Siemens Healthineers Academy

ACUSON P500 Ultrasound System 3.0 System Configuration Presentation

This job aid provides information on how to access system configuration and configure the ACUSON P500 system at 3.0 software.

SIEMENS Healthineers SIEMENS Healthineers ... ACUSON P500 Ultrasound System System Configuration 3.0 Software Release 1 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This presentation provides an overview of the ACUSON P500 Ultrasound System Configuration. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Access the Configuration Menu • Identifying the Configuration Menu Choices • Making Changes to the Configuration Menu • Review Configuration Menu SIEMENS 2 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here are the objectives of this presentation and we will start on how to access the configuration menu. Notes No. 2 SIEMENS Healthineers Locate the Configuration Menu SIEMENS. Healthineers ... 4 A 4 Patient Exam Review Report Browser Config Help Freeze 3 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Configuration Menu can be accessed from the Control Panel. Pressing the Config key will access the set-up menu. Notes No. 3 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Access the Configuration Menu • Identifying the Configuration Menu Choices • Making Changes to the Configuration Menu • Review Configuration Menu SIEMENS 4 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss the configuration menu choices. Notes No. 4 SIEMENS Healthineers The Configuration Menu SIEMENS. Healthineers ... Configuration Custom Keys General 1 General 2 Depth and Zoom Knob Direction Custom Keys Increase Depth Clockwise Counter-Clockwise Display Exam Increase Zoom Clockwise · Counter-Clockwise Soft Keys M&R Report Key Function Text Annotation Print/Store 1 mage Store Body Marker Wireless Print/Store 2 Image Store Network Clip Store Clip Store Service Clip Store Left Pedal Freeze Archive Right Pedal Image Store Security Printer User Defined 1 None Barcode User Defined 2 Arrow Utility Clip Store Stress Echo Biopsy eSieScan Configure New Key TEQ Update << Steer Not Used Steer >> Text A DVR Needle Visualization Pointer None ave Cancel 5 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Configuration menu is broken down in to 21 sections, although many of the choices are defaulted for the standard use. Notes No. 5 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Access the Configuration Menu • Identifying the Configuration Menu Choices • Making Changes to the Configuration Menu • Review Configuration Menu SIEMENS 6 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss how to make changes to the Configuration menu. Notes No. 6 SIEMENS Healthineers System Specifications SIEMENS. Healthineers ... • Use Touchpad to place the cursor General 1 Organization • Type in information Hospital Name ACUSON Drop-down menus Regional Settings • Language English Date 3/5/2015 Date Format Day/Month/Year Time 11:27: 9 • Scroll slide bar Height and Weight Units .Metric OU.S. Time Zone (UTC-08:00) Pacific Time (US & Cv -Audio Power Of • Select the setting Beep on Button Press Shut Down with Confirmation Dialog Beep after Store Completes Shut Down Shut Down with Confirmation Dialog Beep Volume • Press Save to store changes Doppler Volume 50 Touchpad Behavior Touchpad Travel Speed Medium Set By Tap O Off Save Cancel 7 Unrestricted © Siemens Healthineers 2022 Speaker Notes: For each section on the Configuration menu, use the touchpad to place the cursor to activate the following: • Typing in the information using the keyboard • Activating the drop-down menu and making selections • Adjusting the slide bar for the desired number Always press the Save key before exiting the menu. Notes No. 7 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Access the Configuration Menu • Identifying the Configuration Menu Choices • Making Changes to the Configuration Menu • Review Configuration Menu SIEMENS 8 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will review the Configuration menu. Notes No. 8 SIEMENS Healthineers General 1 SIEMENS . Healthineers ... Configuration General 1 General 1 .... Organization General 2 Custom Keys Hospital Name ACUSON Display Exam Soft Keys Regional Settings Language English 2/23/2016 Report Date Text Annotation Date Format Day/Month/Year Time 5 :23:58 Body Marker Height and Weight Units OU.S (UTC-08:00) Pacific