
ACUSON P500 Ultrasound System 3.0 General System Overview Presentation
This job aid provides information of the external features on the ACUSON P500 system at 3.0 software.
SIEMENS Healthineers SIEMENS Healthineers ... ACUSON P500 Ultrasound System General System 3.0 Software Release 1 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This presentation provides an overview of the ACUSON P500 Ultrasound system and the primary components. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Explain the General System • Discuss the Cart and Peripheral Options • Discuss Service Features • Review Care and Cleaning SIEMENS 2 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here are the objectives of this presentation and we will start with the general system overview. Notes No. 2 SIEMENS Healthineers General system SIEMENS. Healthineers ... Imaging Key Features General Imaging Point of Care Transducers Hand-Carried Cardiology Emergency – FAST 12 Transducers Touch User interface Intracardaic Imaging TEE TEE Transducer Integrated SMART Cart with 3 transducers supported OB / GYN MSK 4 ICE Catheters Advanced Imaging technologies Pediatrics Automated workflow eSieLink remote assistance 3 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The ACUSON P500 ultrasound system supports General Imaging, including Abdomen, OB/Gyn, Pediatrics, Focused Assessment with Sonography in Trauma (FAST) exam, Lung, MSK and Small Parts. Also, Cardiology for Adult and pediatric including Stress Echo, 2D Intracardiac Imaging with AcuNav ultrasound catheters and SoundStar® Catheters, 2D Transesophageal Echocardiogram (TEE), and Point of Care applications. The system is a hand-carried ultrasound system with a touch user-interface. An integrated SMART Cart is available that allows up to three transducers to be connected. The system has many advanced imaging technologies that will be discussed in the Major Modes presentation including Automated workflow with eSie Measure supporting Cardiac measurements. TM The system has twelve transducers, including a TEE transducer and four intracardiac catheters. Notes No. 3 SIEMENS Healthineers System architecture SIEMENS . Healthineers ... • Windows® 10 embedded • Data Encryption (Bitlocker) • All-digital beamformer technology --- • Adaptable software-driven architecture • Gateway for advanced technologies SIEMENS • Integrated technologies from other platforms 4 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system’s core architecture is built on the ACUSON X Family of products. Utilizing the Windows®10 Operating system including data encryption, this system provides the latest in technology and flexibility. Complete with 180 GB of memory, it provides excellent speed, storage and review capability. The system utilizes digital beamformer technology which provides signal integrity throughout the entire signal path. This provides excellent wide-bandwidth imaging which also provides precise and sensitive color Doppler. This technology migrated from our premium Siemens Healthineers platforms. The Parallel Quad beam formation provides up to 5088 processing channels for increased temporal resolution and fast processing speeds. The mid-processor on the system provides the gateway for advanced technologies such as: Advanced SieClear TM Spatial Compounding, TEQ TM ultrasound technology, Siemens remote technologies (SRS)*, Dynamic Persistence and Auto Flash Artifact Suppression. These technologies provide increased usability and diagnostic confidence. This mid-processor allows for improved software upgradability and integration flexibility. * Note: SRS is not available in all countries. Check with your local service organization. Notes No. 4 SIEMENS Healthineers System specifications SIEMENS. Healthineers ... • Dimensions • 40.2 cm (l) x 37.4 cm (h) x 7.15 cm (d) – closed • 40.2 cm (l) x 37.4 cm (h) x 36 cm (d) – open • Weight • 7.1 kg or 15.65 pounds (with battery installed) • 6.45 kg or 14.46 pounds (without battery) SIMINS Normal Boot up is 90 seconds Shut Down is Hibernate Boot up is 15 seconds Shut down is 5 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The systems is 40.2 cm (L) X 37.4 cm (H) x 7.15 cm (D) when closed. 