Resolving Cal-QC Thermals Out of Temperature Control on the Atellica® Sample Handler Job Aid
This job aid describes how to resolve the Cal-QC thermal error, temperature out of control, on the on the Atellica® Sample Handler.
Atellica® Sample Handler: Resolving Common Errors SIEMENS Healthineers Cal- QC Thermals: Out of Temperature Control Job Aid Issue: Cal- QC Thermals: Out of Temperature Control Description: Event error codes present when Cal- QC storage is out of temperature control and thermals may need to be reset. Online Help Reference: Resetting SH Thermals in Operator Diagnostics Troubleshooting > Operator Diagnostics 8 SH1-SCI1 LabManager Troubleshooting Steps: SH-01 Module State : Diagnostics 1. Enter Diagnostics State in SH Operator Diagnostics 5 Subsystems Diagnostic Name Description A. Navigate to Troubleshooting > Operator Diagnostics All 4 Reset Thermals Disable and then enable the Cal-QC tube storage area temperature control. Perform 3 Thermals Enable the Cal-QC tube storage area Enable the Cal-QC tube storage area temperature control. Start transporting samples to and from the Cal-QC tube storage area. View Status Cancel B. Select the appropriate SH module Covers C. Select Enter Diagnostics > Yes (wait for SH to enter diagnostic state) 2. In Select a Module; select the appropriate SH 3. Select Subsystems > Thermals 4. Select Reset Thermals 5. Select Perform > Yes 7 6. Wait for the activity to complete Exit Diagnostics 7. Select Exit > Diagnostics > Yes 8. Resume the SH by selecting in the system status area 1 Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date 08 June 2023| HOOD05162003355898 Unrestricted © Siemens Healthineers, 2023 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 2 91052 Erlangen, Germany Effective Date 08 June 2023| HOOD05162003355898 Telephone: +49 9131 84-0 Unrestricted © Siemens Healthineers, 2023 siemens-healthineers.com
- Atellica
- Attellica
- Atellica