Siemens Healthineers Academy

ACUSON Maple 1.0 Text, Body Markers and Arrow Presentation

Tool for describing more detailed information on how to us the text, body markers and arrow functionalities

SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Maple Ultrasound System Text, Body Marker and Arrow Software Release 1.0 1 Unrestricted © Siemens Healthineers 2023 Speaker Notes: In this presentation we will discuss the ACUSON Maple ultrasound system text, body marker and arrow functionality. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality and customization Maple 2 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Here are the objectives for this presentation. We will begin with the text functionality. Notes No. 2 SIEMENS Healthineers Accessing Text SIEMENS . Healthineers ... IHHHI 0000 O 3 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To access the Text Feature, press the Text Body Marker key on the Control Panel. Notes No. 3 SIEMENS Healthineers Text Touch Screen SIEMENS. Healthineers ... Tab menu Text Body Marker Arrow Library Exam Abd ? Config menu # RIGHT SAG LIVER AORTA SUP RUQ Keyboard LEFT TRV GB IVC MID RLQ A B CBD KIDNEY INF LUQ Clear Screen Clear Screen PANCREAS BLADDER PROX LLQ Hide Patient SPLEEN FLUID DIST LLD Image Param PORTAL VEIN CAUDATE LOBE C D Hide Text Off Text functions Home Set Home Font Size Delete Word Delete Line Cine 82 4 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once text is activated, the Touch Screen will display the text features. • Tab Menu: This allows the user to cycle between Text, Body Marker or the Arrow feature • Config Menu: Press the Configuration icon to access the configuration menu to customize the display of the text on the Touch Screen • Keyboard: Press the keyboard icon to activate the digital keyboard for manual typing of text • Clear Screen: Press to delete all Text, Body Markers and Arrows displayed on the Screen Text Functions: • Hide Text: Hides or displays all text on the image screen • Font Size: Changes the size of the text font • Home Position: Moves text cursor to the set home position • Set Home: Sets the desired location for text to appear on the image screen • Delete Word: Deletes the last word typed or selected from the Touch Screen • Delete Line: Deletes the active text in a single line • Cine: Allows the user to use the Cine function while in the text menu There are multiple types of text available (A - D and a Library). Each section is pre-set by the factory, although they can be customized to the user preference. Please note that only one word can be selected per type of text in a single consecutive line. Notes No. 4 SIEMENS Healthineers Text exam package SIEMENS . Healthineers ... Text Body Marker Arrow Exam Abd ? Abd Abd-Difficult OB Early OB GYN RIGHT SAG MSK Breast Thyroid Testis Adult Echo LEFT TRV Arterial Carotid Venous Renal Fetal Echo Ped Abd Ped Echo Penile Neo Head TCD Clear Screen Digital Neo Echo Pelvic Floor Bowel FAST Hide Patient Lung Ped Hip Pelvis Prostate Spine Image Param Nerve 10 Abd DB (Adv) TEE Hide Text Off Home Set Home Delete Word Delete Line 5 Unrestricted © Siemens Healthineers 2023 Speaker Notes: If you want to access text from another exam type during an exam, press Exam on the Touch Screen. The list of exam types available is displayed. Select the exam type to access the stored text and measurements for that exam type. Notes No. 5 SIEMENS Healthineers Using the Text feature SIEMENS . Healthineers ... A Text Body Marker Arrow Exam Abd ? RIGHT TRV GB 118 0.3 RIGHT SAG LIVER AORTA SUP RUQ ASC 2 DICE Med TRV GB Dyn R 65 dal THI 3.6 MHZ LEFT TRV GB IVC MID RLO 26 fps CBD KIDNEY INF LUQ Screen PANCREAS BLADDER PROX Patient SPLEEN FLUID DIST LLD Image Param PORTAL VEIN CAUDATE LOBE End Exam 12 on Hide Text Off Home Set Home Cine Font Size Delete Word Delete Line 138 6 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once the Text feature is activated, the Touch Screen displays the pre-defined text. Press the desired text and note that it will change to white and is displayed on the Image Screen. To move the text, place the cursor in the text and double-click the Set key. The line of text becomes green and can be moved around on the Image Screen. The font size ranges from 14-22. If the user changes the font size, the system will remain at that size, even after rebooting the system. To change text, press a different selection and it will replace the existing text. Only one word from each type can be selected in a consecutive line of text. To insert annotation text on an image using auto complete, position the cursor on the Image Screen and then enter the text. The system displays pre-defined text matching the entered characters, if specified in the configuration settings. When the entered text matches pre- defined text, the text is highlighted in green. To accept the pre-defined text, press enter on the keyboard. Please note: If the cursor is repositioned before accepting the pre-defined text, the system displays only the characters that were entered. Notes No. 6 