Time (US & C Wireless Metric Time Zone Network Service Audio Image Settings Clip Store Archive Beep on Button Press Image Presets Standard Security V Beep after Store Completes Standard Printer Americas Barcode Beep Volume Power Off Europe Utility Stress Echo Doppler Volume - 50 Shut Down with Co Asia MEA (Middle East Africa) eSieScan Touchpad Behavior Touchpad Travel Speed Medium Set By Tap · On O off Save Cancel 9 Unrestricted © Siemens Healthineers 2022 Speaker Notes: General 1 menu is where the hospital name is added. Access the regional presets in this menu and when finished the system will need to reboot. It is important to check that the date and time zone are correct during the first boot up. In the Power Off section, enabling Shut down with bypass a confirmation dialog may be a choice for the Emergency Medicine department where speed is very important. The touchpad speed defaults to medium and can be changed to the users preference. Notes No. 9 SIEMENS Healthineers General 2 SIEMENS. Healthineers ... Configuration General 2 General 1 General 2 Patient ID Custom Keys Save an image of the Patient screen after registering a patient. Display Exam Hide Patient Banner Soft Keys M&R Report Common Mode Text Annotation Delete Body Marker on Unfreeze Body Marker Wireless Delete Text on Unfreeze Network Body Marker Location O Upper Right . Lower Right Service Clip Store Arrow Size Small (Type2) Archive Patient Registration Long Form Security Printer Barcode Transducer Power Utility Stress Echo Reduce Transducer Power in bare status Off eSieScan Off 5 secs 3 mins 5 mins 10 mins Save Cancel 10 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The General 2 menu has the option to save an image of the patient screen after registering a patient. This automatically stores this screen as part of the exam and the default is not- checked. There is an option to select the body marker location. The transducer Power Saver option is located here. Setting a selection will save transducer life by reducing Power to 1-10% when not in use and the default is set to off. Notes No. 10 SIEMENS Healthineers Custom Keys SIEMENS. Healthineers ... Configuration Custom Keys General 1 Depth and Zoom Knob Direction General 2 Custom Keys Increase Depth Clockwise Counter-Clockwise Display Exam Increase Zoom Clockwise · Counter-Clockwise Soft Keys Report Key Function Text Annotation Print/Store 1 Image Store Body Marker Wireless Print/Store 2 Image Store Network Clip Store Clip Store Service Clip Store Left Pedal Freeze Archive Right Pedal Image Store Security Printer User Defined 1 None Barcode User Defined 2 None Utility Stress Echo eSieScan Configure New Key Not Used .Close Study Save Cancel 11 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The New Key (located on the keyboard) will automatically close the previous study to allow for immediate scanning without patient information to be added. This is helpful for Emergency Room scanning when a Fast exam is needed or to scan quickly The Custom keys menu allows the Depth and Zoom keys to be programmed for clockwise or counter-clockwise depending on the user preference. The two Print/Store keys, Clip Store, Foot Pedal and the two user defined keys can be set to the customer preferences. Using the touchpad, place the cursor and using the drop-down menu, select the option desired. Notes No. 11 SIEMENS Healthineers Custom Keys SIEMENS. Healthineers ... Print/Store Clip Store Foot Pedal User-defined • Full D • Image Store Freeze • PC Printer • • Image Store Clip Store • • Image Store Full M • • Clip Store • Clip Store Arrow • • Caliper Clip Store • Image Store • • • Update CW* and PC Printer • • TEQ Update Pointer* • <> • L/R Flip • Text A / Text B 12 Unrestricted © Siemens Healthineers 2022 Speaker Notes: These are the drop-down choices for the keys in the Custom Key menu. Please Note: Set-up the Steer (either one) as one of the custom keys as it will cycle both ways, therefore, there is no need to use both keys for this function. Notes No. 12 SIEMENS Healthineers Display SIEMENS . Healthineers ... Configuration Display General 1 General 2 Monitor DGC Custom Keys Screen Saver Delay 20 minutes DGC Invert with Image Invert Display Exam System Power Off 2 hours DGC Curve Display Time Out Soft Keys Brightness 44 DGC Control Current Image Depth Report Text Annotation Body Marker Wireless Patient Banner Network Patient Data · Age Date of Birth Service Clip Store Archive Doppler / M-Mode Security Printer Bypass Cursor Mode Barcode Doppler Frequency/Velocity Frequency Velocity Utility Stress Echo eSieScan Save Cancel 13 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Display menu options are as follows: • The System has a screen saver built in and the default is 20 minutes although can be changed using the drop-down menu • To reserve power and battery, the system is defaulted to power off every 2 hours, therefore this should be changed if the system is to be used more than the allotted time • Adjusting the brightness may affect the image optimization intended by the factory-defined image presets, therefore, adjust the brightness and contrast of the monitor before changing any image quality settings • The Depth Gain Compensation (DGC) curve display can be set to time out or stay on or off and the DGC control can adjust the DGC controls for the current image depth or maximum depth • The Patient banner can be adjusted to display patient age or date of birth or both and the default is set to age • To bypass the Doppler/M-Mode cursor, select Bypass Cursor Mode, and the default is set to unchecked • Doppler Frequency or velocity display option is located here Notes No. 13 SIEMENS Healthineers Exam SIEMENS. Healthineers ... Configuration Exam General 1 General 2 Exam Abdomen Custom Keys Abdomen Display Freeze Behavior OB Exam Early OB Soft Keys Seamless Dual GYN Off MSK Report 2D/M & 2D/Doppler Di Breast - 1/2 Trace Text Annotation Small Parts Body Marker Doppler Update Style PV-Arterial / D-Lv Wireless CV Doppler Auto Stat Off Network PV-Venous Service Doppler Trace Orienta Renal ve Baseline Below Baseline Both EM Clip Store Auto Invert of Color V Pelvis Archive O off Security Auto Invert of Color and Spectrum On of Printer Barcode 2D Steer with Cursor On O Off Utility Stress Echo Physio Management 3 Lead ECG Display Aux ECG Display eSieScan Aux Signal Display Respiration Display Indicate R-Wave Lead Type I Lead Type II Save Cancel 14 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Exam menu allows the user to set-up different parameters for workflow. These can be set-up for specific applications therefore, these are not an all-system functionality. Freeze Behavior option is once the image is frozen, the behavior of the touchpad and soft key menu will default to the selection. The system default is set to Cine, although other choices are text, caliper, arrow or body marker. The most commonly used function is Cine. Seamless Dual is used for linear transducers and turning this on allows for easy match-up of a thyroid, breast, or vascular exams and the default is set to Off. 2D/M & 2D Doppler display allows the choices for the ratio of mode to image. Depending on the customer preference, this may be different depending on the application. Doppler Auto Stat controls the option to have auto stats on or off with the choice to activate it with the action keys when needed. The default is set to Off. Doppler Trace Orientation is the option to have the trace above, below or on both sides of the baseline. Auto Invert of Color with Auto Invert of Color and Spectrum can be selected on or off. 2D steer with Cursor can be selected on or off. Notes No. 14 SIEMENS Healthineers Physio Management has multiple options to choose from. Notes No. 14 SIEMENS Healthineers Exam SIEMENS. Healthineers ... Exam Freeze Behavior Display Size Doppler Update • Abdominal / • Caliper • 2D Frz / D - Lv Renal • Arrow ½ 2D – ½ Trace • 2D-Lv / D - Lv • • Emergency Med • Text • ⅓ 2D – ⅔ Trace • D-Lv / 2D - 1s • Vascular • Cine • D-Lv / 2D - 2s • ⅔ 2D – ⅓ trace • Small parts • Body Marker • Side by Side • D-Lv / 2D - 3s • Breast / MSK • D-Lv / 2D - 4s • OB / Early OB • D-Lv / 2D - 8s • Neo Head • Cardiac / Ped Card 15 Unrestricted © Siemens Healthineers 2022 Speaker Notes: These are the drop-down choices for the keys in the Exam menu. Notes No. 15 SIEMENS Healthineers Soft Keys SIEMENS. Healthineers ... Configuration Soft Keys General 1 2D Lv 2D Frz CLV Cr| | | | | |Frz General 2 Custom Keys Display Exam Physio Settings Soft Keys Report Text Annotation Body Marker Biopsy Wireless Network Service << Steer Steer >> Clip Store MultiHertz Archive Dyn R Security UR Flip U/D Flip Edge Printer Map Tint Barcode Full Size rapezoid Persist << CENTER Utility Tx Power Stress Echo eSieScan Dual Image