Siemens Healthineers Academy

ACUSON Maple 1.0 Getting Started Presentation

Tool for describing more detailed information on how to use the system.

SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Maple Ultrasound System Getting Started 1.0 Software Release 1 Unrestricted © Siemens Healthineers 2023 Speaker Notes: In this presentation we will discuss getting started on the ACUSON Maple ultrasound system. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 2 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Here are the objectives for this presentation. We will start with demonstrating the patient registration. Notes No. 2 SIEMENS Healthineers Patient registration SIEMENS . Healthineers ... Configuration A Configuration System Configuration General 1 General 1 Trackball Behavi General 2 ? Institution Name ACUSON Trackball Speed Medium Display General 1 General 2 Display Custom Keys Regional Settings System Start Up Soft Keys Language English Active Transducer On Exam Measurement Text Annotation Body Ma Measurement Text Annotation 10/03/2023 Body Marker Printer th Confirmation Dialog Barcode Wireles Stress Echo 12 : 48 : 22 eSieScan Time Zone (UTC-08:00) Pacific Time (US & Canada) Clear Contrast Height and Weight Units Metric U.S. Screen Security Service Clip Store Printer ALdo Hide Barcode Beep on Button Press Wireless Beep after Store Completes Beep Volume Image Param UBIRy Doppler Volume Close Archive Security Service 3 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Select the System Configuration icon located on the left side of the Touch Screen, then select the General 1 tab. At initial installation, prior to starting an exam, check the following in System Configuration > General 1: • Institution name under Organization • Language, date and time under Regional Settings Notes No. 3 SIEMENS Healthineers Patient registration SIEMENS. Healthineers ... Starting an exam Patient 30 1 40 Exam : Deperi Focus @ 00.00 Review UD2 Friet Store UD 3 Print Store 2 Report 4 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Select Patient on the Control Panel to register a patient. Complete registration one of two ways: • Manual entry • Modality Worklist (MWL) Notes No. 4 SIEMENS Healthineers Patient registration SIEMENS. Healthineers .. Manual To manually register a patient: Register Edit Patient Data + + New Patient Patient Demographics Select New Patient Edit Patient Data Last Name Patient ID 12_10_2022_16_04_41 • First Name Date of Birth DD MM / YYYY Age • Enter the patient information, select Gender Male O Female Other transducer, exam and protocol Height BSA Weight mmHg • Select OK to begin imaging Exam Transducer 9VC2 Accession No. Exam GYN Indication Medical Information Date O LMP Additional Info DD MM / YYYY Gravida Para Aborta Order Information Performing Physician Referring Physician Operator OK Cancel 5 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To manually register a patient: • Select New Patient • Enter the patient information and select the Transducer, Exam and Protocol (if desired) • Select OK to begin imaging Notes No. 5 SIEMENS Healthineers Patient registration SIEMENS . Healthineers ... Worklist Patient Browser Worklist 1. New Patient Search ? In + New Patient / Edit Patient $/ Edit Patient Data Patient Last Nam 02/11/2017 US Only This system only Search with Cached List Worklist Patient ID to 03/11/2017 5 Search Clear Search Worklist Worklist Mpps Patient Name Patient ID Study Description Accession Numt Date/Time A_FirstName LastNa 39613873 53582877 171102/2043 B_FirstName LastNa 33299687 80032521 171102/2044 Clear Screen Hide Patient schedul Scheduled Procedure(s) Param Code Value Description State ScheduledProcedureStepDescription Suspended Code Value Meaning @F JORCOM, BIS Status : TCPIP - Ping succeeded. Ping Echo Select Cancel 6 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To Register a patient using a worklist server: • Select the Patient tab on the Touch Screen • Select Worklist on the Touch Screen or image screen • Select a scheduled study from the worklist or search for a specific patient/study by name, patient ID, etc. • Select the Transducer, Exam and Protocol • Select OK to begin imaging Notes No. 6 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 