NAEOTOM Alpha General Improvements VB10 Upgrade Video - USA
In this video, we cover the general improvements of the VB10 software for the NAEOTOM Alpha.
Product relevance: NAEOTOM Alpha.
Target group: Basic user, all users.
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required).
Welcome to this training for the Neotom Alpha General updates for the VB10 software. In this training we will discuss the new reconstruction options, then the new protocols and scan modes, and lastly the new scan parameter settings. The first section to discuss is the new reconstruction options available. With the. VB10 software. One new reconstruction option is called. Auto Kev. You may remember that depending on which scan mode you're in, all mono energetic reconstructions have a default. Kev Level. Before this upgrade, once you changed from the default, there was no way to get back to this default level without knowing which scan mode and scan parameters were being used. This is why we have now added the feature. Of auto Kev. This is a new reconstruction parameter that when selected will return you to the default. Kev. For the scan that you are using, this feature works in all scan modes such as Quantum Plus, Quantum and Quantum 10. As you can see in the video, once you change from the default, you can select the auto Kev checkbox, turning it on and returning the reconstruction back to what the default is In that particular scan mode, the next new reconstruction option is. HD field of view with. This new software upgrade. We have brought you this feature on the Neoton Alpha. HD field of view. Is located in the Reconstruction parameters under the Recon Box tab. If you. Activate HD field of view. And there is a spectral reconstruction being used. You will. See a conflict for that reconstruction. This is because HD. Field of view. Is only available as. At 3:00. D Reconstruction due to having less projections outside the standard 500 millimeters. Field of view only at 3D. Reconstruction is possible when you. Use HD. Field of. View. You can select a reconstruction up to 815mm. Field of. View. When you. Activate HD field of view. You will. See a warning message on the screen that reconstructions with. HD. Field of. View can. Lead to image. Artifacts this. Is consistent to all Siemens Health and Ears scanners when using HD. Field of view. The last reconstruction option is the. Ability. To launch reconstructions directly from My Exam Satellite. If you have purchased My Exam Satellite and the Remote Recon license, you can open a patient from the browser into the reconstruction workflow. This works the exact same way as you would do from the console. You may then make any reconstruction parameter changes including cardiac phase changes, ECG editing, and more. Once you have started the reconstruction from My Exam Satellite, the reconstruction enters the same queue for the IRS as the scanner. So if there. Are already. Reconstructions In this queue, your reconstruction will be placed in line for reconstruction. The next section of this training is the new protocols and scan modes. Let's first discuss a new scan mode available in the VB10 software. As you may know, when scanning in high pitch scan modes such as a flash scan, that high pitch with Quantum HD and Spectral was not possible. In the VB10 software we have added a new scan mode. To rectify this. We have changed the current scan mode of routine Flash, Spiral, Adult, High Res, Ultra Quantum Plus to now include full spectral information. When you use this scan mode you can have pitch values of 1.0 and up to a 3.2. To ensure full spectral information. The collimation will be 96 by 0.2mm. Just like. Before in this high pitch flash scan you will have quantum HD reconstructions. Available to you. These are reconstructions of slice thicknesses down to 0.2mm and kernel sharpnesses up to a 98. Keep in mind that these reconstructions will continue to be. At 3D. Recon only now in this new scan mode you will have full spectral results available including an SPP reconstruction. Like all other Quantum HD scan modes, any spectral reconstructions will need to be a standard Recon. This is a slice thickness of 0.4mm and kernel sharpness of 76 and below. We have kept the original version of the scan mode as you know from the VA 50 software that has no spectral results. We have just now added the keyword Y to the scan mode. This scan mode still uses the collimation of 120 by 0.2mm. The pitch values remain the same of 1 to 3.2 as before. Quantum HD results are available with slice thicknesses down to 0.2mm and kernels up to a 98 but. Only is at 3D. With this new wide scan mode, there are no spectral results available and all reconstructions will be. At 3:00. D. So please keep an eye on which scan mode you are using now. We will discuss the last section in this training the new scan parameter settings with the VB10 software. All routine Body Quantum Plus protocols will now have the. Default. KVP set to 140. This is due to having improved spectral performance and better optimized energy thresholds. Thanks to these improvements, when using 140 KVP you will have an increase of dose savings for all spectral imaging at the same image quality. Keep in mind this is for routine quantum plus protocols only. All brain protocols will remain at 100 and. 20 KVP. All quantum HD protocols will also remain at 120. KVP. This is to ensure that the iodine contrast is not reduced in the T3D reconstructions. Thank you for your attention during this training. Don't forget you can always revisit these trainings in the. Future it. May be helpful to watch these again after you're on site applications training.
