Resolving CH Dilution Probe Aspiration Errors on the Atellica® CI Analyzer Job Aid

Resolving CH Dilution Probe Aspiration Errors on the Atellica® CI Analyzer Job Aid

This job aid describes how to resolve CH dilution probe aspriation errors on the Atellica® CI Analyzer.

Resolving CH Dilution Probe Aspiration Errors on the Atellica® CI Analyzer SIEMENS Healthineers Job Aid Issue: CH Dilution Probe Aspiration Error lthineers Healthineers Atellica Solution DL-CI1 LabManage Samples Inprocess Racks Processed Racks EY Troubleshooting Description: The CH Dilution Probe had an abnormal sample aspiration. AF030671 AF050674 System DL CI-01 11:15 AM 0:46 AM Current Status Day Needs Tools AF030672 AF03067 11:14 AM 10:43 AM STATS Sample Interventions Supply Needs Worklist Assay Evaluation AF030673 AF030676 Online Help References: Troubleshooting Event Code: 11 005 95 08 11:13 AM 10:41 AM A 1 WU 2 00 AF030677 10:36 AM 1 Inprocess 0 Calibration Reagent Needs Calibration Results Orders Troubleshooting Steps: 1 Intervention Needed AF030678 0 QC 10:31 AM 1 Patient (non-STAT) L AF030679 9:31 AM 1. Check if the sample has insufficient volume or is of poor quality Maintenance QC Statistics Calibration Due Assay Status QC Scheduler AF030680 9:27 AM A. Review the Sample Intervention list to identify the appropriate sample 5 % 5 AF030681 8:46 AM Unload the appropriate sample Inprocess: CH-02 Errors QC Needs Guided Workflows B. Utilities AF030682 0 Activity Falled 3 Warnings 8:37 AM 8 Activities Due 5 AF030683 C. Inspect the sample volume and quality. If appropriate, collect a new sample 8:06 AM < 1 2 › Load STAT Rack Clear All Racks D. Reorder the test E. Reload the sample. Ensure the sample tube is seated securely in the rack PEPconnect: Reference “Checking Sample Status Workflow on the Atellica® Solution”, Creating Patient Orders Manually on the Atellica® Solution Job Aid”, and “Loading and Unloading Samples on the Atellica® Rack Handler Video” for additional instruction. * This procedure is continued on next slide 1 Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date 13 AUG 2023|HOOD05162003370098 Unrestricted © Siemens Healthineers, 2023 Resolving CH Dilution Probe Aspiration Errors on the Atellica® CI Analyzer SIEMENS Healthineers Job Aid 2. Check if the CH dilution probe needs cleaning or replacing, or the 3 probe wash station needs cleaning A. Perform the maintenance activity to inspect and clean the specified probe and the probe wash station PEPconnect: Reference “Inspecting and Cleaning the CH Probes, Probe Wash B. Stations and Mixer Impellers on the Atellica® CI Analyzer Video” for wash station. additional instruction. 2 3. If the problem persists, contact the local technical support provider for assistance 4 14:18 19 11 2 Effective Date 13 AUG 2023|HOOD05162003370098 Unrestricted © Siemens Healthineers, 2023 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Effective Date 13 AUG 2023|HOOD05162003370098 3 Unrestricted © Siemens Healthineers, 2023

  • attelica
  • attelica
  • atelica