SIEMENS Healthineers Entering manual text SIEMENS. Healthineers ... Text Body Marker Arrow Exam Abd 2 RIGHT TRV GB RIGHT SAG LIVER AORTA SUP RUQ LEFT TRV GB IVC MID RLQ CBD KIDNEY INF LUQ Clear Screen Screen PANCREAS BLADDER PROX LLQ Hide Patient SPLEEN FLUID DIST LLD Param PORTAL VEIN CAUDATE LOBE End Exam Hide Text Off Home Set Home Delete Word Delete Line Cine Font Size 138 7 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To manually enter text using the digital keyboard, press the Text Body Marker key, then select the keyboard icon on the left side of the Touch Screen. Use the cursor and Set key to choose a letter or press the letter on the Touch Screen virtual keyboard. When Caps Lock is on, it is blue in color. When Caps Lock is off, the key is gray. The default is Caps Lock off. Notes No. 7 SIEMENS Healthineers Entering text with optional pull-out keyboard SIEMENS . Healthineers ... F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F 14 F15 F16 F17 @ 3 $ € % & V 2 4 5 16 7 8 W # O N Q W E R T Y U O P - 6 ú ae A S D F G H C < A > Z X C V B N v Insert - - Ctrl END Alt Alt V 5kg MAX 1 lbs MAX 8 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The system has an optional pull-out keyboard. Press the Text Body Marker key on the Control Panel to activate the Text feature, then roll trackball and place the cursor in desired area in the image and begin typing. Text A and B can be selected by pressing Text A or Text B. Continue pressing though each text key to display the next word in the text list on the Image Screen. The key with the arrow down picture is the Caps Lock key. Notes No. 8 SIEMENS Healthineers Correcting text in review mode SIEMENS . Healthineers ... C5-2V Abd Tx Power 98% MI 1.49 TIS 0.4 TIB 0.4 ASC 3 DICE High Dyn R 65 dB THI 5.0 MHZ 0 dB 25 fps 13 cm LIVER KINEXX KIDNEY 1 194 9 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To change text on a stored image during an active study or a closed study, press Review on the Control Panel and select the image to change. The text will not overwrite. However, you can X out the incorrect text and add new text. Notes No. 9 SIEMENS Healthineers Text configuration SIEMENS . Healthineers ... GYN ? GYN MSK Breast Thyroid Testis Clear Adult Echo Screen TEST Hide Configuration Arterial Patient Carotid General 1 General 2 Display Custom Key Soft Keys Exam Image Param Venous Measureme Text Annotation Body Market Stress Echo estescan Cip Store Renal Printer Barcode Wireless Network Ubilay Archive Fetal Echo Security Service Ped Abd Close 10 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To configure the Text on the Touch Screen, press the Configuration icon on the Touch Screen. The Image Screen will now display the menu. Scroll down to Text Annotation on the Image Screen or select the Text Annotation icon on the Touch Screen. The active exam text will be displayed. The user can then select the exam they wish to edit from the drop-down menu. Notes No. 10 SIEMENS Healthineers Text configuration SIEMENS . Healthineers ... Text Annotation Text Annotation Exam Abd Exam Abd Text A Scar Available Text C Available Text A LUC LLO LLD SAG TRV Sup Mid Monday Prox Midity Dist Caudate Lobe *Scar Restore Defaults Report Detoutes 11 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To configure the text on the Touch Screen, select the specific text you wish to edit as shown in the first screen. To insert text, enter new text in the text box or select pre-defined text in the list of available text and click the right arrow to move it to the current text list. To edit text in the selected annotations, select the text from the selected text field. Edit the text in the text box and select Modify. Once a new text is added, it displays with an asterisk as shown in screen three. To remove text from the annotation library or a modifier library, select the text in the list of selected annotations or modifiers. Next, select the left arrow as shown on screen two to hide the word. To change the sequence of annotations, select the text in the list of selected annotations. To reposition the text upward, select the up arrow. To reposition the text downward, select the down arrow. Pressing Restore Defaults deletes the user-defined settings and restores the factory default settings. Notes No. 11 SIEMENS Healthineers Enable Auto Complete SIEMENS. Healthineers ... Configuration System Configuration Text Annotation General 1 ? Exam Abd General 1 General 2 Custom Keys Soft Keys General 2 Display Exam Display Text A Library Custom Keys Measurement Text Annotation Body Marker Stress Echo eSieScan Clip Store VI Enable Auto Complete Soft Keys Available Annotations Selected Annotations Exam Printer Barcode Wireless Network Utility Archive Lett Measurement Text Annotation Security Service Body Marker 66868 Stress Echo CHO eSieScan Pancreas scheen Clip Store Portal Vein Close Printer Aorta MC Wireless Kidney Bladder Fluid Caudate Lobe Archive Sup Service Restore Defaults 12 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once in the Configuration Menu, the user can also Enable Auto Complete text. Select Text Annotation and check Enable Auto Complete in the library section. To use the auto complete function: 1. Position the cursor on the image screen and then enter the text. The system displays pre- defined text matching the entered characters if specified in the configuration settings. When the entered text matches predefined text, the text is highlighted in green. 