7 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss reviewing the steps to end, edit and restart an exam. Notes No. 7 SIEMENS Healthineers End Exam SIEMENS . Healthineers ... To end an exam: 7C2 16L4 Add Exam Workflow Select End Exam on the Touch 2D Contrast Elasticity SieScape eSieScan Screen Clarify VE Persist Full Screen Extensive View Clarify VE Levels Edge L/R Flip UID Flip Clear THI Biopsy Line Biopsy Screen Off Hide Patient Physio Settings > 4B Split Image Param Clip Settings Full FO End Exam ensity O DICE Med R/S Tint 2 Focus Width TEQ Gain MultiHertz 5.0 MHz Adv. SieClear 1 Dyn R 68 dB Map C Image Size Tx Power 100% 8 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To end an exam, select End Exam located on the left side of the Touch Screen. Please Note: End Exam is available in all imaging modes. Notes No. 8 SIEMENS Healthineers Edit patient data SIEMENS . Healthineers ... Register Edit Patient Data À. New Patient Patient Demographics G/ Edit Patient Data Last Name Patient ID 31_07_2017_14_42_25 Date of Birth DO MM YYYY Age Patient Suf Gender Male Female Other Height BSA Weight Exam Exam Transducer 12L3 Accession No. Exam Thyroid Indication Protocol Medical Information Additional Info Review Report Order Information Performing MD eferring MD Sonographer Cancel 9 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To edit information in the patient registration form during an active examination requires the following steps: • Select Patient on the Control Panel to return to the Patient Registration page • Select Edit Patient Data • Re-enter/edit the required information on the patient demographics form • Select OK to save changes Notes No. 9 SIEMENS Healthineers Restart an exam SIEMENS . Healthineers ... To restart an exam: Patient Browser how Fles| 1 month old Source Media|ID:1 Local Disk | Disk Space: 3.5GB) 293.0GB Patient Browser Search • Select Patient on the Control -‘ Queue Patient Last Nam from 02/1 1/2017 Worklist Patient ID to 02/11/2017 Search Clear Search Panel El Query Retrieve Sturdy List Total Soucies: 16(16) • Select Browser on the Touch W. New Sturdy Patient Name Patient ID DatefTime ClipsImages ME Archived LastName, A.FirstName 39613873 0211112017 14:08 27.5 Screen 02_11_2017_11_17.54 02/11/2017 11:17 LIE 0.9 HO 01_11_2017_13_58.59 01/11/2017 13:58 HD • Select the search period • Select the desired exam • Select Restart 275 Ml Selected Expert Debase Output Device| Not Active 10 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To restart an exam: • Select Patient on the Control Panel • Select Browser on the Touch Screen • Select the search period, if necessary • Click to select the desired exam • Select Restart to open the patient registration page • Select OK to restart the exam Please Note: Images, clips and volumes can be added to a closed study within 24 hours. Notes No. 10 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 11 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will demonstrate the workflow selections. Notes No. 11 SIEMENS Healthineers Workflow selections SIEMENS. Healthineers ... Transducer, exam and protocol To select an exam type from patient registration Exam and transducer can also be selected from the Touch screen Screen Exam 7C2 Abd Transducer C5-2v Exam Abd Abd Spine GYN OB Protocol Medical Information Adult Echo Additional Info Breast Bowel Lung Fetal Echo OB Clear Carotid Screen Ped Abd OB (Adv) Venous Hide 12 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Workflow selection includes the selection of the transducer, exam-type and protocol. Select from the Patient Registration screen, Touch Screen or Exam key. 1. The first option is during Patient Registration: • Select the Transducer • Select study type from the Exam drop-down menu • Select a Protocol, if desired • Select OK 2. The second option is through the Touch Screen: • Select transducer from the top left of the Touch Screen • Select the transducer-specific exam from the available options displayed on the Touch Screen • The active exam is displayed in blue Notes No. 12 SIEMENS Healthineers Protocols (eSieScan workflow protocols) SIEMENS . Healthineers .. ew Patient 16L4 Add Exam Workflow ? 