Presets| Adv. SieClear DTCE MultiHertz THI Focus Position Default Clear Page Default Clear Page Clear All Pages Save Cancel 16 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There is maximum flexibility for the user to program the Soft Keys. They can be programmed for each mode from 2D, Color, M-Mode and Doppler live. They also can be programmed when in the frozen state. Notes No. 16 SIEMENS Healthineers Soft Keys – 2D SIEMENS. Healthineers ... Soft Keys MultiHertz 2D Lv 2D Fr| | | | PF| | | | FIZ Dyn R Edge Map Physio Settings Tint Persist Biopsy Tx Power < < Steer Steer >> THI MultiHertz Dyn R Focus Position L/R Flip U/D Flip Edge Map Focus Number Tint Full Size Trapezoid Persist << CENTER >> Tx Power DTCE Adv. SieClear .............. ................. . Image Presets| Adv. SieClear DTCE MultiHertz THI Focus Position Image Presets Blank Default Clear Page Default Clear Page Clear All Pages Save Cancel 17 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here is an example of the choices for 2D image parameters and every key has the same options. Notes No. 17 SIEMENS Healthineers Soft Keys – 2D Left Panel Control Keys SIEMENS. Healthineers ... Full Size Soft Keys Dual 2 D LV 2D Frz | CLV | CFIZ | PLV | PFIZ | ML V | MFIZ | DLV | D FIZ | U/D Flip Physio Settings V/R Flip Trapezoid Biopsy Biopsy Biopsy Clip Settings Steer >> << Steer Steer >> Clip Settings Physio Settil Blank UID Flip << Steer Full Size Trapezoid CENTER > > Steer > > Dual Image Presets| Adv. SieClear DICE MultiHertz THI Focus Position Physio Settil Blank Default Clear Page Default Clear Page Clear All Pages Save Cancel 18 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Here is another example of the choices for 2D image parameters. Notes No. 18 SIEMENS Healthineers Measurements and Reports SIEMENS. Healthineers ... Configuration M&R General 1 General 2 Custom Keys Display Measurement and Report Configuration Exam Soft Keys Cardiac Report Text Annotation Body Marker Wireless Measurement Method >> Network Service Measurement Order >> Clip Store Archive Security Display Items >> Printer Barcode User-Defined Measurement Labels >> Utility Stress Echo Comments Library >> eSieScan General Configuration >> Anatomy Assessments >> 19 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The next menu choice is M&R or Measurements and Reports. A separate presentation is available and covers more detail. This is programmable by the application and is more extensive in applications with dedicated measurement packages. Notes No. 19 SIEMENS Healthineers Measurement Method SIEMENS. Healthineers ... M & R > > Measurement Method : Abdomen Measurement Method >> -Default Measurement Method by Mode Measurement Order >> 2D Mode Distance Display Items >> M-Mode HR Doppler Velocity User-Defined Measurement Labels >> -Default Measurement Method Comments Library >> Area Ellipse Volume 3 Dist General Configuration >> % Stenosis Area - %Stenosis Anatomy Assessments >> 2D Mode Ratio Distance Ratio M-Mode Ratio Distance Ratio Flow Volume Area - Flow Volume PI Trace PI Auto Default Previous Save Cancel 20 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The first choice is Measurement Method and each section has a drop-down menu. Here are the default values for this application. Notes No. 20 SIEMENS Healthineers Measurement Order SIEMENS. Healthineers ... M&R > > Measurement Order : Abdomen Measurement Method >> Mode 2D-Mode Measurement Order >> 2D-Mode Measur M-Mode Measurement Order Display Items >> Doppler TEST User-Defined Measurement Labels >> Add Comments Library >> Remove General Configuration >>> Move Up Move Down Anatomy Assessments >> Default Previous Save Cancel 21 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Depending if the application has an associated measurement package with it, it would be populated here in the Measurement Order menu. Notes No. 21 SIEMENS Healthineers Display Items SIEMENS. Healthineers ... M&R > > Measurement Results : Cardiac Measurement Method >> General Measurement Order >> Default Measurement Title 2D Mode None Display Items >> M-Mode None User-Defined Measurement Labels >> Doppler None Measured Results · Direct Average Comments Library >> HR Measurement Method O ECG Doppler / M-Mode Auto Stat General Configuration >> Display of Measurement Labels Measurement Type O Last Used Display AOLA Y AOd/LAS VLAS/AOd Anatomy Assessments >> Default RAP 10mmHg