Select&GO | General functions & features XA70A

The video provides an overview of the general functions & features of the Select&GO display from XA70A upwards.
Product relevance: MAGNETOM Avanto Fit, MAGNETOM Skyra Fit, MAGNETOM Sola Fit, MAGNETOM Viato.Mobile
Target group: Basic users.
Audio: Yes.
Recommended to be viewed on the following devices: All (incl. tablet and smartphone).

In this video you will learn about the general functions and features of the Select and Go display from the XA70A upwards. You can operate the system and the patient table using the control units located on the magnet cover. The control units consist of a Select and Go touch display and a jog wheel. With software version XA70A and higher, a new display design and the function patient registration is available. You will learn more about these individual components during the training. Show and edit registered patient data. Automatic table positioning. Change the patient orientation. Table lock and unlock table position and target info, comfort and settings menus. Guidance on the different body parts. Connected coils. Toolbar. Laser function for manual positioning. You can gain access to the pre registered patient data from the Radiology Information System or the Single Acquisition Workplace. You can edit the patient orientation or you can edit the demographics as needed. Please note that other settings and patient information are read only and can only be changed in the single acquisition workplace or in the Risks. Adjust the settings for patient comfort and control the settings for the Select and Go displays. You can turn off all touch functions here. This can be useful, for example, to clean the displays. You can change the settings for both displays simultaneously. Prepare the patient for various examinations with a step by step guide under Define ISO. You can configure the ISO center manually using the body Regions buttons. Monitor physio signals and utilize the guide for electrode positioning. If a Biomatrix coil with beat sensor is connected, additional guidance for positioning is available. Moreover, you can view extra data on the physio card when it's linked with the Biomatrix coil. Select this function to fix the table position. Select the function above to change the patient orientation. Please note this is only available without my Exam 3D camera. Select the laser function on the bottom of the display for manual positioning. Select the required body region for automatic ISO positioning. Press and hold the jog wheel for at least one second to move the table into the ISA center automatically. After successful ISO positioning, go to the control room and start the exam. You can find more Select and Go videos from XA70A upwards in the training platform.

06:44 5/28/2024 06:36 45 11 176.37 2.1. 176. 5/28/1979 76.37 Select&GO General functions & features Upwards XA70A SIEMENS MAGNETOM The control units: The touch display and a jogwheel. > XA70A software: New display design Patient registration Register Patient Body Part - undefined Guidance Coils C-Spine / Neck BM Head/Neck Coil 0 deg BM Spine Coil T-Spine Deline . Table Position Home Target ISO - Head Show/edit registered patient data Automatic table positioning Change the patient Physio orientation Table lock/unlock Laser Table Position and Target info Comfort and Settings menus Guidance on the different body parts Connected coils Tool bar Laser function for manual positioning Pre-registered patient data from the RIS or the syngo Acquisition Workplace. 3 Procedure(s) Scheduled Today Patient Detalls Procedure Date & Time Doe, John 2024.05.28-06:35:34-DST-1.3 ... Snoopy, XY Loading details ... Save Demographics Snoopy XY M (Male) Date of Birth* Examination Details Implant Scanning Patient Orientation Edit Feet First Prone Medical Alerts Allergies Exami No Implant Any Polarization Gende M (M Head First Supine Prone Left Lateral Right Lateral Feet First Superman Medic Wrist Supine Elbow Wrist Prone Elbow Prone Apply RF Transmit Mode Feet First Supine Exam Control the settings for patient comfort. Settings Comfort Headphones Bore Light Speakers Cleaning Mode Brightness Right Display for the Select&GO displays. All Displays off peakers Guidance in preparing the patient for various examinations. Head Shoulder Hip Knee Set Isocenter Guidance: Head Manual: Configure the isocenter using the Body Regions buttons. Body Regions O WholeBody O Head O Shoulder O Heart / Thorax O Liver O T-Spine Current ISO Head Cancel Physio signals and guidance for ECG/ Beat Sensor. Beat Sensor Cardiac Resp PT ECG To ensure optimal electrode contact: If necessary, shave skin outside the examination room. Prepare skin with prepping gel, avoid solutions containing alcohol. Always use new electrodes. Never reposition used electrodes. To ensure optimal signal for Contour S Coil: (1) Position the sensor directly over the patient's heart. (2) Route the cable toward the foot end of the table. To ensure optimal signal quality for cardiac triggering, it is recommended to use a Contour M or Contour S Coil rather than a Contour L Coil. Resp Cushion Relearn Signals . Table Position Locked Target ISO - 60 Fix the table position. orientation. Please note: Only available without 3D Camera. isopositioning. Target ISO - Laser Position Brain Head/Neck Coil Automatic: Select the required body region for Press jogwheel > 1 second to automatically move the table into the . Table Position Isocenter Target Home To start the examination, go to the control room. Define Detailed information for Isopositioning or Register patient. Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com

  • select&Go
  • select
  • go
  • xa70
  • general
  • functions
  • features
  • Sola Fit
  • Skyra Fit
  • Viato.Mobile