Siemens Healthineers Academy

ACUSON Maple 1.0 System Overview Presentation

This tool contains detail about the Maple ultrasound system.

SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Maple Ultrasound System System Overview 1.0 Software Release 1 Unrestricted © Siemens Healthineers 2023 Speaker Notes: In this presentation we will discuss the system overview of the ACUSON Maple™ ultrasound system. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Review external features • Explain Control Panel and Touch Screen • Discuss transducers and care of the system 2 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Here are the objectives. We will start with reviewing the external features of the system. Notes No. 2 SIEMENS Healthineers System overview SIEMENS . Healthineers ... 21.5" LED display Storage Bins (both sides) 13.3” Touch Screen Adjustable Six transducer holders Control Panel Four transducer ports plus 1 CW port System weight: Easy wheeling castors 144 pounds (65 kilograms) Battery (optional) 3 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The ACUSON Maple ultrasound system weighs 167.5 pounds (76 kilograms) and includes the following features: • 21.5” LED display • 13.3” Touch Screen • Adjustable Control Panel • Five transducer ports (four standard and one pencil port) • Easy wheeling castors • Generous storage Notes No. 3 SIEMENS Healthineers Monitor SIEMENS . Healthineers ... Enhanced 21.5” LED LCD Easy monitor adjustment with with lower black levels palm curve on front and grip on back Three step task light Monitor brightness control brightness adjustment 4 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The ACUSON Maple system showcases a 21.5” LED LCD monitor which features: • Lower black levels • Easy monitor adjustment location with posterior grips • Task light with 3 levels of brightness • Easy monitor custom setting Notes No. 4 SIEMENS Healthineers Touch Screen SIEMENS . Healthineers ... Customizable 13.3” ACUSON Maple® Touch Screen Touch Screen brightness control Two USB ports 5 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The customizable 13.3” Touch Screen has two USB ports that are located on the left side of the Touch Screen. The Touch Screen brightness controls are located on the right. Notes No. 5 SIEMENS Healthineers Gel warmer, speakers, transducer holders and storage bins SIEMENS . Healthineers ... Gel Warmer • Optional • Adjustable temperature • Configurable • Optional large gel bottle holder Speakers • High-quality speakers • Left and right of Touch Screen Transducer Holders • Six holders – 4 short and 2 long • Configurable SIEMENS • Easy to clean Storage Bins • Two optional storage bins 6 Unrestricted © Siemens Healthineers 2023 Speaker Notes: High-quality speakers are located on both the left and right of the Touch Screen. The standard gel warmer is configurable in location and includes adjustable temperature controls. A large gel bottle holder is also available (optional). The system includes 6 transducer holders (4 short and 2 long) which are configurable and easy to clean. Notes No. 6 SIEMENS Healthineers Peripherals (optional) SIEMENS . Healthineers ... • BW printer - SONY UP-D898DC • Color printer - UPD25MD-FW3.0 • DVD - Hitachi-LG GUD0N • Physio - Common Physio Module (CF Version) B/W Printer DVD Player Physio Module Color printer 7 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The following optional peripheral devices are available on the ACUSON Maple system: • B/W printer • Color printer • DVD • Physio Notes No. 7 SIEMENS Healthineers Foot switch (optional) SIEMENS. Healthineers ... • Ideal for interventional cases • Dual configurable functions FSU-2000 0 • USB connection 8 Unrestricted © Siemens Healthineers 2023 Speaker Notes: A foot switch with two pedals for dual configurable functionalities is available as an option. The foot switch connects to the system via USB. To configure the foot switch, select System Configuration > Custom Keys > Key Function. Select from the list of custom assignments available for the Right Pedal and Left Pedal. Notes No. 8 SIEMENS Healthineers Storage SIEMENS. Healthineers ... Side storage bins Behind Touch Screen 9 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The ACUSON Maple system features generous storage capabilities including: • Two optional side storage bins • Storage behind the Touch Screen Notes No. 9 SIEMENS Healthineers Articulation SIEMENS . Healthineers ... -15° +70° -30° +30° 110mm Monitor Control Panel height adjustment adjustment 10 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The system contains articulating components which enables the adjustment of: • Control Panel height adjustment of 110 mm • Monitor adjustment of 70° forward and 15° backwards • Monitor arm adjustment of 30° forward and backwards Notes No. 10 SIEMENS Healthineers Transducer ports SIEMENS . Healthineers ... Five transducer ports • Four standard transducer ports • One transducer port for continuous wave (pencil) transducers 11 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The ACUSON Maple system features five transducer ports. Four standard ports