This document will help the user understand the Freehand 3D GYN feature using the ACUSON Sequoia™ ultrasound system.

Quick Card Freehand 3D for Gynecology ACUSON Sequoia Ultrasound System 3.5 (VB30) siemens-healthineers.com/sequoia 111 SIEMENS Healthineers ACUSON Sequoia CO SIEMENS Healthineers . Getting Started The 3D volume data set is a series of 2D images gathered manually over a timed acquisition. Measurements can not be performed on the MPR's. • The 5C1, 9C2, 9EC4, 10EV3, 10L4, 11M2, 11M3, 15L4, 18H6, 18L6, and HLX transducers are available to perform acquisitions of Freehand 3D volume data sets Step 1 3D • Select the appropriate curved transducer for scanning • Press 3D/4D control • The set up Touch Screen corresponding to the transducer selected will be displayed, showing the first scan direction and Rocked, highlighted in orange Rocked Linear Step 2 VOI • If desired, place the Volume of Interest (VOI) to include the anatomy desired. The VOI can be curved by selecting the Curve option on the Trackball Set key • The VOI box may be deactivated by selecting the VOI key on the Touch Screen. When disabled, the entire field of view will be acquired in the volume. The VOI can also be selected after the acquisition is complete. 3D Start • Adjust Touch Screen parameters • Find the midline uterus • Angle the probe towards the right adnexa (notch up) or inferior Position Size Curve to the cervix (notch towards to patient's right) • Press Update above the Trackball or Start and perform a single Update sweep in the short axis with a paint brush motion • Sweep right to left or inferior to superior • Follow the timing of the progress bar 2 siemens-healthineers.com/ultrasound Step 3 3D Clip • Press Image to store the volume ºO Image Render Modes There are four render modes available that can be selected on the Touch Screen before (page 1) or after acquisition (page 2): • Surface: Smooths the image contours, creating a soft sculptured Surface Vascular Skeletal appearance for highlighting surface features of soft tissue • Vascular (Minimum Intensity Projection/Min IP): Best for visualizing hypo-echoic lesions and vascular structures LightSource • Skeletal (Maximum Intensity Projection/Max IP): Best for intrauterine devices and bony structures Light Source: Helps increase depth perception, reveals surface Light • details, provides an element of texture, and can provide a deeper understanding of relational anatomy. The adjustable light source direction is automatically activated in a 1:1 layout, but may be activated/deactivated in any layout by selecting the Light key on page 1 of the Touch Screen Use the Trackball to adjust the direction of the light. siemens-healthineers.com/ultrasound 3 FlexPlane The FlexPlane tool allows the user to obtain and visualize anatomy of any shape along any plane. This is especially useful FlexPlane when imaging complex or irregularly shaped structures. The user can choose from: • Line – A straight line in any direction Line • Trace – A freehand line traced in any direction • Spline – An open spline controlled by selecting the Set key Trace Spline along the path of the spline Once the desired option is chosen: Press either Set control to begin the line Start Start • Draw • Press either Set key again to end the Line/Trace tools or to change the direction of the Spline tool (double-click either Redraw Set control to end the Spline) Set Set Draw • To redraw the slice, press the Update control Redraw Position Use the rotary Soft Keys to adjust the volume thickness as well as Thickness line or slice orientation. Rotate Line Rotate Slice 2 mm MPR & VR Orientation A B Adjust the Multiplanar Renderings (MPR) and the volume using the rotation tools on the Control Panel. Select the desired quadrant from the Touch Screen C VR • • The MPR slicing function is manipulated using the 3D/4D control • The X axis is manipulated using the M-mode control • The Y axis is manipulated using the PW Doppler control • The Z axis is manipulated using the Color Doppler control ... Use the rotation tools on the Touch Screen to quickly rotate the volume rendering by set degrees. 