Scan Physics Density Phantom and Placing ROIs
This job aid will assist with scanning a density phantom.
Scan Physics Density Phantom & Placing ROIs on a go. System SOMATOM go.Sim & SOMATOM go.Open Pro (VA40) Radiation Oncology sites scan a density phantom and perform HU (Hounsfield Unit) readings for dose curves. Density Phantom scans can be performed with or without a topogram. As with all Siemens Healthineers workflows, several methods exist for performing this function. Using a Topogram Zeroing the table at the internal bore lasers is not required, but it does make it easier to find the middle of the phantom. H3 1. Select the desired scan protocol. The default RTP (Radiation Therapy Protocol) scan mode is spiral but can be changed to sequential in the Exam Designer. Collimation can be set by selecting the RTP Head (16 cm) or the RTP Abdomen protocol (32 cm). This example uses the spiral pelvis protocol. Browse Protocols Protocol: RTP Pelvis [factory] Protocol Moben Management [factory] mant with Duect AD for Indications: radiotherapy planning of the pelvis region, w/ Topogram planning for moving timon, wiwo CM Topogram Respiratory Mobi WO CM Protocat NIP Abdomen [factory -Scan modes: RoutineSpiralAdultPelvis Insertions radiotherapy planning of the abe Protocol RIP Abdomen DE [tactory] indications radetherapy planning of the abdome region, wo CM Topogram Abdomen 100 cm) Protocol: RFP Extremity |factory] indications radiotherapy planning of the exdemibies Topogram Scan modes: RoutineSpiralAdultExtremsies Extremity Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers 2. Perform a topogram of the density phantom. 3. Adjust the Scan and Recon parameters as needed. Set the appropriate scan range. Recon Favori ... General Recon | Recon&GO Image Impression Recon Box Physio Recon Auto Tasking | Inline Options Scan/Recon Slice Thickness Increment [mm] [mm] Window@120kV Kernel Fix Axial FAST Planning Inline Results Multi Recons Density ROI Phantom 1.00 Or40 53 1.00 1.00 Pelvis Qr40 On None None None 4. Scan the phantom. 5. Evaluation of the phantom can be performed at the scanner in View&GO or other facility programs. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 2 of 12 Evaluation of the Scan in View&GO 1. Load the desired scan series and scroll to the desired slice position. CTQA CTQA "06/28/2003, 20Y CURRENT 07/05/2023 Body Secn 3.00 Or40 83 [2] 12:28:03 13 PM SPI 201 2 IMA 27 SP H1272.0 kV 120 Eff. mAs 44 Quality ref. MAS 155 0.5 GT 0.0 600 O/D Qr40f83n3 :0268C:0AhAAS1atA 2. Using the upper right corner menu, select ROI Circle. Distance Line ROI Circle O SOMAT Pixel Lens syhe Arrow 3. Left-mouse-click, hold, and drag the mouse to get the desired size. SOMATOM syng Min / Max: - 1019 HU/-977 HU Mean/SD: -996 HU/6 HU Area: 14.67 cm2 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 3 of 12 4. Once the desired size is determined, it is possible to copy the same size ROI. Right-mouse- click on one of the white dots and select Copy Measurement. Delete Measurement SON Copy Measurement Min / Max: - 1019 HU/-977 HU Mean/SD: -996 HU/6 HU Area: 14.67 cm2 5. Right-mouse-click and select Paste to the cursor position. go 71. Clip Box Den Pro 0120 Fit to Segment O ROI Circle * 3D Reference Point Distance Line -i- Marker Paste to the cursor position 3D Show in 3D An alternative is to use the 4-headed arrow cursor and drag the circle to the next position. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 4 of 12 6. Repeat steps until all desired areas have been measured. 7. Document readings by writing down the values, taking a photo, or using the Snapshot feature in the bottom left of the workspace. This will place a snapshot of the active pane in the Series list. This can be exported if desired. Note: The text in the snapshot may be small and difficult to read. Series X Favorite Tools x Add Study Sanciona O Current 1. 715/2023 Distance ROI Cirde Parallel Line Ranges VIEN&GO [100. Snapshot Sim&GO Export Image EN 2:03 PM Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 5 of 12 Building Scan Protocol for Zero Table Feed using Sequential Scan Mode This method is used to center the scan in the middle of the phantom and not perform a topogram. H3 1. Navigate to the Exam Designer. 2. Unhide RTP Abdomen [factory] default (if necessary) for the 32cm collimation or the RTP Head [factory] default for 16cm collimation. The RTP Abdomen is used for this example. Adult RTP (14) RTP Thorax_with Contours RTP Head [factory] RTP Head DE [factory] RTP Head and Neck [factory] RTP Head and Neck DE [factory] RTP Thorax [factory] RTP Respiratory Motion Mana RTP Abdomen [factory RTP Abdomen DE [factory] RTP Pelvis [factory] RTP Extremity [factory] RTP Direct Density commissio ... RTP Twinbeam DE commissio ... RTP Twinspiral DE commissio ... 3. Load the Abdomen [factory] protocol. 4. Delete the topogram. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 6 of 12 5. Go to Scan Parameters. 6. Under General Scan > Accessible Scan Modes, select RoutineSequenceAdultAbdomen. Under the Scan Mode, select RoutineSequenceAdultAbdomen. Protocol Scan Favorites General Scan Pose Timing Config Physio Scan Contrast Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Inline Options Find/Replace Scan/Recon Scan/Recon Region Scan Mode Accessible Scan Modes Decision Trees Tilt [o] Acquisition [m RTP Abdomen [factory] (Adult) Topogram Abdomen Scanplanning TopoAdultSn Scanplanning TopoAdultSn Off 6 x 0.60 Abdomen RoutineSequenceAdultAbdomen RoutineSpiralAdultAbdome .. 