and one CW pencil port reducing the need to change transducers when changing exam types. Notes No. 11 SIEMENS Healthineers Cable management SIEMENS . Healthineers ... Flexible cable management • Two cable hangers located on Control Panel • One cable hanger located on the back for the power cord SIEMENS Healthincers 0000 12 Unrestricted © Siemens Healthineers 2023 Speaker Notes: With the increased number of transducer ports available on the system, cable management is important. The ACUSON Maple system showcases a flexible cable management system which includes two cable hangers located under the Control Panel and one cable hanger on the back of the system for the power cord. Notes No. 12 SIEMENS Healthineers Connecting the transducers SIEMENS . Healthineers ... 1. Ensure lever lock is in left, unlocked position 2. Align connector and press into transducer port 3. Place lever into right into a locked position 3 ......... 6 Unlocked Locked 13 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To connect a transducer: 1. Ensure the lever lock is in the left, unlocked position 2. Align the connector and press into the transducer port 3. Place the lever into the right into a locked position To disconnect a transducer: 1. Place the lever into the left into an unlocked position 2. Remove the transducer connector Notes No. 13 SIEMENS Healthineers Side of system SIEMENS . Healthineers ... .... USB connections .. E CE Input connections Main power supply 14 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The following components are located on the back of the system: • Main power supply • Power cord hanger • Input connections Notes No. 14 SIEMENS Healthineers System casters SIEMENS . Healthineers ... 15 Unrestricted © Siemens Healthineers 2023 Speaker Notes: There are four easy-wheeling casters with locking mechanisms on the front set. Notes No. 15 SIEMENS Healthineers Control Panel protective overlay (optional) SIEMENS . Healthineers ... A protective overlay system is available for the system Control Panel • Large overlay for Control Panel • Smaller overlays for individual controls • Disposable 16 Unrestricted © Siemens Healthineers 2023 Speaker Notes: A disposable (optional) protective overlay is available for the system Control Panel. Options include both a large overlay and smaller overlays for individual controls. Notes No. 16 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Review external features • Explain Control Panel and Touch Screen • Discuss transducers and care of the system 17 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss the Control Panel and Touch Screen. Notes No. 17 SIEMENS Healthineers Power on/off, QuikStart standby mode and battery SIEMENS . Healthineers ... System Shutdown How do you want to proceed? Shutdown Restart Standby Cancel Power on/off QuikStart standby mode Battery (optional) – under front of system 18 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The “Power” button is located on the Control Panel, to the left of the Touch Screen. A QuikStart standby mode is available. This feature: • Powers up in less than 2 seconds and shuts down in ~4 seconds • Press Power and then Standby to enter • Scanning requires a power source connection The optional battery is located under the front of the system. Notes No. 18 SIEMENS Healthineers Battery support SIEMENS. Healthineers' ... • Battery support indicator AC power is Plugged in Remaining battery: 36% EE 19 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The battery indicator is displayed on the upper right portion of the monitor. Notes No. 19 SIEMENS Healthineers Battery indicators SIEMENS . Healthineers ... Battery indicators will show the current battery status, and if the system is plugged in or not with a plug icon System is Unplugged O Full WII High [I] Mid [} LOW Critical Low Run Down 100% 92% 65% 30% 15% 0% System is Plugged in " Full "I High "m] Mid IL LOW Critical Low "] Run Down 100% 92% 65% 30% 15% 0% 20 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The Battery indicator will be displayed so the user can recognize the current battery status. The display will indicate the battery level and whether the system is plugged in or not. Notes No. 20 SIEMENS Healthineers Battery Standby and Restart SIEMENS . Healthineers ... Standby: In Battery mode, Standby is allowed depending on the battery capacity @ Full a High I Mid LOW Critical Low Standby x] Standby When the battery level is Mid or above Mid, When the battery level is Low or Critical Low, it's possible to run the Standby mode the system will not allow the Standby mode. In this case, click the Standby button and an information dialog will be provided, "The battery is low to support standby." Restart: Restart is not allowed when system is unplugged O Full a High [] Mid @ LOW D Critical Low x Restart Restart is only allowed once AC power is connected to the system. Therefore, click the Restart button, and an information dialog will be provided, "Connect the AC power and then restart the system." 