2D Contrast Elasticity SieScape eSieScan Clarify VE Persist Full Screen Extensive View Clarify VE Levels Edge LUR Flip UID Flip Clear THI Biopsy Line Biopsy Screen Transducer 16L4 Hide Patient Physio Settings > 4B Split Exam Thyroid Clip Settings Full FOV Protoco End Exam Medical Information Adult Echo High Density DICE Med R/S Tint 2 Focus Width TEQ Gain Additional Info Breast MultiHertz 5.0 MHZ Adv. SieClear Dyn 68 dB Map C Image Size Tx Power Carotid Venus 1 2 13 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Select a protocol (eSieScan workflow protocols) in two different ways: 1. During Patient Registration - select the protocol from the drop-down menu on the Patient Registration screen 2. Touch Screen: • Select the eSieScan tab on the top right of the Touch Screen • Select the desired protocol • The Touch Screen displays all customized protocols (e.g., Shoulder, Cardiac 2, Thyroid 2) The system automatically activates the first view of the protocol once the live scanning screen initiates. Please Note: This presentation uses the term “protocols” to refer to the eSieScan workflow protocols displayed as eSieScan on the ultrasound system. Notes No. 13 SIEMENS Healthineers Image parameters and patient information SIEMENS . Healthineers ... A 7C2 1614 Add Exam Workflow Patient Name Patient ID Date Time ? 20 Contrast Elasticity SieScape eSieScan Renal Tx Power 98% Persist MI 0.65 Clarity VE Full Screen Extensive View TIS 1.6 TIB 2.2 3.3 MHZ Clarify VE Levels Edge UR Flip 3125 Hz U/D Flip Gate 12.5 mm -11 GB 8 fps Gear THI Biopsy Line Biopsy Hide Patient Physio Settings> 48 Split Clip Settings Full FOV End Exam High Density DICE Med R/S Tint Focus Width TEQ Gain MultiHertz 5.0 MHz Adv. SieClear Dyn R 68 dB Map Image Size 2 Tx Power 100% 14 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The imaging screen displays the Patient Banner and the imaging parameters. Customize banner display options are located in the Configuration Menu under General 2. During the exam, remove the patient name for a particular image by selecting the Hide Patient key on the left side of the Touch Screen. Use these images for teaching files or presentations. The patient banner remains hidden for all images stored after selected. Select the Hide Patient key again to re-display patient information. To hide the imaging parameters during an exam, select the Image Param key on the left side of the Touch Screen. Select the Image Param key again to re-display the imaging parameters. Notes No. 14 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 15 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss how to produce customized exam presets. Notes No. 15 SIEMENS Healthineers Creating a user-defined exam SIEMENS . Healthineers ... To create a user-defined exam preset: A ₱ 7C2 16L4 Add Exam Workflow • Select the transducer and exam from the Touch Screen • Select Add Exam • Enter a name for the exam Select Create Add Exam • ? Create Close OB Test X @ & 7 8 19 0 X Tab w p 16 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To create a user-defined exam preset: • Select the required transducer and Exam type from the Touch Screen exam list • Select Add Exam • Enter a name for the exam • Select Create to save the settings and add the new exam to the list Please Note: Do not begin the filename with a percent sign (%), and do not use the following characters in the file name:/\ : * ? " < > . Notes No. 16 SIEMENS Healthineers Editing a user-defined exam SIEMENS . Healthineers ... To edit a user-defined exam preset: A 7C2 Abd Add Exam Workflow • Select the exam preset you ? Abd Spine GYN OB Close want to edit • Adjust the parameters Renal FAST Pelvis Early OB Edit • Select the desired transducer tab Bowel Lung Fetal Echo Select Edit Clear • Screen (continued on next slide) Ped Abd B (Adv) Hide Patient Image Param 17 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To edit a user-defined Exam preset: • Select the user-defined Exam preset you want to edit • Adjust all the parameters • Select the desired transducer tab • Select Edit located on the right side of the Touch Screen (Continued on next slide) Notes No. 17 SIEMENS Healthineers Overwriting a user-defined exam SIEMENS . Healthineers ... To overwrite a user-defined exam preset: Edit Exams • Select the desired user-defined exam C5-20 [ Page 1 ] Custom Exam