL Report LEFT TRV LIVER IVC MID LLD End Exam MIDLINE GB KIDNEY DIST CBD SPLEEN SUP HEPATICV INF ob Status PORTAL VEIN MEDIAL Text Functions Clear Screen Select Line Text Size Home Set Home Next page H 4 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Once text is activated, the Touch Screen displays the text features. Tab Menu: This allows you to cycle between Text, Body Marker or the Arrow feature. Title/Text: Allows the user to choose a Title or Text annotation. System Configuration: Select the Configuration icon to access the configuration menu to customize the display of the text on the Touch Screen. Keyboard: Select the virtual keyboard icon to activate the digital keyboard for manual typing of text. Select the keyboard icon a second time to return to the previous screen of pre-defined text options. Hide Words: Temporarily removes Text and Title annotations from the Image Screen to take an image (e.g., teaching file). Select Hide Words icon a second time to regain text access. Exam Package (Text Annotation Packages) – Provides access to any pre-defined text from any Exam Package. Custom Text Annotation packages may be created in the System Configuration menu. The following actions adjust using the soft keys on the Control Panel as shown on the Abdomen exam text. • Clear Screen – Clears all “Text” on the Image and Touch Screen (also clears Measurements, Body Markers or Arrows). • Select Line – Returns the cursor to last text entered. • Text Size – Changes the size of all text and title annotations on the imaging screen. • Home – Moves the text cursor to the Home set position. • Set Home – Sets the desired location for text to appear on the Image Screen. The Delete key on the Control Panel removes a single word in a text line. It will delete the last word that was entered or, the user can move the cursor into the word they wish to delete and then press delete. Note: If no text is entered, Delete Line and Previous Application will be grayed out. Notes No. 4 SIEMENS Healthineers Text annotations SIEMENS. Healthineers ... Text Body Marker Arrow Exam Package Abdomen Patient Title Text Imaging Review RIGHT SAG PANCREAS AORTA PROX LATERAL Report LEFT TRV LIVER IVC MID LLD End Exam MIDLINE GB KIDNEY DIST CBD SPLEEN SUP HEPATIC V INF Job Status PORTAL VEIN MEDIAL Clear Screen Select Line Text Siz Home Set Home 5 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The Title feature allows the user to enter an annotation that will remain on the imaging screen in many scenarios. To use Title: • Select Title • Enter the desired label(s) • Select Text to return to the text function. The Title is not removed from the screen when the “Clear Screen” or “Delete” keys are selected while in “Text” mode. This feature is useful in situations such as OB exams with multiple fetuses. The user can enter the title “Fetus A” and continuously change or clear the anatomical text without affecting the title. • There are multiple preconfigured text groups available for customization. Additional groups may be added and may be customized to the user preference. • An Additional Text group is also available, seen arranged vertically but separated by spaces, and may be customized. This text group will add to the line of text rather than replacing text. Note: Only one word can be selected per vertical group or field of text in a consecutive line. Notes No. 5 SIEMENS Healthineers Text exam package SIEMENS . Healthineers ... Body Marker Exam Package Abdomen Patient Abdomen Carotid Cardiac Text Breast Imaging Digital GYN Fetal Echo Early OB Review RIGHT SAG Report LEFT MSK Neonatal Head OB Pediatric Abdomen End Exam MIDLINE LEA LEV Renal Pelvis Penile Prostate TCI Testis Job Status Thyroid UEA UEV Clear Screen Select Line Text Size Home Set Home 6 Unrestricted © Siemens Healthineers 2024 Speaker Notes: During an exam, to access text from another text annotation package, select Exam Package on the Touch Screen while in Text mode. A list of all exam types is displayed. Select the desired package from the Touch Screen to access the stored text. Notes No. 6 SIEMENS Healthineers Using the Text feature SIEMENS .... Healthineers ... Text Jody Marker Arrow Exam Package Abdomen Patient Title Text TRV LIVER Imaging Review RIGHT SAG PANCREAS AORTA PROX LATERAL Report LEFT TRY LIVER INC MID LLD End Exam MIDLINE GB KIDNEY DIST CBD SPLEEN SUP w wiVv HEPATIC V INF PORTAL VEIN MEDIAL Clear Screen select Line Text Siz Home Set Home 7 Unrestricted © Siemens Healthineers 2024 Speaker Notes: • Once the Text feature is activated, the Touch Screen displays the pre-defined text. • Available text on the Touch Screen is white and becomes orange when selected. • Active text on the image screen is green and becomes yellow when set. • To change text, select a different word and it will replace the existing text (text replace fields only). • Temporarily hide annotations by selecting the Show/Hide control. Note: The control color is orange when text is hidden. To redisplay hidden text, select the Show/Hide control