ACUSON Sequoia 3.5 VB30 General Imaging Onscreen Measurement and Report Presentation
This document explains how to use the GI Onscreen Measurements on the ACUSON Sequoia ultrasound system.
SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Sequoia Ultrasound System Measurements & Reports (Onscreen) 3.5 (VB30) 1 Unrestricted © Siemens Healthineers 2025 Speaker Notes: No speaker notes. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Identify access to measurement feature and screen information • Explain editing and deleting measurements • List exam specific measurement options • Examine report access, layout and editing • Outline printing options 2 Unrestricted © Siemens Healthineers 2025 Speaker Notes: This presentation will teach the user how to use the measurement function on the ACUSON Sequoia ultrasound system. We will begin by explaining how to access the measurement function and discuss which information is contained on both the Touch Screen and imaging screen. Image: HOOD05162003330011 Notes No. 2 SIEMENS Healthineers Accessing measurement feature SIEMENS . Healthineers ... O Caliper Update ABC 3 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To access the caliper function, press the Caliper key on the left side of the trackball. Measurement access is available during all examinations on real-time, frozen, and Cine images. Notes No. 3 SIEMENS Healthineers Touch Screen display layout SIEMENS . Healthineers ... General Abdominal Vascular Renal Vascular Exam Package Main label Abdomen groups Patient Imaging Review Hepatoportal/TIPS Aorta-Iliac Liver Transplant Mesenteric Report Liver Stent-Portal End Spleen End Exam Label sub-groups Portal V Stent-Mid Splenic V CHA Stent-Hepatic End IVC O Distance Ellipse 2D Trace Open Trace %Stenosis-A %Stenosis-D Volume Depth More Clear Screen Edit Caliper Hide Results Select 4 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The measurement menu displayed is fully customizable for all exams except cardiac. Configuration of the measurement screen layout is found in System Configuration > Measurement & Report > Touch Screen Config and covered in a separate presentation dedicated to measurement configuration. When the measurement function is activated, the Touch Screen displays the label groups and sub- groups that are available within the chosen exam package. Each group or sub-group contains labels that are organized by mode type, such as renal vascular, or exam type, such as liver transplant. To use a labeled measurement from the Touch Screen: • Activate the caliper function by pressing the Caliper key • Select the label you wish to use from the Touch Screen – the system then activates the measurement tool associated with the chosen label • Position and anchor the beginning and ending measurement markers using the trackball and Set key Labels can also be added to a measurement that has already been anchored on the screen by selecting the label from the Touch Screen once the “generic” measurement has been completed. The measurement will be “labeled” if the selected measurement label supports the chosen generic measurement tool. If the measurement label does not support the generic measurement tool, the ultrasound system will activate the measurement tool that is associated with the chosen label. In this instance, you must re-measure the object onscreen. Notes No. 4 SIEMENS Healthineers Touch Screen display layout SIEMENS . Healthineers ... General Abdominal Renal Vascular Exam Package Vascular Abdomen Right/Left options are Patient Right Left displayed on Imaging every page Review Abdomen Miscellaneous Report Prox Aorta Liver Spleen Kidney Pre-Void Bladder IVC End Exam Modifiers are embedded - 00:11:43 Mid Aorta Pancreatic Duct GB Wall Thickness Cortical Thickness Post-Void Bladder AI Measure within labels Tool Dist Aorta CBD CHD O Distance Ellipse 20 Trace Open Trace %Stenosis-A %Stenosis-D Volume Depth More Clear Screen Edit Caliper Cine Hide Results Select 5 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Modifiers for right and left are displayed on each page of the Touch Screen, allowing the user to advance through the pages without returning to another page to label the laterality. Modifiers, such as proximal and distal, are embedded in the Touch Screen labels. AI Measure rulers will be available with the AI Abdomen License. For further details on workflow and utilization, please go to the AI Abdomen presentation. Notes No. 5 SIEMENS Healthineers Touch Screen display layout SIEMENS . Healthineers ... Continuous measurement folders General Abdominal Exam Package Vascular Renal Vascular Abdomen Patient Imaging Review Abdomen Miscellaneous Spleen Length Spleen AP Spleen Width Report Prox Aorta Liver Spleen Kidney Pre-Void Bladder IVC End Exam . 00:02:32 Mid Aorta Pancreatic Duct GB Wall Thickness Cortical Thickness Post-Void Bladder Dist Aorta CBD CHD O Ellipse 20 Trace Open Trace %Stenosis-A %Stenosis-D Volume Depth Clear Screen Edit Caliper Select Cine Hide Results 6 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Labels with a small triangle () in the corner contain a folder of continuous measurements such as length, width, and AP, that, when all measured, will result in a calculated value, such as volume. To use these folders, select the label from the Touch Screen. A new window will open to display the contents of the folder. The first measurement in the sequence will be active. If the user wishes to measure a different parameter than the one that is active, simply select the alternate label key. Selecting an alternate label negates the continuous measurement feature. When configuring the Touch Screen, the user can add the entire folder (all three measurements) or a single component of the folder, such as length. Customized calculation folders (i.e., Length x Width x Height) are not available on this release. Notes No. 6 SIEMENS Healthineers Touch Screen display layout SIEMENS . Healthineers ... eneral Abdominal Renal Vascular Exam Package Vascular Abdomen Patient Right Left Imaging Review Abdomen Miscellaneous Report Prox Aorta Liver Spleen Kidney Pre-Void Bladder IVC End Exam .. 00:11:43 Mid Aorta Pancreatic Duct GB Wall Thickness Cortical Thickness Post-Void Bladder Dist Aorta CBD CHD O Distance Ellipse 2D Trace Open Trace Stenosis A %Stenosis-D Volume Clear Screen Edit Caliper Select Cine Hide Results 7 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Additional pages of labeled measurements are available by swiping the Touch Screen to the left or right and/or by using the arrow keys at the bottom right side of the Touch Screen. Additional pages are indicated to the user by white dots at the bottom of the Touch Screen above the tool bar. There are 18 measurement labels available per page with five pages available in total. Notes No. 7 SIEMENS Healthineers Generic measurements SIEMENS . Healthineers ... Tool bar General Abdominal Exam Package Vascular Renal Vascular Abdomen Patient Right Left Imaging Review Abdomen Miscellaneous Report Prox Aorta Liver Spleen Kidney Pre-Void Bladder vc End Exam . 