ACUSON P500 Ultrasound System 3.0 eSie Scan workflow Protocols Presentation
This job aid provides information using the eSie Scan workflow protocols on the ACUSON P500 system at 3.0 software.
SIEMENS Healthineers SIEMENS Healthineers .. ACUSON P500 Ultrasound System eSieScan TM Workflow Protocols 3.0 Software Release 1 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This is a presentation provides and overview of the ACUSON P500 Ultrasound System set-up and use of eSieScan TM Workflow Protocols. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Define Protocols • Summarize eSieScan workflow protocols benefits • Build eSieScan workflow protocols • Utilize eSieScan workflow protocols SIEMENS :.::::::::::::::::::: 2 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here are the objectives of this presentation. We will start with defining the protocols. Notes No. 2 SIEMENS Healthineers Defining Protocols SIEMENS. Healthineers ... SIEMENS A protocol is a guided clinical workflow which is based on a pre- defined checklist SIEMENS :.::::::::::::::::::: 3 Unrestricted © Siemens Healthineers 2022 Speaker Notes: A protocol is a guided clinical workflow which is based on a pre-defined checklist. Notes No. 3 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Define Protocols • Summarize eSieScan workflow protocols benefits • Build eSieScan workflow protocols • Utilize eSieScan workflow protocols SIEMENS :.::::::::::::::::::: 4 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the benefits of the eSieScan workflow protocols. Notes No. 4 SIEMENS Healthineers eSieScan Workflow Protocols Benefits SIEMENS . Healthineers ... P4-2 Cardiac Routine Echo Tx Power 100% MI 0.74 PLAX • Guides new users TIS 0.9 20 TIB 0.9 PLAX LV 2.2 MHZ PLAX 3541 Hz AVILA 2D Flow Med 61.3 AOd @Sie Scan • Standardizes exams 0 dB LAs diam 14 fps PLAX Fr 94 FLAX LV 20 DIS 68 bpm Diastole • Automation Systole PLAX 20 PLAX AV MV Zoom PLAX • Flexibility when needed Color PLAX MY C PLAX Color PLAX MVC| CRIVIT 4KB F194 Pause Edit 5 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here are several benefits to using eSieScan workflow protocols during an exam. 1. Guides new users (new to the system or new employees) • Learn system faster • Learn standardized protocols faster • Fewer keystrokes • Focus on the patient/exam instead of system controls • Reduce call backs for missed Views 2. Standardizes exams • Ensures required diagnostic information is acquired • Streamlines the accreditation process • Consistency in export order/reading order 3. Automation • Mode Progression • Fewer keystrokes • Reduce call backs for missing Views • Annotation • Fewer keystrokes • Correctly labeled images • Body markers • Reduce time manipulating Body Markers • Correct transducer marker location • Measurements • Required measurements completed • Stores to Report – less searching during dictation Notes No. 5 SIEMENS Healthineers eSieScan Workflow Protocols Benefits SIEMENS . Healthineers ... P4-2 Cardiac Routine Echo Tx Power 100% MI 0.74 PLAX 20 • Guides new users TIS 0.9 TIB 0.9 PLAX LV 2.2 MHZ PLAX 3541 Hz AVILA 2D • Standardizes exams Flow Med 61.3 AOd @Sie Scan 0 dB LAs diam 14 fps PLAX Fr 94 FLAX LV 20 DIS 68 bpm Diastole • Automation Systole PLAX 20 PLAX AV MV Zoom Flexibility when needed PLAX • Color PLAX MY C PLAX Color PLAX MVC| CRIVIT 4KB F194 Pause Edit 6 Unrestricted © Siemens Healthineers 2022 Speaker Notes: 4. Flexibility when needed • Manual Advancement, Skip Views • Adapt exam to fetal movements, bowel gas, missing organ • Less time waiting/struggling for “just the right” View • Variations in anatomy - assess other areas first • Pause and Resume (within or at the end of exam) • Evaluate pathology • Change Protocols during an exam • Incidental findings • Acquisition order and export order can be different • Easier adoption for new users • Customizable to meet specific needs • Adaptable to differing preferences Notes No. 6 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... SIEMENS • Define Protocols • Summarize eSieScan workflow protocols benefits • Build eSieScan workflow protocols • Utilize eSieScan workflow protocols SIEMENS 7 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss how to build a protocol. Notes No. 7 SIEMENS Healthineers Factory Default Protocol SIEMENS . Healthineers ... eSieScar • One factory default is Configuration Protocole General 1 available. It may serve as a General 2 Routine Echo Protocol Name Custom Keys template or as an example to Display Routine Echo Exam Soft Keys Rename refer to when customizing a M&R Report Automatically ends when all views completed. Text Annotation protocol Body Marker -At End Protocol- Wireless Remain in acquisition Network Service O Enter Review Clip Store Archive Enter Report Authorization Printer Barcode Utility Stress Echo Add Protocol eSieScan Add View Copy Default Delete Export Import Save Cancel 8 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Left panel control has a drop-down menu of the eSieScan protocol that is available. There is one factory default available on the system. It may serve as template or as an example to refer to when customizing a protocol. Notes No. 8 SIEMENS Healthineers Creating an eSieScan Workflow Protocol SIEMENS . Healthineers ... 