
ACUSON Origin Text, Body Marker, Arrow Presentation
This content explains how to use the Text, Body Marker and Arrow feature on the ACUSON Origin system at software level 2.0.
SIEMENS Healthineers SIEMENS Healthineers .. ACUSON Origin Ultrasound System Text, Body Marker and Arrow 2.0 software version 1 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No Speaker notes. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality O 2 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 2 SIEMENS Healthineers Accessing Text SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Patient Title Text Imaging Review RIGHT SAG PROX CCA JUGULAR Report LEFT TRV MID BULB SUBCLAVIAN End Exam DIST BIFURCATION ICA ECA VERTEBRAL Clear Screen Select Line Text Size Home Set Home 3 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To access the Text Feature, press the ABC key on the left side of the Control Panel. The text will be highlighted in orange on the Touch Screen. Note: If the Body Marker or Arrow feature was used last, they will be displayed on the Touch Screen and will require you to select the Text tab. Notes No. 3 SIEMENS Healthineers Text Touch Screen SIEMENS . Healthineers' ... System Configuration Hide Words Text Body Marker Arrow Exam Package Tab Menu Carotid Exam Packages Patient Title/Text Title Text RIGHT CCA Virtual Keyboard Imaging Active Text Review RIGHT SAG PROX CCA JUGULAR Report LEFT TRV MID BULB SUBCLAVIAN End Exam DIST BIFURCATION ICA ECA VERTEBRAL Text Functions Clear Screen Select Line Text Size Cine Home Set Home Next page 4 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Once Text is activated, the Touch Screen displays the Text features. Tab Menu: This allows you to cycle between Text, Body Marker or the Arrow feature. Title/Text: Allows the user to choose a Title or Text annotation. System Configuration: Select the Configuration icon to access the configuration menu to customize the display of the text on the Touch Screen. Keyboard: Select the keyboard icon to activate the virtual keyboard for manual typing of text. Select keyboard icon a second time to return to the previous screen of pre-defined text options. Hide Words: Temporarily removes Text and Title annotations from the Image Screen to take an image (e.g. teaching file). Select Hide Words icon a second time to regain text access. Exam Package: (Text Annotation Packages) - Provides access to any pre-defined text from any Exam Package. Custom Text Annotation packages may be created in the System Configuration menu. The following actions adjust using the soft keys on the Control Panel as shown on the Abdomen exam text. • Clear Screen - Clears all “Text” on the Image and Touch Screen (also clears Measurements, Body Markers or Arrows). • Select Line - Returns the cursor to last text entered. • Text Size - Changes the size of all text and title annotations on the imaging screen. • Home - Moves the text cursor to the Home set position. • Set Home - Sets the desired location for text to appear on the Image Screen. The Delete key on the Control Panel removes a single word in a text line. It will delete the last word that was entered or, you can move the cursor into the word you wish to delete and then press Delete. Note: If no text is entered, Delete Line and Previous Application will be grayed out. Notes No. 4 SIEMENS Healthineers Text annotations SIEMENS . Healthineers ... Text Body Marker Arrow pam Packs Carotid Text Body Marker Arrow xam Package Patient Patient 1 Imaging Title Text Title Text Imaging Review 1 RIGHT SAG PROX CCA JUGULAR Review RIGHT MCA MT ACOA Report LEFT TRY MID BULB SUBCLAVIA Report LEFT MCA M2 PCOM End Exam DIST BIFURCATION End Exam ACA AT OPTHALMICA 3 2 CA ACA A2 BASILARA FCA PCA PT VERTEBRAL A VERTEBRAL PCAP2 ICA Clear Screen Select Line Text Size Cine Home Set Home Clear Screen Select Line Text Size Home Set Home .. D. 5 Unrestricted © Siemens Healthineers 2024 Speaker Notes: 1. The Title feature allows the user to enter an annotation that will remain on the imaging screen in many scenarios. To use Title: a. Select Title b. Enter the desired label(s) c. Select Text to return to the text function. The Title is not removed from the screen when the “Clear Screen” or “Delete” keys are selected while in “Text” mode. This feature is useful in carotid exams. The user can enter the title “Right or Left” and continuously change or clear the anatomical text without affecting the title. 2. There are multiple preconfigured text groups available for customization as shown in this example of the Carotid package. Additional groups may be added and may be customized to the user preference. 