00:11:43 Mid Aorta Pancreatic Duct GB Wall Thickness Cortical Thickness Post-Void Bladder Dist Aorta CBD CHD v O Distance Ellipse 2D Trace Open Trace %Stenosis-A %Stenosis-D Volume Depth More Clear Screen Edit Caliper Hide Results Select Cine › 8 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Generic (unlabeled) measurement options are available in the tool bar at the bottom of the Touch Screen. Unlabeled measurements will not populate on the report page, the measured value will only be located on the stored image. Options for the tool bar change with mode and are not customizable. Notes No. 8 SIEMENS Healthineers Generic measurements SIEMENS . Healthineers ... More Genera Abdominal Renal Vascular Exam Package Vascular Abdomen Patient Right Left Imaging Review Abdomen Miscellaneous Report % Prox Aorta Spleen Kidney Pre-Void Bladder IVC Distance Ratio Area Ratio Angle Vol Flow Liver Auto Calcs End Exam 00:11:43 Mid Aorta Pancreatic Duct GB Wall Thickness Cortical Thickness Post-Void Bladder More Dist Aorta CBD CHD O Ellipse 20 Trace Open Trace %Stenosis-A Stenosis-D Volume Depth More Clear Screen Edit Caliper Cine Hide Results Select 9 Unrestricted © Siemens Healthineers 2025 Speaker Notes: If the user requires a generic measurement that is not contained in the tool bar, all other generic measurement are available under the More soft key on the right side of the Touch Screen. Select More to open the generic measurement menu selection; then select the desired measurement. Note: The generic measurements will not appear on the measurement report, it will only appear on the imaging screen. Notes No. 9 SIEMENS Healthineers More options SIEMENS .... Healthineers ... Auto Calcs native tracing software • Pattern recognition software that traces and measures the circumference, two diameters, and area of a structure A6fps 95% • Select Auto Calcs under More c=1446 LD 2 • Position the first marker, press Set to anchor it and bring up the ROI • Roll the trackball to encompass the structure within the ROI • Press Update to Toggle Caliper between calipers o% Fr 42 10 Unrestricted © Siemens Healthineers 2025 Speaker Notes: One of the available More key options is for the semi-automated measurement feature, Auto Calcs software. Auto Calcs software involves pattern recognition that traces and measures the circumference, diameter, and area of a structure of interest. To perform an Auto Calcs measurement: • Select the Auto Calcs option under the More key • A caliper will appear onscreen; position and anchor the marker outside of the structure of interest • Once the caliper marker is anchored, roll the trackball to expand a rectangle • Encompass the entire structure of interest within the rectangle • Press Set and the system will use pattern recognition to trace the structure • If the trace is acceptable, press End to complete the measurement Notes No. 10 SIEMENS Healthineers More options SIEMENS .... Healthineers ... Auto Calcs native tracing software • Press Set and the border trace will appear; the user can roll the trackball and Set to edit the border HLX Breast TIS:0.04 MI:0.34 • To accept and complete the measurement, select 46fps 95% 2D Update to End Res DdB/DR70 c=1446 LD 2 ompound UA 3 MapC/T4 1 C=2.74 cm D1 D2 A=0.32 cm2 100% Fr 93 Edit Select 11 Unrestricted © Siemens Healthineers 2025 Speaker Notes: One of the available More key options is for the semi-automated measurement feature, Auto Calcs software. Auto Calcs software involves pattern recognition that traces and measures the circumference, diameter, and area of a structure of interest. To perform an Auto Calcs measurement: • Select the Auto Calcs option under the More key • A caliper will appear onscreen; position and anchor the marker outside of the structure of interest • Once the caliper marker is anchored, roll the trackball to expand a rectangle • Encompass the entire structure of interest within the rectangle • Press Set and the system will use pattern recognition to trace the structure • If the trace is acceptable, press End to complete the measurement Notes No. 11 SIEMENS Healthineers More options SIEMENS .... Healthineers ... Auto Calcs software – Edit Caliper To edit the trace: Edit Caliper • Press the Edit Caliper soft key to reactivate the Select trace, if it is already set Use the orange arrow cursor to highlight an area of C=3.26 cm • D1 the trace D2 A=0.79 cm2 • Move the cursor closer to the trace to select a smaller portion, move the cursor further away from the trace to select a larger portion • Select Set to activate the trace and edit as desired • Select Set to complete the new trace 12 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To edit the trace: • Press the Edit Caliper soft key to reactivate the trace, if it is already set • Use the cursor to highlight an area of the trace • Move the cursor closer to the trace to select a smaller portion, move the cursor further away from the trace to select a larger portion • Select Set to activate the trace and edit as desired • Select Set to complete the new trace Notes No. 12 SIEMENS Healthineers Accessing additional exam calculation packages SIEMENS. Healthineers ... Exam Package Abdomen Patient Abdomen Carotid Cardiac Breast maging Digital GYN Fetal Echo Early OB Review RIGHT SAGT Exam Package Report LEFT TRY MSK Neonatal Head OB Pediatric Abdomen Abdomen End Exam MIDLINE LEA LEV Renal Pelvis Penile Prostate TCI Testis Job Status Thyroid UEA UEV 13 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To access other exam packages, select the Exam Package key in the upper right corner of the Touch Screen. All exam packages are accessible to the user regardless of the exam preset being used. Notes No. 13 SIEMENS Healthineers Active/locked caliper trackball options SIEMENS ... Healthineers ... 1 0-6.12 cm Tegen TIC 3 61 HB/DRES C- 1540 GB /DRES 16cm Toggle Caliper Set Set Set Set Active caliper Locked caliper Cal 1 Cal 2 14 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Active calipers are teal in color, whereas locked/anchored calipers are yellow in color. The Update key is used to toggle between the caliper set when placing the caliper(s) on a structure in the imaging field. Press the Set keys on either side of the trackball to lock/anchor the caliper(s) in the desired location. When the caliper set is anchored/locked in place, the toggle feature is no longer active. The dotted line can be removed between the caliper points in System Config > Measurement & Report > Measurement > General > 2D mode. Note: The measurement will also be finalized if the Text or Body Marker tool is selected. Notes No. 14 SIEMENS Healthineers Reposition the measurement display area (MDA) SIEMENS .... Healthineers ... General TESTING TIB:0.66 TIC:3.61 TIS:0.66 MI:1.38 19fps 2D H Md LD 2 UA 3 MapD/T5 P2 15 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Should the measurement display area (MDA) default position be within the imaging field or required in a different area on the screen, the MDA can be moved. To reposition the MDA, use the trackball to place an active caliper point (“+”) within the MDA field. A teal box will appear around the MDA. Press the Set key once to “pick up” the MDA, then use the trackball to move the MDA to the desired location. Once in the desired location, select the Set key again to place the MDA. Note that there is no need to hold the Set key down continuously during the moving process. Notes No. 15 SIEMENS Healthineers Auto Trace & Sensitivity option SIEMENS . Healthineers ... 