eSie Measure Settings eSie Measure On Off Heart Cycle to Display MI-Mode Doppler WN - Default Previous 22 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Display Items menu is where you have different options to display the measurements. Notes No. 22 SIEMENS Healthineers User-defined Measurement Labels SIEMENS. Healthineers ... M&R >> User-Defined Label : MSK Measurement Method >> -2D Mode User-Defined Measurement Label Measurement Order >> User-Defined 1 Label Name BURSA .......... Display Items >> Measurement Method Distance Distance Delete Current 2D Mode Label User-Defined Measurement Labels >> M-Mode User-Defined Measurement Label Comments Library >> User-Defined 1 Label Name General Configuration >>> Measurement Method Distance Delete Current M-Mode Label Anatomy Assessments >> Doppler Mode User-Defined Measurement Label User-Defined 1 Label Name Measurement Method Velocity Delete Current Doppler Label Previous Save Cancel 23 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The User-Defined Measurement Labels menu has the options for the different measurement modes. The number of user-defined labels available to create is 20 for each 2D, M-Mode and Doppler. Notes No. 23 SIEMENS Healthineers User-defined Measurement Labels SIEMENS. Healthineers ... M&R >>>> Comments Library : Abdomen Measurement Method >> Comments 1 Comments 2 Measurement Order >> Comments 1 Comment 1 .............. Display Items >> Comment 2 User-Defined Measurement Labels >> Comment 3 Comment 4 Comments Library >> Comment 5 . .............. General Configuration >> Comment 6 Comment 7 Anatomy Assessments >> Comment 8 Comment 9 Comment 10 Previous Save Cancel 24 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The User-Defined Measurement Labels menu has the options for the different measurement modes. The number of user-defined labels available to create is 20 for each 2D, M-Mode and Doppler. Notes No. 24 SIEMENS Healthineers General Configuration SIEMENS. Healthineers ... M & R > > General Configuration : Abdomen Measurement Method >> -Caliper Configuration Measurement Order >> Caliper Default Position Center Display Items >> Caliper Size Large ................. Caliper Pattern O+ User-Defined Measurement Labels >> Measurement Results Background Or off Comments Library >> Measurement Result Display Bottom General Configuration >> 2D Mode Doppler / M-Mode Bottom Top .................. Bottom Anatomy Assessments >> Left Right Default Previous Save Cancel 25 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The General Configuration menu is where the caliper placement, size and type can be selected and are application specific. The measurement display options can be configured here. Notes No. 25 SIEMENS Healthineers Anatomy Assessment SIEMENS. Healthineers ... M&R >> Anatomy Assessments : Abdomen Measurement Method >> Item Selections Measurement Order >> Display Items >> Items List *Liver echogenic *Liver ...................... User-Defined Measurement Labels >> Comments Library >> General Configuration >> Add Remove Anatomy Assessments >> . .................... Default Previous Save Cancel 26 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Anatomy Assessments menu is where the general comments regarding anatomy clinical findings can be added. This is especially useful for General Imaging, Abdominal, Thyroid and Breast. Notes No. 26 SIEMENS Healthineers Report Order SIEMENS . Healthineers ... Configuration Report General 1 Report Order Print Preview General 2 Custom Keys Exam Cardiac Display Available Report Sections Selected Report Sections Exam Soft Keys Mod.Simpson AVILA Single Plane Aortic Valve Bi-Plane Mitral Valve Report Bullet Simpson BP Text Annotation Cubed(2D) Simpson SP Body Marker Gibson(2D) Teichholz(2D) Wireless LV Mass T-E LA Vol(Simp) Add LV Mass A-L Network LA Vol(A-L) Service RA Vol(A-L) Remove PISA(MR' Clip Store RA Vol(Simp) Qp/Qs Archive PISA(MS) LV/Teich(M) Security LV/Cubed(M) AV/LA(M) Printer LV/Gibson(M) Mitral Valve(M) Barcode Utility Tricuspid Valve Pulmonary Valve Stress Echo Pulmonary Vein eSieScan AR TR MR PR Save Cancel 27 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Report menu is where a custom logo can be added. A Universal Serial Bus (USB) device must be attached to the system, then select Load to upload the desired file which must be Joint Photographic Experts Group (JPEG) and not located in a folder. The