Neuro Stent Visualization VEXX - covers from VE21 to VE40
Neuro Stent Visualization (VEXX) Angiography – Application Software VExx* *Click the link below to review how to identify your system(s) software version. How to Find System Software Version 1. Perform a DynaCT Head spin with diluted contrast. The spin will open in 3D Sharing. 2. Select Menu, Storing, then Interactive Reconstruction. Segment Menu ? GX Volume Images (MPR) Measurement Segmentation REC Storing Recalculation Job List X-Ray 3. Change the VOI Size to Small and determine the area to be reconstructed with Define VOI. 4. Define VOI can be done in 2D or 3D view. a) 3D view (shown) – After changing the VOI size to Small, center the green box over the area of interest. Be sure to visualize reconstruction in both AP and Lateral by rotating the volume or using the Orientation Block to confirm the area of interest remains in the VOI box in all orientations. b) 2D View – After changing the VOI size to Small, center the green box over the area of interest in both AP (upper) and lateral (lower) segments. Use the image play buttons at the bottom of the Interactive Reconstruction box to make sure the area of interest stays in the center of the green box. Unrestricted 0 Published by Copyright © Siemens Healthineers AG 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 15 August 2025 | QR700026564 Healthineers Job Aid | Neuro Stent Visualization Effective Date: 15 August 2025 | QR700026564 Application Control 3D Sharing ?0 Application Review and Processing XE Define job list, jobs, parameters, and series name. Start interactive 3D reconstruction. Viewing Overlay General Advanced Job Layouts 3D Reconstruct. Body Region Ol Size Head & Neck Full See Step #3 Job List Voxel Size DCT Head Clear 0.49 mm Viewing Preset Define VOI in DynaCTHead D View See Step #4 Close 5. Under Job, change the Image Characteristics to Sharp. Application Control |30 Sharing ? @ Application Review and Processing XE Define job list, jobs, parameters, and series name. Start interactive 3D reconstruction. Viewing Overlay General Advanced Job youts 3D Reconstruc Reconstruction Job Parameters DCT Head Clear Nat Fill Kernel Type HU mage Characteristics Normal Motion Correction Nat Off Close Unrestricted 0 Published by Copyright © Siemens Healthineers AG 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 15 August 2025 | QR700026564 Healthineers Page 2 of 5 Job Aid | Neuro Stent Visualization Effective Date: 15 August 2025 | QR700026564 6. Select the reconstruction icon, and the new reconstruction will automatically display in 3D Sharing. Note: If the area of interest is not centered or cutoff, re-open the Interactive Reconstruc- tion box (Step 2) and adjust the area of interest by re-centering the green box over the stent. 7. After the newly created reconstruction loads into 3D Sharing, right click on the MPR and select MIP thin. VRT MIP MIP Thin IMPR MPR Thick 8. Change the slice thickness to the desired thickness in mm. Select Menu, Images (MPR), then select desired Slick Thickness. Segment Menu ? BX Volume Slice Thickness (mm) Images (MPR) 2.0 = * Measurement Segmentation Storing Image Data Selection Name X-Ray 1.3.12.2.1107.5.4.7.1012020.300000181. Unrestricted 0 Published by Copyright © Siemens Healthineers AG 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 15 August 2025 | QR700026564 Healthineers Page 3 of 5 Job Aid | Neuro Stent Visualization Effective Date: 15 August 2025 | QR700026564 9. Window the image to better visualize the stent. a) Use the middle mouse button/wheel and adjust b) Open the Preset Gallery and adjust the histogram. Preset Gallery JUNTENDO WHY HP a Analysis IR. 10 Sharing ? X JLINTENDO LICHP UDIOE 140971 Type Abdomen TUTTITITRE Abdominal Colon Tramdp. Dyna3DBody 0/ CADD 43 Dyn&CTBody EVAR vais A ATouryen Analyzis I JUNITENDO UNIVHP DynaCT Head IN FILHO VDIOE 110231 MMM 954 Shading 2:36:52 PM Less Liget O X:5143.3HU/ Y:101.09% -1220 1270 1780 04760 9700 11200 10800 10100 Blending Ok Unrestricted 0 Published by Copyright © Siemens Healthineers AG 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 15 August 2025 | QR700026564 Healthineers Page 4 of 5 Job Aid | Neuro Stent Visualization Effective Date: 15 August 2025 | QR700026564 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Copyright © Siemens Healthineers AG 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 15 August 2025 | QR700026564 Healthineers Page 5 of 5