5C1 18L6 ZA HLX 1014 Carotid Workflow Above Baseline Below Baseline Above and Below Patient 2D Imaging Alto Trace Auto Trace Above Baseline Review Report Auto Trace Auto Trace Above Baseline End Exam Aute TEC On Freeze Invert Sensitivity Off Auto TEQ Live/Live OUR Menu Frequency Filter 60 Gate Size Sweep Speed 1.5 mm 60 mm/ Baseline Scale Angle Correct Steer PRF HPRF 60 60 0 60 26" -26 0 26 16 Unrestricted © Siemens Healthineers 2025 Speaker Notes: An Auto Trace feature for the Doppler trace is available to the user when the pulsed wave (PW) application is active on the ACUSON Sequoia ultrasound system. Press the Auto Trace key on the Touch Screen during an active PW sweep to activate the Auto Trace feature. There are three choices for the Auto Trace line location: • Above Baseline • Below Baseline • Above and Below [the baseline] There is a Sensitivity option for further trace optimization. Sensitivity levels range from 0-20, 20 being the most sensitive to the Doppler signal. Notes No. 16 SIEMENS Healthineers Auto trace SIEMENS .... Healthineers ... Example 10L4 10L4 Carotid Carotid TIB:1.07 TIB:1.92 TIC:0.52 TIC:1.19 TIS:0.26 TIS:0.93 MI:0.32 MI:0.31 19fps 19fps 95% 2D 2D H High H High 8dB/DR60 8dB/DR60 c=1540 c=1540 Pen Pen -1.5dB -1.5dB General General 14mm 60 PRF 2315 16mm 60º PRF 2315 40 PW 100 Mid 80 Mid 20 GS 1.5 GS 1.5 PRF 5682 PRF 5682 cm/s F 80 F 80 -20 -- 40 cmls -60 -20 -80 PS=66.74 cm/s Lt Mid CCA ED=7.79 cm/s . . . -100 1 PS=65.28 cm/s . .. RI=0.88 ED=19.49 cm/s Below the baseline Above the baseline 17 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Here are two examples of the Auto Trace feature on a sweep that is below the baseline and above the baseline. Notes No. 17 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Identify access to measurement feature and screen information • Explain editing and deleting measurements • List exam specific measurement options • Examine report access, layout and editing • Outline printing options 18 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Next, we will explain editing and deleting of onscreen measurements. Image: HOOD05162003330011 Notes No. 18 SIEMENS Healthineers Editing/updating a completed measurement SIEMENS .... Healthineers ... • Press the Edit Caliper soft key to activate caliper set 8-3.45 cm General TESTING TIB:0.66 Edit Caliper D-3.76 cm TIC:3.61 TIS.0.66 Mt1.38 Select 19fps 95% 2D H Md 0dB/DR70 c=1540 LD 2 • Use the Update key to toggle and the Set key to BDITS lock caliper Update Toggle Caliper Set Set Cal 1 Cal 2 19 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To edit a completed measurement, press the Edit Caliper soft key at the bottom of the Touch Screen. The last completed measurement reactivates indicated by turning from yellow to teal in color. The Update key above the trackball becomes the Toggle Caliper key to alternate between the two caliper points of the set. Use the trackball to move the caliper to the new location and select Set to anchor the caliper in the new position. If the user wishes to edit a different caliper set than the last one placed on the screen, continuously press the Last Caliper soft key until the desired set turns teal. Follow the steps listed above to reposition the caliper. Notes No. 19 SIEMENS Healthineers Deleting a caliper SIEMENS ... Healthineers ... With the measurement function active: • select the Delete key on the Control Panel for o General TESTING single measurement deletion D-4.28 cm TIB 0 68 TIC-3 61 TIS 0.56 113 Delete H Md 0dB/DR70 c.1540 LD2 • Select Clear Screen to delete all UA 3 MapDITS measurements Clear Screen 20 Unrestricted © Siemens Healthineers 2025 Speaker Notes: There are two options to delete calipers placed on the imaging screen. With the caliper function active: 1. Select the Delete key on the Control Panel to delete a single caliper point or a single (last) completed measurement 2. Select the Clear Screen to delete all measurements on the imaging screen. Any text on the imaging screen will also be deleted Note: When a completed labeled measurement is removed/deleted from the image screen, it will remain in the patient report. Notes No. 20 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Identify access to measurement feature and screen information • Explain editing and deleting measurements • List exam specific measurement options • Examine report access, layout and editing • Outline printing options 21 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Some exam types have measurement specific options associated with them. In this section we will take a closer look at these exams and their options. Image: HOOD05162003330011 Notes No. 21 SIEMENS Healthineers Auto OB on/off SIEMENS. Healthineers ... Auto OB key is orange when ON Auto OB key is gray when OFF Fetal Maternal am Package Fetal Maternal Package OB Patient Fetus A Add Fetus Auto OB Patient Fetus A Fetus B Fetus C Fetus D Auto OB Imaging Imaging Review Auto BPD Auto HL Cerebellum Nuchal Thickness Binoc D LVOT & Review BPD Cerebellum Nuchal Thickness Binoc D LVOTs Report End Exam Auto HC Auto OFD Cist Magna Nasal Bone IOD RVOT $ End Exam HC OFD Cist Magna Nasal Bone IOD RVOT $ Auto AC CSP LV -A Facial Angle AC CSP LV - A Facial Angle Auto FL Lat Vent LV - P AFI FL Lat Vent LV - P AFI O 20 Trace Open Trace «Stenosi A Volume 20 Trace Volume Dear Screen Edit Caliper Hide Results Clear Screen Edit Caliper Cine Hide Results 22 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The automated Auto OB feature is an advanced option available on the ACUSON Sequoia ultrasound system. Select Auto OB on the Touch Screen to turn the feature on or off. When the Auto OB key is highlighted in orange, the feature is active. The measurement labels on the Touch Screen reflect the Auto OB active status by displaying Auto on each label that is available with the feature. The available labels are: • Bi-parietal diameter (BPD) • Head circumference (HC) • Abdominal circumference (AC) • Femur length (FL) • Crown rump length (CRL) • Humerus length (HL) • Occipital frontal diameter (OFD) When the Auto OB key is grey, the feature is