
Scopio X100 Peripheral Blood Smear Scopio Learn Assessment
This assessment includes content covered for the peripheral blood smear (PBS) application on the X100 in Scopio Learn.
Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Untitled Scene Master Template HILS2218 | Effective Date: 25 Mar 2022 ? Scopio X100 Scopio Learn Assessment This assessment covers the content on Scopio Learn for the X100 scanner. Welcome Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com ? Disclaimer Assessment Start ? This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. You may repeat the assessment as many times as needed. Assessment Select the best answer. ? Back of the X100 Inside of the X100 Question 1 of 30 Where is the X100 scanner label located? Right side of the X100 Left side of the X100 Multiple Choice Where is the X100 scanner label located? The X100 scanner label is not located on the inside. The X100 scanner label is not located on the left side. The X100 scanner label is not located on the right side. Select the best answer. ? The processing unit Secure hospital network Question 2 of 30 What controls the X100 scanner and serves the Full-Field PBS Application? The X100 Google Chrome Multiple Choice What controls the X100 scanner and serves the Full-Field PBS Application? Secure hospital network does not control the scanner. Google Chrome does not control the scanner. The X100 does not control the scanner. Select the best answer. ? 1 Question 3 of 30 How many drop(s) of oil are applied to the slide? 2 3 4 Fill in Blank How many drop(s) of oil are applied to the slide? 4 drops of oil are not applied to the slide. 3 drops of oil are not applied to the slide. 2 drops of oil are not applied to the slide. Select the best answer to complete the statement. ? Quick Scan Question 4 of 30 The ________ button is used to initiate a scan from the X100. Scanner Slide Tray Scan Fill in Blank The ________ button is used to initiate a scan from the X100. The scan button is not used to initiate a scan. The slide tray button is not used to initiate a scan. The scanner button is not used to initiate a scan. Select the best answer to complete the statement. ? standby, ready to scan Question 5 of 30 The steady blue LED indicates ________. scanning in progress application warming up error Fill in Blank The steady blue LED indicates ________. A red LED indicates there is an error. An orange LED indicates the application is warming up. A waving blue LED indicates scanning in progress. Select the correct designated area from the orange boxes, then select Submit below. Question 6 of 30 Where can you view the QC Log to review QC history? Hotspot This is the Review Case button. This settings icon enables a Lab Admin to manage clinical settings and users and an IT Admin to manage users and security. This icon enables you to scan slides and control the scanner. You did not select a designated area. Select the best answer. ? 10 Unlimited Question 7 of 30 What is the maximum number of cases that can be starred on the X100? 200 100 Multiple Choice What is the maximum number of cases that can be starred on the X100? 100 cases can be starred. More than 10 cases can be starred. Less than 200 cases can be starred. Select the best answer. ? Only cases selected by the user Oldest cases created Question 8 of 30 Which cases are deleted first from the Case Gallery? Cases are never deleted Cases older than 60 days Multiple Choice Which cases are deleted first from the Case Gallery? The oldest cases created are deleted first. The oldest cases created are deleted first. Cases are deleted in a certain order. Select the best answer. ? Edge to Edge Full Field Question 9 of 30 Which scan mode scans the monolayer laterally? Rapid Monolayer Monolayer Multiple Choice Which scan mode scans the monolayer laterally? This scans the monolayer and feathered edge area to locate and classify 200 WBCs and perform PLT count in 10 HPF. This scans the monolayer only to locate and classify 200 WBCs and perform PLT count in 10 HPF. This scans the monolayer only to locate and classify 100 WBCs and perform PLT count in 10 HPF. Select the best answer to complete the statement. ? optimal analysis area of the slide Question 10 of 30 The green rectangle indicates ________. perspective area observed monolayer detection area 100 FOVs Fill in Blank The green rectangle indicates ________. The green rectangle does not indicate 100 FOVs. The green rectangle does not indicate the monolayer detection area. The green rectangle does not indicate the perspective area observed. Select the applicable image. ? Which image shows the indicator of the optimal analysis area of the slide? Question 10 of 30 Pick One This image shows the slide in low power. This image shows a WBC. Select the best answer. ? WBC differential Information regarding the X100 status