Select&GO | Set the isocenter XA70A

The video provides an overview about the isopositioning functions of the Select&GO display from XA70A upwards.
Product relevance: MAGNETOM Avanto Fit, MAGNETOM Skyra Fit, MAGNETOM Sola Fit, MAGNETOM Viato.Mobile
Target group: Basic users.
Audio: Yes.
Recommended to be viewed on the following devices: All (incl. tablet and smartphone).

In this video you will learn about the ISO positioning functions of the select and go display from XA70A upwards. During the exam, you can position the ISO center in table position in different ways. For automatic table positioning, you can either select the body region or the coil as the ISO center position. You can also change the ISO Center for positioning manually. To do this, press on Define ISO to call up the Body Regions buttons. Otherwise, click on Laser to switch on or off the crosshair for manual ISO positioning. For all automatic or manual ISO positioning settings, see the table and target positions on the homepage. The position of the Body Region button on the patient is determined by the connected coils. For an automatic table positioning, select a body region to determine the ISA Center and target. It's highlighted and marked with the ISA Center icon. Press the jog wheel for at least one second to automatically move the table into the defined ISA Center. You can also define and configure the ISA Center manually. Press the Define ISO button to define and configure the ISO center by different body regions. The selection of the body regions is determined by the connected coils. After confirming with Apply, the respective body region is highlighted and marked with the ISO center icon. The table position and target have also changed. For example, let's change the ISO center manually to head. Press Define ISO and the Body Region button Head. Press the jog wheel for at least one second to move the table into the defined ISO center, in our example to the target ISO head. Select the laser function for an additional manual positioning. Move the table by rotating the jog wheel until the crosshair points precisely on the region of interest. As soon as the table position moves to the ISO center, go to the control room and start the exam. You can find more Select and Go videos from XA70A upwards in the training platform.

Select&GO Set the isocenter Upwards XA70A SIEMENS You can position the isocenter and MAGNETOM table position in different ways. Healthineers Doe, John Body Part - Brain Automatic: Guidance Head Select the body C-Spine / Neck region or the coil as BM Spine Coil Head/Neck Coil the isocenter position. T-Spine Table Position Isocenter Target Home Coils Manual: Under Define ISO, the body regions can be set or changed as the isocenter position. Laser Click on Laser to switch on/off the crosshair for isopositioning. Define Table Position and Target info. Position of the body region buttons = connected coils. Target ISO - Laser Position Press jogwheel > 1 second to automatically move the table into the defined isocenter. Configure the isocenter using Body regions. Body Regions O Head Shoulder O Heart / Thorax O Liver O T-Spine O L-Spine Current ISO Head ancel Selection of body regions = connected coils. . Table Position 1354 mm Target ISO - Heart / Thorax O WholeBody O C-Spine / Neck Current ISO Heart / Thorax Cancel Current ISO Undefined Apply BM Spine Coill Table Position 1048 mm Target ISO - Head Select the laser function for Physio . Table Position 176 mm Rotate the jogwheel until the crosshair points on the region of interest. To start the examination, go to the control room. Detailed information for General functions & features or Register patient. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com

  • Sola
  • Skyra
  • Viato
  • Mobile
  • Fit
  • System
  • iso
  • set
  • the
  • select&Go
  • select
  • go
  • xa70
  • isopositioning
  • GO
  • display