Quantum Technology – Elimination of Electronic Noise Video
Follow an expert and a student as they discuss electronic noise in EIDs and the advantages of photon-counting technology. Explore the subject interactively.
Target group: Basic user, all users.
Audio: Yes.
Recommended to be viewed on the following devices: Tablet, laptop, desktop computer (sufficiently large display required).
Slide:%Project.SceneNumber%.%Scene.SlideNumber% Continue Introduction to Photo-Counting Fundamentals Quantum Technology – Elimination of Electronic Noise Follow an expert and a student as they discuss electronic noise in EIDs and the advantages of photon-counting technology. Explore the subject interactively. Master Template HILS2218 | Effective Date: 25 Mar 2022 ? Start Disclaimer Introduction EID time [ns] pulse-height [keV] Film 1 Select 2 answers. Knowledge Check 1 of 2 How do X-ray signals with less than 20 keV contribute to a CT image? ? They provide relevant information for the CT image. There are practically no photons with an energy below 20 keV that reach the detector. The EID incorporates electronic noise in the measured signal, so the image quality is degraded. The EID identifies photons with an energy below 20 keV. Knowledge Check 1 Incorrect There are practically no photons with an energy below 20 keV that reach the detector. The ElD incorporates electronic noise in the measured signal, so the image quality is degraded. Continue Correct Continue time [ns] pulse-height [keV] PCD Threshold Signal Pulses Electronic Noise Film 2 EID vs. PCD Imaging Move the slider to see the difference between an image with and without electronic noise. Energy-Integrating Detector (EID) Photon-Counting Detector (PCD) Image courtesy of University Hospital of Tübingen, Tubingen, Germany ? EID vs. PCD Imaging Select the best answer. ? Because a PCD converts the electronic noise to a usable signal. Because a PCD can’t detect electronic noise. Knowledge Check 2 of 2 Why can a PCD eliminate electronic noise? Because a PCD uses a specific filter. Because a PCD can measure the energy of each individual photon. Knowledge Check 2 Incorrect A PCD can eliminate electronic noise, because it can measure the energy of each photon individually. Correct Film 3 Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. Disclaimer ? You have completed the Quantum Technology – Elimination of Electronic Noise Video. Completion details, certificates tab Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG | Siemensstr. 3 91301 Forchheim, Germany | Phone: +49 9191 18-0 | siemens-healthineers.com ? Disclaimer Navigation Help The timeline displays the progression of the animation. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Tmeline Select the PREV or NEXT buttons to navigate to the previous or next section. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Previous / Next Navigation Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Knowledge Check Slide Question Bank 1 QR700005767 / QR700016713 | Effective Date: 27 Mar 2025 1 Introduction to Photo-Counting Fundamentals 1.1 Welcome 1.2 Electronic Noise 1.4 Elimination of Electronic Noise 1.5 Example of Photon-Counting Imaging 1.7 Outro 1.8 Completion 1.9 Disclaimer
- ct
- photon
- counting
- quantum
- technology
- eid
- pcd
- energy
- integrating
- detector
- advantage
- elimination
- electronic
- noise