90º 180º 270º 4 siemens-healthineers.com/ultrasound Multislice Multislice The Multislice tab contains options for viewing multiple slices of the selected MPR plane at the same time. It is often referred to as a CT or MRI view. • Select the desired plane using the A, B, and C keys A B C VR • Select the desired layout from the Touch Screen Use the rotary soft keys to adjust the number of slices, distance between slices, and the position of the slices Slices Distance Position of Slices 5 2 mm 0 mm Editing Editing The editing tab contains options for removing unnecessary structures. Closed Select the desired tool from the Touch Screen Line Open Spline Spline • • Using the Trackball and Set keys to delineate the area for removal Place the scissor icon in the area to be removed and press the Undo All • Set key to finalize • Edits may be reversed using the Touch Screen options Redo Last Undo Last siemens-healthineers.com/ultrasound 5 Animation • The volume can be animated to rotate up to 360 degrees • Located under the Editing tab Speed • Curved arrows will continuously rotate the volume up to 360 degrees after using the Trackball to select the First image to start Medium with and the Last image to end with • Double-straight arrows will animate the volume to rotate from the First selected image to the Last selected image in one direction; then go back in the opposite direction from the Last to the First and repeat • Select the play icon to start animation • X, Y, and Z controls can be used on the volume before animation • Speed can be adjusted using the Rotary Control as Slow, Medium, and Fast Additional Optimization – Acquisition Quality • Adjusts the resolution and sweep speed between Low, Mid, and High Additional Optimization – VR Threshold Brightness • Decreasing the threshold removes low-level echoes, • Changes the voxel saturation while increasing the threshold adds low-level echoes Contrast Opacity • Raises or lowers the percentage of contrast to enhance • Adjusts the transparency of the voxel differences in tissue Smooth Tint • Averages the edges of the voxels with adjacent • Applies assigned color shades to the gray scale voxels to smooth the volume image appearance 6 siemens-healthineers.com/ultrasound Additional Optimization – MPR Dynamic Range Map • Decreasing the threshold removes low-level echoes, • Adjusts the transparency of the voxel while increasing the threshold adds low-level echoes Tint • Applies assigned color shades to the gray scale Review ? • Select Review from the Touch Screen with the pointer, select the image for review Patient Imaging Review Report • Select the 3D/4D tab on the Touch Screen to activate the volume manipulation tools if desired 3D/4D Review • Any additional images stored while the volume is active in the 3D/4D tab will be stored as volumes; additional images stored while in the Review tab will be stored as still images siemens-healthineers.com/ultrasound 7 For the proper use of the software or hardware, please always use At Siemens Healthineers, we pioneer breakthroughs in healthcare. the Operator Manual or Instructions for Use (hereinafter collectively For everyone. Everywhere. Sustainably. As a leader in medical “Operator Manual”) issued by Siemens Healthineers. This material is technology, we want to advance a world in which breakthroughs to be used as training material only and shall by no means substitute in healthcare create new possibilities with a minimal impact on the Operator Manual. Any material used in this training will not be our planet. By consistently bringing innovations to the market, updated on a regular basis and does not necessarily reflect the latest we enable healthcare professionals to innovate personalized care, version of the software and hardware available at the time of the achieve operational excellence, and transform the system of care. training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and Our portfolio, spanning in vitro and in vivo diagnostics to image- cautions. guided therapy and cancer care, is crucial for clinical decision- making and treatment pathways. With the unique combination of Note: Some functions shown in this material are optional and might our strengths in patient twinning1, precision therapy, as well as not be part of your system. digital, data, and artificial intelligence (AI), we are well positioned to take on the greatest challenges in healthcare. We will continue Certain products, product related claims or functionalities described to build on these strengths to help overcome the world’s most in the material (hereinafter collectively “Functionality”) may not threatening diseases, enable efficient operations, and expand access (yet) be commercially available in your country. Due to regulatory to care. requirements, the future availability of said functionalities in We are a team of more than 71,000 Healthineers in over 70 countries any specific country is not guaranteed. Please contact your local passionately pushing the boundaries of what is possible in Siemens Healthineers sales representative for the most current healthcare to help improve the lives of people around the world. information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. 1 Personalization of diagnosis, therapy selection and monitoring, aftercare, and managing health. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700012410 · 15720 1124 online only · ©Siemens Medical Solutions USA, Inc., 2024

  • Freehand 3D GYN
  • 3D
  • MPR
  • gynecology