Siemens Healthineers Academy

SAR Assistant – syngo MR XA51

This Job Aid provides information about updates to Solving SAR Parameter Conflicts.

SIEMENS Healthineers SAR Assistant – syngo MR XA51 OX Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date: 03 SEP 2022|HOOD05162003299298 Effective Date 03 SEP 2022 | HOOD05162003299298 Unrestricted © Siemens Healthineers, 2022 Updates to Solving SAR Parameter Conflicts SIEMENS Healthineers Updates to Specific Absorption Rate (SAR) Assistant pull-down. SIEMENS >> head >> library >> T1 >> t1_se_sag ? × General 0 2:53 min 0.7x0.7x5.0 mm3 ៛ 1.00 • Reduce Slices is no longer an available | Auto Protocol Parameters parameter option Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands RF Pulse Type has been added as an Execution Part 1 Part 2 Assistant • additional parameter option Image Management SAR Assistan TR Auto Load Off You can combine and/or put in order the Copy References Flip Angle Max. TH Flip Angle > TR parameters used to resolve SAR conflicts . Allowed Delay Flip Angle > TR > RF Pulse Type Flip Angle > RF Pulse Type Please note: The selection and combination Flip Angle > RF Pulse Type > TR TR of parameters might have an impact on the TR > Flip Angle image quality. TR > Flip Angle > RF Pulse Type TR > RF Pulse Type TR >> RF Pulse Type > Flip Angle RF Pulse Type RF Pulse Type > Flip Angle RF Pulse Type > Flip Anale > TR Noch schöne screenshots OK Cancel 2 Effective Date: 03 SEP 2022|HOOD05162003299298 Unrestricted © Siemens Healthineers, 2022 Updates to Solving SAR Parameter Conflicts SIEMENS Healthineers You can adapt manually the maximum (TR) SIEMENS >> head >> library >> T1 >> t1_se_sag ? X or minimum (Flip Angle) on the SAR General @ 3:07 min Auto @ 0.7x0.7x5.0 mm3 1.00 Protocol Parameters Assistant parameter card. Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands Execution Part 1 Part 2 Assistant Adjusted values (according to their min/max Image Management SAR Assistant TR > Flip An ... TR > Flip Angle > RF Pulse Type settings) of the previous parameters are kept Auto Load Min Flip Angle 90 - deg Copy References during solving. Max. TR 650.0 % ms Allowed Delay 30 This makes the adjustment of scan parameters for SAR sensitive examinations even more flexible. Please note: The selection and combination of parameters might have an impact on the image quality. OK Cancel 3 Effective Date: 03 SEP 2022|HOOD05162003299298 Unrestricted © Siemens Healthineers, 2022 Updates to Solving SAR Parameter Conflicts SIEMENS Healthineers In case the SAR Assistant has not been able to find a solution based on the selected SAR Limit(s) Exceeded ? X parameter(s), the SAR Limit(s) Exceeded dialog box will appear. Step 10 - cine_trufi_retro_4CH 1 • Operating Mode shows the current operating mode. You can choose between Normal Mode or First Level mode. BORE Temperature 21,0 ºC 2 1 Operating Mode • Protocol Parameters shows the current solution options that lower the SAR below the threshold. Current Measurement Normal Mode • Example: We set the TR to 650ms and the Flip Angle to 90 degrees (see Next Measurement Normal Mode Tra: screenshot on page before). If the SAR Assistant TR maximum value set isn't First Level high enough to resolve the SAR issue, then the SAR Limit(s) Exceeded window opens. Protocol parameter proposals are displayed to adapt the Flip Angle or 2 Protocol Parameters the RF Pulse Type. Current Recommended Flip Angle • Please note: If the SAR Assistant parameters you selected on the Sequence > 90 deg 61 deg Assistant parameter card failed, then no protocol parameter proposals are RF Pulse Type Fast Low SAR displayed on SAR Limit(s) Exceeded dialog box. 3 • Open Protocol button: Select if you want to open the protocol to make additional parameter modifications to solve the SAR Limit(s) Exceeded conflict. OK 3 Open Protocol Skip Please note: The selection and combination of parameters might have an impact on the image quality. 4 Effective Date: 03 SEP 2022|HOOD05162003299298 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 5 Effective Date: 03 SEP 2022|HOOD05162003299298 Unrestricted © Siemens Healthineers, 2022

  • sar assistant
  • syngo MR
  • xa51
  • syngo mr