inactive/off. Note that the regional measurement type for bi-parietal diameter (European – BPD outer to outer or US – BPD outer to inner) is configured in System Config > Measurement & Report > Measurement > Exam Specific > OB Exam. Notes No. 22 SIEMENS Healthineers Fetal heart rate measurement SIEMENS . Healthineers ... With the M-mode sweep completed: Default • Activate the caliper function Patient Fetus A Fetus B Fetus Add Fetus • Default on Touch Screen is to Fetus A - manually select Imaging alternate fetus if multiple Review Fetal HR • Select Fetal HR on Touch Screen and measure the appropriate Report beat(s) Fetal HR End Exam Dibpm • Number of beats for measurement is displayed in lower left corner of image screen • Number of beats can be set in system configuration M-Distance Time M-Heart Rate Clear Screen Last Caliper 23 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To measure a fetal heart rate, activate the caliper function after obtaining and freezing an appropriate M-mode sweep. The default fetus will be to Fetus A. If there are multiple fetuses to measure, manually select the correct fetus from the Touch Screen options. Note that if you have not selected more than one fetus at the start of the exam, there is an option to Add Fetus located on the Touch Screen. Select the Fetal HR option from the Touch Screen and the systems will activate the measurement tool associated with the label. Measure the appropriate beat or beats on the image screen using the trackball and Set key to place the caliper markers. The number of beats that are required for the measurement are indicated in the bottom left corner of the Touch Screen when the measurement is active/selected. The number of beats used in a measurement can be configured in System Config > Measurement & Report > Measurement > General [Heart Rate tool]. Notes No. 23 SIEMENS Healthineers Hip measurements SIEMENS . Healthineers ... Available labels: Default Exam Package Ped Hip • Hip Angle Femoral head coverage (stressed Patient • Right Left Shadow and flexed) Imaging Onscreen tool and method* options: Review lip Angle (a) Stressed %FHC Flexed %FHC • Alpha and Beta Report • Alpha only End Exam O Distance Ellipse 20 Trace Open Trace *Stenosis A %Stenosis-D Volume Depth More Clear Screen Edit Caliper Select Hide Results *Options only for Hip Angle. MDA will only display the configured tool(s) 24 Unrestricted © Siemens Healthineers 2025 Speaker Notes: A specialized hip measurement package is available on the ACUSON Sequoia ultrasound system. System Configuration > Measurement and Report > Measurement > Per Label Configuration > Ped Hip The available measurement labels are: • Hip angle • Percent femoral head coverage (stressed and flexed options) The user has the option to measure both alpha and beta or the alpha angle only on the image. Configure the tool and method under the Per Label Configuration in the system configuration. This screen shot is configured to measure Alpha only. Note that the configuration options are only for the hip angle label. When in Live Dual, the shadow functions allows the user to measure on the left image; the measurement also appears in the same place on the right image. Note: Rotate image is available with the Hip measurement package. Notes No. 24 SIEMENS Healthineers For more information on measurement configurations, please refer to the ACUSON Sequoia VB30 Ultrasound System Measurement Configuration educational PowerPoint presentation. Notes No. 24 SIEMENS Healthineers Transcranial Imaging (TCI) SIEMENS . Healthineers ... • Factory measurement labels Default Exam Package TCI displayed in Doppler mode Patient Right Left Auto Trace Above Baseline • Display is configurable in the Imaging Touch Screen Layout Editor Review Prox MCA M1 Terminal ICA ACA AT PCA P1 Prox Basilar A Terminal Vert A Report Auto Trace available Mid MCA M1 ICA Siphon ACOA PCA P2 Mid Basilar A • End Exam Dist MCA M1 Dist ICA-skull entrance Prox Ophthalmic A PCOA Dist Basilar A RI H RE-SID inart Cycle Vol Flow D Trace Velocity Time Heart Rate More Clear Screen Edit Caliper Angle Correct (Select Cine 60 0 60 Hide Results 25 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The Transcranial Imaging (TCI) preset contains factory labels within the Doppler mode. The Touch Screen display is configurable in the system configuration under the Touch Screen Layout Editor. For more information on measurement configuration, please refer to the ACUSON Sequoia Ultrasound System 3.0 Measurement Configuration educational PowerPoint presentation. Notes No. 25 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Identify access to measurement feature and screen information • Explain editing and deleting measurements • List exam specific measurement options • Examine report access, layout and editing • Outline printing options 26 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Next, we will examine how to access the patient report and report layout. Notes No. 26 SIEMENS Healthineers Report access SIEMENS . Healthineers ... General Abdominal Exam Package Vascular Renal Vascular Abdomen Patient Report access from Imaging the Touch Screen Review Hepatoportal/TIPS Aorta-Iliac Liver Transplant Mesenteric Report Liver Stent-Portal End Spleen End Exam Portal V Stent-Mic Splenic CHA Stent-Hepatic End IVC O Distance Ellipse 2D Trace Open Trace %Stenosis-A %Stenosis-D Volume Depth More Clear Screen Last Caliper Cine Fr 6 Hide Results 27 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To access the report, select Report on the left side of the Touch Screen. The user does not need to have the measurement feature active, as the report option is always displayed on the Touch Screen, no matter which mode the user is currently in. To exit the report, select another option such as Imaging to return to the imaging screen or Patient to return to the patient demographic page. Notes No. 27 SIEMENS Healthineers Report layout SIEMENS . Healthineers ... Section SIEMENS Healthineers Patient Report Navigation heading Patient History Abd Organs TEST, PATIENT Study Date 8/16/2024 pane Abdominal Assessment Images Patient 10 23434 Height Accession # Date of Birth Summary Comments Weight Other BP BSA - History Scroll bar Study ... Comments Institution Sequela 3. Performing Physician Operator Referring Physician Thumbnails Expand or Liver collapse all Value Method Liver Length 13.57 cm LAST 13.57 fields Liver AP 7.70 on Last 7.70 Liver Width 8,55 cm 8.55 Summary Measured Collapse All Available Export to PDF results listed functions Store Report Transfer Report by exam Edited Value " 28 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The general layout of the report contains: • A navigation pane to quickly move the user to any part of the report • Results divided into anatomy-based sections with the measured results listed below • An option to expand or collapse all fields/sections • A scroll bar that allows the user to manually move around the report from top to bottom/section to section • Image thumbnails • Available functions such as Export to PDF or store report Notes No. 28 SIEMENS Healthineers Navigation pane SIEMENS . Healthineers ... Patient History • The navigation pane contains links to different Patient History report sections Maternal Assessment Abd Organs • Sections are organized by anatomy Fetus Rena • An open/active section heading is highlighted Fetal Biometry in orange Biophysical Profile Aorta All reports/sections that have data are listed Fetal Assessment Abdominal Assessment • Any sections that have been “hidden” in Fetus Images Carotid • system configuration will not be listed, even if Fetal Growth Charts Cardiac measurement data has been obtained Images Images Summary Comments Summary Comments 29 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The navigation pane allows the user to easily jump between different sections of the report. Sections are organized by anatomy and open or active section headings will be highlighted in orange. All areas of the report that contain measured data will be listed; if any sections have been “hidden” in the system configuration, the section will not be listed/displayed, even if a measurement was taken. If the user wishes to have the hidden measurement data displayed, they will have to go to System Config > Measurement & Report > Report and check off the section they wish to display. Notes No. 29 SIEMENS Healthineers Report content structure SIEMENS . Healthineers ... • Sections can be individually collapsed by selecting the Liver “+” or “ - ” for that section A maximum of five labeled measurements will be CBD 0.49 Om Last • displayed - Spleen Valde Method Spleen Length $1.24 Last 11.24 • The display method options are determined by tool Spleen AP 7.10 Last type and can be manually altered for all exams Spleen Width 13.97 Last Spleen Vol 583.74 Method - Kidneys Last Value Method Last Rat Kodney Length 18:13 Last Avg Lt Kidney Length 20.31 Last 20.31 Min Max - Kidneys Side by Side Right Left Kidney Length 18.13 cm 20.31 cm • “Side-by-side” options are available for some labels Collapse All with left/right options 30 Unrestricted © Siemens Healthineers 2025 Speaker Notes: • The report sections can be individually collapsed by selecting the plus (+) or minus (-) sign by the section heading • A maximum of five labeled measurements will be displayed at one time • If more than five measurements are taken, only the last five will be displayed • The display method will differ between labels as some options are not available for all labels only Last and Avg are available for all labels – • To choose a different display method, use the Pointer to open the drop-down menu of choices and select the alternate display type • For some labels with laterality, such as kidney, a “side-by-side” section is available that displays each result with the contralateral result in side-by-side columns Notes No. 30 SIEMENS Healthineers Report Summary - Flexible SIEMENS . Healthineers ... General Measurements included: Carotid Right • Diameter Diam V PS V ED V MD TAMX V • Peak Systole (PS) Prox CCA 2.16 cm/s 24.03 cm/s 0.00 cm/s 0.00 cm/s • End Diastole (ED) Diam Resistive Index (RI) Carotid Asse • PS • Systolic/Diastolic (S/D) Images ED • Time Average Max (TAMx) MD • Time Average Min (TAMn) TAMX • MD Pulsatility Index (PI) TAMn • • Angle RI S/D Angle 31 Unrestricted © Siemens Healthineers 2025 Speaker Notes: This slide shows the measurements included in the customizable drop-down list for generic and TCD measurements. To display the drop-down list, users select Report and then Summary. The measurements included in this option are: • Diameter • Peak Systole (PS) • End Diastole (ED) • Mean Diastole (MD) • Time Average Max (TAMx) • Time Average Min (TAMn) • Resistive Index (RI) • Systolic/Diastolic (S/D) • Angle Users can select and customize what is displayed in the Report Summary under the Per Label Configuration tab. Notes No. 31 SIEMENS Healthineers Report Summary - Flexible SIEMENS . Healthineers ... TCI Measurements Included: - Transcranial • Peak Systole (PS) Right PS V ED V RI V SV Depth Mean TCD • End Diastole (ED) Resistive Index (RI) Prox MCA M1 0.00 cm/s • PS 1.00 80 mm 5.59 cm/s • SV Depth Images ED • Mean TCD RI Time Average Max (TAMx) Summary Cor • SV Depth • Time Average Min (TAMn) Mean TCD • Mean Diastole (MD) TAMX • Pulsatility Index (PI) TAMn • Angle MD PI Angle 32 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The transcranial Doppler measurements included are: • Peak Systole (PS) • End Diastole (ED) • Resistive Index (RI) • SV Depth • Mean TCD • Systolic/Diastolic (S/D) • Time Average Max (TAMx) • Time Average Min (TAMn) • Mean Diastole (MD) • Pulsatility Index (PI) • Angle Users can select and customize what is displayed in the Report Summary under the Per Label Configuration tab. Notes No. 32 SIEMENS Healthineers Report Summary - Flexible SIEMENS . Healthineers ... Carotid • Allows user to customize summary measurement display Right PS ED MD TAMX PI V • Provides drop-down options when six or Prox CCA 81.02 cm/s 15.43 cm/s 14.15 cm 1.76 more included measurements are utilized Carotid Assessment PS ED Rt CCA MD Lt CCA Rt CCA Plaque Description TAMX Lt CCA P Rt CCA Diameter Reduction P Lt CCA Reducti Rt CCA Comments RI Lt CCA SID Rt BIF Angle Lt BIF Rt BIF Plaque Description Lt BIF P 33 Unrestricted © Siemens Healthineers 2025 Speaker Notes: • The summary gives the user more flexibility by allowing filtering of the information that they would like to display in each column in the measurement display • A drop-down menu is available when six or more measurements are utilized in a measurement. In this example, eight measurements appear in the drop-down menu Notes No. 33 SIEMENS Healthineers Report Summary - Flexible SIEMENS . Healthineers ... • Users can hide a column by selecting the blank option in Carotid the drop-down menu Right PS ED MD TOX CCA 81.02 cm/ 15.43 cmh 14.15 .76 Carotid Assessment ED RI CCA MD Lt CC Rt CCA Plaque Description TAMX Lt CC RI CCA Diameter Lt CC Reduction Rt CCA Comments Lt CC SID Rt BIF Angle Lt BI Rt BIF Plaque Description LE BIF Carotid Right Left Diam V PS V ED V TAMX V Diam PS ED V TAMX V V Prox ICA 0.51 cm 62.95 cm/s 9.60 cm/s 25.61 cm/ 0.42 cm 52.64 cm/s 6.05 cm/s 19.31 cm/s 34 Unrestricted © Siemens Healthineers 2025 Speaker Notes: • Users can hide a column in the measurement summary by selecting the “blank” option in the drop-down menu • The example here shows how the TAMn was hidden by selecting the blank option from the drop-down Notes No. 34 SIEMENS Healthineers Function keys SIEMENS . Healthineers ... Function keys relating to the report are displayed on the Touch screen display options Touch Screen and imaging screen Store Report Transfer Report OB History • Store Report • Print Report