Atellica® Solution Assay Status Job Aid Version 1.26 and Above

This job aid provides instructions on how to use the Assay Status screen on the Atellica® Solution.

Atellica® Solution Assay Status Job Aid SIEMENS Healthineers The Assay Status screen allows you to review that the status of ‹ n Reagent > Assay Status 8 LabManager all assays for each analyzer. Provides a high-level view of the Filters Tx Clear < tasks needed to be able to process samples on each analyzer. Filters: Status: All Assay: All Sample Type: All CH Assays (21) Status All Assay Sample Type CH-01 CH-02 CH-03 CI-01 1. Navigate to the Assay Status screen Sample Type 2 v Amylas Serum QC Needed V V V 2. If desired, filter by assay type or search for an assay Q Search 3 CH-01 CH-02 CH-03 CI-01 AAG AFP 3. Check the status of the assays for each analyzer aHAVM aHCV Lot Lot Callbration Packs/Wells Loaded Pack Ca QC Satisfied Alb AlbP 625702 Yes 625702-23220:Well1 Yes No • The assays are grouped by CH Assays and IM Assays ALT Amylas 625702-23220:Well2 NIA NI Bnz200 625702-23221:Well1 BNP N/A NIA • For each assay, the status on each analyzer is shown BR C3 625702-23221:Well2 N/A N/A Possible statuses include: Ca CA125 Carb CEA Amylas Plasma V V V V Checkmark – all is good Chol2 CKMB 5hz200 Urine V Disabled V QC Needed V o CL Cor C3 Serum V V QC Neede V V QC Needed DHDL Dlg o IM Assays (17) o Calibration Needed Related Reagent Overview Calibration Due QC Statistics Orders Assay List QC Needs o Missing Reagent o Disabled – test is disabled on that analyzer 1 Effective Date: 09-FEB-2022| HOOD05162003253246 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 2 91052 Erlangen, Germany Effective Date: 09-FEB-2022| HOOD05162003253246 Telephone: +49 9131 84-0 Unrestricted © Siemens Healthineers, 2022 siemens-healthineers.com

  • atelica
  • attellica
  • attelica