physician signature can be added and removed here. Notes No. 27 SIEMENS Healthineers Report Print Preview SIEMENS. Healthineers ... Configuration Report General 1 Report Order |Print Preview General 2 Site Information Custom Keys Display Logo Exam Text 1 Soft Keys Font Text 2 Report Text Annotation Font Body Marker Load Text 3 Wireless Font Network Service Clip Store Archive Signature Reference Values Security Display Adult Cardiac Reference Values Printer Barcode Add Remove On · Off Utility Stress Echo eSieScan Save Cancel 28 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Report menu is where a custom logo can be added. A Universal Serial Bus (USB) device must be attached to the system, then select Load to upload the desired file which must be Joint Photographic Experts Group (JPEG) and not located in a folder. The physician signature can be added and removed here. Notes No. 28 SIEMENS Healthineers Text Annotation SIEMENS . Healthineers ... Configuration Text Annotation General 1 General 2 Exam Small Parts Custom Keys Display Annotation Library TextA | Text B| Exam Soft Keys Enable Auto Complete M&R Report Available Annotations Selected Annotations Text Annotation Thyroid Right Isthmus Body Marker Sagittal Lobe Wireless Trans Medial Network Coronal Lateral Superior Service Modify Mid Clip Store Inferior Archive Add Anterior Posterior Security Printer Remove Node Solid Barcode Cystic Calcification Utility Anechoic Stress Echo Echogenic Hypoechoic eSieScan ICA ECA CCA Jugular Parathyroid Default Save Cancel 29 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Text Annotation menu allows the user to customize annotation libraries for selected exam types and user-defined exams. They can enter user-defined annotation or modify selected annotation. From the available annotation's menu, the user can Add / Delete selected annotations and Move Up / Move Down the selected annotation in the preferred order based on the users protocol. Notes No. 29 SIEMENS Healthineers Body Marker SIEMENS. Healthineers ... Configuration Body Marker General 1 General 2 Exam OB Custom Keys Display Available Body Markers Selected Body Markers Exam Soft Keys M&R Report W Text Annotation (S) Body Marker Wireless Add Network Service Remove Clip Store Archive Security Printer Barcode Utility Stress Echo eSieScan Default Save Cancel 30 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Body Marker menu is where the user can customize body marker libraries for selected exam types or user-defined exams. The menu displays a library of pictograms for selected exam types or user-defined exams. All body markers are in the library therefore, any body marker can be added to a specific exam. The user can Add / Delete selected pictograms from a library and Move Up / Move Down the selected pictogram within the library for order of placement depending on their protocol. Notes No. 30 SIEMENS Healthineers Wireless SIEMENS. Healthineers ... Configuration Wireless Config General 1 Wireless Network General 2 Custom Keys Display Wireless On/Off @ on Off Exam Soft Keys IP Address Settings Available Networks M&R Report O DHCP Static IP Address SSID Connection| Signal Security Saved Text Annotation Body Marker IP Address: 0 . 0 . 0 . 0 Wireless Network Subnet Mask: . 0 . 0 . 0 Service Clip Store Default Gateway: 0 . . 0 . 0 .0 Archive MAC Address: 3C - A9 - F4 - AB - 93 - 44 Security Printer Barcode Clear Apply Refresh Add Edit Connect Utility Stress Echo Status: Searching for wireless networks .. eSieScan Save Cancel 31 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Wireless sends data, such as studies, images, and clips to a network location over a wireless network and Requires approved wireless adapter, purchased separately. Wireless is a standard feature. Notes No. 31 SIEMENS Healthineers Network SIEMENS. Healthineers ... Configuration Network General 1 Local Host Storage Server | Worklist Server | Network Export Server General 2 Custom Keys Default Show Network Status Display Exam Soft Keys M&R Report New Edit Delete Text Annotation Body Marker Wireless Static IP Address Network Service Alias: Default IP Address: . 0 . 0 Clip Store AE Title: Default Subnet Mask: Archive 0 . 0 . 0 Security Host Name: Default Default Gateway: . 0 . 0 . 