Abd • Select Overwrite OB TEST Abd Name OB TEST Renal • Select Set Default to change the default Bowel Overwrite Rename exam for the selected transducer • Select Yes to confirm Confirmation Spine Lung Overwrite Exam? Yes No Add Blank Set Default Delete Restore Settings Close 18 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To overwrite the selected exam with the current imaging settings: • Select the desired user-defined exam • Select Overwrite • To change the default exam for the selected transducer, select the desired exam and select Set Default • Select Yes to confirm Notes No. 18 SIEMENS Healthineers Renaming a user-defined exam SIEMENS . Healthineers ... To rename a user-defined exam preset: Edit Exams Custom Exam • Select the desired user-defined exam C5-2v Replace the information in the Name field GYN Name OB Tes • Pelvis • Select Rename Create Rename • Select Set Default to change the default exam for the selected transducer OB OB Test OB Early OB Fetal Echo OB (Adv) V Add Blank Set Default Delete Restore Settings Close 19 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To rename the selected exam: • Select the desired user-defined exam • Replace the information in the Name field • Select Rename • To change the default exam for the selected transducer, select the desired exam and then select Set Default Tip: Use the arrows to adjust the display position of the exam types on the Touch Screen Notes No. 19 SIEMENS Healthineers Deleting a user-defined exam SIEMENS . Healthineers .. To delete a user-defined exam preset: A 7C2 Add Exam Workflow Abd ? Abd GYN Close • Activate an exam preset other than the one you Spine want to delete Renal FAST Pelvis Early OB Edit • Select the desired transducer tab • Select Edit Edit Exams • Select the desired exam Select Delete Custom Exam • Name OB Test Overwrite Rename 08 Test Early OB Fetal Echo OB (Adv) Add Blank Set Default Delete 20 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To delete a user-defined Exam preset: • Activate an Exam preset you do not want to delete • Select the desired transducer tab and select the Edit key from the right side of the Touch Screen • Select user-defined Exam that you do want to delete • Select Delete Please note: A user-defined exam cannot be deleted while active. Notes No. 20 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 21 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Next, we will discuss how to use the review functions. Notes No. 21 SIEMENS Healthineers Activate review mode SIEMENS . Healthineers ... Active study Patient Browser Review ? General Review Patient Select all Deselect All 1x1 1X2 2x2 Archived Report Show Selected Slide Show 3x3 4x4 5x5 Stress Echo Review Exam Clear Screen Teaching File Export PC Printer USB B&W USB Color Printer Printer AHP Review Hide Patient Delete syngo WI Image Param Report Save Reset Marker End Exam Page DICOM Print Cine Speed Cine Frame Cine Start Marker Cine End Marker Color 22 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To activate the review mode during an active examination, press the Review key on the Control Panel. You can view, print, export or delete images as well as create a teaching file from the Review function. Notes No. 22 SIEMENS Healthineers Activate review mode SIEMENS . Healthineers ... Saved study Patient Browser Show Fles| 1 month old Source Moda|ID:| Local Disk | Disk Space: 3.5GB1 293.0GB Patient Browser Search E‘ Queue Patient Last Nam from 02/1 1/2017 Worklist Patient ID to 02/11/2017 Search Hear Search Patient El. Query Retrieve Study List Total Soucies: 16(16) New Study SE Patient Name Patient ID DatefTime ClipsImages ME Archived LastName, A_FirstName 39613873 0211112017 14:08 27.5 LIE 27.5 HD Restart 02_11_2017_11_17 54 02/11/2017 11:17 Clave Study 60 HD 01_11_2017_13_58_59 01/11/2017 13:58 0.9 0.9 HD Exam Review Report 27.5 MB Selected Export Delete Output Device| Not Active 23 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To activate the review mode for a saved study: • Select Review key on the Control Panel • Double click the desired patient study from the patient browser You can view, print, export or delete images as well as create a teaching file from the Review function. Notes No. 23 SIEMENS Healthineers Review