64 x 0.6 v RoutineSpiralAdultAbdomen RoutineSpiralAdultAbdomenFlexdose RoutineSpiralAdultAbdomenSn v RoutineSequenceAdultAbdomen 7. Turn off CareDose and Care kV. Set appropriate KV (typically 120KV). Scan Favorites General Scan Dose Timing Config Physio Scan Contrast CH Scan/Recon CARE Dose4D KV Eff. MAS CTDIvol [mGy] DLP Dose Notification Dose Notification & CARE KV [mGy "cm] CTDIvol [mGy] DLP [mGy*cm] Shaped Filter Perfusion Liver Off 80 197 (32 cm) 80.8 997 0.00 0.0 Standard 8. Under Timing, adjust the Exam Time to 12.5, Cycle Time to 1.5, None for Patient In- struction, and Breathhold Time and Breathing Time to 1.0. Protocol Scan Favorites General Scan Dose Timing Config Physio Scan Contrast Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Inline Options Find/Replace Scan/Recon Timing Scan/Recon Rot. Scan Time Exam Time Cycle Absolute Start Time [s] Patient Instruction Breathhold Breathing Time [s] [s] Delay [5] Time [s] Abdomen Density Phantom Sequence (Adult) Abdomen 0.50 Full 0.50 12.50 1.50 None 2.0 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 7 of 12 9. Under General Recon, set Slice Thickness to 10 for 2 images in View&GO. If more slices are needed, decrease the slice thickness. Protocol Scan Favorites General Scan Dose Recon Favorites General Recon Recon&GO Image Impression Find/Replace Scan/Recon General Recon Scan/Recon Slice Thickness Increment No. of [mm] [mm Comment Images Abdomen Density Phantom Sequence (Adult) Abdomen Abdomen 10.00 Qr40 S3 10.00 10.00 10. Under Recon Box, select None for Fast Planning and adjust the field of view (Width and Height) as desired. 1. Select Protocols 2. Modify Protocols 3. Confirm Changes Protocol Scan Favorites General Scan Dose Timing Config Physio Scan Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Find/Replace Scan/Recon Recon Box Scan/Recon Image Image Order FAST Planning Matrix Size Matrix Width Mirrorin Orientation [mm] [mm] [mm] [mm] g No Move Demo (Adult) Perfusion Liver Perfusion Liver 10.00 Br40 2.38s Axial Head to Feet None Auto (5 .. Square 300.00 300.00 0.00 0.00 None 11. Turn off any auto tasking functions not needed and turn on Auto View&GO. 1. Select Protocols 2. Modify Protocols 3. Confirm Changes Protocol Scan Favorites General Scan Dose Timing Config Physio Scan Contrast Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Inline Optic Find/Replace Scan/Recon Auto Tasking X Scan/Recon Auto Recon Recon Ref. Body Part Series Transfer Auto Local syngo. via Lines Splitting View&GO View&GO Dataroles Auto Printing 5y190-via Examined NOOUS Applicati ... Workflow Datarole No Move Demo (Adult) Perfusion Liver Perfusion Liver 10.00 Br40 2.38s On Off ABDOMEN Off On None Off None None Auto 12. Rename the scan and select Confirm Changes. 13. In Exam Designer, the new protocol can be moved to a different location, such as the Spe- cials folder, using drag and drop. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 8 of 12 Scan with No Topogram 1. When ready, register the patient and load the protocol. 2. Position the phantom at the desired location. H3 3. Select Confirm and Go. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 9 of 12 4. Change the Scan Length to 10.0mm and note the change in scan time. Abdomen Density Ph ... +m Pellent position Dernity Phantom Scas Length 145 130 Beconstruction Confirm patient poshion ª Cantum 0.5 5. Under the Table Position icon, select Cancel Move. If this is not selected, the table will move 0.5 mm before scanning and will Table Position X make the image off by 0.5 mm. Note: The Position was -500 since the table was not zeroed. Position -500.0 mm Height 135.0 mm Tilt O Cancel Move Confirm GO Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 10 of 12 6. Perform the Scan. 7. If Auto View&GO is on, the scan will load automatically. If Auto View&GO is off, manually load the scan from the Patient Browser into View&GO. Note: Skip this and subsequent steps if evaluation is performed in another program. 8. If desired, change the layout to 1X1 for better viewing. The slice position is noted in the upper left corner. Scroll to the desired location. K demo, no move demo *06/19/1973, 50Y CURRENT 06/19/2023 No Move Demo 10.00 Br40 2.38s [1] 7:26:57.42 PM SEQ 100 1 IMA 2 SP F500.0 9. Follow the ROI placement instructions above. 10. Save work and export if appropriate. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 11 of 12 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemens Shanghai Healthcare Sector Henkestr. 127 40 Liberty Blvd. Medical Equipment Ltd. 91052 Erlangen Malvern, PA 19355-9998 USA 278 Zhou Shu Road Germany Telephone: +1-888-826-9702 Shanghai 201318 Phone: +49 9131 84-0 Customer Care Telephone: P.R. China https://www.siemens-healthineers.com +1-800-888-7436 Telephone: +1 847 304 7700 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06 October 2023 | QR700001522 Healthineers Page 12 of 12
- mm radiation therapy image suite
- rtis
- somaris 7
- somaris 10
- mip
- phantom
- density
- topogram
- evaluation