3. An Additional Text group is also available, seen arranged vertically but separated by spaces, as shown in the Transcranial Doppler package and may be customized. This text group will add to the line of text rather than replacing text. Note: Additional text is not preconfigured for all types of exams and will need to be customized. Only one word can be selected per vertical group or field of text in a consecutive line. Notes No. 5 SIEMENS Healthineers Text exam package SIEMENS . Healthineers ... Exam Package Exam Package Carotid Carotid Patient Cardiac Abdomen Breast Carotid Early OB Fetal Echo Imaging GYN Ped Hip LEA LEV MSK Neo Head Review Report OB pediatric Abdomen Pelvis Penile Prostate Renal End Exam TCI Testis Thyroid UEA UEV Clear Screen Edit Caliper [Select Cine Hide Results 6 Unrestricted © Siemens Healthineers 2024 Speaker Notes: During an exam, to access text from another text annotation package, select Exam Package on the Touch Screen while in Text mode. A list of all exam types is displayed. This is especially useful when in arterial or venous imaging of the extremities. You can quickly annotate venous and arterial vessels as you do the exam. Select the desired package from the Touch Screen to access the stored text. Notes No. 6 SIEMENS Healthineers Using the Text feature SIEMENS. Healthineers ... Text Body Marker Arrow Exam Package Abdomen 501 Abdomen TIB:0.20 Patient TIC:1.12 Text RIGHT SAG AORTA TIS:0.20 Title MI:1.38 Imaging 23fps 95% 2D Review H Mid RIGHT SAG PANCREAS AORTA PROX LATERA 0dB/DR65 c=1540 Report Compound LEFT TRV LIVER IVC MID LLD End Exam MIDLINE GB KIDNEY DIST CBD SPLEEN SUP HEPATIC V INF PORTAL VEIN MEDIAL Select Line ext Size Cine RIGHT SAG AORTAI Clear Screen Home Set Home 7 Unrestricted © Siemens Healthineers 2023 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Once the Text feature is activated, the Touch Screen displays the pre-defined text. Available text on the Touch Screen is white and becomes orange when selected. Active text on the image screen is teal and becomes yellow when set. To change text, select a different word and it will replace the existing text (text replace fields only). Temporarily hide annotations by selecting the Show/Hide control. Note: The control color is orange when text is hidden. To redisplay hidden text, select the Show/Hide control again Only one word from each group or field can be selected in a consecutive line of text. Notes No. 7 SIEMENS Healthineers Entering manual text SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Abdomen Patient Title Text RIGHT SAG AORTA Imaging Review Report End Exam 5 6 8 19 O x Tab Q W E R U O Caps Lock A S D F G K L Enter I .. .. Shift Z X C B IN M Delete - N Ctrl Alt #+- Clear Screen Select Line Text Size Cine Home Set Home 8 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To manually enter text using the virtual keyboard, press the ABC key on the Control Panel, then select the Keyboard icon on right side of the Touch Screen. Use the cursor or select a letter on the Touch Screen. When Caps Lock is on, it is orange in color. When Caps Lock is off, the key is gray. The default is Caps Lock off. If Auto-Complete is stored in the System Configuration (Configuration > Annotation> Text), the system displays a matching phrase from the exam-specific library of text annotations based on the first few letters entered and it is displayed in orange. • To accept, select the Tab key. • To delete, press the Delete key on the Control Panel. • Press the space bar to remove the pre-defined text or continue typing. Once it is completed, if you roll the trackball to the end of the word and backspace, the auto- complete word will re-appear for easy editing. Notes No. 8 SIEMENS Healthineers Entering text with optional retractable keyboard SIEMENS . Healthineers ... 9 Unrestricted © Siemens Healthineers 2024 Unrestricted © Siemens Healthineers 2023 Speaker Notes: The system has an optional retractable keyboard. To type manual text, press Text Start (space bar). Notes No. 9 SIEMENS Healthineers Moving and editing text SIEMENS. Healthineers ... 10L4 10L4 Vascular Access Vascular Access TIS:0.35 TIS:0.35 MI:1.20 MI:1.20 26fps 26fps 95% 95% 2D H Mid H Mid 6dB/DR65 6dB/DR65 c=1540 C=1540 LD 1 LD 1 Compound RIGHT RADIAL ARTERY Compound UA 2 UA 2 MapE/T5 MapE/T5 P2 P2 c C Pen -2dB -2dB General General P3/LD1 P3/LD1 PRF 1302 PRF 1302 S2/Pr4 S2/Pr4 MapF/F3 2D + Color 2D + Colo 3cm 3cm RIGHT RADIAL ARTERY Fr1179 Fr1179 10 Unrestricted © Siemens Healthineers 2023 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Text can easily be edited, by selecting a different choice on the Touch Screen. To edit text manually, place the cursor in the desired area and backspace. To move the text, place the cursor in the text and press the Set key. The line of text becomes teal and can be moved anywhere in the image Once set, it will become yellow. Notes No. 10 SIEMENS Healthineers Overwriting Text SIEMENS .: Healthineers' ... Text Body Marker Arrow Exam Package Carotid 10. 