Transfer Report Print Report Export To PDF Edit Report • • Export to PDF • OB History Imaging screen display options • Edit Report Summary • Summary Export to PDF Store Report Transfer Report Print Report 35 Unrestricted © Siemens Healthineers 2025 Speaker Notes: The report function keys are displayed on both the Touch Screen and the imaging screen. These keys are: • Store Report • Print Report • Transfer Report • Export to PDF • OB History • Edit Report • Summary These function keys allow the user to: • Store the report automatically as images to the patient exam • Print the report to an offline device if configured (USB or Printer server) • Transfer the structured report while still in progress (exam has not been ended) • Export the report in PDF format to an offline storage device such as a USB • Add OB history to an in progress (registered) patient • Edit the report information • Show the report summary Notes No. 35 SIEMENS Healthineers OB History SIEMENS . Healthineers ... • Obstetric history can be manually added to the OB History report to compare growth parameters Fetus A Use the Pointer to select the date the previous exam Trend Exam Date GSD CRL BPD HC AC FL EFW Interval • Growth was performed on • Enter data in the fields provided and select OK to add Note: if the previous exam was performed on the same system, the data will be populated in the OB History warm Cancel 36 Unrestricted © Siemens Healthineers 2025 Speaker Notes: An obstetric history section is available in the report. If the user has access to previous ultrasound exam data for their patient the data can be manually entered in the OB History section. To input the data, the user will need to enter the date the exam was performed and then all subsequent values associated with the previous exam. Select OK when all necessary fields are populated to save the data. These values will be compared to the new exam data in the Fetal Growth Charts section. If the previous exam was performed on the same system and is still on the hard drive of the system, the data will be automatically populated into the OB history section. Note that the system does not check growth data manually entered in the patient history for accuracy or internal consistency. Notes No. 36 SIEMENS Healthineers Fetal growth charts SIEMENS . Healthineers ... Fetal growth charts can be displayed in the report - Fetal Growth Charts • 2x2 • User can change the measured parameter and chart Hadlock Hadlock author using the drop-down menus located on each chart 5 PetUS A Fetus A cm • Options for chart layout are found in the drop-down 15 Age(weeks ) 35 40 15 20ge(we 22s) 30 35 40 menu in the right upper corner – this is a 2 x 2 layout Hadlock Hadlock V • To collapse/hide charts click on the minus sign (-) in 5 25 SON the section heading Fetus A Apetweets) 40 Age (weeks ) 30 Collapse All 37 Unrestricted © Siemens Healthineers 2025 Speaker Notes: • Fetal growth charts for applicable growth parameters can be displayed in the report • The user can change the displayed parameter as well as chart author by using the drop- down menu located in the title of each chart • Options for chart layout are found in the upper right corner – this is a 2 x 2 layout • To collapse or hide the chart from display, click on the minus (-) sign next to the section heading • Note that the chart will not print as part of the patient report if the section is hidden or collapsed even if it is defaulted to show in the system configuration. Notes No. 37 SIEMENS Healthineers Cardiac report SIEMENS . Healthineers ... • Cardiac reports are displayed in sections that contain - LV Value Method headings and sub-headings to divide the results Dimensions PLAX IVS d PLAX 0.93 cm Last 0.89 1093 Display method options can be changed for IV5 s PLAX 1.44 cm Last 1.09 1.44 • LVID d PLAX 5.54 cm Last 5.63 5.54 individual measurements from those listed in the LVID & PLAX 3.78 cm Last 3.72 3.78 LVPW d PLAX 0.91 cm Last 0.85 drop-down menu 0.91 LVPW 3 PLAX 1,53 cm Last 1.50 1.53 IV/S/LVPW 1.03 • If changes are made, an additional function key to IVS 'Thick 54. LVPW ISTNick 69.4 Save as Cardiac Default will store the current settings LV Relative Wall Thickness 32.7 CLV RWTX A4C LV Major's A4C 5.96 cm Last 5.96 LV Mass ASE IV5 d PLAX 0.93 cm 0.89 0.93 LVID d PLAX 5.54 cm Last 5.63 5.54 LVPW d PLAX 0.91 cm 0.85 0.91 LV Mass ASE 192.55 Collapse All Set all results for Cardiac to Default Save as Cardiac Default 38 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Cardiac results are displayed in sections that are further separated into headings and sub- headings. This division allows the user to easily view the measurement results by parameter and view. As with other exams, the cardiac report has the option to change the display method for individual results by accessing the drop-down menu of a given measurement. Unlike other exams, however, there is an option at the bottom of the report page that allows the user to save the altered display method(s) as the new default setting for the cardiac exam. Going forward, all cardiac exams will be displayed in the newly saved method. Notes No. 38 SIEMENS Healthineers Available assessments SIEMENS . Healthineers ... Assessment sections are available for: - Fetal Assessment • Abdomen placenta Placenta Location Anterior Posterior Gyn 1. Fundal Mid • Right Lateral Left Lateral . Low lying Partial Previa • Early OB – fetal and maternal Marginal Previa Complete Previa Placenta Grade • OB – fetal and maternal Placonta Cord Insertion Placenta Comments • Fetal Echo Amelodic Fhald • Carotid J Vessel Coed • Hip - Abdominal Assessment Comment or drop-down menu formats are available. Liver Echosestuse Fatty titration Custom assessments can be added in the System Portal Hypertension Portal Vein Configuration. Focal Lesions - GYN Assessment Uterus Uterus Comments Endometrium Comments 39 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Preloaded assessment packages are available for: • Abdomen • Gyn • Early OB – fetal and maternal • OB – fetal and maternal • Fetal Echo • Carotid • Hip Assessments can be in a drop-down format with pre-determined content or freeform comments. Use the keyboard to enter freeform comments in the field provided. Custom assessments can be added – the steps to add custom assessment are covered in the Measurement Configuration presentation. Notes No. 39 SIEMENS Healthineers Summary comments SIEMENS . Healthineers ... • A section for summary comments is available for - Summary Comments each exam type EXAM WITHIN NORMAL LIMITS GB REMOVED • Comments can be freeform and added by using the keyboard to enter the specific comment • If pre-programmed comments are available, select the Load Comments key • Custom comments can be added in system configuration Load Comments Collapse All 40 Unrestricted © Siemens Healthineers 2025 Speaker Notes: A section for adding summary comments to a