ACUSON P500 Ultrasound System 3.0 5VT Transesophageal Transducer Presentation
This job aid provides information using the 5VT Transesophageal transducer on the ACUSON P500 system at 3.0 software.
SIEMENS Healthineers SIEMENS Healthineers .. ACUSON P500 Ultrasound System 5VT Transesophageal Transducer 3.0 Software Release 1 Unrestricted © Siemens Healthineers 2022 Unrestricted Speaker Notes: The purpose of this presentation is to serve as an overview of the 5VT transesophageal (TEE) transducer with the ACUSON P500 ultrasound system. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Transducer and connection SIEMENS • Discuss transducer controls and operation • Review care and cleaning SIEMENS 2 Unrestricted © Siemens Healthineers 2022 Speaker Notes: This presentation will cover the following topics regarding the 5VT transducer: • Transducer and connection • Discuss transducer controls and operation • Review care and cleaning Notes No. 2 SIEMENS Healthineers Transducer SIEMENS. Healthineers ... • Improved articulation sleeve material for durability • Twin Cam - Zero Insertion Force connector for seamless connection (no adapter is needed) 3 Unrestricted © Siemens Healthineers 2022 Speaker Notes: For those who are familiar with the V5Ms transesophageal transducer, the 5VT transducer is similar to the V5Ms in lens and rotary handle functionality. However, the 5VT transducer has different articulation sleeve material providing improved durability, and it uses the same Twin Cam – Zero Insertion Force connection as the rest of the ACUSON P500 transducers. This means the 5VT transducer connects seamlessly to the ACUSON P500 ultrasound system and does not require an adapter. Note: The 5VT transducer is compatible with the ACUSON Juniper ultrasound system. Notes No. 3 SIEMENS Healthineers Transducer frequencies SIEMENS. Healthineers ... Application Transesophageal echo Number of Elements 64 Bandwidth 3.1-9.2 MHz B-mode Fundamental 3.6, 4.0, 5.0, 5.7 MHz Frequencies B-mode Harmonic 5.0, 5.7 MHz Frequencies Doppler Frequencies 3.1, 3.8 MHz (Color, DTI, Spectral, PW) CW Frequency 2.9, 3.3 MHz Max Field of View 90° 4 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The following chart displays the available frequencies for each imaging mode, such as B-mode and Doppler. The number of elements is 64 and the max field of view is 90 degrees. Notes No. 4 SIEMENS Healthineers Transducer connection SIEMENS . Healthineers ... • Message appears at ACUSON ACUSON P500 5VT transducer connection TEE 50% O MI 0.43 TIS 0.4 TIB 0.4 EScan DTCE Low Dyn R 65 dB 5.0 MHZ • Select OK 0 dB 51 fps ransducer Connection 0 bpm < 37ºC Refer to the warnings and precautions in the user Lens Temp i manual before each use of the transesophageal transducer. Review instructions for leakage current testing and for inspection, proper use, and disinfection of the transesophageal transducer. Flip OK pezold 12 cm us Nu .. THI DICE Dyn R MultiHertz Focus Tx Pow us Posi ... Low 65 dB 5.0 MHZ Position 5 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Upon connection of the 5VT transducer, the following message appears. Select OK to continue to imaging. Notes No. 5 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Transducer and connection SIEMENS • Discuss transducer controls and operation • Review care and cleaning SIEMENS 6 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Next, we will discuss transducer controls and operation. Notes No. 6 SIEMENS Healthineers Transducer controls and operation SIEMENS . Healthineers ... Flex controls • Rotate control to bend the articulating section of the transducer shaft • Anterior/Posterior (A/P) flexion is controlled with larger (light gray) top flex control • Right/Left (R/L) flexion is controlled with smaller (dark gray) bottom flex control 7 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are two separate rotary controls for Anterior/Posterior (A/P) flexion and Left/Right (L/R) flexion. The top rotary (light gray) control guides A/P flexion. The smaller bottom rotary (dark gray) control guides L/R flexion. Notes No. 7 SIEMENS Healthineers Transducer controls and operation SIEMENS. Healthineers ... Friction brakes • One on each side of the transducer • Locks the flex controls • Two separate brake controls for A/P (light gray) and R/L (dark gray) flexion 8 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There are friction brakes on either side of the handle for the A/P and L/R flexion controls. Simply press to the locked/unlocked side to lock or unlock the flexion capabilities. Notes No. 8 SIEMENS Healthineers Transducer controls and operation SIEMENS. Healthineers ... Array rotation control • Rotates the array within distal tip of the transducer • Position of the array corresponds to the scan plane, which is adjustable from 0° to 180° • 90° rotations can also be performed from a programmed touch screen control • Press to increase/decrease; press and hold for rapid angle adjustment 9 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The array rotation control rotates the array within the distal tip of the transducer. The position of the array corresponds to the scan plane, which is adjustable from 0° to 180°. Press the control to increase or decrease the angle. Press and hold for rapid angle adjustment. 90° rotations can be performed from a configured touch screen control (see next slide). Notes No. 9 SIEMENS Healthineers Transducer controls and operation SIEMENS . Healthineers ... Array rotation control from the touch screen Configuring soft key options 20 Configuration Soft Keys General 1 2D Lv 20 Frz Clv CFiz PLv PFrz M.Lv M Frz|DLv DF2 General 2 available on left side of touch Custom Keys Display Exam Physio Setting Stress Echo Soft Keys MAR Rotane-90 screen Report Text Annotation Body Marker Nopay Wireless Network Split Service WD Hip Clip Store L/R Flip Archive Trapezoid Security Biopsy • Open System Configuration Printer Clip Settings Barcode « Steer Utility Steer >> CENTER Stress Echo Rotate :90" (TEE) @SieScan Rotate +90º [TEE) • Select the Soft Keys option Physio Settings Adv. SinClar DICE Multisierte Focus Position • Select desired label placement Default Clear Page Default Clear Page Clear All Pages Save Cancel • Choose Rotate -90° (TEE) and/or Rotate +90° (TEE) DICE MuniHerta 10 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Touch screen control for quick rotation of the array in 90° increments is available in system configuration. For configuration of the touch screen controls on the left side of the screen: • Open System Configuration • Select the Soft Keys option • Select the desired touch screen placement for display, and then select Rotate -90° (TEE) and / or Rotate +90° (TEE) as desired from the dropdown menu Note: These quick rotation controls can also be configured for use with the footswitch or as User Defined keys by going under Custom Keys in System Configuration. Notes No. 10 SIEMENS Healthineers Transducer controls and operation SIEMENS . Healthineers ... Array rotation control from the touch screen Configuring soft key option Configuration Soft Keys General 1 2D Lv 20 Frz Clv CFiz PLv PFrz M.Lv M Frz|DLY|D Fr2 General 2 available on bottom of touch Custom Keys Display Exam fysio Settings Stress Echo Soft Keys MAR Siescape eSieSon screen Report Text Annotation Body Marker Blogsy werde Viajal. THI wireless Focus Position Network Focus Number Service ce Steer Steer>> DTCE Clip Store Adv. SieClear Archive Image Presets Security Clarify VE Open System Configuration Un Efp Clarify VE Levels Printer • Barcode DTI Utility Trapezoid Rotate 90" (TEE) CENTER Stress Echo Blank eSieScan Select the Soft Keys option Dua Adv. SieClear DICE Dym K Maniierte Focus Position • • Select desired label placement Default Clear Page Default Clear Page Clear All Pages Save Cancel • Choose Rotate 90° (TEE) DICE MuniHerta 11 Unrestricted © Siemens Healthineers 2022 Speaker Notes: There is an additional option for touch screen control for quick rotation of the array in 90° increments. For configuration of the touch screen control on the bottom of the screen: • Open System Configuration • Select the Soft Keys option • Select the desired touch screen placement for display, and then select Rotate 90° (TEE) from the dropdown menu Note: After configuring this Rotate 90° (TEE) option, pressing up or down on the control panel beneath this soft key adjusts the angle up or down correspondingly in 90° increments. Notes No. 11 SIEMENS Healthineers Transducer controls and operation SIEMENS . Healthineers .. 