ACUSON Origin 2.0 Stress Echo Quick Card
This content explains the basic functions on the ACUSON Origin system Stress Echo option at software level 2.0.
Quick Reference Card Stress Echo Treadmill Continuous Capture ACUSON Origin Ultrasound System siemens-healthineers.com/ultrasound Step 1 System Configuration Step 3 Select System Configuration • Select the desired Stress Echo Protocol • on the Touch Screen, then select Patient Features > Stress Echo to set-up Pharmacology €? PISA specific Stress Echo parameters • Select Patient on the Touch Screen jf Treadmill Mitral Stenosis Tip: Patient ID is required to begin Bicycle Aortic Stenosis an exam. Regurgitant Volu me Step 2 5V1 Cardiac • Select the cardiac transducer (5V1, 5Z1, 8V3, 10V4) Stress Echo • Select Stress Echo from the Workflow tab SIEMENS Healthineers . Step 4 • Region of interest (ROI) appears on the image • ROI position / size can be modified Tip: Select the left or right Set key to adjust position / size. To adjust the 2D image, select the 2D tab on the Touch Screen, then press the Stress Echo tab to start acquisition. Position Sbe Step 5 • To begin acquisition of Rest images, select Capture FO Capture • If the Rest configuration is set to Enter Selection – 16 ª after View Capture, select one or multiple images Rest by double-clicking with the left / right Set key View Acquired Selected PLAX Tip: Views are color coded in the Rest / Post Navigation Panel. PSAX 4 A4C 12 A2C • If selecting multiple images, single-click each image X and double-click the last selection to advance to the next view Tip: Selected images will be outlined with a teal box; images not selected will have a red X. • If necessary, press Update to Rename view Rename View PLAX PSAX A4C A2C Pointer • Select Reject on the Touch Screen to acquire new images for the current view if needed Selection Compare Accept Selected Accept All Defer Selection Add Reject 2 siemens-healthineers.com/ultrasound • After the last view has been selected, it will automatically advance to the next stage or you can manually select on the Touch Screen Stage Rest • The Navigation Panel displays how many images have been acquired Rest 16 and selected for each view view Acquired Selected PLAX PSAX 4 A4C 4 AZC Step 6 Post 24 A Acquired • To acquire Post images (in continuous capture configuration), repeat Selected the same steps that were performed in the Rest stage. PLAX 6 12 PSAX A4C 5 ADC 4 • Advance to the next view by pressing the Update Key on the control panel or selecting the view from the Touch Screen Next View PLAX • To end capture, select Capture on the final view FAX Position Size • Pause protocol if additional imaging outside of the protocol is needed To select Post images, repeat the same steps that were performed in Pause Protocol • the Rest stage Tip: A guide on the touch screen display current view high-lighted in orange. Step 7 By View By Stage • In Stress Echo Review Mode selected images can be viewed • Select Sort By View or By Stage Compare option is available lay Sort • By View EDI Step 8 Exam Review Wall Motion Exam Review is available to view all images including those acquired Scoring • outside of the stress protocol • Wall Motion Scoring (WMS) is available to score individual segments and will display in the report Step 9 End Protocol • Select End Protocol on the Touch Screen to end the stress protocol Tip: Upon exit from the application, a standard imaging screen will be displayed. If desired, capture non-stress images. siemens-healthineers.com/ultrasound 3 For the proper use of the software or hardware, please always use At Siemens Healthineers, we pioneer breakthroughs in healthcare. the Operator Manual or Instructions for Use (hereinafter collectively For everyone. Everywhere. By constantly bringing breakthrough “Operator Manual”) issued by Siemens Healthineers. This material is innovations to market, we enable healthcare professionals to deliver to be used as training material only and shall by no means substitute high-quality care, leading to the best possible outcome for patients. the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest Our portfolio, spanning from in-vitro and in-vivo diagnostics version of the software and hardware available at the time of the to image-guided therapy and innovative cancer care, is crucial training. The Operator Manual shall be used as your main reference, for clinical decision-making and treatment pathways. With our in particular for relevant safety information like warnings and strengths in patient twinning, precision therapy, as well as digital, cautions. data, and artificial intelligence (AI), we are well positioned to take on the biggest challenges in healthcare. We will continue to build Note: Some functions shown in this material are optional and might on these strengths to help fight the world’s most threatening not be part of your system. diseases, improving the quality of outcomes, and enabling access to care. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not We are a team of 66,000 highly dedicated employees across more (yet) be commercially available in your country. Due to regulatory than 70 countries passionately pushing the boundaries of what’s requirements, the future availability of said functionalities in possible in healthcare to help improve people’s lives around the any specific country is not guaranteed. Please contact your local world. Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Origin is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700014399 · 14074 1024 online only · ©Siemens Medical Solutions USA, Inc., 2024
- Origin
- Echo
- Stress Echo
- Measurements
- Contrast