46 Patient Title Text LEFT Imaging HHIGH C- 1540 Review RIGHT SAG CCA JUGULAR PROX Report LEFT TRV BULB UBCLAVIAN MID RF 2500 End Exam BIFURCATION DIST LEFT |SFA -- 100 ICA A. A ECA VERTEBRAL Clear Screen Select Line Text Size Home Set Home 11 Unrestricted © Siemens Healthineers 2024 Unrestricted © Siemens Healthineers 2023 Speaker Notes: To overwrite text on a stored image: 1. Select Review on the Touch Screen 2. Select the image you wish to change 3. Position the cursor before the first character of the first word to overwrite 4. Select the Overwrite Control (highlighted in Orange) on the Touch Screen 5. Use the keyboard or insert or delete characters or press the desired label from the Touch Screen. 6. Press a trackball key to confirm the text. Note: To fully overwrite existing text, the temporary label must be the same length or longer than the original text. If not, then use the space bar to space until the word is covered as shown in this example where Right was changed to Left and two spaces were added to cover the word. Notes No. 11 SIEMENS Healthineers Text customization SIEMENS . Healthineers ... System Configuration Create Package System Settings 3 > Workflow Enhancement Package Configuration Touch Screen Layout Editor > Imaging Settings AE Packages Package Name Package Name Carotid Dr. A > Measurement & Report Name Show All General 5 Annotations Body Markees All Packages Root Package Carotid 2 Text Behavior Auto Complete Features Delete text on unfreeze El Auto text compl 7 > Connectivity & Network OK Cancel > Peripheral Devices Digital 8 GYN System Management Fetal Echo Early OB MSK Neonatal Head OB Pediatric Abdomen LEA Cesite Package 4 Import Export Restore Default 12 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To create a new text package: 1. Select the System Configuration icon on the Touch Screen. 2. Select Annotation> Text. 3. Select the Package Configuration tab. 4. Select Create Package. 5. Enter a Package name and a Root package (copy) if desired. 6. Select the newly created package from the Package Configuration tab. 7. The Auto text complete option enables the system to choose to display a word found within the active Exam Package and completes it after typing the first few letters. 8. The Delete Text on Unfreeze option activates the removal of all on-screen text after unfreezing the image. Notes No. 12 SIEMENS Healthineers Text customization SIEMENS . Healthineers ... System Configuration System Settings Workflow Enhancement Package Configuration Touch Screen Layout Editor 6 Imaging Settings Text Annotation Package > Measurement & Report Annotations Cardiac 5 1 Body Markers Text 2 3 RIGHT PV LA TRANS PLAX LVOT Features INC CORONAL RVOT ? Transducer LEFT LV PSAX Connectivity & Network RA SVC › Peripheral Devices A4C 2.CH System Management RV 4 MV ASC 4 CH PA AV A2C APEX TV SAG A3C AORTA 7 New Page Delete Page Restore Defaults : Candiac 13 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To customize the Touch Screen appearance of the text menu: 1. Enter System Configuration > Annotations > Text > Touch Screen Layout Editor 2. Select the desired Text Annotation Package. 3. Position the cursor in any text box to add / replace the text label. 4. Select Add Text Group to add a new text group or replace group. 5. Select Add Text to add a new additional text group (non text replace). 6. Use the controls at the top of each group to reposition the group (< / >), delete the group (X) or add or remove columns within the group (+ / - ). 7. Select New Page to add an additional page of text annotations or Delete Page to remove additional pages. Notes No. 13 SIEMENS Healthineers Text customization SIEMENS. Healthineers ... Text Jody Marker Arrow Exam Package ECHOLC Patient 71fps Title Text 100% Imaging 2D H High 2dB/DR65 Review c=1540 RIGHT PV LA TRANS PLAX LVOT LD 1 UA 2 Report MapE/T3 LEFT IVC LV ORONAL PSAX RVOT P1 End Exam RA SVC AO A4C 2 CH RV ABCDEFGHIUKLMN OPQRSTUVWXYZ ... ASC 4 CH PA AV A2C APEX TV SAG A3C AORTA 16cm ABCDEFGHUKLMNOPQRSTUVWXYZABCD Clear Screen Select Line Text Size Cine Home Set Home 14 Unrestricted © Siemens Healthineers 2023 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Additionally, you can program long single lines of text (30 character maximum). Note: approximately 26 characters will be displayed on the Touch Screen (depends on width of character), but the entire word will be on the image. In this example, there are 30 characters displayed on the image. Multiple words can also be used with spaces and will not be affected by auto complete configuration. Notes No. 14 SIEMENS Healthineers Objectives SIEMENS Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality C 15 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 15 SIEMENS Healthineers Accessing Body Marker SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package TCI Patient Imaging (CEUS) Review Report End Exam U1 ABC Delete Clear Screen Trackball Transducer Marker Transducer Marker Cine On 16 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To