15.8 in x 14.7 in x 2.8 in The systems is 40.1 cm (L) X 37.4 cm (H) x 36 cm D) when open. 15.8 in x 14.7 in x 14.2 in The system weighs 7.2 kg / 15.65 lbs. with the battery installed. The system offers a large handle for ease of carrying. The normal boot up time is 90 seconds and XXX to shut down. The Hibernate mode option will appear when shutting down the system and reboot up time is 15 seconds and XX to shut down. Please note that a complete shut down must be performed within 24 hours or after 20 hibernate actions. Notes No. 5 SIEMENS Healthineers Transducer options SIEMENS. Healthineers ... • P4-2 Transducer • CH5-2 Transducer P8-4 Transducer • VF13-5 Transducer • • VF10-5 Transducer • CW2 Transducer ACUSON AcuNav TM • EC9-4 Transducer • Catheter 8F / 10F • SoundStar Catheter 8F / 10F • VF16-5 Transducer • TEE 5VT Transducer • L10-5v Transducer • 18H5 Transducer • CW5 Transducer • 11M3 Transducer 6 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are 12 transducers, a TEE transducer and 4 catheters that are supported. Full specifications can be found in the transducer flyer. Notes No. 6 SIEMENS Healthineers Supported exam types SIEMENS. Healthineers ... • Abdominal and Renal Exam Exam Selection • Emergency Medicine (FAST) O Exam Selection Edit Exams Transducer Exam Neo Head • Lung 8 P8-4 Ped Abd Ped Echo Default • Vascular (CV, Venous, Arterial) Renal • Small Parts Breast, MSK CW2 • • OB/GYN including early OB, Pelvis • Neo Head • Pediatric Abdominal • Cardiac • Pediatric Echo • Intracardiac Echocardiography 7 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system supports 18 Exam types. Notes No. 7 SIEMENS Healthineers Touch screen SIEMENS. Healthineers ... • 15.4 in (39cm) infrared (IR) touch screen SIEMENS • Resolution: 1280 X 800 pixels • Monitor view angle: 176 degrees ACTISON P500 • Multi-domain vertical alignment technology ...................................................................................................... SIEMENS 8 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system has a 15.4 in Flat Panel Display which is a Liquid Crystal Display (LCD), high resolution, and progressive scan (non-interlaced) with Multi-domain Vertical Alignment Technology. This technology allows the brightness of the Liquid Crystal (LC) molecules to appear uniform over a wide variety of viewing angles. The system supports touch interaction using one finger tap, slide and swipe. The Touch-based user interface allows the operator to select functions in the areas highlighted in gray. The operator may change imaging parameters, add customized text, and utilize measurement packages. The resolution is (1280 X 800) pixels. The recordable image area (800 X 600) pixels. The viewing angle is approximately 176 degrees. The energy saving feature enables a screen saver can be set to appear in 10, 20, 30, 40, 50, 60 min or never and can be located in config > display > monitor > screen saver delay Notes No. 8 SIEMENS Healthineers Control panel SIEMENS. Healthineers ... • Simplified user interface O 4 • Traditional alphanumeric keyboard • Direct image optimization keys • 3-inch touch pad 9 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The control panel offers a simplified user interface with limited keys. The system also offers an alphanumeric keyboard and direct access keys for image optimization as well as the touch technology. The Touch Screen offers complimentary actions with the soft keys and virtual keyboard. There is also a 3-inch Touch pad that utilizes gesture controls such as Pinch, Tap and Slide functionality. Notes No. 9 SIEMENS Healthineers Battery SIEMENS. Healthineers ... • One removable lithium-ion battery 00 • Operating time: 1 hour • Recharging time 100%: 3 hours • Operating voltage: 14.4 volts • Capacity: 6.6 amps O • Power: 95 watts -O 10 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system has one removable Lithium-ion battery that is standard with the system. The battery is located on the underside of the system shown here with the large arrow. The small arrow represents the battery release mechanism. Prior to using the battery for the first time, connect the system to a power outlet for at least three hours. The operating time when fully charged is approximately 1 hour. Per the manual guidelines, if the ultrasound system is not used regularly, remove the battery during any lengthy non-use period. Additional batteries may be purchased. Notes No. 10 SIEMENS Healthineers System input / output connector SIEMENS. Healthineers ... • Ethernet • HDMI (for external monitor) • USB 