ACUSON P500 Ultrasound System 3.0 Control Panel and Touch Screen Presentation
This job aid provides information using the Control Panel and Touch Screen on the ACUSON P500 system at 3.0 software.
SIEMENS Healthineers SIEMENS Healthineers ... ACUSON P500 Ultrasound System Control Panel and Touch Screen 3.0 Software Release 1 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This presentation provides an overview of the Control Panel and Touch Screen of the ACUSON P500 ultrasound system. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Review the Control Panel • Discuss the Alphanumeric Keyboard • Identify the Touch Screen functionality =- • Explain the Touch Pad functionality • Explain the Control Panel Lighting ...................................................................................... SIEMENS 2 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here are the objectives of this presentation starting with reviewing the Control Panel. Notes No. 2 SIEMENS Healthineers User Interface SIEMENS . Healthineers ... 20 Systeme Serial Number : PP3018 ACURSION New Patient VF 13-45 D New Patient Patient Demographics Small Parts Patient ID ECG A ECG Tx Power 100% @ Edit Patient Data Last Name MI 0.71 First Name Date of Birth DD / MM / YYYY Age TIS <0.1 Saf Gender C Male female . Other Resp TIB <0,1 Height ESA ASC 2 DTCE High Weight mmlig Dyn R76 6B Exam THI B.S MHZ Transducer VF13-5 secession No. 60 fps Exam Small Parts Indication Medical Information Additional info Order Information Performing MD Referring MD Sonographer Return OK Cancel DICE DICE Touch-Based U Point and Click 3 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system was designed using two approaches depending on the function and user preference. The first approach is the Touch-based user interface. This interface allows the operator to select functions in the areas highlighted in gray. The operator may change imaging parameters, add customized text, and utilize measurement packages. The second approach is the traditional point and click method. For some functions, like entering patient information, it may be easier to use the traditional point and click method. Notes No. 3 SIEMENS Healthineers Control Panel Design SIEMENS . Healthineers ... Workflow Driven Approach 4 4 4 1 1. Registration 4 2. Acquisition 3. Documentation O 4. Review and Report 4 2 3 Freeze 4 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Control Panel offers a simplified user interface using a workflow driven approach. This approach focuses on the 4 main areas of performing an exam: registration, acquisition, documentation and the review/report mode. 1. Registration: These keys are grouped to the left of the keyboard. To perform an exam, a patient must first be registered. Select the Exam key for the appropriate exam type. This is where the exams supported by the selected transducer will be displayed. 2. Acquisition: Once the application and transducer are selected, the system automatically loads the preset parameters. The acquisition keys are utilized for selecting / changing modes, depths, optimizing the Doppler scale, etc. The image optimization keys are secondary acquisition keys and are located on the top row of the control panel. 3. Documentation: The Print and Store selection keys are grouped next to the Freeze key. 4. Review and Report: Once the exam is completed, the operator may select the Review and or Report key to review images and the report. Notes No. 4 SIEMENS Healthineers Control Panel SIEMENS. Healthineers ... Soft Keys Power On / Off 4 A IS o Workflow = O Keys G ..... DGC New Screen T 5 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The soft keys are located at the top of the control panel. The functions for the keys will change depending upon the mode that is being performed. For example, if measuring, the soft key options will offer measurement options. The soft keys may also be controlled by the Touch Screen. The Power On / Off key powers the system on or off. The workflow keys are located below the Power On / Off key. The workflow keys are: Registration, Exam, Review, Report, Browser, Configuration and the Help key. The (Depth Gain Compensation) DGC is located to the far right. Notes No. 5 SIEMENS Healthineers Control Panel SIEMENS. Healthineers ... Major Modes Depth / Zoom ........ Doppler Measure ........ : ........... Controls Angle Depth/Zo00 and ... Clip Store 4 Scale Baseline Measure Clip Store .... User UD 2 Piet Print ...... Defined ....... and Store Touch Pad Freeze 6 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The major mode keys are located in the center of the Control Panel. The keys are grouped with the 2D controls including TEQ technology and Depth / Zoom on the right. The Doppler controls are located on the left side and include Baseline, Scale, Angle and Invert. Two User Defined keys are on the bottom left of the Control Panel. These can be set up in the configuration menu and can be programmed for multiple functions. To customize the User Defined keys, select Config > Custom Keys > User Defined 1 or User Defined 2. In the center of the Control Panel is the Touch Pad. The Freeze key is located to the right of the Touch Pad. The bottom right side of the panel are the documentation keys where the operator may Print, Store, Clip Store or activate the measurement screen. Notes No. 6 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Review the Control Panel • Discuss the Alphanumeric Keyboard • Identify the Touch Screen functionality =- • Explain the Touch Pad functionality • Explain the Control Panel Lighting ...................................................................................... SIEMENS 7 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the Alphanumeric Keyboard. Notes No. 7 SIEMENS Healthineers Alphanumeric Keyboard SIEMENS. Healthineers ... @ 2 # € % 2 V & W 5 O a von 6 7 u W 8 19 O B - W CE N P T Y A O C: O m O Q P A S D F G 5 ce B K L I ... a e O X C V < A B N 0 M ? N ? Ctrl New Alt Clear Screen T ..... New Patient Arrow Special Characters Clear Screen Text Body Markers Unrestricted © Siemens Healthineers 2022 8 Speaker Notes: The alphanumeric keyboard is a traditional method for typing in this environment. The New key closes the study, depending on the system configuration. It allows the operator to bypass the patient registration page and begin scanning which is useful in the Emergency department. The Arrow key displays an arrow on the image screen to point out anatomy or areas of interest on the image. The Alt key provides access to special characters required for some languages when used in combination with the alphanumeric keys. The special characters are printed at the top of the alphanumeric keys. The Clear Screen key will clear any measurements, annotations or body markers on the screen. The Text key activates the annotation function. The Body Markers key activates the body marker function and displays the default body marker for the active exam. Notes No. 8 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Review the Control Panel • Discuss the Alphanumeric Keyboard • Identify the Touch Screen functionality =- • Explain the Touch Pad functionality • Explain the Control Panel Lighting ...................................................................................... SIEMENS 9 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the Touch Screen functionality. Notes No. 9 SIEMENS Healthineers Touch Screen SIEMENS. Healthineers ... SIEMENS • Supports Touch Interaction • Select Slide or Swipe functionality • Customizable to User-preference =- • Programmable Screen Saver ...................................................................................... SIEMENS 10 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system has a 15.4 in. Flat Panel Liquid Crystal Display (LCD), high resolution, and progressive scan (non-interlaced) with Multi-domain Vertical Alignment Technology. This technology allows the brightness of the LC molecules to appear uniform over a wide variety of viewing angles. The system supports touch interaction – one finger select, slide and swipe. The Touch-Based user interface allows the operator to select functions in the areas highlighted in gray. The operator may: change imaging parameters, add customized text, and utilize measurement packages. During real-time imaging, the screen displays clinical images, operating parameters, patient data, and control commands. The user can customize many of the screen elements to accommodate your preferences and workflow. Note: During real-time imaging, the part of the screen that displays the image does not support touch technology. During review, the entire screen supports touch technology. The screen saver feature automatically freezes the system and replaces the active display with a screen saver after the system has been inactive for a specified number of minutes. Exit the active screen saver by selecting any key, adjusting any control, or selecting the Touch Pad. Notes No. 10 SIEMENS Healthineers Touch Screen Functionality SIEMENS . Healthineers ... Action Gesture Imaging Non-imaging Priority One-finger select Priority of selected Touch Screen gestures not Primary Usage imaging mode, Control available during non-imaging feature, label, text, etc. applications Paging of soft-key menu One-finger drag Scroll (label menu control Touch Screen gestures not Primary Usage feature, floating menu, available during non-imaging thumbnail panel) applications Cine/Play position One-finger flick Quick scrolling of options Touch Screen gestures not Primary Usage (quick-drag gesture) available during non-imaging applications Author | Department 11 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are three primary gestures that are utilized on the Touch Screen: 1. One-finger select - Use this when changing a parameter, setting priority to a mode or adding text. 2. One-finger drag - Use this when scrolling through a menu or reviewing thumbnails or activating cine/Play. 3. One-finger flick - Use this when needing to quickly scroll through options. Notes No. 11 SIEMENS Healthineers Touch Screen – Left Panel Controls SIEMENS . Healthineers ... 