access the Body Markers, press the ABC key on the left side of the Control Panel. On the Touch Screen, select the Body Marker tab. This is an example of the Transcranial Body Marker selections. Notes No. 16 SIEMENS Healthineers Body Marker examples SIEMENS . Healthineers ... Touch Screen Text Body Marker Arrow Exam Package GEA Text Body Marker Arrow Exam Package Cardiac Patient Patient Imaging Imaging Review Review Report Report End Exam End Exam Clear Screen Trackball Transducer Marker Cine Clear Screen Trackball Transducer Marker Transducer Marker On Transducer Marker On 17 Unrestricted © Siemens Healthineers 2024 Speaker Notes: This is an example of the Upper Extremity Arterial (UEA) and Cardiac Body Marker selections. Notes No. 17 SIEMENS Healthineers Body Marker Touch Screen layout SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Carotid Tab Menu Patient Imaging Oo Review Report Transducer Delete End Exam Widget Clear Screen Trackball Transducer Marker Transducer Marker On Soft Keys 18 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The tab menu is highlighted in orange when the Body Marker is activated. The active exam body markers are displayed. The soft key functions include: • Clear Screen - deletes all Body Markers, Text and Arrows displayed on the image screen. • Trackball - allows two different functions: • Body Marker: activates the Body Marker so that it can moved • Transducer Marker: activates the transducer marker so that it can be moved • Press the soft key or Touch Screen to alternate between the two options • Body Marker - activates the Body Marker on the image screen • Transducer Marker - turns the Transducer Marker on and off The transducer widget allows movement and rotation of the Transducer Marker. Place your finger or cursor in the orange circle or Transducer Marker and move to the desired location. When in the Body Marker tab, pressing the Delete key on the Control Panel removes the Body Marker from the image screen without removing Text or Arrows. Notes No. 18 SIEMENS Healthineers Selecting Body Markers SIEMENS ... Healthineers ... Text Body Marker Arrow Exam Package 10L4 Carotid TIS:0.87 Patient MI:0.38 16fps 95% Imaging Do 2D OO H Mid Review -4dB/DR60 c=1540 LD 1 Report Compound UA 2 MapC/T5 End Exam OdB PRF 3125 23mm PW Low RIGHT ICA MID -100 GS 1.5 RF 5000 F 60 Clear Screen Trackball Body Market Transducer Marker - cmls ....... 50 19 Unrestricted © Siemens Healthineers 2024 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Once you have pressed the ABC key on the Control Panel, the Touch Screen displays the active exam as shown in the left screen. To choose a Body Marker, select the choice on the Touch Screen. The Body Marker is displayed from the last position as shown in the image. To move the body marker location, push the soft key labeled Body Marker and the Body Marker becomes active (orange), then use the trackball to move to the desired location. To activate the transducer marker, push the rotary control Transducer Marker to the “On” position. To reposition / rotate the Transducer Marker: • Drag the orange dot on the Touch Screen to change the orientation of the transducer marker • Drag the transducer marker to change the location of the transducer marker To delete a Body Marker from the image screen, press Delete on the Control Panel. To add a Body Marker from another application, select Exam Package and select the desired exam and make the selection on the Touch Screen. To remove all Text, Arrows, and Body Markers from the image screen, select Clear Screen on the Touch Screen. To exit the Body Marker function, press the ABC key on the Control Panel. Notes No. 19 SIEMENS Healthineers Body Marker configuration SIEMENS. Healthineers ... System Configuration System Settings 3 Workflow Enhancement Package Configuration Touch Screen Layout Editor Imaging Settings Body Marker Package Package Name 1 Measurement & Report Name Show Allv Cardiac Annotations Abdomen 2 6 Body Markers Carotid All Packages 5 ? Text Cardiac Body Marker Behavior Create Package Features Breast [] Delete Body Markers on unfreeze 7 ›Transducer Digital Carotid Dr. A Connectivity & Network GYN Package Name Fetal Echo Root Package Peripheral Devices Carotid System Management Early OB MSK OK Cancel Neonatal Head Pediatric Abdomen LEA LEV 4 Create Package Delete Import Export 20 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To create a new Body Marker package: 1. Select the System Configuration icon on the Touch Screen. 2. Select Annotation> Body Markers. 3. Select the Package Configuration tab. 4. Select Create Package. 5. Enter a Package name and a Root package (copy) if desired. 