Question 11 of 30 What does the ‘Slide Summary’ Panel display? Information regarding the selected case CBC results Multiple Choice What does the ‘Slide Summary’ Panel display? Slide Summary panel does not display information regarding the X100 status. Slide Summary panel does not display CBC results. Slide Summary panel does not display WBC differential. Select the correct designated area from the orange boxes, then select Submit below. Question 12 of 30 Where can the Brightness, Contrast, Saturation, and Gamma parameters be adjusted? Hotspot This enables navigating, marking, and deleting cells. These icons are for screen arrangement. This enables zooming-in and out on the high-resolution Full Field image. You did not select a designated area. Select the best answer. ? Main Toolbar Detection Toolbar Question 13 of 30 Which toolbar does a qualified user use to navigate to, mark, and delete cells? Analysis Results Toolbar Upper Toolbar Multiple Choice Which toolbar does a qualified user use to navigate to, mark, and delete cells? You cannot navigate to, mark, and delete cells from the Detection Toolbar. You cannot navigate to, mark, and delete cells from the Upper Toolbar. You cannot navigate to, mark, and delete cells from the Main Toolbar. Select the best answer. ? Artifacts Unknown Question 14 of 30 How will WBC detections be classified when below classification thresholds? Unclassified Other Multiple Choice How will WBC detections be classified when below classification thresholds? Cells are not classified as Unknown when below classification thresholds. Cells are not classified as Other when below classification thresholds. Cells are not classified as Artifacts when below classification thresholds. Select the best answer. ? Combines both Full-Field Review tab with Report tab Combines both WBC and RBC results Question 15 of 30 What is observed when viewing ‘Split View’? Combines both scan and list viewing options Combines WBC, RBC, and PLT results Multiple Choice What is observed when viewing ‘Split View’? Split View combines scan and list viewing options. Split View combines scan and list viewing options. Split View combines scan and list viewing options. Select the best answer. ? Comment within each abnormal cell Select the Analysis Results Toolbar to mark cell as abnormal Question 16 of 30 How can individual cells be manually marked as abnormal? Select ‘Mark as Abnormal’ option AI-DSS will always mark a cell as abnormal Multiple Choice How can individual cells be manually marked as abnormal? Analysis Results Toolbar does not mark a cell as abnormal. AI-DSS does not always mark cells as abnormal. A comment will not mark a cell as abnormal. Select the best answer. ? nRBCs and Smudge Cells nRBCs, Smudge Cells, Artifacts, and Unclassified Question 17 of 30 Which of the following cells are included in ‘Additional Cells’? nRBCs, Smudge Cells, Artifacts, and Others Artifacts and Others Multiple Choice Which of the following cells are included in ‘Additional Cells’? Unclassified cells are not included in Additional Cells. Artifacts and Others are not the only cells included in Additional Cells. nRBCs and Smudge Cells are not the only cells included in Additional Cells. Select the best answer to complete the statement. ? Size and/or color, Shape, Irregular Distribution, Inclusions Question 18 of 30 The four sections of the ‘RBC Abnormalities Panel’ are ________. Shape, Color, Inclusions, Irregular Distribution Size, Shape, Color, Inclusions Color, Shape, Size, Irregular Distribution Fill in Blank The four sections of the ‘RBC Abnormalities Panel’ are ________. These are not the four sections of RBC Abnormalities Panel. These are not the four sections of RBC Abnormalities Panel. These are not the four sections of RBC Abnormalities Panel. Select the best answer. ? AI-DSS grades PLT abnormalities Only PLT clumping can be graded manually Question 19 of 30 How are PLT abnormalities graded? PLT abnormalities are graded manually PLT abnormalities cannot be graded Multiple Choice How are PLT abnormalities graded? PLT clumping is not the only abnormality to be graded manually. PLT abnormalities can be graded. PLT abnormalities are not graded by AI-DSS. ? Select three (3) answers. Question 20 of 30 What are the three report sign off options? WBC RBC Abnormalities PLT Multiple Answer One or more answers are incorrect. Select the best answer. ? Removing the left side panel Turning off the Application Question 21 of 30 What is the first step in the lens cleaning process? Turning off the X100 Removing the objective from the X100 Multiple Choice What is the first step in the lens cleaning process? This is not a step in the lens cleaning process. This is not a step in the lens cleaning process. This is the second step. Select the best answer. ? Removing the side panels Removing broken cover