21 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The standby feature is only permitted when the battery level is Mid or above. If the battery is low or critical low, then Standby will not be permitted, and a message will appear that the battery is too low to support. Restarting the system is only permitted once the AC power is connected to the system. Notes No. 21 SIEMENS Healthineers Control Panel SIEMENS . Healthineers ... Major Modes Soft Keys Workflow controls DCG controls Doppler controls Depth/Focus Depth / Foon @ Three User-Defined Dual/Zoom 10.000 controls Text and Body Marker O Caliper, Print and Caliper Clip Store O Select Print Store 2 Pointer Freeze Key 22 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The Control Panel controls are displayed and labeled here. Notes No. 22 SIEMENS Healthineers Keyboard SIEMENS . Healthineers ... A Patient Browser Review ? + New Patient Edit Patient Last Name First Name OK Cancel Patient ID X 6 0 x Tab W t y u O P Caps Lock a d f g h Enter Shift C V b n m T Del Ctrl Alt English INS Alt Virtual keyboard Pull-out keyboard (optional) 23 Unrestricted © Siemens Healthineers 2023 Speaker Notes: A virtual alphanumeric keyboard is located on the Touch Screen. A pull-out keyboard is also available (optional). Notes No. 23 SIEMENS Healthineers Language and special character key SIEMENS. Healthineers ... Patient Browser Patient Browser Review New Patient n / Edit Patient ? n + New Patient / Edit Patient Last Name First Name OK Cancel Patient ID X @ % A 5 RO 16 18 9 W O Tab a Tab W e TO It y u i p o Caps Lock é Caps Lock S d f g h k Enter Shift e Shift Z X C V b n m Del Ctrl Alt Special INS Ctrl Alt English INS Alt › 24 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The language key is located on the digital keyboard and gives the user access to special characters as desired. Notes No. 24 SIEMENS Healthineers Screen saver SIEMENS . Healthineers ... ACUSON Maple 25 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The system supports a screen saver feature with images of a Maple tree displayed in multiple environments over the course of a day. This represents the versatility and adaptability of the system to many different scanning environments and clinical uses throughout the day. To set the timing of the screen saver, select the System Configuration icon on the Touch Screen, then select Display. Notes No. 25 SIEMENS Healthineers Image Screen SIEMENS . Healthineers .. Patient SIEMENS Banner 12345678 WR. RADIOLOGIST, SONOGRA ... 59Years F ACUSON 27/06/2023 13:35:07 16L4 Carotid Tx Power 100% Thumbnails Imaging MI 0.75 TIS 0.2 TIB 1.4 Parameters 5.3 MHZ 3906 Hz Gate 2.0 mm -2 dB 36 fps Thumbnail User-Defined key controls assignments Home Base 26 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The Patient Banner displays the patient information. The hospital name can be entered in the System Configuration menu under General 1. The user can hide the patient information by selecting Hide Patient on the left side of the Touch Screen. The patient information can be redisplayed by selecting Hide Patient again. The imaging parameters are displayed for each mode. The user can hide the imaging parameters by selecting Imaging Parameters on the left side of the Touch Screen. Select Imaging Parameters again to restore. The assignments for the user-defined (UD) keys are displayed on the bottom left of the imaging screen. They can be programmed in the System Configuration Menu > Custom Keys. The trackball controls are mode-dependent and are displayed at the bottom of the Touch Screen. The thumbnail images are displayed along the right side of the image. The controls to print, delete and clear thumbnail images are located on the bottom right. Notes No. 26 SIEMENS Healthineers Image size SIEMENS . Healthineers ... SIEMENS 1314 Carotid Tx Power 100% MI 0.60 TIS 0.2 TIB 0.2 ASC 2 DTCE Med Image Size 2 Dyn R 60 dB THI 10.0 MHZ 0 dB 49 fps Focus Width House 27 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The system allows the user to choose the desired image size displayed on the monitor. The ACUSON Maple ultrasound system has 5 available image sizes, which are easily selected by using the rotary soft key located at the base of the Touch Screen. Notes No. 27 SIEMENS Healthineers Extensive View SIEMENS. Healthineers' .. L10-55 Normal View Extensive View Full View • Captures patient information • Does not capture Patient and banner information and Banner • Hides thumbnails • Hides thumbnails • Hides trackball legend • Hides trackball legend 28 28 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The user has 3 options for the size of the image display: • The normal view will capture the patient information, patient banner, thumbnails and the trackball legend • The Extensive view will capture the patient information and the patient banner, although it hides the thumbnails and the trackball legend • The Full View will display the largest diagnostic image on the monitor and will not capture the patient information or the patient banner and will also hide the thumbnails and the trackball legend Notes No. 28 SIEMENS Healthineers Extensive View SIEMENS . Healthineers ... 