ACUSON Origin 2.0 2D Heart AI Quick Card
This content explains the basic functions on the ACUSON Origin system 2D Heart AI option at software level 2.0.
Quick Reference Card 2D HeartAI ACUSON Origin ultrasound system (2.0) 2D HeartAI is an AI-powered chamber quantification software for all four heart chambers and includes strain, volume, and function analysis. 2D HeartAI is available on images with or without an ECG and contrast images of the left ventricle. Step 1 Multiple Select Step 2 2D Heart AI • Enter Review and choose • Select 2D HeartAI Multiple Select from the LV Peak Systolic Strain [%] • Bullseye View is default touch screen Compare layout Anterior Choose optimized apical 4, 2, Select a segment on -17 20 • • and 3 chamber images bullseye to remove if 21 Note: The first image is automatically needed Lateral selected upon entering Review. Ensure Septal that only the necessary apical 4, 2, -23 19 and 3 chamber images are selected. 32 11 -20 Inferior SIEMENS Healthineers . Step 3 Step 6 Delete Contour RV LV • Select/ deselect chambers for • Select Delete Contour to analysis when available remove current contour RA LA • Manual placement points will become active Note: Follow the on-screen guide for Step 4 placement of three points. • Hide/Show Segment Values – hides / shows values for segments within each viewport O Step 7 • Edit Contours – activates ED-ES View for Beats Analyzed editing Select Beats Analyzed – 2 • • Delete View – deletes selected view up to five (cannot be undone) • Select Average Result to Average Result X • Single View – activates results summary average multiple beats for selected view • Select Exclude Beat to remove v • Bullseye View – select to return to the current beat from averaged Exclude Beat bullseye summary results Step 5 Step 8 LV Epi • Select Edit Contours to enter • Select LV Epi to activate the ED-ES View (ED-ES View can LV epicardium contour and also be accessed from the Bullseye View obtain LV mass Single View layout) • Click inside of ED or ES viewport to edit contours (edits can only Step 9 be performed on the ED and ES frames) • Select Timing / Phase results displayed • Move cursor closer to edit a • Select Curve results displayed smaller portion Peak Systolic • Move cursor further to edit a End Systolic Strain Time to Peak Post Systolic Strain Post Systolic Strain Indexed larger portion Timing / Phase ESS • Select Bullseye View to re-analyze Note: ED-ES View is the only page in which edits can be made. Segmental Strain Strain Rate Volume Global Strain Curve Global Strain ACUSON Origin is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700015899 · 16070 1124 online only · ©Siemens Medical Solutions USA, Inc., 2024
- Origin
- Echo
- 2D
- GLS
- Strain
- Measurements