again. • Only one word from each group or field can be selected in a consecutive line of text. Notes No. 7 SIEMENS Healthineers Entering manual text SIEMENS. Healthineers ... Text Body Marker Arrow Exam Package Abdomen = Patient Title Text TRV LIVER Imaging Review Report End Exam 6 & 9 Tab W E Y U Caps Lock S D F G H L Enter Shift 2 X C V IN M Delete Ctrl Alt #+- Clear Screen Select Line Text Size Home Set Home 8 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To manually enter text using the digital keyboard, press the ABC key on the Control Panel, then select the Keyboard icon on right side of the Touch Screen. Use the cursor or select a letter on the Touch Screen. When Caps Lock is on, it is orange in color. When Caps Lock is off, the key is gray. The default is Caps Lock off. If Auto-Complete is stored in the System Configuration (Configuration > Annotation> Text), the system displays a matching phrase from the exam-specific library of text annotations based on the first few letters entered and it is displayed in orange. • To accept, select the Tab key. • To delete, press the Delete key on the Control Panel. • Press the space bar to remove the pre-defined text or continue typing. Once accepted, users can roll the trackball to the end of the word and backspace, the auto- complete word reappears for easy editing. Notes No. 8 SIEMENS Healthineers Entering text with optional retractable keyboard SIEMENS. Healthineers ... * 9 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The system has an optional retractable keyboard. To type manual text, press Text Start (space bar). Notes No. 9 SIEMENS Healthineers Moving and editing text SIEMENS .... Healthineers ... 14L5 15L4 Carotid TIB:0.27 NB:0.07 TIC:0.67 C:0.23 TIS:0.27 IS:0.07 MI:1.04 MI:0.65 19fps 36fps 95% 95% 2D H Mid H Mid 0dB/DR65 0dB/DR55 UA 2 c=1540 LD 2 MapD/T5 UA 3 wapC/T5 5dB/General PRF 3906 RT CAR| BIFURCATION 3.5cm RIGHT SAG THYROID 10 Unrestricted © Siemens Healthineers 2024 Speaker Notes: • Text can easily be edited by selecting a different choice on the Touch Screen. • To edit text manually, place the cursor in the desired area and select the backspace key. • To move the text, place the cursor in the text and press the Set key. The line of text becomes teal and can be moved anywhere in the image screen. • Once set, the annotation becomes yellow. Notes No. 10 SIEMENS Healthineers Text overwriting SIEMENS. Healthineers ... Text Body Marker Arrow Exam Package Carotid Patient Title Text LEFT 4 Imaging Review 1 RIGHT SAG PROX CCA UGULAR Report LEFT TRV MID BULB SUBCLAVIAN nd Exam DIST BIFURCATION ICA ECA VERTEBRAL Clear Screen Select Line Text Size Home Set Home 11 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To overwrite text on a stored image: 1. Select Review on the Touch Screen. 2. Select the image to correct. 3. Position the cursor before the first character of the first word to overwrite. 4. Select the Overwrite Control on the Touch Screen. 5. Use the keyboard or insert or delete characters or press the desired label from the Touch Screen. 6. Press a trackball key to confirm the text. Note: To fully overwrite existing text, the temporary label must be the same length or longer than the original text. If not, then use the space bar to space until the word is covered. Notes No. 11 SIEMENS Healthineers Text customization SIEMENS . Healthineers ... System Configuration Create Package > System Settings 2 5 . Workflow Enhancement Package Configuration Touch Screen Layout Editor > Imaging Settings All Packages Package Name Package Name Carotid Dr. A · Measurement & Report Name Show All v Abdomen Annotations Abdomen Root Package 4 Carotid Body Markers All Packages Text 1 Auto Complete 6 > Features Delete text on unfreeze Auto text con Transducer OK Cancel > Connectivity & Network > Peripheral Devices Fetal Echo 7 System Management Early OB MSK Neonatal Head Pediatric Abdomen LEA LEV Renal 3 Create Package Import Export Restore Defaults 12 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To create a new text package: 1. Enter System Configuration > Annotation> Text. 2. Select the Package Configuration tab. 3. Select Create Package. 4. Enter a Package name and a Root package (copy), if desired. 5. Select the newly created package from the Package Configuration tab. 6. The Auto text complete option enables the system to choose to display a word found within the active Exam Package and completes it after typing the first few letters. 7. The Delete Text on Unfreeze option activates the removal of all on-screen text after unfreezing the image. Notes No. 12 SIEMENS Healthineers Text customization SIEMENS. Healthineers ... System Configuration System Settings 1 > Workflow Enhancement Package Configuration Touch Screen Layout Editor >Imaging Settings 4 Text Annotation Packa > Measurement & Report Abdomen 2 Add Text Group Add Text 5 6 Annotations Body Markers < > < > + < >+- Text RIGHT SAG PANCREAS AORTA ATERAL > Features > Transducer LEFT TRV LIVER IVC MID LLD > Connectivity & Network > Peripheral Devices MIDLINE 3 GB KIDNEY DIST System Management CBD SPLEEN SUP HEPATIC V INF PORTAL VEIN MEDIAL New Page 7 Delete Page 1of2 › Restore Defaults : Abdomen 13 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To customize the Touch Screen appearance of the text menu: 1. Enter System Configuration > Annotations > Text > Touch Screen Layout Editor. 