slips Question 22 of 30 What is the vacuum tool used for? Removing debris from the lens Removing broken slides Multiple Choice What is the vacuum tool used for? The vacuum tool is not used to remove broken cover slips. The vacuum tool is not used to remove broken slides. The vacuum tool is not used to remove debris from the lens. Select the best answer. ? ‘X’ pattern Any motion is acceptable Question 23 of 30 When cleaning the lens with a cotton swab, what type of motion should be used? Circular motion Zig-zag pattern Multiple Choice When cleaning the lens with a cotton swab, what type of motion should be used? ‘X’ pattern should not be used. You should clean in a particular motion. A zig-zag pattern will spread the dirt. Select the best answer to complete the statement. ? Equal to or above 95% Question 24 of 30 Results ________ indicate QC passing. Equal to 90% Of 99% Above 95% Fill in Blank Results ________ indicate QC passing. Results equal to or above 95% indicate QC passing. Results equal to or above 95% indicate QC passing. Results equal to or above 95% indicate QC passing. Select the best answer. ? Specific QC slide designated by the site Specific QC slide designated by Scopio Question 25 of 30 What type of slide should be used for the QC test? Freshly made, same day slide Slide made within the past 24 hours Multiple Choice What type of slide should be used for the QC test? Scopio does not provide a QC slide. The QC test slide should be freshly made. The QC test slide should not be a specific slide designated by the site. Select the best answer. ? Settings > User Management Settings > License Question 26 of 30 Where can a qualified user specify the name of the site at which the Full-Field PBS System is installed and upload the site’s logo? Setting > General Settings > Case Review > Reported Fields Multiple Choice Where can a qualified user specify the name of the site at which the Full-Field PBS System is installed and upload the site’s logo? Select the best answer. ? Hebrew, Italian, German, Spanish Italian, German, Spanish, Portuguese Question 27 of 30 Besides English, which four languages can the application be viewed in? French, Italian, German, Spanish French, Italian, Spanish, Portuguese Multiple Choice Besides English, which four languages can the application be viewed in? Hebrew is not an available language. Portuguese is not an available language. Portuguese is not an available language. Select the best answer. ? 200K - 400K 100K - 375K Question 28 of 30 What is the default PLT estimate reference interval? 150K - 450K 250K - 500K Multiple Choice What is the default PLT estimate reference interval? Select the best answer. ? Credentials, Title, Username, Email Title, Phone, Email Question 29 of 30 Which user information is optional? Credentials, Title, Phone, Email Email and Phone Multiple Choice Which user information is optional? More user information than just title, phone, and email are optional. More user information than just email and phone are optional. Username is not optional. Select the best answer. ? 5 12 Question 30 of 30 A password must have at least how many characters? 8 10 Multiple Choice A password must have at least how many characters? A password must have at least 8 characters. A password must have at least 8 characters. A password must have more than 5 characters. Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the Scopio X100 Scopio Learn Assessment. Completion details, certificates tab Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Tmeline Select the CC icon to display closed captioning (subtitles). Click Next to continue. Next Caption Icon Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Some images may have a magnifier icon. Select the image to see an enlarged view. Select it again to return to the normal view. Click Next to continue. Next Zoom Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Videos should default to the optimal resolution. However, to change the video resolution select the gear icon. Click Next to continue. Next Video Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 QR700004490 | Effective Date: 16 Jan 2024 1.1 Welcome 1.2 Disclaimer 1.3 Assessment 1.4 Multiple Choice 1.5 Multiple Choice 1.6 Fill in Blank 1.7 Fill in Blank 1.8 Fill in Blank 1.9 Hotspot 1.10 Multiple Choice 1.11 Multiple Choice 1.12 Multiple Choice 1.13 Fill in Blank 1.14 Pick One 1.15 Multiple Choice 1.16 Hotspot 1.17 Multiple Choice 1.18 Multiple Choice 1.19 Multiple Choice 1.20 Multiple Choice 1.21 Multiple Choice 1.22 Fill in Blank 1.23 Multiple Choice 1.24 Multiple Answer 1.25 Multiple Choice 1.26 Multiple Choice 1.27 Multiple Choice 1.28 Fill in Blank 1.29 Multiple Choice 1.30 Multiple Choice 1.31 Multiple Choice 1.32 Multiple Choice 1.33 Multiple Choice 1.34 Multiple Choice
- scopoi
- scpoio
- scopeo
- 100XHT
- 100X
- HT100