2D ACUSON ACUSON P500 G 5VT TEE Physio 50% Settings Echo 180 MI 0.43 TIS 0.4 TIB 0.4 SieScape eSieScan DTCE Low Dyn R 65 dB 5.0 MHZ Porate 0 dB 51 fps 0 bpm Steer >> <37ºC Lens Temp L/R Flip WD Flip Full Size Trapezoid Dual Split 12 cm Clear Delete Edge Rotate 90º DICE Dyn R MultiHertz Focus Tx Power TEQ Gain Focus Nu ..... Persist Low Position Map Focus Nu .... Focus Posi ... 05 GB 3.0 MHZ Time Focus Posi ... 12 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The following image displays the rotate 90° controls that have been configured on the touch screen for the 5VT transducer. Press the desired touch screen label to increase or decrease the angle in 90° increments. Note: Once configured, the 90° quick rotate touch screen controls are operational only when the 5VT transducer is in use on the system; otherwise, they will be dithered. Notes No. 12 SIEMENS Healthineers Transducer controls and operation SIEMENS . Healthineers ... ACUSON P500 Scan plane indicator 20 ACUSON 5VT TEE 120 • Displays rotation angle Physio Settings Echo 50% 180 TIS of the scan plane TIB 0.4 Rotate eSieScan DTCE Low Dyn R 65 dB 5.0 MHZ Visual 0 dB 51 fps 0 bpm Temperature indicator << Steer Steer> $37 C Lens Tem • Displays transducer L/R Flip WD Flip U temperature Full Size Trapezoid Dual Split 12 cm Clear Delete DTI THI DICE Dyn R MultiHertz Focus Tx Power TEQ Gain Edge Focus Nu ..... Off Position Low Map Focus Nu .... Persist Focus Posi .... 65 dB 5.0 MHZ Tint Focus Posi ... 13 Unrestricted © Siemens Healthineers 2022 Speaker Notes: A scan plane indicator is on the imaging screen and displays the rotation angle of the scan plane. As the array orientation changes, the on-screen scan plane icon updates to indicate the relative direction of the array and the numerical value of the rotation angle. The starting angle should always be 0°. A temperature indicator is also located on the imaging screen and displays the current temperature of the transducer. Notes No. 13 SIEMENS Healthineers Transducer controls and operation SIEMENS. Healthineers ... When the transducer temperature is 37°C or above, the system updates the value and color of the temperature < 37ºC Lens Temp indicator displayed on the screen Temperature Indicator Color Indicator Lens Temperature Range < 37°C Gray Below 37°C Actual lens temperature Yellow 37 – 40.9°C Actual lens temperature Orange 41 – 42.9°C 43°C Red 43°C >43°C Red Above 43°C 14 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The following chart displays the changes the color indicator makes to reflect correlating changes in the lens temperature displayed on screen. Notes No. 14 SIEMENS Healthineers Transducer controls and operation SIEMENS. Healthineers ... Thermal management When the transducer temperature reaches 42°C – message appears with option to reduce transmit power or continue imaging • Once transducer cools to 41°C the transmit power resets When temperature reaches 43°C – imaging is suspended • Disconnect the transducer and reconnect once it has cooled TIP: If the transducer begins to increase in temperature, de-activate any imaging mode other than B-mode and freeze the image to attempt to reduce the temperature. 15 Unrestricted © Siemens Healthineers 2022 Speaker Notes: The system will use the following methods for thermal management of the transducer: • When the transducer temperature reaches 42°C a message appears with the option to reduce the transmit power or to continue imaging. Once the transducer cools to 41°C the transmit power resets. • When the temperature reaches 43°C imaging is suspended. The transducer must be disconnected and then reconnected once it has cooled. (Refer to the user manual, Chapter D3 in the Clinical Applications Guide for proper handling with overheating.) TIP: If the transducer begins to increase in temperature, de-activate any imaging mode other than B-mode and freeze the image to attempt to reduce the temperature. Notes No. 15 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Transducer and connection SIEMENS • Discuss transducer controls and operation • Review care and cleaning SIEMENS 16 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Finally, we will review care and