80 1.20 5.00 70 75 67 65 323.44 301.34 10 11 3.20 0.25 2.46 12 0.20 13 14 15 16 17 100 140 25 105 18 SIEMENS . Healthineers NAEOTOM Alpha General Improvements VB10 Upgrade Template Effective Date: 10 Aug 2021 | HILS 2223 Effective Date: 1 Jul 2024 | QR700008108 Unrestricted I Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2024 Table of Contents New Reconstruction Options New Protocols and Scan Modes · New Scan Parameter Settings New Reconstruction Options Auto keV . A new reconstruction parameter that returns you to the default keV reconstruction. This works in all scan modes: Quantumplus, Quantum, and QuantumSn. Once the default keV value has been changed, you can select Auto keV and the default value will be selected once again. Scan Favorites General Recon Timing Config Physio Recon Contrast Scan/Recon Scan Mode CARE keV CARE Dose4D CARE keV IQ level SSDE [mGy] DLP optimized for & CARE kev CTDivol [mGy] Acquisition [mm] Pitch Thorax Non-Contrast Full (32 cm) 2.30 (15.7 cm) 5.18 Recon Favori ... Recon&GO Image Impre ... / Recon Box Auto Tasking Inline Options Slice Thickness Increment FAST Planning [mm] Inline Results Spectral Recon Window@120kV Kernel Width FAST 3D Multi Recons Thorax 5.00 Br40 Q3 cor Thorax 5.00 Br40 Q3 ax None Mediastinum Wide On Orientation ... Br40 Recon Favori ... / | General Recon / Energy [kev] General Scan CTDIvol [mGy] & CARE keV Recon Favori ... | General Recon | Recon&GO Image Height Orientation Size Front to Back Spectral Reco Axial Auto (5 ... HD FoV . With the VB10 software, HD FoV is available for the NAEOTOM Alpha. You may select it in the Recon Box tab. Image Order Matrix Coronal Head to Feet Axial . When HD FoV is activated, you will see a ble conflict if any spectral reconstruction is being Monoenergetic ... Selected spectral recon type is not compatible with HD FoV. Please change spectral recon type or switch off HD FoV. used. . HD FoV is only available for use with a T3D reconstruction. T3D Inline Results Spectral Recon Inline Results |Spectral Recon Recon Ra · HD FoV can have a recon field of view Topogram TOP 101 up to 815mm. When you activate HD FoV, a warning message about artifacts will appear. Imaging outside of the 500mm field of view may not be accurate and can lead to artifacts. This is common to all HD FoV Resureconstructions from other Siemens Healthineers scanners. mage Order Matro Center X mm Center Y HD FoVn Satellite with Remote Recon* Reconstructions will function the same as from the scanner workstation. Patient B Series Study Archived *Purchasable option Making a reconstruction is now possible from myExam Satellite. All reconstructions launched from myExam Satellite will be processed on the IRS and enter the same reconstruction queue as the scanner. Patient Browser Local Data More Filters Results (6 results, 3:02:53 PM) Patient Modality Morton, Terrance 11/03/2023 2:13:0 ... Bauer, Arnulfo 2023.11.02-10:08:47-STD-Trauma Recon New Protocols and Scan Modes New Scan Mode Flash Quantum HD with Spectral Flash Quantum HD New scan modes are now available. Flash scans with Quantum HD are now possible with full RoutineFlashSpiralAdultThoraxWideHighresultraQuantumplus RoutineFlashSpiralAdultThoraxQuantumplus full spectral information. Decision Trees · High-pitch scan mode with pitch values of 1.0 to 3.2 Collimation of 96 x 0.2mm Dose Physio Scan Rot. Exam Time Time [s] [s] Patient Instruction Instruction Post Instruction Absolute Start Command Delay [s] Delay: Actu ... Inspiration Before Scan; After S ... CH Quantum HD results with slice thickness down to 0.2mm 0.2mm and kernel sharpness up to 98 Thorax 0.20 Br98 Q3 Br98 Image Impre ... Fix Axial * Thorax - Lung off Recon Favorites Inlir e Results Monoenergetic Plus VNC lodine Pure Calcium Pure Lumen Full spectral results are available including SPP Spectral results will be in a standard reconstruction of 0.4mm slice thickness or above and kernels 76 and below msn RoutineSpiralAdultThoraxQuantumSnXcare Flash Quantum HD Wide . VA50 version of this protocol has added the keyword Wide to the protocol name. Collimation of 120 x 0.2mm RoutineSpiralAdultThoraxQuantumplus Quantum HD results with slice thickness down to 0.2mm and kernel sharpness up to 98 · All reconstructions will be a T3D, with no spectral results available. Image Impression Thorax 10.00 Bl60 Q3 ax Off arameter New Scan Parameter Settings Quantumplus Default 140 kVp Routine Quantumplus now defaulted to 140 kVp · This is due to · Improved spectral performance · Optimized energy thresholds You will now get increased dose savings in spectral imaging, at the same image quality. All routine Quantumplus protocols Brain protocols will remain at 120 kVp. arameter All Quantum HD protocols will remain at 120 kVp due to reduced iodine contrast in T3D images. Contr kV Eff. mAs Auto (Non-Contrast) (32 cm) 2.90 (15.7 cm) 6.56 Brain protocols will remain at 120 kVp. All Quantum HD protocols will your attention gemain at 120 kVp due to reduced iodine contrast in T3D image Engineering success. Pioneering healthcare. Thank you for Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS
- ct
- vb10
- update
- upgrade
- general
- improvement
- naeotom
- neotom
- alpha
- aphla