2D C 20 C SIEMENS CHS-2 Abdomen Physio Tx Power 100% Settings MI 1.01 TIS 0.6 TIB 0.6 2.7 MHZ 2166 Hz Flow Med 7 4B & fps Fr 182 Cine Rate Color Display Dual Reset Markers Cine Rate Next Frame Map Color Dalojay Dual CW 12 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The customizable parameters in the Left Panel Control change depending on the mode the operator is in and can be activated with the cursor or by Touch Control. Notes No. 12 SIEMENS Healthineers Touch Screen – Soft Keys and Touch Pad SIEMENS . Healthineers .. 20 C SIEMENT CH8-2 Abdomen Tx Power 100% MI 1.01 TIS 0.6 TIB 0.6 2.7 MHZ 2166 H2 Flow Med 7 de 6 fps Fr 182 Cine Rate Set Start ... Previous Set End M ... Frame Next Frame Map Priority Play/Pause Play/Pause H 13 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The customizable soft key menu may be activated either with the Soft key controls on the keyboard or via touch by utilizing the Touch Control. Notes No. 13 SIEMENS Healthineers Touch Screen Layout SIEMENS . Healthineers ... 20 System Serial Number : PP3018 ACUSON SIEMENS 02/2015 14:27-23 Mode Indicator Small Parts Physio Tx Power 100% Settings MI 0.71 0.1 <0.1 System Status ASC 2 DICE High Den R 75 dB Biopsy THI 8.9 MHZ Transducer 0 B 60 fps Orientation << Steer Steer >> Depth Markers L/R Flip W/D Flip Imaging ......... .. ..... Parameters Depth Display Dual Delete eSielmage ,.. Dyn R Edge Map Presets DICE MultiHertz THI FOCUS Position 8.9 MHZ Persist Tint Gen High On Tx Power Focus Nu. 14 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Touch Screen layout contains the following parameters: Patient Banner: Displays patient information and the system date and time. Mode indicator: Displays the activated operating modes and highlights the mode that currently has priority. Select the required mode indicator to change the active priority mode. Transducer orientation indicator is represented by the ACUSON gold “a”. Imaging parameters: Displays a list of imaging settings for the active imaging mode. When a specific parameter is changed, it will highlight in yellow momentarily. System status bar: Displays information about the system, for example, wireless connectivity and battery life. Depth markers: Shows the depth in centimeter increments. Depth Display: Shows current depth selected. Notes No. 14 SIEMENS Healthineers Touch Screen Functionality SIEMENS . Healthineers ... 20 System Serial Number : PP3018 ACUSON SEM5015 14 27-29 VF 13-5 Small Parts Tx Power 100% Setting MI 0.71 TIS <0.1 DTCE High Biopsy 60 fps << Stoor| Steer >> L/R Flip WD Flip Trapezoid Dual 4 cm esteimage- Dyn Edge map DICE Persist High MultiHertz 8,9 Mitz Tx Power Left Soft Key Right Soft Key Left Panel Controls Menu Left Soft Keys Touch Pad Right Soft Keys Thumbnails Menu 15 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Touch Screen contains the following functionality parameters: Left Panel Controls: The functions in the Left Panel Control vary depending on the operator’s current mode. These controls typically perform an action, such as: steering the image, using dual or accessing a measurement package. During the measurement function, the left panel displays the measurement labels. To activate a function, select it by utilizing the Touch Screen or using the arrow. To deactivate, select the function again. Thumbnail panel: The Thumbnail panel displays reference images of stored images and clips. Swipe upwards or downwards on the thumbnail panel to view the images. During Review, double select a thumbnail to display the image in a full screen format. To add images to a report, select the thumbnail. Left and Right Soft keys: The soft keys are customizable and vary depending on the mode the operator is in. Select the desired soft key on the Control Panel to change the setting for the imaging parameter. Both right and left soft keys function in the same manner. These are programmable in the configuration menu. Notes No. 15 SIEMENS Healthineers Left and Right Soft key Menus: Are additional parameters available that can be assigned to the soft keys. Both Right and Left Menus function in the same manner. They are programmable in the configuration menu. Notes No. 15 SIEMENS Healthineers Touch Screen functionality SIEMENS . Healthineers ... 20 System Serial Number : PP3008 ACTION SINON0015 14:02-25 Review 1291991 EC9-4 VF 10-5 OYN CV Tx Power 100% Tx Power 100% MI 0.83 MI 0.60 TIS 0 A TIS <0.1 TIB 0 4 TIB <0.1 ASC 1 6.3 MHZ DTOE Med 4340 Hz Dyn Kib de Gate 2.0 mm THIS 4 MHZ 6 de 2 dE 15 fps 29 fp5 Markers One Rate imaging Nonet Frame DICE Dyn R Layout Full Screen Point Export Med Map Time 20433 Frozen Image Review Mode 16 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Soft Key controls change depending upon the mode. When in a frozen image, the screen displays the functions available in that mode. For example, Cine functionality and post-processing features. When in Review, some of options are dithered out or grey and not available. This provides the user only the keys they can access, making it easier to use. Notes No. 16 SIEMENS Healthineers Touch Screen functionality SIEMENS . Healthineers ... 