0 Printer Barcode MAC Address: 00-13-95-15-FA-CC Utility Stress Echo Media Type Hardware Default Duplex Mode Hardware Default eSieScan Save Cancel 32 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Setting up the Digital Imaging and Communications in Medicine (DICOM) network shall be done by the local service team. Should it be required to complete, review the manual for correct set-up. It will be important to work with the local Information Technology (IT) department onsite to get the information needed to interface. DICOM is an option on the system. Note: DICOM printer is not supported. Network Export is an excellent way to send reports over to a Personal Computer (PC) when a DICOM network is not in place. Notes No. 32 SIEMENS Healthineers Service SIEMENS. Healthineers ... Configuration Service General 1 General 2 -System Information Custom Keys ACUSON P500 KT PP3018_V 0.9.4 Display S/N: PP3018 Exam Soft Keys Version: VADOA (0.9.4_p1) ............... M&R Report System: VA00A (0.9.4_p1) Text Annotation System Internal: 0.9.4_p1 S/N: PP3018 [20141128 12:43:01] Body Marker P/N: 10785577 [20141128 12:43:01] Wireless OS Configuration: 0.0.6 Framework: 0.10.5 [20150106] Network Platform Software: 0.18.8 [20150106] Service PIMS: 0.8.35 [20150106] Clip Store UBE: 0.8.20 [20150106] Archive Security Printer Barcode Service Utility Stress Echo Remote eSieScan Remote Application Support Restore Factory Settings Save Cancel 33 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Service menu contains the system information and is where the Remote Application Support is located. Notes No. 33 SIEMENS Healthineers Clip Store SIEMENS. Healthineers ... Configuration Clip Store General 1 General 2 Compression: Medium Custom Keys LOW O High Display Exam Capture Type: . Prospective Retrospective Soft Keys M&R ................... Report Clip Length: @ Time 3 sec Text Annotation Body Marker Wireless Beat beats Network Service Clip Store OR-wave only R-wave delay: msec Archive Security Printer Barcode Utility Stress Echo eSieScan Save Cancel 34 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Clip Store menu has the following options: • Choose the compression for best image quality and storage size • The capture type can be prospective or retrospective • retrospective capture records imaging a few seconds before pressing clip store • Prospective starts recording imaging at the press of Clip Capture • Clip Length be set for a time capture from 1-60 seconds • R-Wave Only can be configured here For procedural exams like a biopsy, retrospective capture can be useful to capture the needle and is suggested to set the time frame slightly longer. Notes No. 34 SIEMENS Healthineers Archive SIEMENS. Healthineers ... Configuration Archive General 1 General 2 General Custom Keys Options for Deleting Archived Studies Display Delete Study History after Study is Deleted Exam Soft Keys M&R Manually Delete Study History after Study is Deleted ..................... Report Text Annotation Keep Study History after Study is Deleted Body Marker Wireless Network Service Show Deleted Studies in Browser Clip Store Archive . .................. : Security Printer Barcode Utility Stress Echo eSieScan Save Cancel 35 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Archive menu allows the user to determine how studies will be archived and if deleted studies are shown on the browser. The default is set to Delete Study History after Study is Deleted. Notes No. 35 SIEMENS Healthineers Security SIEMENS. Healthineers ... Configuration Security General 1 General 2 Security Health Custom Keys ¥ syngo Security Configure > Display V Windows 10 Exam Soft Keys X Firewall M&R Ports Detail > Report ...................... V Windows Hotfixes Detail> Text Annotation Body Marker V User Account Management Wireless V Audit Trail Detail > Network Service X FIPS (Federal Information Processing Standard) Enable Clip Store BIOS Password Archive Security Memory Protection (ASLR, SEHOP, DEP) ..................... : Printer X Disk Encryption Barcode MDS2 Detail >> Utility Stress Echo VOSS Clearance Detail >> eSieScan ¥ Client Certificate Configure Save Cancel 36 Unrestricted © Siemens Healthineers 2022 Speaker Notes: When accessing the Authorization menu for the first time, the system prompts a set up of an administrator account and Password access. Notes No. 36 SIEMENS Healthineers Printer SIEMENS . Healthineers ... Configuration Printer General 1 General 2 -Printe Custom Keys Display PC Printer Sony UP-D25MD Status Exam Soft Keys USB B&W Printer