Touch Screen layout SIEMENS. Healthineers ... Active study Review tab Patient Browser Review Image layout selections General Review Select all Deselect All 1x1 1X2 2×2 Archived Report Create Slide Show 3x3 4x4 5x5 file/display Stress Echo Review options syngo® Arterial Clear Screen Teaching File Export PC Printer USB B&W USB Color Printer AHP Health Package Hide syngo WI (AHP) Patient Delete Image Param End exam Save Reset Marker selection End Exam Page DICOM Print Cine Speed Cine Frame Cine Start Marker Cine End Marker 24 Unrestricted © Siemens Healthineers 2023 Speaker Notes: When in the review page the options are: • Slide Show – the system will display the exam in a slide show format • Teaching File – this will allow the user to place different images into one folder • Export – this will export the exam in JPG/AVI or DICOM format • Image Layout selections – allows the user to display how many images on the monitor • AHP – this is where the user can use the syngo® Arterial Health Package (AHP) • End Exam – will end the exam Notes No. 24 SIEMENS Healthineers Review on-screen layout display and options SIEMENS . Healthineers ... SIEMENS › Image PATIENT NAME PATIENT NUMBER ACUSON 07112/2017.07:48.57 number 14L4a Thyroid TE Power 100% MI0.05 T& 10 TB 10 8208 Ha 1x1 1X2 2x2 3x3 4x4 5×5 Thumbnails Image layout and paging selections Page 13 /13 Cine bar 25 Unrestricted © Siemens Healthineers 2023 Speaker Notes: When review is activated, the system displays all images and clips saved with the study in the thumbnail panel and displays at least one image or clip on the review screen. The number of the image is displayed in the upper right corner in the patient banner. The Touch Screen displays the available image layouts - the 1x1 layout is shown here. To scroll through the thumbnails, use the Pointer and Set key or rotate the rotary dial labeled Page on the Control Panel. To select specific images for review double click the image or required thumbnail. To cancel the selection, click the image again. To select all images on the review screen, select Select all. To cancel the selection of all images, select Deselect All. Notes No. 25 SIEMENS Healthineers Review onscreen multi-layout display SIEMENS . Healthineers ... SIEMENS ETES Active image 1x1 1X2 2x2 3x3 4x4 5x5 Image type indicator - Cine clip 26 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To change the display format of the onscreen images, select a different format from the available options listed on the Touch Screen. This example is a 4x4 image display layout. Note the active image has a thick border around the thumbnail and clips are identified by the Cine clip icon in the bottom right corner of the thumbnail. Notes No. 26 SIEMENS Healthineers Viewing clips Touch Screen options SIEMENS . Healthineers' ... A Patient Browser Review PATIENT NAME PATIENT NUMBER ACUSON 14L4a ? General Review Select a Deselect All 1x1 1X2 2x2 Archived Report DTCE Me Show Selected Slide Show 3x3 4x4 5 x5 Fess Echo Screen eaching File Export PC Printer Delete yngo WI Save Reset Marker End Exam Page DICOM Print Cine Speed Cine Frame Cine Start Marker Cine End Marker EE Color 57 C Play/Pause Cine controls Clip Current Clip start frame end marker marker marker 27 Unrestricted © Siemens Healthineers 2023 Speaker Notes: When viewing a clip: • Use play/pause options to control clip function • Rotate Cine Frame designated rotary control to review the clip frame by frame • Rotate Cine Speed designated rotary control to select the desired speed • Rotate Cine Start Marker and/or Cine End Marker designated rotary controls to adjust the length of a clip • Select Save to finalize changes Notes No. 27 SIEMENS Healthineers Slide show SIEMENS . Healthineers' ... System Configuration Utility A Patient Browser General 1 dip Playback General 2 Play Only Active Clips Display Play All Clips Loop Aligned Custom Keys Soft Keys Slide Show Exam Select all Deselect All Image Duration (sec) Measurement Text Annotation Number of Replay Loops Body Marker Show Selected Slide Show Stress Echo eSieScan Contrast Clear Screen Teaching File Export Cip Store Wireless Hide Patient Delete Network Utility Image Param Archive Security Service End Exam Page 2/2 DICOM Print 28 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To