20 CW System Serial Paarsbee : P 20 C PW System Serial Number : PP2308 ACUSON VF 10-5 CH5-2 CV Tx Power 100% Abdomen Tx Power 100% CCA Pros MI 0.58 MI 0.80 TIS <0.1 TIB <0.1 TI5 0.0 CCA MIA 5.3 MHz TIB 2.7 4340 Hz 2.7 MHZ Gate 2.0 mm 3951 Hz CCA Dist -14 dB Gate 4.0 mm 13 fps 6 dB 0 fps ICA PIOR ICA MIS KA DAT ICA VAS PG2 = 0.1mmHg req2 + 0.56KHz V2 - 24.7cm/s PG2 =0.2mmHg Freq2 = 6.68KHz Velocity PS " ED Delete PI Manual Velocity PSEED| Delete All Delete Measurement Package Standard Measurement 17 Unrestricted © Siemens Healthineers 2022 Speaker Notes: When in a Measurement package, the Left Panel Control Keys show the measurements associated with the package. When using a direct measurement such as a PI, RI or Velocity, the menu only displays the choices available. The keys are designed around the workflow needed for that specific task. Notes No. 17 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Review the Control Panel • Discuss the Alphanumeric Keyboard • Identify the Touch Screen functionality =- • Explain the Touch Pad functionality • Explain the Control Panel Lighting ...................................................................................... SIEMENS 18 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the Touch Pad functionality. Notes No. 18 SIEMENS Healthineers Touch Pad Layout SIEMENS. Healthineers ... • The Touch Pad and keys provide access to both imaging and non-imaging functionality UPDATE • Navigating patient registration form and configuration screens TOUCH PAD SET SET • During imaging, the Touch Pad performs positioning and placement functions • Position a region of interest or anchor measurement calipers 19 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Touch Pad and Touch Pad keys provide access to both imaging and non-imaging functionality. For example, the Touch Pad is utilized for navigating the patient registration form and the configuration screens. During imaging, the Touch Pad performs positioning and placement functions. For example, position a region of interest or anchor measurement calipers. During non-imaging functions, the Touch Pad works like a mouse on a personal computer. The Update key performs an assigned function depending on the current task. For example, the update function during Doppler imaging. Both left and right Set Keys perform the same function for the current task. For example, to play a clip or position the field of view. Notes No. 19 SIEMENS Healthineers Touch Pad Functionality SIEMENS. Healthineers ... Action Gesture Imaging Non-imaging Priority Multi-touch Gestures Gate size N/A Secondary Usage Two-finger scale 2D size (pinch-spread) Color ROI One-finger Gestures Cursor position Cursor position Primary Usage One-finger drag Measurement marker Cine/Play position Mark position One-Finger Gestures Activates the function assigned N/A Secondary Usage One-finger select to Touch Pad keys Activates the selected button on a form Positions a caliper 20 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are three primary gestures that are used on the Touch Pad and works similarly to a tablet device. Pinching and spreading with two fingers sizes an on-screen object. For example, the region of interest and the Doppler gate. The One Finger drag is performed by sliding one finger horizontally or vertically across the Touch Pad. This positions an on-screen object, for example, the M-mode cursor or a measurement marker. It will also scroll in a list, for example, in the patient report. Selecting the Touch Pad activates the function assigned to the left and right Touch Pad keys. It also activates the selected button on a form and positions a caliper during the measurement function. Notes No. 20 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... SIEMENS • Review the Control Panel • Discuss the Alphanumeric Keyboard • Identify the Touch Screen functionality =- • Explain the Touch Pad Functionality • Explain the Control Panel Lighting ...................................................................................... SIEMENS 21 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Finally, we will discuss the Touch Pad functionality and Control Panel lighting. Notes No. 21 SIEMENS Healthineers Control Panel Lighting SIEMENS. Healthineers ... Illuminated Keys: • Power • Text • Body Marker • Freeze Increased brightness when key is activated 22 Unrestricted © Siemens Healthineers 2022 Speaker Notes: When the ultrasound system is in use, the following keys on the Control Panel are supported by backlighting. • Power • Text • Body Maker • Freeze The brightness of the backlighting increases when a control is active. The alphanumeric keyboard on the Control Panel is also illuminated. A few of the primary keys will remain backlit in blue, as they are commonly used keys. Notes No. 22 SIEMENS Healthineers Thank you! SIEMENS. Healthineers ... Questions? 23 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Questions? Notes No. 23
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- POC
- Point of Care
- Trauma
- FAST
- eFAST
- BLUE
- FOCUS