6. Select the newly created package from the Package Configuration tab. 7. The Delete Body Markers on unfreeze option activates the removal of all body markers after unfreezing the image. Notes No. 20 SIEMENS Healthineers Other Body Marker configuration SIEMENS . Healthineers ... System Confapuration Package Configuration Touch Screen Layout Editor · System Settings . Workflow Entascument Package Configuration 1 Body Marker Package Testis 2 . Measatercerc & Sport CarElas Body Marker Library . Annotaports Eixoy Mamans dy Maker library Henal 3 Features Transducer 5 6 > Connectivity & Network · Peripheral Devices System Management 4 New Tage 8 7 New Page 21 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To configure the body marker menu Touch Screen layout: 1. Select System Configuration > Annotation > Body Marker > Touch Screen Layout Editor. 2. Select the desired Body Marker Package you wish to edit from the drop-down menu. 3. Select the desired Body Marker Library you wish to add from. 4. Select the desired Body Marker from the available options. 5. Select the desired location to place the body marker. 6. To remove a body marker from the Touch Screen, select the desired body marker and select the box labeled “Click here to remove”. 7. Selecting New Page on the Touch Screen adds a second page where additional body markers can be added. 8. The Restore Defaults key deletes the customized body marker selections and restores the factory default settings. Notes No. 21 SIEMENS Healthineers Objectives SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality O 22 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 22 SIEMENS Healthineers Accessing Arrow feature SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Patient imaging Review Report End Exam ABC Clear Screen Previous Arrow 23 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To access the Arrow feature, press the ABC key on the left side of the Control Panel. Next, select the Arrow tab from the Touch Screen. Notes No. 23 SIEMENS Healthineers Using the Arrow feature SIEMENS . Healthineers ... Text Body Marker Arrow Exam Package Patient Imaging Review CORONARY ARTERY Report End Exam Add Arrow Clear Screen Previous Arrow Position Tail 24 Unrestricted © Siemens Healthineers 2024 Unrestricted © Siemens Healthineers 2023 Speaker Notes: Access the Arrow function by pressing the ABC key on the Control Panel. On the Touch Screen, select the Arrow tab and the active arrow displays in orange. Clear Screen clears all arrows. (This will also delete all text and measurements on the screen). To delete just the arrows, press the Delete key on the Control Panel to delete one arrow at a time. Hold down for 1.5 seconds to clear screen. There are two ways to increase the length of the arrow: • Drag the tail of the arrow on the Touch Screen to increase/ decrease the size of the tail. • Use the trackball and Set key to position and increase/ decrease the size of the tail. • The image above to the right shows the minimum and maximum length of the tail. To add Arrows, press the Update key on the Control Panel. To move between arrows, press Previous Arrow on the soft key on the Control Panel or on the Touch Screen. To rotate or angle the arrow, drag the tail of the arrow on the Touch Screen widget to change the direction. Notes No. 24 SIEMENS Healthineers Summary SIEMENS . Healthineers ... • Outline Text functionality and customization • Review Body Marker functionality and customization • Describe Arrow functionality O 25 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 25 SIEMENS Healthineers Trademarks and disclaimers SIEMENS . Healthineers ... ACUSON Origin is a registered trademark of Siemens Medical Solutions USA, Inc. O 26 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 26 SIEMENS Healthineers Trademarks and disclaimers The products/features mentioned in this document may not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. ACUSON O r i g in i s a trademark of Siemens Medical Solutions USA, Inc. At Siemens Healthineers, our purpose is to enable healthcare providers to increase value by empowering them on their journey towards expanding precision medicine, transforming care delivery, and improving patient experience, all enabled by digitalizing healthcare. An estimated five million patients worldwide everyday benefit from our innovative technologies and services in the areas of diagnostic and therapeutic imaging, laboratory diagnostics and molecular medicine as well as digital health and enterprise services. We’re a leading medical technology company with over 120 years of experience and 18,500 patents globally. With over 50,000 employees in more than 70 countries, we’ll continue to innovate and shape the future of healthcare. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-heathineers.com/ultrasound 27 Unrestricted © Siemens Healthineers 2024 Notes No. 27 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS . Healthineers ... Questions? 28 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 28
- Origin
- text
- annotation
- body marker
- arrow
- keyboard
- overwrite
- configuration