2.0 (4 ports) Ethernet HDMI USB Audio • 3.5 mm stereo audio jack 11 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are several input/output connections on the system. If the system is attached to the Smart cart, the Ethernet and High-Definition Multimedia Interface (HDMI) are more readily accessible on the Smart cart connections. The input/output connections available are: • Four Universal Serial Bus (USB) 2.0 input ports, and the Smart cart has an additional four ports • One Ethernet input port • One HDMI 1.4 output port • One 3.5 mm stereo audio jack Notes No. 11 SIEMENS Healthineers System carrying case SIEMENS. Healthineers ... ACUSON P500 SIEMENS The Maresound Planners 12 Unrestricted © Siemens Healthineers 2022 Speaker Notes: A soft-sided carrying case is included with each system. Notes No. 12 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Explain the General System • Discuss the Cart and Peripheral Options • Discuss Service Features • Review Care and Cleaning SIEMENS 13 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the cart and peripheral options. Notes No. 13 SIEMENS Healthineers Smart cart option SIEMENS. Healthineers ... • Dimensions • 59 cm (w) X 89.2 -109.2 cm (h) X 89.2 cm (d) • Weight 63.8kg / 140 pounds Multi-transducer module option Vari • 20 cm • 4-wheel swivel and lock • Input / Output connectors 14 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Smart cart raises and lowers 20 centimeters using the lever in the front of the cart. It weighs approximately 63.8 kg / 140 pounds. There is a multi-transducer module that supports up to three transducers. There are two shelves for storage of peripherals/supplies and four transducer and gel holders that can be easily removed. There are several input/output connectors on the back of the cart illustrated by the small arrow. The HDMI port supports an External monitor, there is an Ethernet connection and a Direct Current (DC) out port. The cart has 4-wheel swivel: • Castor size: 125 mm • Front castor (2 each): bi-brake system (direction lock and total lock) • Rear castor (2 each): total Lock Notes No. 14 SIEMENS Healthineers Multi-transducer model (MTM) SIEMENS. Healthineers ... • Attaches to the Smart Cart ---- • MTM connector plugs into the system • Enables up to 3 transducers 15 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Multi-transducer Module or (MTM) is optional with purchase of the Smart cart. It ships as a separate item from the cart. The Multi-transducer module (long arrow) plugs into the system transducer connector indicated by the short arrow. Once connected, it allows simultaneous use of up to three transducers indicated by the long arrow. Notes No. 15 SIEMENS Healthineers Simple cart – value offering SIEMENS . Healthineers ... • Maximum physical dimensions • 60.5 cm (W) × 65.9 – 92.1 cm (H) × 53.5 (D) cm • Weight: 18.5 kg • Wheels • Castor size: 125 mm • Front castor (2 each): bi-brake system (direction lock and total lock) • Rear castor (2 each): total Lock 16 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This slide illustrates the features of the Simple cart. This is a great option for institutions that want a cart for the ACUSON P500 Ultrasound system at a reduced cost. Notes No. 16 SIEMENS Healthineers Barcode reader option SIEMENS . Healthineers ... • Allows fast and accurate data input O. • Easy attachment to the USB port • Supports 2D and 1D patient barcodes • Can scan up to 3 individual barcodes 17 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Barcode reader option allows fast and accurate patient information data input. Connect a Siemens Healthineers approved barcode reader directly to a USB port on the system. Originally, barcodes represented data in the widths or lines and the spacing of parallel lines. It supports 1D and 2D patient barcodes: • 1D is linear or one-dimensional lines and spacing • 2D is patterns of squares, dots, hexagons and other geometric patterns within images matrix codes or symbologies It can scan up to three individual barcodes, Patient, Physician, and Sonographer. The Barcode reader inputs the following patient identifying data: Patient First and Last Name, Patient and Physician ID, and Sonographer. Once the barcode is scanned, it will enter the information that has been selected in the configuration menu under Config>Barcode. WARNING: To avoid electrical shock, do not