patient report is available to the user. Comments can be added manually using the keyboard or selected from a pre-defined list that has been created in the measurement configuration. To view the list of pre-defined comments, select the Load Comments key at the bottom of the section. The steps to add custom summary comments is covered in a separate presentation dedicated to Measurement Configurations. Notes No. 40 SIEMENS Healthineers Summary comments SIEMENS . Healthineers ... Add pre-programmed comments To add comments: - Comments Lists Select Load Comments Load Comments General • Exam within normal limits. Recall exam x2 weeks. Gallbladder removed. Technically difficult exam. • Use the Pointer to highlight the chosen comment • Select OK • Comment will populate report Multiple comments can be added to a single report one comment at a time. OK Cancel 41 Unrestricted © Siemens Healthineers 2025 Speaker Notes: To add pre-programmed comments to a report: • Select Load Comments at the bottom of the screen • Comments list will be displayed on the screen • Use the Pointer to highlight the comment you wish to add • Select OK to add the comment Note that you can add multiple pre-programmed comments to a report, however, they must be added one at a time. Notes No. 41 SIEMENS Healthineers Add images to report SIEMENS . Healthineers ... Quick Patient Report Healthineers Drop-down for Patient History navigation to Cantid display layout Images images section Summary Comments WWW Enun PCA EmRICCA - 2 Summary Collapse AN Export to PDF Store Report Edited Value + 42 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Images can be added to the patient report from the thumbnail panel. To add an image to the report: • Move the Pointer over the image you wish to add • Use the Set key to add the image from the thumbnails to the report (single “click”) The user has the option to choose the display format of any added images by selecting the desired format from the drop-down options. The minimum layout display is 1 x 1, and the maximum layout display is 5 x 4. The example shown here is a 2 x 2 display. To remove an image from the report: • Select the desired image in the report display • Select Delete There is no maximum for adding images to the exam, however, the more images are added to the exam, the larger the patient report becomes. Notes No. 42 SIEMENS Healthineers Edit report SIEMENS . Healthineers ... • Report data can be edited Touch Screen display • Function key to activate editing feature is available on Store Report Transfer Report OB History both the Touch Screen and the imaging screen • Select Edit Report and use the Set key, trackball, and keyboard to input the new values Print Report Export To PDF Edit Report Imaging screen display Edit Report Export to PDF OB History Store Report Transfer Report (continued next slide) Print Report 43 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Report data values can be manually edited by using the Edit Report function. The Edit Report key is displayed on both the Touch Screen and the imaging screen when the report is displayed. To edit a value, select either Set key to enable editing, then use the Set key, trackball, and keyboard to input the new values into the report (the step-by-step instructions are covered in the next slide). Notes No. 43 SIEMENS Healthineers Edit report SIEMENS . Healthineers ... Once the Edit Report function is selected: Study ... • Use the Pointer and Set key to select/highlight the Comments value to be edited Institution Institution Performing Physician • Use the keyboard to enter the new value or use the Operator Referring Physician Carotid Delete key on the Touch Screen to remove value Value Method entirely Rt Prox CCA 71.73 an/ Last 70.92 • Move to another cell with the Tab key or trackball to ED 12.09 am 10.88 10.88 12.09 complete change/deletion Angle -60 . -60 -60 -60 - Carotid Assessment • Edited values will be indicated by an asterisk (*) in the Rt CCA LI CCA data cell and noted at the bottom of the report Rt CCA Plaque Description Lt CCA Plaque Description Rt CCA Diameter Lt CCA Diameter Reduction Reduction Rt CCA Comments Lt CCA Comments Collapse All 44 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Once the Edit Report function is selected: • Use the Pointer and Set key to select and highlight the value to be edited • Start typing on the keyboard to replace the value or use the Touch Screen Delete key to remove the entry entirely • Move to another cell using the Tab key on the keyboard or the trackball to complete the change or deletion Any value that has been edited will be indicated by an asterisk (*) in the data cell. Notes No. 44 SIEMENS Healthineers Editing OB dating data SIEMENS . Healthineers ... • OB dating data can be edited on the report Patient OB TEST Study Date 2/21/2024 • Use the Pointer to select the calendar drop-down Patient ID 24.02.21-18:58:09-STD-1.3.12.2.1107.5.5.17.0 Height Accession # Date of Birth Weight and desired date Sex BSA 5/23/2022 Female Gravida - History May 2022 Study LMP MIDIYYYY Gravida Para SMTWTFS Comments EDD MADIYYYY Aborta Ectopics 24 25 26 27 28 29 30 Clinical Ane W Num of Fetuses 1 1 2 3 4 5 7 - Institution 8 9 10 11 12 13 14 Institution Performing Prysician 15 16 17 18 19 20 21 Operator Referring Physician 22 23 24 25 26 27 28 - Images 29 30 31 1 2 3 4 2x2 • The date can be altered manually by highlighting the field entering the date using the keyboard Collapse A 45 Unrestricted © Siemens Healthineers 2025 Speaker Notes: • OB dating data can be added or altered on the report page • Use the Pointer to select the calendar icon next to the field you wish to alter or highlight the field and manually enter the new date data Notes No. 45 SIEMENS Healthineers Edit OB dating data behavior SIEMENS . Healthineers ... Data type available/entered Report behavior Patient registration 1. Last Menstrual Period (LMP) • LMP is displayed and is editable • If LMP is edited from the report page, • EDD and Clinical Age are calculated from LMP all values (LMP, EDD, and Clinical Age) • LMP does not change if Clinical Age is changed are updated on the patient registration page 2. Expected Date of Delivery (EDD) • EDD is displayed and is editable • If EDD is edited from the report page, • EDD will be re-calculated on report if Clinical Clinical Age is re-calculated and both Age is edited values are updated in the patient • LMP will be blank (not calculated from EDD if registration page a value was not entered originally) • LMP remains blank if not entered 2. Clinical Age • Clinical Age is displayed and is editable • If Clinical Age is edited from the report • If Clinical Age is edited, EDD will be re- page, EDD is re-calculated and both calculated on the report values are updated in the patient • LMP will be blank (not calculated from Clinical registration page Age if a value was not entered originally) • LMP