ACUSON Sequoia™ 3.5 VB30 System Overview Quick Card

This document will help the user understand the system overview using the ACUSON Sequoia™ ultrasound system.

Quick Card General System Overview ACUSON Sequoia Ultrasound System 3.5 (VB30) siemens-healthineers.com/sequoia 1 2 3 4 5 8 9 7 10 6 11 Update 12 18 23 17 17 15 x ... x Caliper Clip 20 13 14 24 19 25 Delete Dual 16 ABC Image 21 22 xt Freeze 1. Power 10. 2D-mode 19. Trackball 2. Soft Key Rotary Controls 11. User-defined 20. Clip 3. DGC Controls 12. Pointer 21. Image 4. Contrast 13. Forward/Backward 22. Freeze 5. Virtual Touch (Elastography) 14. Delete 23. Zoom 6. 3D/4D (Future Use) 15. Caliper 24. Depth 7. M-mode 16. Text, Body Marker, Arrow 25. Dual 8. PW Doppler/CW Doppler 17. Left/Right Set 9. Color Doppler 18. Update SIEMENS Healthineers . 1 2 17 ? 5Z1 11M2 5C1 Abdomen Workflow 4 Patient 2D 3 5 Imaging 13 14 15 16 Al Abdomen L/R Flip U/D Flip Biopsy 6 Review Off Timer 7 Report Panoramic Full FOV 18 19 8 End Exam 20 21 22 23 9 Auto TEQ Live Dual Clarify Off 10 Harmonics Compounding Wide FOV 11 24 25 26 12 27 Frequency DR InFocus Line Density 28 Mid 55 dB 2 1. System Configuration 11. Pointer 21. Auto TEQ 2. Transducers 12. Additional Selections 22. Live Dual 3. Imaging Modes 13. AI Abdomen 23. Clarify Vascular Enhancement 4. Patient Registration 14. L/R - U/D Flip 24. Harmonics On/Off 5. Imaging Menu 15. Biopsy Mode 25. Compounding On/Off 6. Review 16. Timer 26. Wide Field of View (Wide FOV) 7. Report 17. Workflow Applications 27. Soft Key Options 8. End Exam 18. Panoramic Imaging 28. Page Navigation 9. Print 19. Full Field of View (Full FOV) 10. Full Screen 20. UltraArt General Operation Getting Started Measurement • Press Patient to enter the patient registration page Press x .. . x • Caliper to enter the measurement package • Select the patient name from the worklist or manually • enter patient information Select the measurement label or type from the Touch Screen • Select the transducer and exam from the Touch Screen • Position calipers • Press Set key to complete the measurement 2 siemens-healthineers.com/ultrasound 2D Imaging Text/Body Markers/Arrows Press 2D • to enter B-mode imaging • Press ABC to activate the text menu • Rotate 2D to increase/decrease gain • Select annotations from the Touch Screen • Additional optimization selections are available on the • Touch Screen Select to activate the digital keyboard • Select Body Marker to activate Body Markers • Select Arrow to activate Arrows Color/Power Doppler • Press C to enter color Doppler Image Management • Select Power to enter Power Doppler • Press Image to store an image • Rotate C to increase/decrease gain • Use the Trackball controls to change the position/size of the Region of Interest (ROI) • Press Clip to store a clip • Select Report to view and edit the Report M-mode • Select Review to review stored images/clips on active exam • Press M to enter M-mode • Select End Exam to end the exam • Use the Trackball controls to set the position/size of the sample line Restart a Study (within 24 hours) PW/CW Doppler • Select Patient and then Patient Browser • Select Local Database PW • Press to enter PW/CW Doppler CW • Select the patient and select Append Study • Move the Trackball to position the PW cursor • Use the Soft Key options to change the gate size, scale, baseline, and filter PW • Rotate to increase/decrease gain CW Active, Discontinued, Paused, and Completed Studies • An Active exam will show a green play icon • A Discontinued study will show a gray X icon X • A Paused study will show a yellow pause icon • A Completed study will show a gray check mark icon V siemens-healthineers.com/ultrasound 3 Please note: At Siemens Healthineers, we pioneer breakthroughs in healthcare. For the proper use of the software or hardware, please always use For everyone. Everywhere. Sustainably. As a leader in medical the Operator Manual or Instructions for Use (hereinafter collectively technology, we want to advance a world in which breakthroughs “Operator Manual”) issued by Siemens Healthineers. This material is in healthcare create new possibilities with a minimal impact on to be used as training material only and shall by no means substitute our planet. By consistently bringing innovations to the market, the Operator Manual. Any material used in this training will not be we enable healthcare professionals to innovate personalized care, updated on a regular basis and does not necessarily reflect the latest achieve operational excellence, and transform the system of care. version of the software and hardware available at the time of the Our portfolio, spanning in vitro and in vivo diagnostics to image- training. The Operator Manual shall be used as your main reference, guided therapy and cancer care, is crucial for clinical decision- in particular for relevant safety information like warnings and making and treatment pathways. With the unique combination of cautions. our strengths in patient twinning1, precision therapy, as well as Some functions shown in this material are optional and might not digital, data, and artificial intelligence (AI), we are well positioned be part of your system. to take on the greatest challenges in healthcare. We will continue to build on these strengths to help overcome the world’s most Certain products, product-related claims or functionalities described threatening diseases, enable efficient operations, and expand in this material (hereinafter collectively “Functionality”) may not access to care. (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in We are a team of more than 71,000 Healthineers in over 70 countries any specific country is not guaranteed. Please contact your local passionately pushing the boundaries of what is possible in Siemens Healthineers sales representative for the most current healthcare to help improve the lives of people around the world. information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. 1 Personalization of diagnosis, therapy selection and monitoring, after care and managing health. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700011740 · 15686 1124 online · ©Siemens Medical Solutions USA, Inc., 2024

  • system overview
  • monitor
  • wheels
  • touch screen
  • keyboard
  • imaging screen