cleaning of the transducer. Notes No. 16 SIEMENS Healthineers Approved cleaners and disinfectants SIEMENS. Healthineers ... https://siemens-healthineers.com/ultrasound/ultrasound-transducer-catalog#Technology SIEMENS. Healthineers Global Products & Services Support & Documentation Insights About Us Home > Medical Imaging > Ultrasound Machines > Ultrasound Transducers Ultrasound Transducers Technology Cleaners and Disinfectants Care Specifications > Continue to Global TIP: Clear the internet browser cookies to ensure the most current data is loaded 17 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To view the complete list of approved cleaners and disinfectants for the 5VT transducer, go to the Ultrasound Transducers webpage through the link provided here. • To ensure loading the most current data, clear your internet browser cookies before launching this webpage • Select “Continue to Global” • Scroll down to “Cleaners and Disinfectants” • Press “Cleaners and Disinfectants” to view or download list Note: The use of any disinfectants other than those specified here may damage the transducer and, as a result, may create electrical hazards for patients and/or users. Notes No. 17 SIEMENS Healthineers Care and cleaning SIEMENS. Healthineers ... To clean the transducer 1. Disconnect and remove from the ultrasound system 2. While wearing protective gloves, remove and dispose of the transducer sheath 3. Select an approved cleaner and clean the distal tip and flexible shaft up to the 100 cm mark 4. Use clean gauze pads dipped in a mild soapy solution to wipe the cable, handle, articulation controls, and connector 5. Rinse the distal tip and flexible shaft 6. Clean the handle with a pad moistened in 70% isopropyl alcohol 7. Disinfect the transducer 18 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To clean the transducer: 1. Disconnect and remove from the ultrasound system. 2. While wearing protective gloves, remove and dispose of the transducer sheath. 3. Select an approved cleaner and clean the distal tip and flexible shaft up to the 100 cm mark. 4. Use clean gauze pads dipped in a mild soapy solution to wipe the cable, handle, articulation controls, and connector. 5. Rinse the distal tip and flexible shaft. 6. Clean the handle with a pad moistened in 70% isopropyl alcohol. 7. Disinfect the transducer. Notes No. 18 SIEMENS Healthineers Care and cleaning SIEMENS. Healthineers ... To disinfect the transducer 1. Submerge distal tip and flexible shaft in approved disinfectant *Do not immerse the transducer more than 100 cm above the distal tip 2. Carefully follow the disinfectant manufacturer’s instructions for high-level disinfection 3. Dry the transducer with gauze pads 4. Apply a Siemens Healthineers approved disposable tip protector before storage 5. Store the disinfected transducer in the original shipping case only after disinfecting 19 Unrestricted © Siemens Healthineers 2022 Speaker Notes: To disinfect the transducer: 1. Submerge distal tip and flexible shaft in approved disinfectant. Do not immerse the transducer more than 100 cm above the distal tip 2. Carefully follow the disinfectant manufacturer’s instructions for high-level disinfection 3. Dry the transducer with gauze pads 4. Apply a Siemens Healthineers approved disposable tip protector before storage 5. Store the disinfected transducer in the original shipping case only after disinfecting Notes No. 19 SIEMENS Healthineers Summary SIEMENS. Healthineers ... • Transducer and connection SIEMENS • Discuss transducer controls and operation • Review care and cleaning SIEMENS 20 Unrestricted © Siemens Healthineers 2022 Speaker Notes: In summary, the following topics have been covered: • Transducer and connection • Discussion of transducer controls and operation • Review of care and cleaning Notes No. 20 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS. Healthineers ... Questions? 21 HOOD05162003266671 Unrestricted © Siemens Healthineers 2022 Speaker Notes: Questions? Notes No. 21
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- Interventional Cardiology
- Interventional Radiology
- Critical Care
- Liver Disease
- Oncology
- Surgery
- Urology
- Ultrasound
- POC
- Point of Care
- Trauma
- FAST
- eFAST
- BLUE
- FOCUS