connect the barcode reader to the system when more than two on-board documentation devices are connected to the system. WARNING: Do not stare into the beam of the barcode reader. This action can create a risk for Notes No. 17 SIEMENS Healthineers injury to the user. Notes No. 17 SIEMENS Healthineers DUAL USB Footswitch Option SIEMENS. Healthineers ... Configuration Custom Keys General 1 General 2 Depth and Zoom Knob Direction Custom Keys Display Increase Depth · Clockwise Counter-Clockwise Exam Increase Zoom Clockwise . Counter-Clockwise Soft Keys M&R Report Key Function Text Annotation Savant Elite / USB Body Marker Print/Store 1 Image Store KINEDIE CORPORATION Wireless Network Print/Store 2 Image Store Service Clip Store Clip Store Clip Store Archive Left Pedal Freeze Security Freeze Printer Right Pedal Image Store Barcode User Defined 1 Utility Caliper Stress Echo User Defined 2 Update eSieScan TEQ Update Configure New Key U/D Flip L/R Flip Not Used Rotate -90º (TEE) Rotate +90" (TEE) Save Cancel 18 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The dual-pedal footswitch option is attached to the system via a USB port on the system. There are four connectors located on the cart and four on the system. The footswitch is programmable in the configuration menu under Config>Custom Keys and there are Left Pedal and Right Pedal options. The footswitch is an excellent option when doing procedural exams, for cardiology it may be useful for stress echocardiograms. Notes No. 18 SIEMENS Healthineers Peripherals Option SIEMENS . Healthineers ... PUEDE UNTEN CONTRAST BRIGHT FEED COPY OPEN Up to 2 devices can be Integrated into the System Cart SONY Supported devices: • Mitsubishi USB P95DW b/w printer DIGITAL GRADING PRINTER UP-DESOMD • Sony UP-D898 b/w printer • Mitsubishi USB CP30DW color printer • Sony UP-D25MD color printer aw DVD • TEAC DVD UR-50BD-SK recorder DIGITAL VIDEO RECORDER TEAC UR-5080 19 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Up to two peripheral devices can be integrated into the cart. Support devices include two choices for Black and White (B/W) thermal printer and Color printers. A medical grade Digital Versatile Disc (DVD) recorder is also available. There are additional power connections available on the cart for the peripherals. The printers come with a small sample of paper and it is recommended that paper be ordered prior to installation to ensure the customer has enough during the initial training. Consumables are also available in the Siemens Healthineers price book. Notes No. 19 SIEMENS Healthineers Wireless Data Transfer Option SIEMENS. Healthineers ... Configuration Wireless Wireless Network General 2 Custom Keys Display Wireless On/Off . On O Of Supports connectivity: Exam Soft Keys IP Address Settings Available Networks MER Report DHCP Static IP Address SSID Connection Signal Security Saved Text Annotation 1735 Victori .all Secure No Body Marker IP Address: Wireless DICOM services – Modality worklist, Network Subnet Mask: xfinitywifi UnSecure • Service Clip Store Default Gateway: 1735 Victoria Ext Secure Archive MPPS, storage commitment and store Security MAC Address: CO-E4:34:E7:50:A1 Dream Weaver Secure Printer Barcode Clear Apply Refresh Add Edit Smart Remote Service (SRS) Utility Connect • Stress Echo eSieScan S: Wireless network search completed. Save Cancel 20 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Wireless Data Transfer is a standard feature and utilizes the internal Wireless Fidelity (Wi-Fi) module to enable wireless connectivity between the ultrasound system and the facility’s Local Area Network (LAN). This module provides functionality equivalent to a wired network. It is recommended to use only the 5 GHz frequency bandwidth to reduce potential radio interference from the 2.4 GHz frequency bandwidth. The option supports: • Digital Imaging and Communications in Medicine (DICOM) services - Modality worklist (MWL), Modality Performed Procedure Step (MPPS), storage commitment and store • Smart Remote Service (SRS) - Remote update handling for storage distribution and Teamviewer for remote application support and remote trouble-shooting Notes No. 20 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Explain the General System • Discuss the Cart and Peripheral Options • Discuss Service Features • Review Care and Cleaning SIEMENS 21 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the