This job aid provides instructions to view, create, edit, activate, and deactivate linearity lots from the POCcelerator™ Web Linearity Material Setup screen.

POCcelerator™ Web – SIEMENS Healthineers View and Manage Linearity Lots Job Aid Linearity material setup Lot number Device model .... View Linearity Lots Manufacturer Roche x Analytes .... Days remaining All lots 2 In order to view and manage linearity lots, users must + New lot Manufacturer Expiration date Device model Levels supported Comments Status have the appropriate permissions to the Web Setup Lot information Supported levels Linearity user group. Lot number . 1234 ¥|Level 1 Lin 12341 Level 2 Lin 12342 Manufacturer . Roche ¥ Level 3 Lin 12343 Level 4 Lin 12344 Note: Users can only view linearity lots currently Expiration date 10/1/2018 ¥ Level 5 Lin 12345 Level 6 Lin 12346 Comments Type your comment hare. assigned to device models. Comment history Level 7 Lin 12347 1. Select Linearity > Linearity material setup Activation history Device model(s) assigned 2. Select the appropriate filter options Activate 4 Now device modell 3. Select the Lot number to display lot details Status Updated by Device model Activebed 10/1/2018 2:08:47 PM 1000 Accuchek inform II × 4. Select the red X icon to close the detail view 10 20 50 Page 1 of 1 [1 itmoral 1 10 20 50 Page 1 of 1 [1 itaral 1 > Test and test ranges Analyos Unit Device model Level LEM Îtich Decimal Target SD Whole blend mg/dl Accuchek inform Il 130 0 105 24 35 Whole bloc Accuchek inform Il 135 0 110 21 Glu Whole black mg/dl Accuchek inform il 90 14D 0 175 R Whole blond mg/dl Accuchek informIl 4 100 150 0 125 Whole blond mg/dl Accuchek informIl 5 Glu Whole blood mg/dl Accuchek inform Il Whole blond Accuchek inform Il 10 20 Page 1 of 1 [/ itural 1 > 1 Effective Date: 20 Apr 2022 | HOOD05162003270754 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Web – SIEMENS Healthineers View and Manage Linearity Lots Job Aid All lots Reset filters 2 + New lot Lot number Manufacturer Expiration date Device model Levels supported Comments Status Create Linearity Lots 3 Lot information 4 Supported levels Lot number . Level 1 Level 2 Users can only create linearity lots for authorized Manufacturer Level 3 Level device models. Expiration date Level 5 5 Level 6 Comments 1. Select Linearity > Linearity material setup Type your comment here ... Comment history Level 7 2. Select + New lot 3. Enter the lot information details 4. Select the Supported levels Activation history Device model(s) assigned 5. Select + New device model and select the device Activate 5 + New device mode model to assign to the lot Status JpdatedOn UpdatedBy Device model 6 6. Select the checkbox No data 10 20 50 Page 1 of 1 (0 items) < 1 > 7. Under Test and Test Ranges, enter the Low and 10 20 50 Page 1 of 1 (0 items) High test range values for each analyte and selected level 7 Test and test ranges 8. Select the green checkmark button to save the lot Analyte Y Sample Y Unit Device model Y Level Low High Decimals Target Variance(%) SD No data 10 20 50 Page 1 of 1 (0 items) < 1 > 8 1234 Roche 10/31/2018 Accuchek inform II 12345.6,7 Copy lot X 11111 Siemens Healthcare GmbH 10/5/201 Rapidpoint 500 123,45 Copy lot X 2 Effective Date: 20 Apr 2022 | HOOD05162003270754 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Web – SIEMENS Healthineers View and Manage Linearity Lots Job Aid Edit Linearity Lots Linearity material setup Users can only edit a linearity lot if authorized for both 2 Lot number Device model the location the device currently resides in and for the Manufacturer Analytes .--- device model the device belongs to. Days remaining 1. Select Linearity > Linearity material setup All lots Reset filters 2. Select the appropriate filter options + New lot 3. Select the Lot number to display lot details Lot number Manufacturer Expiration date Device model Levels supported Comments Status 4. Update the lot information, if desired 3 1234 Roche 10/31/2018 Accuchek inform II 1,2,3,4,5,6,7 Copy lot X 5. Select the green checkmark button to save the lot Lot information Supported levels OR select the red X icon to close the detail view Lot number * 11111 Level 1 Lin111111 Level 2 Lin111112 Manufacturer Siemens Healthcare GmbH ¥ Level 3 Lin111113 ¥ Level 4 Lin111114 4 Expiration date 10/5/2019 ¥ Level 5 Lin111115 Lin111116 Comments Type your comment here ... A Lin111117 Comment history Level 7 3 Effective Date: 20 Apr 2022 | HOOD05162003270754 Unrestricted © Siemens Healthineers, 2022 POCcelerator™ Web – SIEMENS Healthineers View and Manage Linearity Lots Job Aid Activate and Deactivate Linearity Lots Lot information Supported levels Lot number * 1234 Level 1 Lin12341 v Level 2 Lin 12342 1. Select Linearity > Linearity material setup Manufacturer * Roche Level 3 Lin12343 Level 4 Lin12344 2. Select the appropriate filter options Expiration date 10/31/2018 ¥ Level 5 Lin12345 Level 6 Lin 12346 3. Select the Lot number to be activated or Comments Type your comment here ... Level 7 Lin12347 deactivated Comment history 4. Under Activation history, select the Activate checkbox to activate the lot or unselect the Activate checkbox to deactivate the lot Activation history Device model(s) assigned 5. Select the green checkmark button to save the lot ¥ Activate + New device model Status Updated on Updated by Device model Activated 10/1/2018 2:08:47 PM 1000 Accuchek inform II X 10 20 50 Page 1 of 1 (1 items) < 1 10 20 50 Page 1 of 1 (1 items) < 1 > Test and test ranges Analyte Y Sample Unit Device model Y Level LOW High Decimals Target Variance(%) SD Glu Whole blood mg/dl Accuchek infor .. 1 80 130 0 105 24 35 Glu Whole blood mg/dl Accuchek infor .... 2 85 135 0 110 23 35 4 Effective Date: 20 Apr 2022 | HOOD05162003270754 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. POCcelerator and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 5 Effective Date: 20 Apr 2022 | HOOD05162003270754 Unrestricted © Siemens Healthineers, 2022

  • poccelerator
  • poccelerator web
  • pocweb
  • linearity
  • lots
  • create
  • view
  • activate
  • deactivate