Siemens Healthineers Academy

Improve Diagnostic Confidence in Liver Health - Poster

Please note that the learning material is for training purposes only!
 
For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
 
The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions.
 
Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases.
 
Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information.
 
ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc.  Copyright © Siemens Healthcare GmbH, 2022
 
“Some of the indications on the use of CEUS may be off-label in some countries. Users shall always refer to the national SPC’s (Summary of Product Characteristics) or PI (product Information for the USA) which are the official product labelling approved by the Regulatory Authorities”

Improve Diagnostic Confidence in Liver Health siemens-healthineers.com/ultrasound 10595 0421 · ©Siemens Medical Solutions USA, Inc., 2021 2 Liver assessment using gray scale ultrasound findings 7 8 4a 1 alone can be difficult. Remove subjectivity to improve 3 diagnostic confidence by displaying quantitative tissue 4b stiffness properties using Virtual Touch technology. 6 5 The degree of tissue stiffness has been shown to correlate with the progression of liver fibrosis. Absent or mild fibrosis Significant fibrosis Severe fibrosis Cirrhosis Metavir Score F0–F1 F2 F3 F4 Siemens Healthineers 1.2 m/s 1.3 m/s 1.5 m/s 1.7 m/s values† 4 kPa 5 kPa 7 kPa 9 kPa 1.3 m/s 1.7 m/s 2.1 m/s Society of < 9 kPa rules out cACLD in the Radiologists in Not applicable Ultrasound (SRU)†† < 5 kPa Likely Normal absence of other clinical signs > 13 kPa rules in cACLD 9–13 kPa suggestive of cACLD needs further testing 10 sample median; IQR/Median < 15% m/s, < 30% kPa. cACLD = compensated Advanced Chronic Liver Disease. This guide is based on meta-analysis and clinical studies using Siemens Healthineers Ultrasound. This guide is not intended to be used as a conversion table for liver stiffness readings to fibrosis stage or replace the performing physician’s judgment for the final diagnosis. Rev: April 2021 †, †† Data on file. Technique: spin-5.8 cm • Fasted patient lies in a slight left lateral decubitus position • Place ROI optimally within segment 5 or 8 of the liver. Avoid increased subcapsular reverberation by placing the ROI perpendicular to and at least 1.5–2 cm below the liver capsule. This can be achieved by placing the 2 cm cursor depth marker on the liver capsule. • Instruct patient to maintain shallow, brief breath hold • Obtain 10 measurements at the same site a. At least 6/10 of measurements should be “valid” as indicated on the bottom of the screen, as seen here Site 1: 0 Valid/0 Total b. IQR / Median ratio of ≤ 0.15 (m/s) and 0.3 (kPa) is the recommended quality control measure for adequate technical quality (as calculated on the report page IQR/Median ) For more information, please visit siemens-healthineers.com/ultrasound or contact your local Siemens Healthineers sales representative. SIEMENS Healthineers

  • pswe
  • dax
  • udff
  • liver
  • best practices
  • fibrosis
  • steatosis
  • hepatic