7C2 16L4 Abd + Add Exam Workflow 2D Contrast Elasticity SieScape eSieScan Clarify VE Persist Full Screen Extensive View Clarify VE Levels Edge UR Flip UID Fli Clear Screen THI Biopsy Line Biopsy Hide Patient Physio Settings > 4B Split Image Param Clip Settings Full FOV End Exam High Density DTCE Med R/S 3 Tint 12 Focus Width TEQ Gain 0 MultiHertz 5.0 MHZ Adv. SieClear Dyn R 68 dB Map C Image Size 2 Tx Power 100% 29 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The Extensive View option will now be displayed on the Touch Screen. Select either view to display the desired size. Notes No. 29 SIEMENS Healthineers Exam Touch Screen SIEMENS . Healthineers ... Transducers 7C2 Add Exam Add Exam Preset Help Menu (e-manual) Abd Spine GYN OB Close Close Exam System FAST Early OB Edit Edit Exam Renal Pelvis Configuration Preset Bowel Lung Fetal Echo Virtual Keyboard Clear Ped Abd OB (Adv) Hide Image Hide Patient Exam Presets Parameters Image Param Page Icon End Exam End Exam Next Page 30 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The Touch Screen controls are displayed and labeled here. Notes No. 30 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Review external features • Explain Control Panel and Touch Screen • Discuss transducers and care of the system 31 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Finally, we will discuss the ACUSON Maple transducers and how to care for the system. Notes No. 31 SIEMENS Healthineers Transducers SIEMENS. Healthineers ... Convex Linear Phased array Micro Volume TEE Pencil convex 7C2 16L4 P4-2 10MC3 9VE4 5VT CW2 C5-2v 14L4a 8V4 11M3 9VC2 CW5 5C1a L10-5v 32 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The 15 transducers available for the ACUSON Maple ultrasound system are listed here. Notes No. 32 SIEMENS Healthineers System filter SIEMENS . Healthineers ... Clean air filters at least once a week to maintain proper system cooling 1. Power off the system and unplug the power cord from power supply 2. Push the air filter tray in to release locking mechanism and then pull tray from system 3. Rinse air filter with running water and allow to completely dry .... 33 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The filter is located on the back of the system. To clean the filter: 1. Power off the ultrasound system and unplug the power cord from the power supply 2. Push the air filter tray in to release the locking mechanism, and then pull the tray from the system 3. Rinse the air filter tray with running water and allow the filter to completely dry Check and clean the air filters weekly, or as needed, to maintain proper system cooling. Notes No. 33 SIEMENS Healthineers Cleaning the system SIEMENS . Healthineers ... 1. Power off the system and unplug the power cord from the power supply 2. Use clean gauze pad or lint-free cloth, lightly moistened with a mild detergent to gently wipe: • Touch Screen • Monitor • Control Panel 3. Dry surfaces with a clean lint-free cloth 4. As required, use an approved disinfectant wipe to disinfect the system and accessories 34 Unrestricted © Siemens Healthineers 2023 Speaker Notes: 1. Power off the ultrasound system and unplug the power cord from the power supply 2. Use a clean gauze pad or lint-free cloth, lightly moistened with a mild detergent to gently wipe: • Touch Screen • Monitor • Control Panel 3. Dry surfaces with a clean lint-free cloth 4. As required, use an approved disinfectant wipe to disinfect the system and accessories Notes No. 34 SIEMENS Healthineers Cleaning the trackball SIEMENS . Healthineers ... 1. Rotate ring around trackball and lift to remove 2. Remove trackball 3. Clean ring, trackball and trackball assembly with mild detergent or approved disinfectant 4. Place trackball into assembly 5. Place ring over trackball and rotate clockwise until it snaps into place 35 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To clean the trackball: 1. Rotate the ring around the trackball counterclockwise and carefully lift the ring 2. Remove the trackball 3. Clean the ring, trackball and trackball assembly with a cotton swab or lint-free pad moistened with a mild detergent solution (as required, use an approved disinfectant wipe to disinfect the ring, trackball and trackball assembly) 4. After allowing the trackball components to completely dry, place the trackball into the assembly 5. Place the ring over the trackball, aligning the tab with the point of attachment on the assembly, and rotate clockwise until the ring snaps into place Notes No. 35 SIEMENS Healthineers SIEMENS . Trademarks and disclaimers Healthineers ... ACUSON Maple is a trademark of Siemens Medical Solutions USA, Inc. 36 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No Speaker Notes. Notes No. 36 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS . Healthineers ... Questions? 37 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No Speaker Notes. Notes No. 37

  • ACUSON
  • Maple
  • NX Family
  • Sales
  • Training
  • Ultrasound
  • Doppler
  • Multispecialty
  • General Imaging
  • Cardiac
  • Vascular
  • OB
  • Obstetrics
  • Gynecology
  • 4D
  • 3D
  • 2D
  • Radiology
  • Cardiology
  • Echocardiography
  • TEE