1. Select Configuration tab Configuration SieScar General 1 Protocols General 2 Routine Echo Protocol Name Custom Keys 2. Select eSieScan Display Routine Echo Exam Soft Key Rename M&R Report Automatically ends when all views completed. Text Annotation 3. Select Add Protocol Body Marker -At End Protocol- Wireless Remain in acquisition Network Service O Enter Review Clip Store Enter Report 4. Select Import / Export Archive Authorization Printer Barcode eSieScan Add Protocol Add View Copy Default Delete Export Import Save Cancel 9 Unrestricted © Siemens Healthineers 2022 Speaker Notes: eSieScan protocols are available only on the Adult Cardiac exam. To create or modify the existing factory protocol, select Configuration > eSieScan > Add protocol and modify as needed. Protocols and views can be viewed, created, copied, deleted or moved. Notes No. 9 SIEMENS Healthineers Creating an eSieScan Workflow Protocol SIEMENS. Healthineers ... 5. Enter a new protocol name, eSieScan Protocols select Rename to confirm + Routine Echo Protocol Name New Echo Protocol New Echo Protocol Rename 6. Select the last step of the Automatically ends when all views completed. protocol, the options are: At End Protocol . Remain in acquisition Remain in acquisition, Enter Enter Review Enter Report Review or Enter Report V Add Protocol 7. Select Add View Add View Copy Default Delete Export Import Save Cancel 10 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, enter a new protocol name, select Rename to confirm. Select the last step of the protocol where the options are: Remain in acquisition, Enter Review or Enter Report. Select Add View. Notes No. 10 SIEMENS Healthineers Creating an eSieScan Workflow Protocol SIEMENS . Healthineers ... 8. Type in desired view name, eSieScan Protocols select Rename to confirm Routine Echo PLAY View Text & Body Marker E New Echo Protocol PLAX 20 View PLAX Rename 9. Select desired Automatic Automatic Mode Change C 2D Mode Change O Color O CDE O DTE Color DT O PW CCW COM-Mode PW DTI O Dual Split Measurements Label1 Label2 Label3 10. Repeat with each view Exam Label None Imaging Mode Add Protocol 11. Select Save Package Add View Copy Press Measure to resume Delete Export mport Save Cancel 11 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Type in the desired view name and select Rename to confirm. Select the desired Automatic Mode Change and repeat this with each view and select Save. Notes No. 11 SIEMENS Healthineers Integrate eSie Measure TM Workflow Acceleration Package into SIEMENS . Healthineers ... Protocols eSieScan 1. Select Measurement Label for Protocols Routine Echo eSieScan integration – select E New Echo Protocol PLAX Teichholz View| Text & Body Marker | PLAX 20 PLAX AOV Color PLAX Teichholz Cardiac in Exam drop-down menu PLAX Teichholz Rename Automatic Mode Change . Color C CDE C DTE C Color DTI C PW CM-Mode C PW DTI 2. Select Imaging Mode (2D, M, or C Dual C Split Measurements PW), the corresponding Label1 Label2 Label3 Exam Label Cardiac measurement package will be Imaging Mode Add Protoco 2D v available to select in the Package Package Add View Mitral Valve drop-down menu Copy AVILA Delete Aortic Valve Pulmonary Valve Export Import Single Plane Teichholz(2D) Bi-Plane Simpson BP Save Cancel Simpson SP Mod.Simpson Bullet Cubed(2D) THI Clarify VE DICE Gibson(2D) bitiHertz 12 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To build a protocol, select the Cardiac exam and then select Add Protocol and it will load View1. To rename the view, type in desired name in the space provided. Under imaging mode, select the next mode to change for that view. If the customer wanted to have a mode change, the options are given below the header Automatic Mode Change. Automatic Mode Change options: 2D, Color, CDE, DTE, Color DTI, PW, CW, M-MODE, PW DTI, Dual and Split. The measurement options are Label1, Label2, and Label 3 which selects the first, second and third measurement labels. Notes No. 12 SIEMENS Healthineers Integrate Text & Body Marker into eSieScan Protocol SIEMENS . Healthineers ... 