2. To accept the pre-defined text, press enter or tab on the keyboard. Please note: If you reposition the cursor before accepting the pre-defined text, the system displays only the characters you entered. Notes No. 12 SIEMENS Healthineers Other Text configuration SIEMENS . Healthineers ... System Configuration General 2 General 1 Patient Annotation General 2 Store Patient Screen on Registration Delete Body Marker on Unfreeze Display Hide Patient Banner Delete Text on Unfreeze Custom Keys Patient Data Age Date of Birth Arrow Type Soft Keys Patient Registration Long Form Exam Measurement End Exam Behavior Activate the 2D Imaging mode Register a patient or search from Worklist Arrow Size Text Annotation Large Body Marker Physician or Operator row Color oreen Stress Echo Performing Freysicion eSieScan Ada mage Store Contrast Store Image with Calper Clip Store Printer 5-Video Format PAL Barcode . NISC Wireless Close 13 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once in the Configuration menu, the user can also customize the text feature. Select General 2. The user can choose to check the box for Delete Text on Unfreeze here. The default is unchecked. Notes No. 13 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality and customization Maple 14 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss the body marker functionality. Notes No. 14 SIEMENS Healthineers Accessing Body Marker SIEMENS. Healthineers ... Text Body Marker Arrow Exam Abd ? Clear Screen Y Hide Patient Image Param End Exam Marker Size Home Set Home Delete Trackball Transducer Marker 15 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To access the Body Marker feature, press the Text Body Marker key on the Control Panel. Select the Body Marker tab. The system defaults to the last field chosen. Notes No. 15 SIEMENS Healthineers Selecting Body Markers SIEMENS . Healthineers ... Exam GYN A Text dy Marke Arrow Ix Power 100% MI 0.97 1 0.2 ? ASC 2 DITCE Med Dyn R 75 cl Patient Y End Exart Marker Siz Home Set Home Delete Trackball Transducer Marker Position Position Marker Size Home Set Home Delete Trackball Rotate Rotate Body Marker 16 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once you have pressed the Text Body Marker key, select the Body Marker tab. The body marker default will be the upper left selection for that preset and the transducer marker will be active displaying position and rotate. To add a Body Marker from another application, select Exam in the upper right corner of the Touch Screen, select the desired exam and make your selection on the Touch Screen. To move the Transducer Marker, roll the trackball or use the Touch Screen to drag the transducer marker. To rotate the Transducer Marker, there are three workflows to choose from: 1. On the Touch Screen, drag the blue dot to indicate the direction of the Transducer Marker 2. Press the Set key to change the trackball function to rotate 3. Rotate the Angle knob on the control panel The system adjusts the angle of the transducer marker in 15° increments. To change the angle in 90° increments, press the Angle knob on the control panel. To move the Body Marker anywhere on the imaging screen, push the rotary soft key to Body Maker and the Body Marker will be outlined with a green box, indicating that the body marker is active to move. Use the trackball to move the Body Marker to the desired location. Push the rotary knob again to set the body marker position. To change the Body Marker selection, either select a new body marker from the Touch Screen or rotate the Select knob on the Control Panel. • Marker Size will change the body marker size. There are 20 different sizes. The default size will be the middle size; if the user changes the size, the system will return to the last used setting size. • Home will set the home position of the body marker • Set Home will allow the user to configure the home position • Delete will delete the body marker • Trackball Transducer Marker will allow both trackball and set keys to toggle between position and rotation of the transducer marker To remove all Text, Arrows and Body Markers from the Image Screen, select Clear Screen on the left side of the Touch Screen. Notes No. 16 SIEMENS Healthineers To exit the Body Marker function, press the Text Body Marker key on the Control Panel. Notes No. 16 SIEMENS Healthineers Body Marker configuration SIEMENS. Healthineers ... Configuration System Configuration Body Marker Geteilt ? General 1 General 2 Display Custom Keys Soft Keys Exam Measurement Text Annotation Body Marke Stress Echo eSieScan Clip Store # Printer Barcode Wireless Network Utility Archive Test