service features. Notes No. 21 SIEMENS Healthineers Service - Overview of Service Features SIEMENS . Healthineers ... Save Log X • SW downloadable patch Save log data about current system status to a zip file. • Service partition In case you are experiencing a problem or requesting an improvement on system. • Short software installation time please select the area and describe the details. Service problem report tool – CTRL + L [Software Can't access the SRS server .... • Hardware M Network Go Cancel 22 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are several key service features built into the system: The SW downloadable patch is used to reduce system down time. The Customer Service Engineer (CSE) can download the patch from the intranet and then visit the customers site to install the patch rather than wait for it to be shipped. The Service Partition is a dedicated partition for storing recovery images. If a software issue arises, the customer may contact the Customer Care Center and the system can be up and running in approximately 30 min. The Short software reload time is if a software reload is needed, the installation time is approximately 20 minutes. The software is shipped with the system and the customer can work with their service engineer to reload it remotely. The Service problem report tool is the ability for the customer to save error logs to report incidents. The customer may simply press Ctrl + L and a pop-up window will appear where the customer may fill in details for the Software, Hardware or Network. Notes No. 22 SIEMENS Healthineers Probe Saver SIEMENS . Healthineers .. System Serial Number : PP4294 ACUSON SIEMENS 02/0 2/2016 system Serial Number : PP4294 ACUSON 83703/ 2016 09- 19:30 ACUSON SIEMENS System Serial Number : PP4294 03/03/2016 09-19:53 Small Parts Small Parts Small Parts Tx Power 100% Tx Power 100% Tx Power 1.00% MI 1.20 MI 1.20 MI 0.18 TIB 0.3 TIB 0.3 TIB <0.1 SC 2 DTCE High SC 2 SC 2 Dyn R 80 dB DTCE High DTCE High THI 8.0 MHZ Dyn R 80 dB Dyn R 80 dB THI 8.0 MHZ THI 8.0 MHZ 0 dB 28 fps 0 dB 0 dB 28 fps 28 fps 3.5 cm 3.5 cm 23 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The systems has a feature called Probe Saver, which reduces transmit power automatically when a probe is idle for a set period of time. Once the transducer is placed on the skin and tissue is recognized, the power automatically adjusts to normal scanning. This feature is not enabled when the system ships from the factory. This slide demonstrates the Probe Saver feature. Notice, the first image on the left, illustrates active scanning. The middle image illustrates no scanning mode and the third image illustrates the decreased transducer power. This is especially useful for the ICE transducer or during interventional procures where the transducer is left idle for some time. This feature will need to be set-up in the Configuration Menu: Config > General 2 >Transmit Power. You can turn it off or chose from 5 secs, 1, 3, 5, or 10 mins Notes No. 23 SIEMENS Healthineers What is eSieLink TM Remote Assistance? SIEMENS . Healthineers ... Siemens REMOTE Service syngo Remote syngo Remote Remote Assist (sRA) Trainer (sRT) Diagnostics Pre-clarification Provides User Services System Services Real-time remote Enable Enhance training and applications eSieLink TM Technology support (Ultrasound implementation of TeamViewer) Software: TeamViewer Hardware*: eSieLink Accessories * Webcam, headset, mounting device 24 Unrestricted © Siemens Healthineers 2022 Speaker Notes: eSieLink TM Remote Assistance Technology provides Real-time remote training and applications support. eSie Link remote assistance not only enables user services, e.g. syngo Remote Assist, syngo Remote Trainer, but also enhances Siemens Remote Service. To enjoy the full value of eSieLink remote assist, the ultrasound system must be connected to SRS. Notes No. 24 SIEMENS Healthineers eSieLink TM Remote Assistance Accessories SIEMENS. Healthineers ... Logitech C930E Jabra Evolve 30UC Webcam mounting strap LowNach ::::::: ... ::: :. 