Status M&R Report Status .................... Text Annotation USB Color Printer Body Marker Wireless Install ... Network Service Clip Store Thumbnails Printer Archive Sony UP-D898MD/X898MD Security . None Printer Sony UP-D25MD Barcode O PC Printer MITSUBISHI P95D Utility Stress Echo O USB B&W Printer MITSUBISHI CP30D DW(USB) eSieScan O USB Color Printer Save Cancel 37 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Printer menu is the location to select the printer to be used as well as guide through the installation procedure. This is done at the time of the service installation and performed by the service engineer. The drop-down menu display the printers available. Notes No. 37 SIEMENS Healthineers Barcode SIEMENS . Healthineers ... Configuration Barcode Settings General 1 Connection Status Disconnected General 2 Custom Keys Sample Text Offset Length Display Exam Scanned Data Scan a barcode Soft Keys M&R []Use Separator Report Text Annotation Offset Length Order ....................... Body Marker Wireless Last Name Set 65 Network Service First Name Set Clip Store Archive Patient ID Set Security Printer Barcode Performing MD Set 65 Utility Stress Echo Sonographer Set 65 eSieScan Accession No. Set 65 Save Cancel 38 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Barcode menu allows the user to set up all the options needed to use a barcode reader. Step by step directions are available in the manual. The barcode device is connected to one of the USB ports. Notes No. 38 SIEMENS Healthineers Utility SIEMENS. Healthineers ... Configuration Utility General 1 General 2 Clip Playback Custom Keys Display . Play Only Active Clips Exam Soft Keys Play All Clips Loop Aligned M&R Report Text Annotation Slide Show Body Marker Wireless Image Duration (sec) 3 Number of Replay Loops Network Service Clip Store Archive Security Printer Barcode Utility Stress Echo eSieScan Save Cancel 39 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Utility menu is where the user can set up clip playback options. Also displayed are the slide show options. Notes No. 39 SIEMENS Healthineers Stress Echo SIEMENS. Healthineers ... Configuration Stress Echo General 1 Protocols General 2 Custom Keys Pharmacology Rest Display Pharmacology Continuous Low Exam Bicycle Peak > Soft Keys ................ M&R Bicycle continuous Post Report readmill Text Annotation Body Marker Treadmill Continuous Wireless Network Service Copy Add Rename Delete Clip Store Archive Protocol Settings Review Settings Security Printer ROI On Display Format : 4x4 Barcode Utility Allow Selection of Multiple Clips per View Default Playback Mode : Full R-R Stress Echo eSieScan Default Playback Speed : 100% Default Clip Sorting : By View By Stage Export Import Default Save Cancel 40 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The Stress Echo menu is where the user sets up the protocols for Stress echo and the review settings. Notes No. 40 SIEMENS Healthineers eSie Scan Workflow Protocols SIEMENS. Healthineers ... Configuration eSieScan General 1 Protocols General 2 Routine Echo Protocol Name Custom Keys PLAX PLAX Display PLAX Exam PLAX Soft Keys PLAX Rename M&R PLAX RVIT Automatically ends when all views completed. Report RVIT Text Annotation RVIT -At End Protocol Body Marker PSAX AV Wireless PSAX AV Remain in acquisition PSAX IAS Network PSAX TV Enter Review Service PSAX TV Clip Store RVOT Enter Report Archive RVOT Security RVOT PV PSAX LV BASE Printer PSAX LV MID PAP Barcode PSAX APEX Utility Apical 4ch Apical 4ch Add Protocol Stress Echo Apical 4ch eSieScan Apical 4ch Add View Apical 4ch Apical 4ch Copy Apical 5ch Default Apical 5ch Delete Apical 2ch Export Import Save Cancel 41 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The eSie Scan menu is where Workflow protocols for Cardiology are customized. Protocols are not available for other exam types. Notes No. 41 SIEMENS Healthineers Thank you! SIEMENS. Healthineers ... Questions? 42 Unrestricted © Siemens Healthineers 2022 Speaker Notes: No speaker notes. Notes No. 42

  • Interventional Cardiology
  • Interventional Radiology
  • Critical Care
  • Liver Disease
  • Oncology
  • Surgery
  • Urology
  • Ultrasound
  • Interventional Cardiology
  • Interventional Radiology
  • Critical Care
  • Liver Disease
  • Oncology
  • Surgery
  • Urology
  • Ultrasound
  • POC
  • Point of Care
  • Trauma
  • FAST
  • eFAST
  • BLUE
  • FOCUS