select specific images for slide show review: • Select the image or required thumbnail • To cancel the selection, select the image again • To select all images on the review screen, select Select all • To cancel the selection of all images, select Deselect All • Select Slide Show to view the slide show for the selected images Please Note: Slide Show preferences may be modified under System Configuration > Utility. Notes No. 28 SIEMENS Healthineers Teaching file SIEMENS . Healthineers ... Patient Browser Teaching File Select Teaching File Teaching File Name Clips Images Select all Deselect All Show Selected Slide Show Clear Screen Teaching File Export Append Hide Patient Delete ile Name Image My Teaching File New Param Status End Exam Page DICOM Print 212 Close Color 29 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To select specific images for a teaching file, perform the following steps: • Click the image or required thumbnail • To cancel the selection, click the image again • To select all images on the review screen, select Select all • To cancel the selection of all images, select Deselect All • Select Teaching File • Under Teaching File, name the file and select New or select an existing file and select Append • Select Close Notes No. 29 SIEMENS Healthineers Export from patient browser SIEMENS . Healthineers ... USB or CD/DVD Patient Browser Show Files 2 weeks old Source Media| [D] Local Disk | Dick Space: 2.5G8 / 293.DGB Patient Browser Search Export Queue Patient Last Nare Destination Now Study Patient ID [G:] CD/DVD Disk Space: OMB / 703MB G:| CD/DVD Study Ust [H:] GRIFFIN THE ID CEps 7080553 0 Total Studies: 7(7) Clipsilmages MB Archived S'E HD, USB 0/1 HO,USB 012 6.7 HO,USB 26.7 HD,USB Identification 015 15.2 HO,USB THYROID. De-identify Anonymous 2.8 HD PATIENT NAME, 2/10 33.7 HD Format Options DICOM Finalize Eject TiffiAvi Eject Status Ready Export Close Output Device 30 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To export a study to CD-R/DVD or USB: • Insert CD-R/DVD or USB into the left side of the Touch Screen • Select the patient name in the Patient Browser • Select Export • Select DICOM or TIFF/AVI as the export format • Select CD/DVD or desired USB drive as the destination and select Export Notes No. 30 SIEMENS Healthineers Import studies from USB or CD–R/DVD SIEMENS . Healthineers ... Patient Browser Show Files 2 weeks old Source Media [H:] | Disk Space: 1.868/7.5GB 2. Patient Browser A Search Queue Patient Last Nam from 25/10/2017 Patient In to 25/10/2017 Search Clear Seare New Study Restart Study List Total Studies: 2(2) Close Study Patient Name Patient ID Date/Time Clips/Images MB Archived 25_10_2017_07_26_22 25/10/2017 07:26 0. 1 HD,USB 24_10_2017_09_51_38 24/10/2017 09:51 3714 HD,USB 0.1 MB Selecte Output Device| Not Active 31 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To import a study from a CD-R/DVD or USB: • Insert CD-R/DVD or USB • Select CD/DVD or desired USB drive from Source Media in the Patient Browser • Select the patient name/study • Select Import Notes No. 31 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Demonstrate patient registration • Review the steps to end, edit and restart an exam • Demonstrate workflow selections • Produce customized exam presets • Identify review functions • Discuss backup and restore 32 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Lastly, we will discuss how to back up and restore an exam preset. Notes No. 32 SIEMENS Healthineers Back-up and restore presets SIEMENS. Healthineers ... System Configuration Service General 1 Snten information General 2 ACUSON Juniper V830 Display 900401 Custom Keys Version VB308 (2.5.2302.1) Soft Keys Systeme V8308 (2.5.2302.1) System Internal: 2.5.2302.1 Exam SIN: 900401 [20190930 23:02:371 PIN: 11335791 |20210721 17:21:44| Measurement OS Configuration: GRIFFIN-VB308-WINDOWS-C161460-11202 Framework: 02.09.2023.0110 [20230209] Text Annotation Platform Software: 02.09.2023.0843 [20230209] PIM5:02:09.2023.0503 [20230209] Body Markess UBE: 02.09.2023.0202 [20230209] Imanines Croftuna- no no 3013.0357 10920301 Stress Echo esieScan Service Contrast Remote Clip Store Printer Remote Assistance Wireless Restore Factory Settings Network Utility Archive curit Service