remains blank if not entered 46 Unrestricted © Siemens Healthineers 2025 Speaker Notes: If the user alters or adds OB dating data to the report page, there are specific behaviors to be aware of with regards to what will and will not be (re)-calculated/displayed. If the Last Menstrual Period (LMP) is added or edited, all other dating values – LMP, Expected Data of Delivery (EDD), and Clinical Age – will be updated on the patient registration page as well as displayed on the report. If only the EDD is entered and/or altered, the Clinical Age will also be edited and updated on the patient registration page. The LMP value will not be re-calculated if the EDD is altered. If there was no LMP entered on the patient registration page at the beginning of or during the exam, the field will remain blank. LMP will not be calculated based on EDD. If only the Clinical Age is entered and/or altered, the EDD will be re-calculated; however, the LMP will remain unchanged or blank, depending on if the information was already populated. Notes No. 46 SIEMENS Healthineers Edit shear wave values SIEMENS . Healthineers ... • Shear wave values cannot be edited in the Liver Site 1 Vs report, only deleted E Depth m/s kPa Select Edit Report to activate the editing 1.30 5.0 4.7 • 1.26 4.8 4.7 function 1.52 6.9 4.7 5.6 4.7 1.28 Values cannot be retrieved once they are 1.37 4.9 4.7 5.7 4.7 • 1.34 5.3 4.7 deleted 1.37 5.6 4.7 1.24 4.6 4.7 1.81 9.9 4.7 1000 VOUIWN - • All values – Mean, Std Dev, Median, IQR, and IQR/Median listed in the results will be re- Mean 1.39 0.17 P.8 Std Dev 1.6 calculated Median 1.35 5.4 IQR 0.09 0.8 IQR/Median 0.07 0.1 Overall Statistics Mean 1.39 m/s Std Dev 0.17 m/s Median 1.35 m/s IQR 0.09 m/s IQR/Median 0.07 Mean 5.8 kPa Std Dev 1.6 kPa Median 5.4 kPa IQR 0.8 kPa IQR/Median 0.1 Note: Shear Wave Speed and Elasticity values may vary among manufacturers! 47 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Shear Wave values cannot be edited in the report; values can only be deleted. Select the Edit Report key on the Touch Screen or report (imaging) screen to activate the edit function. Once the Shear Wave value has been deleted, it cannot be retrieved. Any associated values – Mean, IQR, etc., will be re-calculated. If the report has already been stored it will need to be stored again with the new values. Notes No. 47 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Identify access to measurement feature and screen information • Explain editing and deleting measurements • List exam specific measurement options • Examine report access, layout and editing • Outline printing options 48 Unrestricted © Siemens Healthineers 2025 Speaker Notes: Next, we will examine how to access the patient report and report layout. Notes No. 48 SIEMENS Healthineers Print/store report SIEMENS . Healthineers ... SIEMENS Healthineers Patient Report Patient History Touch Screen Report Maternal Assessment - Fetus store report Patient Fetal Hintnetry Store Report Biophysical Profile option Transfer Report OB History Fetal Assessment Imaging Fetus Images Fetal Growth Charts Review Pilot Report Export To PDF Summary Images Summary Comments Report End Exam Tab W T U O Imaging screen aps Loc S D G H Enter Summary store report Shift Z Delete Export to PDF Del History option Store Report Ctrl Alt 49 Unrestricted © Siemens Healthineers 2025 Speaker Notes: There are options to transfer and print the report on both the Touch Screen and the imaging screen when the report is selected. To store the entire report as images in the patient file, select Store Report on the Touch Screen or on the imaging screen using the Pointer. All report pages with data will be stored as a single report. Sections that were hidden or de-selected in the system configuration will not be stored with the report even if there were measurements taken for that section. To add these sections back into the report, – the user must go back into system configuration and check off (turn on) the sections. Steps to turn off or on report sections are covered in a separate measurement configuration presentation. The report can also be stored as individual screenshots using the Print/Store key on the Control Panel. The report can also be sent (“printed”) to a USB in PDF format. If structured reporting is utilized/configured, the SR report data can be sent to an external location during an exam or at the end [close] of an exam. To send the SR report without closing the exam, select the Transfer Report key on the Touch Screen or the imaging screen. A Print Report option is also available on the Touch Screen and imaging screen if there is an external printer configured to the ultrasound system. The key will only be available/active if the printer is configured. Notes No. 49 SIEMENS Healthineers Store Report command SIEMENS. Healthineers ... Patient Last Name First Name Carotid Patient ID Date of Birth Spleen Height Rt Prox CCA Diam 6.24 BP 12.91¢ Rt Prox CCA ED History PS 83.9 Cm RI Fetus Information Kidneys ED 35.7 cr SID RI 0.57 Angle Prox CCA Clinical Age / GA Fetal Ratios Study 2.35 Comments Valu Lt Prox ECA Angle Prox ECA PS Label Ratio Range Low Range High Growth Author Rt Kidney Length 10.80€ 60.1 ₫ Prox ICA HCIAC 0.97 nstitution Lt Kidney Length 11.25 € Rt Prox ECA ED 13.2 cr PS 58.1 € RO. 15 ED 9.9 cm Carotid Ratios EFWS FUBPD Fetal HR FUHC 19.86 SID FUAC 19.28 Institution Kidneys Side-by-Sid RI Angle Performing Physician SID 5.87 EB'D 67.52 Lt Prax ICA Fetal Biometry Referring Physician Thyroid Operator Kidney Length Angle PS T Prox ICA ED 83.9 Cr RI Value Method Liver Thyroid 15.2 cr SID BPD Lt Thyroid Length 4.08 cm Last Lt Thyroid AP 12.46 cm Last Lt Thyroid Width 2.46 cm Last Rt Thyroid Length 0.87 Angle Carotid Side-by-Side Lt Thyroid Vol 59,90 cm) Lt Prox CCA PS Thyroid Side-by-Side Right Left Thyroid Length 4.08 cm EFW Thyroid AP 12.46 cm Thyroid Width 2.46 cm Thyroid Vol 59.90 cm3 Edited Value " 50 Unrestricted © Siemens Healthineers 2025 Speaker Notes: If the Store Report key is used to save the report after multiple exams have been performed on the same patient, the report will be saved over several pages as one single report. If the user requires a separate report for each exam type, the report must be saved, and the exam ended for each exam type before moving on to the next exam. Closing/ending each exam after the report has been saved is the only way individual reports can be generated. Notes No. 50 SIEMENS Healthineers Trademarks and disclaimers SIEMENS. Healthineers ... ACUSON Sequoia is a trademarks of Siemens Medical Solutions USA, Inc. 51 Unrestricted © Siemens Healthineers 2025 Speaker Notes: No speaker notes. Image: HOOD05162003330011 Notes No. 51 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS. Healthineers ... Questions? 52 Unrestricted © Siemens Healthineers 2025 Speaker Notes: No speaker notes. Notes No. 52
- Onscreen Measurement and Report