1. Select Text and Body Marker eSieScan tab and Type in desire text Protocols 4 Routine Echo View Text & Body Marker PLAX PLAX Text Annotation PLAX 2D PLAX PLAX AV MV Zoom PLAX PLAX AV MV Zoom PLAX Body Marker 2. Customize the Probe location PLAX RVIT RVIT RVIT PSAX AV PSAX AV PSAX IAS 3. Select List to view Body Marker PSAX TV PLAXAVIMV 200 PSAX TV RVOT BodyMarker RVOT Options Cardiac RVOT PV Exam PSAX LV BASE List PSAX LV MID PAP PSAX APEX Transducer Marker Apical 4ch Add Protocol Location Angle Apical 4ch 4. Select Angle to modify Apical 4ch Apical 4ch dd View Apical 4ch Apical 4ch Copy -5 +5 transducer position Apical 5ch -- Apical 5ch Delete Apical 2ch Export Import Save Cancel 13 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To integrate text and the body marker into the eSieScan protocol, select the Text & Body Marker tab and then type in the desired Text Annotation. Customize the Location of the transducer by placing the cursor in the desired location. Select List to view Body Marker Options and select Angle to modify the transducer position. Notes No. 13 SIEMENS Healthineers Modifying an eSieScan Protocol SIEMENS. Healthineers ... 1. Highlight the protocol Configuration eSieScan General 1 Protocols General 2 Routine Echo Protocol Name Custom Keys Routine Echo 2. Select Copy Display Exam Soft Keys Rename M&R Report Automatically ends when all views completed. Text Annotation 3. Rename the protocol Body Marker At End Protocol- Remain in acquisition Networ . Enter Review Clip Store 4. Add, edit, or delete steps, modes, Archive Enter Report Authorization Printer settings and measurements Barcode Utility Stress Echo eSieScan Add Protocol Add Viev 5. Select Save Copy Default Export Import Save Cancel 14 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To modify an eSieScan protocol, highlight the protocol you wish to modify and then select Copy. Rename the protocol and Add, edit, or delete steps, modes, settings and measurements as desired then select Save. Notes No. 14 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Define Protocols • Summarize eSieScan workflow protocols benefits • Build eSieScan workflow protocols • Utilize eSieScan workflow protocols SIEMENS :.::::::::::::::::::: 15 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss how to utilize eSieScan workflow protocols. Notes No. 15 SIEMENS Healthineers Utilize eSieScan Workflow Protocols SIEMENS. Healthineers .. 1. Select Cardiac from the Exam 2D System Serial Number : 390102 ACUSON SIEMENS 10/01/2017 15:59:03 drop-down menu P4-2 Cardiac Physio Settings Stress Tx Power 100% Echo MI 0.86 TIS 0.8 TIB 0.8 eSieScan DTCE Low 2. Select eSieScan from the Left Dyn R 75 dB THI 3.6 MHZ 0 dB Panel Control Biopsy Visual 51 fps 0 bpm << Steer Steer >> LUR Flip LWD Flip Full Size Trapezoid 16 cm Dual Split DTI RVS THI DTCE Edge Dyn R MultiHertz Focus Focus Nu ... On Position Low 3.6 MHZ Persist Focus Posi .... 75 dB 16 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To utilize the protocols, select Cardiac from the Exam drop-down menu and then select eSieScan. Notes No. 16 SIEMENS Healthineers Utilize eSieScan Workflow Protocols SIEMENS. Healthineers ... 3. Select the desired workflow protocol SEMENS from the drop-down menu 4. Select the first view, a blue highlight box will highlight the view 5. Begin acquiring images SIEMENS .:::::: ::::::: 17 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, select the desired workflow protocol from the drop-down menu and select the first view, a blue box will highlight the view. Then, begin acquiring images. Notes No. 17 SIEMENS Healthineers Utilize eSieScan Workflow Protocols Tips SIEMENS. Healthineers ... • To skip a view, use the cursor or touch the SIEMENS view to go to the desired view • Once the view has been acquired, the box around the view will be grayed out • The box around the view will remain white until that view has been acquired and saved SIEMENS • Various eSieScan protocol functions .:::::: ::::::: available on-the-fly 18 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To skip a view, use the cursor or touch the view to go to the desired view. Once the view has been acquired, the box around the view will be greyed out. The box around the view will remain white until that view has been acquired and saved. There are various eSieScan protocol functions available on-the-fly: Pause, Edit, Delete View, Print, Clear, Delete, Copy View, Rename View and Exit. Notes No. 18 SIEMENS Healthineers Trademark and Disclaimers SIEMENS. Healthineers ... • eSie Measure and eSieScan Workflow SIEMENS Protocols are registered trademarks of Siemens Medical Solutions USA, Inc. SIEMENS .:::::: ::::::: 19 Unrestricted © Siemens Healthineers 2022 Speaker Notes: No Speaker Notes. Notes No. 19 SIEMENS Healthineers Thank you! SIEMENS. Healthineers ... Questions? 20 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Questions? Notes No. 20
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- POC
- Point of Care
- Trauma
- FAST
- eFAST
- BLUE
- FOCUS