Siemens Healthineers Academy

Performing Autocheck on the Atellica® Sample Handler Connect Job Aid Version 1.26 and Above

This job aid provides instructions on how to perform the daily maintenance task of Automated Atellica® Sample Handler Connect Autocheck.

Performing Autocheck on the Atellica® Sample Handler SIEMENS Healthineers Connect Job Aid Performing Automated SHC Autocheck Maintenance 6 LabM The SHC Autocheck is an automated maintenance All Activities ? =X mber 20 activity that tests the health of various SHC Filters Tx Clear Module : SHC Activity Type: All Frequency : All components. 2 Module Module Activity Last Completed SHC The system alerts the operator 15 minutes before Activity Type SHC SHC Autocheck 3 September 8, 2021 View Details All 4 Perform the scheduled activity begins. After the system Mond Frequency Mark as Completed 27 AIL initiates the SHC Autocheck, the SHC pauses Q Search Activity Procedure Details sample transfer until the Autocheck completes in approximately 5 minutes. 10 The task will run automatically daily, but can be 17 run manually if needed: 24 1. Navigate to Maintenance > All Activities 31 2. From the Filters Module drop-down menu, select the appropriate Sample Handler module 3. Select SHC Autocheck 4. Select Perform > OK Close ETS All Activ 5. Wait for autocheck to complete Template Effective Date: 10 Aug 2021| HILS 2223 1 Effective Date: 11-Oct-2021| HOOD05162003227795 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 2 Effective Date: 11-Oct-2021| HOOD05162003227795 Unrestricted © Siemens Healthineers, 2021

  • attelica
  • attellica
  • atelica