Papillary Carcinoma (USA)
TiCEM showed a good correlation with MR:
IN2D, DBT, TiCEM, US, MR.
73 year old lady with no symptoms. Routine screening. These are the insight to the views, synthetic views. And. And asymmetry was detected in the clinical view of the right breast. If we move. To the tomos. You can see and the regular indistinct mass. In the Criminal Code view and also in the EMILO view. The other breast was normal. If we analyze the detail. This case showing this suspicious lesion clearly detected on termo not so clear on the MO conventional view. We performed a Tyson study. And. As you can see, this is an enhancing month. Suspicious mass. So by your city was performed. And this was the correlation with ultrasound and MRI. On MRI we detected an additional non mass enhancement. Posterior to the index lesion. That additional lesion did not have any correlation with ultrasound nor tomosynthesis or mammography. That is why the surgeon excised a larger specimen and the final result was only one malignant lesion index lesion and the additional lesion was a false positive case. Of MRI. And finally, the result was a popularity cancer measuring 6 millimeters. So Tyson showed very good correlation with MRI.
1/1/2022 12/29/2021 43 23 5.0 Digital Breast Tomosynthesis and Contrast Enhanced Mammography Prof. Dr. Luis Pina Breast Imaging Department (Radiología mamaria) Clínica Universidad de Navarra, Pamplona / Spain SIEMENS . 08_TICEM_1, PID3644 Healthineers * 1/1/2022 F PID3644 Series Navigator INSIGHT_2D Add Study PID3644 11/1/2021 (Study date) Current MG, 12/1/2021 n.a ., 4 mon ... Prior 01 Mamograffa unilateral con contraste RMLOLE INSIGHT_CEM_RML Viewing Favorite Layouts MR DYN US C.US | C .... MR.Dyna ... MR.Empty ReportFlow BASIC Printing Tools Findings MR 4:20 PM Clinical information 73-year-old female Asymptomatic LCC LMLO Slice 21 / 48 Slice 28 / 49 Slice 16 / 48 Slice thickness: 1.00 mm Prior 01 Prior 01 Slice 32 / 46 RCC Recombined RMLO LowEnergy 1/1/2022, F Subtraction 3:53:10 PM 1976 IMA 52 1 CLINICA UNIVERSITARIA DE 12/02/21 10:51:29AM ADM Mama FR ultrasound Unsupported, 12/1/2021 n ... CEM bila .. SP H15.2 SL 1.5 mm p2 Zoom 1.77 10:11 PM check MI 0.30 Tis 0.1 ML6-15 SL 1 ML6-15 Free Map H15.2 4:22 PM Pathology Papillary carcinoma 5 mm Conclusion TiCEM showed a good correlation with MRI. Siemens Healthcare GmbH, 2022 Sometimes IN2D images (= synthetic mammograms) are shown while verbally referring to the conventional mammograms. The products/features (mentioned herein) are not commercially available in all countries. Their future availability cannot be guaranteed. Results from case studies are not predictive of results in other cases. Results in other cases may vary. The statements by Siemens' customers described herein are based on results that were achieved in the customer's unique setting. Since there is no "typical" setting and many variables exist (e.g ., hospital size, samples mix, case mix, level of IT adoption) there can be no guarantee that other customers will achieve the same results. Dr. Luis Pina is employed by an institution that receives financial support from Siemens Healthineers for collaborations. SIEMENS
- in2d
- ticem
- dbt