2. Select the desired Text Annotation Package. 3. Position the cursor in any text box to add/replace the text label. 4. Select Add Text Group to add a new text group or replace group. 5. Select Add Text to add a new additional text group (non-text replace). 6. Use the controls at the top of each group to reposition the group (), delete the group (X) or add or remove columns within the group (+/- ). 7. Select New Page to add an additional page of text annotations or Delete Page to remove additional pages. Notes No. 13 SIEMENS Healthineers Text customization SIEMENS .... Healthineers ... Text Body Marker Arrow Exam Package Abdomen 18L6 General TIB:1.10 Patient TIC:0.67 TIS:0.47 Title Text MI:0.38 Imaging 31fps 2D Review H High RIGHT SAG PANCREAS AORTA PROX LATERAL -2dB/DR60 LD 2 Report UA 3 LEFT TRV LIVER INC MID LLD MapD/T4 P2 End Exam MIDLINE ABCDEFGHUKLMN c OPQRSTUVWXYZ GB KIDNEY DIST Mid -11dB/High P3/LD3 CBD SPLEEN SUP ABCDEFGHUKLMNOPQRSTUVWXYZABCD PRF 7813 MapF/F2 2.8cm HD Z 18mm 60 S2/Pr4 HEPATIC V - 150 2D + Color D PW ORTAL VEIN MEDIAL - 100 Mid -8dB/DR70 MapD/T9 -50 GS 1.0 Clear Screen Select Line Text Size PRF 7813 Home Set Home F 352 14 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Additionally, you can program long single lines of text (30 character maximum). Note: Approximately 26 characters will be displayed on the Touch Screen (depends on width of character), but the entire word will be on the image. In this example, there are 30 characters displayed on the image. Multiple words can also be used with spaces and will not be affected by auto complete configuration Notes No. 14 SIEMENS Healthineers Objectives SIEMENS .... Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality 15 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 15 SIEMENS Healthineers Accessing Body Markers SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Patient Update Imaging Callper Review Report End Exam ABC Image Freeze Clear Screen Trackball Transducer Marker On 16 Unrestricted © Siemens Healthineers 2024 Speaker Notes: • To access the Body Markers, press the ABC key on the Control Panel at the home base location • On the Touch Screen, select the Body Marker tab • This is an example of the MSK body marker selections Notes No. 16 SIEMENS Healthineers Body marker Touch Screen layout SIEMENS. Healthineers ... Text ody Marker Arrow Exam Package Carotid Tab Menu Imaging Oo Review Report Transducer nd Exam Delete Widget X Clear Screen Trackball Soft Keys Transducer Marker Transducer Marker On 17 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The tab menu is highlighted in orange when the Body Marker is activated. The active exam body markers are displayed. The soft key function include: • Clear Screen – deletes all Body Markers, Text and Arrows displayed on the image screen. • Trackball – allows two different functions: • Body Marker: activates the body marker so that it can moved. • Transducer Marker: activates the transducer marker so that it can be moved. • Press the Soft Key or Touch Screen to alternate between Body Marker and Transducer Marker. • Body Marker – activates the Body Marker on the image screen. • Transducer Marker – turns the Transducer Marker on and off. The transducer widget allows movement and rotation of the Transducer Marker. Place your finger or cursor in the orange circle or on the Transducer Marker and move to the desired location. When in the body marker tab, pressing the Delete key on the Control Panel removes the Body Marker from the image screen without removing Text or Arrows. Notes No. 17 SIEMENS Healthineers Selecting Body Markers SIEMENS .... Healthineers ... Text Body Marker Arrow Exam Package Carotid Carotid TIB 0.57 TIC 1.29 T10:0 57 MI:1.20 Patient 10fps H Md Imaging 0GB/DROO Oo Pen Review 4di/ General M PRF 2076 Report End Exam RIGHT BIFURCATION 1 × 6 Clear Screen Trackball Transducer Marker ransducer Marker On 18 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Once you have pressed the ABC key on the Control Panel, the Touch Screen displays the active exam as shown in the left screen. To choose a Body Marker, select the Body Marker tab on the Touch Screen. The body marker is displayed from the last position as shown in the image. To move the body marker location, push the Soft Key labeled Body Marker, and the body marker becomes active (orange), then use the trackball to move to the desired location. To activate the transducer marker, push the Soft Key Transducer Marker to the “On” position. To reposition, use the Transducer Marker diagram on the Touch Screen: • Drag the orange dot on the Touch Screen to change the orientation of the transducer marker. • Drag the