Annotation screen Security Service Cip Storm . . Close 17 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To configure the Body Marker on the Touch Screen, press the System Configuration icon on the Touch Screen. The Image Screen will display the menu. Scroll down to Body Marker on the Image Screen or select the Body Marker on the Touch Screen. The active exam Body Markers are displayed. The user can select the exam they wish to edit from the drop-down menu as is done with Text Annotation. All available Body Markers from all exams are stored in the menu on the left. To add, select the desired Body Marker and select the right arrow to add. It will appear in blue as the first displayed Body Marker on the Touch Screen and Configuration Screen. Using the up/down arrows, the user can place the Body Marker in the desired position. The Body Markers are displayed on the Touch Screen as shown in the Configuration Menu. To remove a Body Marker, select the desired Body Marker and press the left arrow to return to the library. Restore Defaults deletes the user-defined settings and restores the factory default settings for the Body Markers. Notes No. 17 SIEMENS Healthineers Other Body Marker configuration SIEMENS. Healthineers ... System Configuration A Configuration ? General General 2 Display Custom Keys Soft Keys Exam Soft Keys Measurement Text Annotation Body Marker Stress Echo eSieScan Clip Store # Printer Barcode Wireless Network Utility Archive Security Service ONK Close 18 18 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once in the Configuration menu, the user can also customize a few other Body Marker features. Select General 2 to choose to Delete Body Marker on Unfreeze. The default position is unchecked. Notes No. 18 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality and customization Maple 19 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss the arrow functionality and customization. Notes No. 19 SIEMENS Healthineers Accessing Arrow feature SIEMENS . Healthineers ... A Text Body Marker Arrow ? Clear Screen Hide Patient Image Param Arrow Color Arrow Size Delete Rotate Cine Green Large 82 20 ] Unrestricted © Siemens Healthineers 2023 Speaker Notes: To access the Arrow feature, press the Text Body Marker key on the Control Panel. Select the Arrow tab. The system defaults to the last field chosen. Notes No. 20 SIEMENS Healthineers Accessing Arrow feature SIEMENS . Healthineers ... A Text Body Marker Arrow ? KK Clear Screen Might TRV GB Hide Patient Image Param Arrow Color Arrow Size Green Delete Rotate Cine Large 82 21 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once you have pressed the Text Body Marker key, select the Arrow tab to view the Arrow features. The configuration of the Arrow feature default is under Configuration > General 2. • The system displays the arrow in green • Customize an arrow for type, color and size on the Touch Screen • To change the angle of the arrow, drag the blue dot on the Touch Screen to indicate the direction of the arrow or press the Rotate rotary knob and the system adjusts the angle of the arrow in 30° increments. Rotate the Rotate rotary knob to move the arrow in 1° increments To insert an arrow, position the cursor on the image screen, press the Text Body Marker key, select the Arrow tab and press the Set key. To delete arrows, select the arrow, then select Delete on the Touch Screen. To remove all Text, Arrows and Body Markers from the Image Screen, select Clear Screen from the menu on the left side of the Touch Screen. To use the cine function in the arrow menu, rotate the Cine rotary knob. To exit the arrow annotation function, press Text Body Marker key on the Control Panel. Notes No. 21 SIEMENS Healthineers Arrow feature configuration SIEMENS . Healthineers ... Configuration ? General 1 General 2 Display Custom Keys Soft Keys Exam Measurement ext Annotation Body Marke Stress Echo eSieScan Clip Store Printer Barcode Wireless Network Utility Archive Security Service Close 22 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once in the Configuration Menu, the user can customize the default for the Arrow feature. Select General 2 and select the desired Arrow type. Using the drop-down menu, select the default color (yellow, orange or green) and size (small, medium and large). This is applied across all Exam types. Notes No. 22 SIEMENS Healthineers SIEMENS . Trademarks and Disclaimers Healthineers ... ACUSON Maple is a trademark of Siemens Medical Solutions USA, Inc. 23 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No Speaker Notes. Notes No. 23 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS . Healthineers ... Questions? 24 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No Speaker Notes. Notes No. 24

  • ACUSON
  • Maple
  • NX Family
  • Sales
  • Training
  • Ultrasound
  • Doppler
  • Multispecialty
  • General Imaging
  • Cardiac
  • Vascular
  • OB
  • Obstetrics
  • Gynecology
  • 4D
  • 3D
  • 2D
  • Radiology
  • Cardiology
  • Echocardiography
  • TEE
  • Text
  • Body Markers
  • Arrow