25 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The eSieLink remote assistance accessories are the Logitech C930E webcam, Jabra Evolve 30UC headset and the webcam mounting strap. These are optional items to support this technology. Notes No. 25 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Explain the General System • Discuss the Cart and Peripheral Options • Discuss Service Features • Review Care and Cleaning SIEMENS 26 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will review the care and cleaning of the system. Notes No. 26 SIEMENS Healthineers Care and Cleaning SIEMENS. Healthineers ... General System Cleaning and Disinfecting Inspect the Power and transducer cords To see the latest Disinfecting information please visit: Verify transducers are clean and free of gel https://www.siemens-healthineers.com/ultrasound/ultrasound- transducer-catalog Verify the control panel, touch pad and • touch screen are clean and free of gel or Use only approved cleaners listed in the manual • Do not use spray or aerosol cleaners on the system or transducers other contaminants • Use only approved disinfecting wipes • The Touch Screen can be cleaned with the approved disinfecting wipes Check that the data field is accurate • Always apply a sterile sheath during procedures requiring sterility • Carefully follow the disinfectant manufacturer's instructions for disinfection or high-level disinfection. 27 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The safety and care section of the manual should be reviewed carefully prior to performing an ultrasound examination. The manual provides detailed instructions as well as the approved disinfecting wipes and solutions. Please Note: The system should be powered off and the power plug removed when cleaning the system. The topics listed are just a few of the requirements for care and cleaning. This may seem like basic information, but many non-traditional users may utilize this system for scanning, so it is important to review this for all new installations or anytime the customer is using the system alone regardless of the institution or medical facility. From the manual: Daily Checklist • If your system's power cord is frayed, split or shows signs of wear, contact your Siemens Healthineers service representative for a power cord replacement • Visually inspect the Electrocardiogram (ECG) connector and the cable. Do not use the ECG function if the connector or cable is damaged or broken • Verify that the touchpad, Depth Gain Compensation (DGC) slide controls, and other controls on the control panel are clean and free from gel or other contaminants Notes No. 27 SIEMENS Healthineers Please Note: Once the system is powered on, visually check the on-screen displays and lighting. Notes No. 27 SIEMENS Healthineers Transducer disinfectant list SIEMENS. Healthineers ... 2 2 Revital Ox RESERT HL D EPR with EPR with HB 1000 MetriCide NanoNebula NanoNebula nt* nt * CIDEX CIDEX OPA Gigasept FF OPA Plus Sani-Cloth Sani-Cloth Super Sani-Cloth System Sonex-HL* Sonex-HL* (new) *TD-5 *TD-8 *Trophon *Trophon *Trophon2 *Trophon2 ANIOXYDE AF3 Wipes Tristel Trio with with 5VT √ √ √ √ √ NA NA NA NA √ √ √ NA NA NA NA CH5-2 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ VF10-5 NA √ √ NA NA √ √ √ √ NA NA NA √ √ √ √ VF13-5 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ VF16-5 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ L10-5v NA √ √ NA NA √ NA √ √ NA NA NA NA NA NA NA EC9-4 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ P4-2 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ 11M3 NA √ √ √ NA √ NA NA √ NA NA NA √ √ √ √ 18H5 NA √ √ NA NA √ √ √ NA NA NA NA √ √ √ √ P8-4 NA √ √ √ NA √ √ √ √ NA NA NA √ √ √ √ CW2 NA √ √ √ NA NA √ √ √ NA NA NA √ √ √ √ CW5 NA √ √ √ NA NA √ √ √ NA NA NA √ √ √ √ ✓ approved NA = not approved / not tested * = automated disinfection systems = 28 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The transducer disinfectant list has been updated to be compliant with the latest Covid-19 regulations. Notes No. 28 SIEMENS Healthineers Trademark and Disclaimers • AcuNav, Advanced SieClear, eSieLink, eSie Measure and TEQ are registered trademarks of Siemens Medical Solutions USA, Inc. • Soundstar is a registered trademark of Biosense Webster • Windows 10 is a registered trademark of Microsoft Corporation in the U.S.A 29 Unrestricted © Siemens Healthineers 2022 Speaker Notes: No Speaker Notes Notes No. 29 SIEMENS Healthineers Thank you! SIEMENS. Healthineers ... Questions? 30 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Questions? Notes No. 30
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- POC
- Point of Care
- Trauma
- FAST
- eFAST
- BLUE
- FOCUS