Siemens Healthineers Academy

Respiratory Gating: editing syncs on the SOMATOM go.

This step-by-step outlines how to edit syncs for respiratory gating on the SOMATOM go.Sim and go.Open Pro.

Respiratory Gating: Editing syncs on the SOMATOM go. SOMATOM go.Sim, go.Open Pro (VA40) Note: Editing of the 4D wave on the SOMATOM go. systems is ONLY available when the scan is acquired in the Spiral Mode. edit, 4d SOMATOM go Open Pro play "5/30/1973, 50Y Symgo CT VASOA Recon Ran 5/30/2023 Topogram 1:32.13.92 PM 1 IMA 1 TOP 101 LEN 2190 TP -750.0 Respiratory Mo 10cm mA 80 T1 3 32 A 512.0 00 wirou stor can Favorites General Scan Dose Timing Config Physio Scan Contrast Scan/Recon Patient Type Organ Characteristic Target Region Scan Mode Decision Trees Acquisition [mm] Scan Direction | Respiratory Motion Adult Respiratory Chest RespiratorySpiralAdultOnline 64 x 0.60 Head to Feet L 3.35 35.65 is If the sync points are not ideal on the respiratory gating breath wave, they can be manually edited to help improve the data reconstruction. Functions include: Move, Delete, Insert, Disable, and Reset. 1. Select the desired amplitude or phase reconstruction to edit. Note: the demonstration uses phase reconstruction. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 07/10/2023 | HOOD05162003362597 2. On the right side of the respiratory gating breath wave, there is a pencil icon. Select it and the editing window will open. T1 3 32 GTO.O SL 4.0/64x0.6/p0.07 512 0 0/0 Simulator Filter Sn 600.0 010 400 Simulator 16 12 10 12 rpm Min: 8 Max: 16 4C L 3.35 60.65 3. There are 5 editing choices: Move, Delete, Insert, Disable, and Reset. Delete 10 an 12 rpm Min: 8 Max: 16 O L 3.3s 50.6s O 4. To use the move function, left mouse click, and hold while dragging the dot to the desired location and then release the mouse button. The reconstruction bars will realign to match the new sync position. Move Delete Insert Disable Reset 13 8 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 07/10/2023 | HOOD05162003362597 Healthineers Page 2 of 4 5. Select the Delete icon and right-mouse-click on the sync to be deleted. Move Delete Insert Disable Reset 12 19 O 22 8 6. Select the Insert icon if a sync is missing. Left mouse click to place the sync. To move the dot go back to Step 4. Move Delete Insert Disable Reset 12 25 7. Respiratory syncs can be disabled when the breathing pattern is not as regular as the surrounding pattern. For example, when a patient coughs in an area, not in a pertinent part of the scan. Select the Disable icon and select the waveform to be disabled. Move Delete Insert Disable Reset 12 10 8 8. Selecting the Reset Icon will undo any changes and revert back to the initial pattern. Move Delete Insert Disable Reset 12 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 07/10/2023 | HOOD05162003362597 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemens Shanghai Healthcare Sector Henkestr. 127 40 Liberty Blvd. Medical Equipment Ltd. 91052 Erlangen Malvern, PA 19355-9998 USA 278 Zhou Shu Road Germany Telephone: +1-888-826-9702 Shanghai 201318 Phone: +49 9131 84-0 Customer Care Telephone: P.R. China https://www.siemens-healthineers.com +1-800-888-7436 Telephone: +1 847 304 7700 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 07/10/2023 | HOOD05162003362597 Healthineers Page 4 of 4

  • resp
  • wave
  • snc