Dose 33 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To back-up and restore system presets: • Access the configurations settings and then Select Service. (Continued on next slide) Notes No. 33 SIEMENS Healthineers Back-up and restore presets Service Please enter Service Key Remote Backup & Restore Remote Assistance OK Upload / Enter new Service Key Select Service to open the Select OK Select Backup & Restore Service Software page to move to next step 34 Unrestricted © Siemens Healthineers 2023 Unrestricted © Siemens Healthineers 2023 Speaker Notes: • Select Service to access the settings in the service software • Select OK • Select Backup & Restore (Continued on next slide) Notes No. 34 SIEMENS Healthineers Backup Backup Name Description Maple 4D SubPresets[1.00.000]20230730055919 3D or 4D Settings Maple eSieScan Workflow Protocol[1.00.000]202307 |eSieScan Workflow Protocol SELECT Maple License Info[1.00.000]20230730055919 License Information Backup Maple M&R User Defined[1.00.000]20230730055919 M&R User Defined Settings Maple Security Settings[1.00.000]20230730055919 Security Settings Restore Maple Service Image[1.00.000]20230730055919 Service Images Maple Service Log[1.00.000]20230730055919 Service Logs Maple Service Test Report[1.00.000]2023073005591 Service Test Report Maple Stress Echo[1.00.000]20230730055919 Stress Echo Maple System Preset[1.00.000]20230730055919 System Configuration Maple User-Defined Exam[1.00.000]2023073005591 User defined Exam Select all Deselect All Destination [E:] ORANGE ! Backup Close 35 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To save configuration settings and user-defined exam settings to a USB storage device: • Insert the external storage device into the USB port • Select Backup from the Select list • Select the check box for each required setting and then select Next • Select the desired destination drive and then select Backup • Select OK Notes No. 35 SIEMENS Healthineers Restore Restore Name Description Maple 4D SubPresets[1.00.000]20230730055958 3D or 4D Settings Maple eSieScan Workflow Protocol[1.00.000]202307 |eSieScan Workflow Protocol SELECT Maple License Info[1.00.000]20230730055958 License Information Backup Maple M&R User Defined[1.00.000]20230730055958 M&R User Defined Settings Maple Security Settings[1.00.000]20230730055958 Security Settings Restore Maple Service Image[1.00.000]20230730055958 Service Images Maple Service Log[1.00.000]20230730055958 Service Logs Maple Service Test Report[1.00.000]2023073005595 Service Test Report Maple Stress Echo[1.00.000]20230730055958 Stress Echo Maple System Preset[1.00.000]20230730055958 System Configuration Maple User-Defined Exam[1.00.000]2023073005595 User defined Exam Select all Deselect All Destination [E:] ORANGE : Restore Close 36 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To retrieve saved settings from a USB storage device: • Insert the external storage device into the USB port • Click Restore from the Select list • Select the required storage device from the Destination list • Select the check box for each required file type and then click Restore • Click OK to confirm the completion message • Click Close; The system displays a message that power must be cycled to the system for completion of the operation • Click OK to restart the ultrasound system Please Note: The system will perform two reboots during Restore. The first reboot does the upload, the second reboot resumes normal operation. Notes No. 36 SIEMENS Healthineers SIEMENS . Trademarks and Disclaimers Healthineers ... • ACUSON Maple and eSieScan™ workflow protocols are registered trademarks of Siemens Medical Solutions USA, Inc. • syngo® Arterial Health Package (AHP) is a registered trademark of Siemens Healthcare GmbH 37 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No speaker notes. Notes No. 37 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS . Healthineers ... Questions? 38 Unrestricted © Siemens Healthineers 2023 Speaker Notes: No speaker notes.

  • ACUSON
  • Maple
  • NX Family
  • Sales
  • Training
  • Ultrasound
  • Doppler
  • Multispecialty
  • General Imaging
  • Cardiac
  • Vascular
  • OB
  • Obstetrics
  • Gynecology
  • 4D
  • 3D
  • 2D
  • Radiology
  • Cardiology
  • Echocardiography
  • TEE