Replacing the Sample Probe Tip on the Dimension® Family of Integrated Chemistry Systems Video
The sample probe tip on the Dimension® Family of Integrated Chemistry Systems is a customer replaceable part. This video provides instructions on how to replace the sample probe tip.
Welcome to the Replacing the Sample Probe Tip on the Dimension Family of Integrated Chemistry Systems video. In this video you will learn how to replace the sample probe tip on the dimension EXL with LM and Dimension EXL 200 integrated chemistry systems, Dimension RXL Max integrated chemistry system, and the Dimension Expand and Expand Plus integrated chemistry systems. Replace the sample probe tip using the five sixteenths and 1/4 wrenches or ratchet and offset wrenches. For this procedure we will use the five sixteenths open end wrench and 1/4 offset wrench to change a sample probe tip. Place the system in standby mode, then select the pause key to turn the sampler system off. Raise the IMT and reagent lids. The sample probe is a biohazard. Follow laboratory safe protection biohazard procedures when performing maintenance and troubleshooting procedures. Lift and move the sample probe out of and away from the sample drain. The probe can be moved by the instrument by selecting F4 system prep and then F8 daily maintenance. Remove the probe tip and nut using the five sixteenths open end wrench With the offset wrench, place the five sixteenths wrench on the sample probe body to stabilize it and prevent it from turning. Position the offset wrench on the sample probe and onto the probe tip nut. Hold the five sixteenths wrench in place and turn the offset wrench clockwise to loosen the probe tip nut. Once loose, unscrew it by hand to remove the probe tip and nut. Insert a new sample probe tip into a new probe tip nut. Next, screw the assembled sample probe tip and probe tip nut onto the sample probe body finger tight. Completely tighten the new sample probe tip using the five sixteenths open end wrench and the offset wrench to use the offset wrench to tighten the probe tip first Place the five sixteenths wrench on the sample probe body to keep it from turning. Slide the 1/4 opening of the offset wrench onto the probe tip nut. Turn the offset wrench counterclockwise to completely tighten the probe tip and nut to the probe body. close the sample and reagent lids. Select Pause to restart the sampling system. From the operating menu, select F4 System Prep, then select F6 system counters. Move the cursor box to the Sample Probe Tip field and select Enter to change the field from No to Yes. Select F1 Store Changes To store the updates. Select Yes in the dialog box. Next you will need to prime the Sample pump from the operating menu. Select F4 System Prep, then select F7 Pump Prime. Enter three in the Cycles field for the number of cycles to be performed. Select F2 Sampler to begin priming the sample pump. Next, be sure to perform the Sample probe alignments according to the procedures in the Operators Guide. Perform daily QC and record completion of this procedure in the Daily Maintenance Log screens. If documenting using the paper logs from the Dimension System Operators Guide, document the maintenance in the weekly slash, monthly maintenance log sheet or instrument log sheet. Or if documenting using the electronic logs in the Dimension System Software, document the maintenance in the instrument log screen.
1835 13 20000 133 12000 379 48000 36000 Replacing the Sample Probe Tip on the Dimension® Family of Integrated Chemistry Systems Video SIEMENS Standby Sampler Idle IMT OK 01/31/22 10:52 Healthineers Dimension Exit labmanager Enter en OPERATING MENU STAT Status PLEASE SELECT AN OPTION USING THE FUNCTION KEYS: Sample Alert Supplies At any time, press HELP to get help, or press EXIT to exit a program. QC Alert Calib Alert To Shut down or Change Operator, press Sign Out or Alt+EXIT. Run Home F1: ENTER DATA F2: SAMPLE STATUS F3: TEST RESULTS F4: SYSTEM PREP F5: PROCESS CTRL F6: SYSTEM CONFIG F7: DIAGNOSTICS F8: SEGMENT STATUS Reset PSA FERR TRNF TPSA F1 F4 F7 ALD Caps Lock Control Tab Samplers Off 01/28/24 17:12 Dimension EXL 20 Dime Dimension EXL 200 Reagent Arm F4: SYSTEM CHECK SYSTEM PREPARATION MENU F1: INVENTORY F2: REAGENT PREP F3: IMT F5: TEMP MONITOR F6: SYS COUNTERS F7: PUMP PRIME F8: DAILY MAINT. Dim CTN PBNP Delete SIEMENS . 01/28/24 17:23 01/28/24 17:28 SYSTEM COUNTERS Installed: 5-AUG-2020 Bootups: 16 Cuvettes: 409 Tests: Dirty windows: Item Cycles Clean at Last Cleaned Sample Probe: 23-MAR-2023 20:46 Pos: Cycles Replace at Last Replaced Replace Cuvette Cartridge: 12-APR-2023 4:32 NO Diaphragm: 5-AUG-2020 11:29 Sample Probe Tip: R1 Probe Tip: 13-JUL-2023 0:05 F1: STORE CHANGES F2: DIAPH CHANGE F3: FILM LOAD F4: CLEAN PROBE F5: F7: RMS COUNTERS F8: YES Do you want to store the NEW system information? (y/n) Diagnostics PUMP PRIME CYCLES: 3 IMT SAMPLER REAGENT 1 REAGENT 2 DIL PUMP REAGENT 3 F1: PRIME WATER F2: SAMPLER F3: REAGENT 1 F4: REAGENT 2 F5: IMT DIL PUMP F6: HM ... F7: REAGENT 3 Sample pump cycling. Press (Enter) to cancel. SAMPLER ARM ALIGNMENT PRESS F1 TO START SAMPLE ARM - CUVETTE ALIGNMENT PRESS F2 TO START SAMPLE ARM - CUP ALIGNMENT PRESS F3 TO START SAMPLE ARM - DRAIN ALIGNMENT PRESS F4 TO PERFORM SAMPLE ARM - VESSEL WHEEL ALIGNMENT PRESS F6 TO SEE ALIGNMENT OFFSET PARAMETERS PRESS F7 TO START SAMPLE ARM - IMT PORT ALIGNMENT PRESS F8 TO SET SAMPLE PROBE MAX DEPTH F1: CUVT ALIGN F2: CUP ALIGN F3: DRAIN ALIGN F4: VESSEL ALIGN F6: ALIGN FILE F7: PORT ALIGN F8: PROBE/BAR CODE MAINTENANCE LOGS Year: 20XX Clean R3 Operator Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- 10457734
- Dimension
- probe
- probe tip
- sample probe
- replace sample probe
- replace sample probe tip
- dimension maintenance