Select&GO | Set the isocenter XA70A

The video provides an overview about the isopositioning functions of the Select&GO display from XA70A upwards.
Product relevance: MAGNETOM Flow.Platform
Target group: Basic users.
Audio: Yes.
Recommended to be viewed on the following devices: All (incl. tablet and smartphone).

In this video, you will learn about the ISO positioning functions of the Select and Go display from XA70A upwards. During the exam, you can position the ISO center in table position in different ways. For automatic table positioning, you can either select the body region or the coil as the ISO center position. If a Biomatrix contour coil is connected, the position sensor can be used for automatic ISO positioning. You can also change the ISO Center for positioning manually. To do this, press on Define ISO to call up a sub menu. Also, if a laser light is configured, you can use the crosshair for ISO positioning. For all automatic or manual ISO positioning settings, see the table and target positions on the homepage. Press the Guidance Info button to find further help for setting the ISO center. According to this instruction, the ISO center can only be set between zero to 130 centimeters. The position of the Body Region button on the patient is determined by the connected coils. Select a body region to determine the ISO center and target position for the automatic table movement. It's highlighted and marked with the ISO center icon. Press the jog wheel for at least one second to automatically move the table into the defined ISO center. Plug and position the Biomatrix Contour SM or L coil at the table. The coil is automatically displayed and selected as the ISO target. The Contour coils are equipped with a Biomatrix position sensor. The position of the button depends on where the coil is placed and sensed on the body. You can also define and configure the ISO center manually. Press the Define ISO button to define and configure the ISO center by body regions, Biomatrix contour or the keypad. There are different body regions displayed to define the ISO center. The selection of the body regions is determined by the connected coils. After confirming with Apply, the respective body region is highlighted and marked with the ISO center icon. The table position and target have also changed. For example, let's change the ISO center manually to Head, press Define ISO and the Body Region button. Head. Press the jog wheel for at least one second to move the table into the defined ISO center, in our example to the target ISO head. If a contour coil is connected, you can select the Biomatrix contour button in Define ISO. To change the ISO center, select or deselect the coil coverage region. Select the keypad to manual positioning. Read off the number on the scale that corresponds to the region of interest. Use the ISO center information as your guide. Enter the number and confirm with the Apply button. The ISO target is updated accordingly. Select the laser function for an additional manual positioning. Move the table by rotating the jog wheel until the crosshair points precisely on the region of interest. As soon as the table position moves to the ISA center, press the Start button. You can find more Select and Go videos from XA70A upwards in the training platform.

45 00:05 00:04 00:03 00:02 00:01 00:00 Select&GO Set the isocenter MAGNETOM Flow.Platform upwards XA70A SIEMENS You can position the isocenter and MAGNETOM Flow table position in different ways. Healthineers Doe, John Body Part - Brain Guidance C-Spine / Neck BM Spine Coil Head/Neck Coil T-Spine Physio Table Position Isocenter Target Home Laser Automatic: You can select the body region or the coil as the isocenter position. If a BioMatrix Contour Coil is connected, the position sensor can be used for isopositioning. Head Manual: Define ISO calls up a submenu to set or change the isocenter for positioning. If a laser is configured, you can use the crosshair for Table Position and Target info. Press Guidance to find further help for Set the isocenter. Register Patient undefined Shoulder Spine Hip Knee Set Isocenter Table Position Home Target ISO - Laser Position 0-130 cm Coils Position of the body region button = connected coils. Select the body region or the coil as the isocenter position. Press jogwheel > 1 second to automatically move the table into the defined isocenter. . Table Position Isocenter Start Plug and position the BM Contour S, M or L Coil at the table. COIL PLUGGED BM Contour L Coill Define Target ISO - BM Contour L Coil The coil is automatically displayed and selected as the iso target. The contour coils are equipped with a BioMatrix Position Sensor. The position of the button depends on where placed and sensed on the body. where the coil is Body Regions BM Contour Keypad O WholeBody O Head O C-Spine / Neck O Shoulder O Heart / Thorax O Liver O T-Spine O L-Spine O Hip / Pelvis Current ISO Head Cancel Selection of Body regions = connected coils. Apph Table Position 1354 mm Current ISO Heart / Thorax Current ISO Undefined Table Position 957 mm Target ISO - Head If a contour coil is connected, you can select the BM Contour button. BM Contour S Coil BM Contour M Coil Current ISO BM Contour M Coil Select the Keypad for manual positioning. < Back Isocenter Info Read off the number from the scale. Range 0 - 129 Current ISO Laser Position Apply . Table Position 757 mm Target ISO - 45 Select the laser function for Rotate the jogwheel until the crosshair points precisely on the region of interest. As soon as the Table Position moves to Isocenter, press the Start button. Exam Starts in ... Stop Detailed information for General functions & features or Register patient and start the exam. Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Healt

  • Flow
  • select&Go
  • select
  • go
  • xa70
  • isopositioning