ACUSON Origin 2.0 Auto Intima-Media Thickness (IMT) Quick Card

This content explains the basic functions on the ACUSON Origin system Intima-Media Thickness measurement feature at software level 2.0.

Quick Reference Card Auto Intima Media Thickness (IMT) with Preview Function ACUSON Origin ultrasound system (2.0) Using Auto IMT with preview function will help to establish risk profiles, and to classify patients with intermediate vascular disease. ... -- -- ---- -- --- -- SIEMENS Healthineers Step 1 – Per Label Configuration System Settings • Go to System Configuration Workflow Enhancement > Measurement & Report > Measurement Imaging Settings > Per Label Configuration Tab Measurement & Report > Select Carotid exam type > Select Label to edit Measurement > Select default Tool and Method > Select Output values to Show Touch Screen Measurement Config > Select Display Units & Precision Custom Measurement Label Report OB Tables Carotid Dist CCA IMT Max Min Max Last Average Output Show Unit Precision C10 mm 0.00 Max mm V 0.00 Mean mm V 0.00 Min mm V 0.00 Step 2 10L4 Carotid • Select compatible transducer1 and Carotid exam preset Step 3 – Acquire Images2 • Acquire image of distal carotid artery and bulb • Ensure the vessel image is perpendicular to the Freeze ultrasound beam and clearly shows the intimal lining • Press Freeze 1 Auto IMT with preview function is compatible with all linear transducers and the carotid preset. 2 Imaging protocols may vary between institutions. 2 siemens-healthineers.com/ultrasound Step 4 – Measurement • Select Measure on the control panel • Select an IMT measurement from touch screen x ... x Measure Dist CCA IMT Step 5 – ROI • Roll trackball to position the dotted reference line and the ROI (region-of-interest) • Ensure the ROI is over a section of the posterior wall of the CCA Step 6 – Preview Mode • Press the Update (Preview) key on the control panel Update to enter the preview mode • Note the on-screen home base reference guide • Two lines will appear showing the tracings • The anterior tracing will be teal and the posterior tracing will be yellow Preview • Use the trackball to readjust the ROI position as needed, and the prior tracings will disappear Set Set • Press Update (Preview) to enter Preview mode again Cal 1 • Press either Set key to enter Edit mode siemens-healthineers.com/ultrasound 3 Step 7 – Edit Mode • The more anterior trace will now remain teal, indicating the trace to be edited • The non-editable trace will be yellow • Move the tiny cursor and use either Set key to adjust the tracing of the line • Move the cursor towards the posterior tracing and that line will turn teal • Use either Set key to adjust the tracing of the line End Set Set Edit Step 8 – Save Measurements To enter measurement into report: Update • Press Capture to store the image and enter the measurement into the report or ºO • Press Update (End) to enter the measurement Capture into the report 4 siemens-healthineers.com/ultrasound Step 9 – Reports Report • Press Report on the touch screen • The values seen will be the method Intima Media Thickness (IMT) chosen under the per measurement configuration tab Value Rt Dist CCA IMT Mean 0.96 mm Max 1.25 mm Step 10 – Edit Report Intima Media Thickness (IMT) • Once in Report, users can delete individual measurements or change the displayed Mean Max Method method in the Report.3 Rt Dist CCA IMT 0.96 mm 1.25 mm Max • To delete a measurement, select the X next to a measurement 0.96 1.25 X 2 0.62 0.74 X • The drop-down method choices include: Last, Avg, Min, Max and the option to choose any of the prior individual Method measurements • Select Summary on the touch screen or monitor to display the measurement Max summary page Last • Select Edit Report to return to report Avg editing features Min • Pressing Store Report will automatically save images of all report pages to the Max hard drive - 2 3 Summary Edit Report 3 When the method chosen is Avg, only the Mean measurement is displayed in the report summary. Max and Mean are displayed in the summary report for all other methods. siemens-healthineers.com/ultrasound 5 For the proper use of the software or hardware, please always use At Siemens Healthineers, we pioneer breakthroughs in healthcare. the Operator Manual or Instructions for Use (hereinafter collectively For everyone. Everywhere. By constantly bringing breakthrough “Operator Manual”) issued by Siemens Healthineers. This material is innovations to market, we enable healthcare professionals to deliver to be used as training material only and shall by no means substitute high-quality care, leading to the best possible outcome for patients. the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest Our portfolio, spanning from in-vitro and in-vivo diagnostics to version of the software and hardware available at the time of the image-guided therapy and innovative cancer care, is crucial for training. The Operator Manual shall be used as your main reference, clinical decision-making and treatment pathways. With our strengths in particular for relevant safety information like warnings and in patient twinning, precision therapy, as well as digital, data, and cautions. artificial intelligence (AI), we are well positioned to take on the biggest challenges in healthcare. We will continue to build on Note: Some functions shown in this material are optional and might these strengths to help fight the world’s most threatening diseases, not be part of your system. improving the quality of outcomes, and enabling access to care. Certain products, product related claims or functionalities described We are a team of 66,000 highly dedicated employees across more in the material (hereinafter collectively “Functionality”) may not than 70 countries passionately pushing the boundaries of what’s (yet) be commercially available in your country. Due to regulatory possible in healthcare to help improve people’s lives around the requirements, the future availability of said functionalities in world. any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Origin is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700015425 · 14164 0923 online only · © Siemens Medical Solutions USA, Inc., 2024

  • Origin
  • Vascular
  • Carotid
  • CIMT
  • IMT
  • Calculations
  • Measurements