transducer marker to change its position. To delete a body marker from the image screen, press Delete on the Control Panel. To add a body marker from another application, select Exam Package and select the desired exam and make the selection on the Touch Screen. To remove all Text, Arrows and Body Markers from the image screen, select Clear Screen on the Touch Screen. To exit the body marker function, press the ABC key on the Control Panel. Notes No. 18 SIEMENS Healthineers Body Marker configuration SIEMENS. Healthineers ... System Configuration . System Settings 2 >Workflow Enhancement Package Configuration Touch Screen Layout Editor Imaging Settings Body Marker Package Package Name > Measurement & Report Name Show All v Abdomen Annotations Abdomen 1 Body Markers Carotid All Packages 4 Text Body Marker Behavior Features El Delete Body Markers on unfreeze 6 Create Package Transducer 5 > Connectivity & Network > Peripheral Devices Fetal Echo Package Name Carotid Dr. A > System Management Early OB Root Package MSK Carotid Neonatal Head Pediatric Abdomen OK Cancel LEA LEV 3 Create Package Import Export Restore Defaults 19 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To create a new text package: 1. Enter System Configuration > Annotation> Body Markers Select. 2. Select the Package Configuration tab. 3. Select Create Package. 4. Enter a Package name and a Root package (copy) if desired. 5. Select the newly created package from the Package Configuration tab. 6. The Delete Body Markers on unfreeze option activates the removal of all body markers after unfreezing the image. Notes No. 19 SIEMENS Healthineers Other Body Marker configurations SIEMENS . Healthineers ... Package Configuration Touch Screen Layout Editor 1 Package Configuration Touch Screen Layout Editor Body Market Package Testis 2 Body Marker Package Testis Body Marker Utwary Body Market Literary Renal 3 Renal 5 4 Click here to remove 6 New Page 8 Restore Defaults : Testis New Page 7 20 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To configure the body marker menu Touch Screen layout: 1. Select System Configuration > Annotation > Body Marker > Touch Screen Layout Editor. 2. Select the desired Body Marker Package you wish to edit from the drop-down menu. 3. Select the desired Body Marker Library you wish to add from. 4. Select the desired Body Marker from the available options. 5. Select the desired location to place the body marker. 6. To remove a body marker from the Touch Screen, select the desired body marker and select the box labeled “Click here to remove”. 7. Selecting New Page on the Touch Screen adds a second page where additional body markers can be added. 8. The Restore Defaults key deletes the customized body marker selections and restores the factory default settings. In this example, we are adding a body marker from the renal Library(3). This can be added to use as a body marker for urology patients. Notes No. 20 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality 21 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 21 SIEMENS Healthineers Accessing the arrow feature SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Patient Update imaging Review Callper Report End Exam ABC Image Freeze Clear Screen Previous Arrow 22 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To access the Arrow feature, press the ABC key on the Control Panel at the home base location. Next, select the Arrow tab from the Touch Screen. Notes No. 22 SIEMENS Healthineers Using the Arrow feature SIEMENS .... Healthineers ... Text Body Marker Arrow 1 Exam Package Patient Imaging Review Report End Exam 4 Add Arrow 2 3 lear Screen Previous Arrow Position Tail 4 23 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Access the Arrow function by pressing the ABC key on the Control Panel. 1. On the Touch Screen, select the Arrow tab and the active arrow displays in orange. 2. Selecting Clear Screen clears all arrows. • This will also delete all text and measurements on the screen. • To delete just the arrows, press the Delete key on the Control Panel to delete one arrow at a time or hold down for 1.5 seconds to clear screen. 3. To move between arrows, press Previous Arrow on the Control Panel soft key or on the Touch Screen. 4. There are two ways to increase the length of the arrow: • Drag the tail of the arrow on the Touch Screen to increase/decrease the size of the tail. • Use the trackball and Set key to position and increase/decrease the size of the tail. To add Arrows, press the Update key on the Control Panel. To rotate or angle the arrow, drag the tail of the arrow on the Touch Screen widget to change the direction. Notes No. 23 SIEMENS Healthineers Trademarks and disclaimers SIEMENS. Healthineers ... The ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. 24 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 24 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS. Healthineers ... Questions? 25 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 25
- Text
- Body Markers
- Arrows