
Multitom Rax Turnover Workbook
Multitom Rax Turnover Workbook
Turnover Workbook | Multitom Rax Multitom Rax Turnover Workbook SIEMENS Heolthineers Education & Workforce Solutions SIEMENS Your potential is calling. Healthineers Turnover Workbook | Multitom Rax Welcome A Message from Nanci Wozniak Welcome to your training experience with Education & Workforce Solutions. I want to personally thank you for choosing Siemens Healthineers. We are honored to have you as our partner and hope you will enjoy this course. Our teams strive to ensure your priorities and needs are met. We sincerely appreciate your hard work around what really matters - the human side of health care. You are our heroes. Thank you for being part of the Siemens Healthineers family and we look forward to our partnership with you. Nanci Wozniak Vice President, Education & Workforce Solutions CX SV USA – Customer Service Organization Siemens Healthineers Clinical Training and Continuing Education Contact Information Customer Care Center - Clinical Application Support: Call 1-800-888-7436 PEPconnect https://pep.siemens-info.com/en-us 2 Turnover Workbook | Multitom Rax Contact Information Summary Welcome to Siemens Healthineers Siemens Training Centers Siemens Healthineers is dedicated to helping you get Siemens Clinical Education the most out of your investment throughout the Training Center – TDC2 entire product life cycle and beyond. Our goal is to 110 Mac Alyson Court enable you to take technology further, profitability Cary, NC 27511 higher, and patient care to the next level. Find the information, resources, and tools you need to get the most out of your recent investment and stay up- to-date. Visit https://www.siemens-healthineers.com. Clinical Training and Continuing Education Customer Care Center - Clinical Application Support: Call 1-800-888-7436 • Troubleshooting assistance • Immediate assistance for software applications and workflow issues • Please provide the Functional Location Number when calling for assistance. Clinical Education Offerings: Call 1-888-221-8010 (follow the prompts) • Classroom Training (Offerings, Registration & Scheduling) • Educational Symposia • On-site Training • Printed Self-studies • Virtual Education (Offerings & Registration) • Workshops & Fellowships Visit https://www.siemens-healthineers.com/en-us/ education/personalized-education-by-solution for more information regarding the current Siemens Healthineers Clinical Training and Continuing Education portfolio. 3 Turnover Workbook | Multitom Rax Contents Welcome .................................................................................................................................................................................2 Contact Information Summary ........................................................................................................................................3 Contents .................................................................................................................................................................................4 Course Description............................................................................................................................................................... 5 Agenda ....................................................................................................................................................................................6 1. System Introduction & Startup..................................................................................................................................... 7 2. System training continued........................................................................................................................................... 15 3. Review & Ortho* Training.............................................................................................................................................29 4. Patient Exams & Review ..............................................................................................................................................30 5. Customer Care Center & Review ................................................................................................................................ 31 4 Turnover Workbook | Multitom Rax Course Description Course Overview: This training guide will enable the end user to affectively operate the Multitom Rax at its optimal level. Proper use of system functions and features will empower operators with precise workflow, quick patient through put and user satisfaction. Upon completion of this course, you will be able to: • Perform start-up and shutdown procedures • Identify the key hardware features of the Multitom Rax system • Utilize the FLUOROSPOT Compact imaging system • Navigate postprocessing functions to optimize image impression • Troubleshoot common issues 5 Turnover Workbook | Multitom Rax Agenda Day One Introduction to basic system workflow Storing stand positions Protocol customizations Day Two Day one review Wireless remote control Fluorospot Compact Tube Stand Touch User Interface Perform patient exams Day Three Perform patient exams Review system Q&A Ortho package and options (if applicable) Image quality review Day Four Perform patient exams Review system Day Five Perform patient exams Q&A Intro to Customer Care Center 6 Turnover Workbook | Multitom Rax 1. System Introduction & Startup 1.1 Objectives Notes By the end of this section, the technologist will be able to: • Turn the System On/Off • Utilize the Tube/Detector Stand buttons • Identify the Emergency Stop Buttons • Describe tabletop functions • Navigate basics of the PEX Editor • Store Stand Positions 1.2 System On/Off The system is turned On/Off by selecting the corresponding button on the Remote Control Console (RCC) or at the Exposure On/Off console, if no RCC. A daily reboot of the system is recommended. SIEMENS WARNING! 7 Turnover Workbook | Multitom Rax 1.3 Tube Stand Movement Buttons Notes (1) (5) (2) (6) (3) (7) (4) # 20 cm H ACSS # 20 cm 3 (1) Rotation Around Vertical Axis (2) Longitudinal Tube Movement (3) Vertical Tube Movement (4) Detector to Tube Centering/RAXalign (5) Rotation Around Horizontal Axis (6) Transverse Tube Movement (7) Horizontal Float Only (8) Three Directional Tube Float 1.4 Detector Stand Movement Buttons • Rotation Around Horizontal Axis (RHA) • Rotation Around Transverse Axis (RTA) 8 Turnover Workbook | Multitom Rax Notes • Manual Vertical Movements • Tube to Detector Centering/RAXalign • Motorized Vertical Movements T 1.5 Emergency Stop Buttons STOP • Table Side Locations • Wall Locations • Remote Control Console • When pressed all motor driven system movements are interrupted. 9 Turnover Workbook | Multitom Rax 1.6 Table Top Notes • The tabletop is 3 meters long, and weighs approximately 58 lbs. • The Max patient table weight is 529 lbs. • The tabletop can be removed if not required for the examination. • Hand grips can be attached to the table for patient safety. 1.7 PEX Editor Opening the PEX Editor 1.On the Patient Task Card > Settings Subtask Card, select this icon: 2.The Logon Screen will appear Programs and Exams Editor 3.Select the radio button next to Siemens. 4.Enter the password the Applications Specialist provided and select OK. Programs and Exams Editor Login Viewing only @ Customer O SIEMENS Password ..... OK OK 10 Turnover Workbook | Multitom Rax Exam Tab Notes • The PEX Editor opens to the Exam subtask card. Exam Organ Program Fluoro Program Param. Module Configuration OGP View Examination View 9_Peri_Template (d) ABDOMEN 3 VIEWS_S(d) C Abdomen, left side pos. (d) ABDOMEN FLAT & UPRIGHT_S(d) .... C C-spine lat (d) C Femural neck axial (d) C Hip (d) sert OGP T ABDOMEN SUPINE (d) X ABDOMEN SUPINE (d) C Hip, with grid (d) T ABDOMEN (8-13cm) (d) .... C Humerus lat (d) T ABDOMEN (14-19cm) (d) C Patella tangential (d) T ABDOMEN (20-25cm) (d) .... C Pelvis (d) L XTL ABDOMEN DECUB (d) .... C Pelvis, with grid (d) CR (d) C Portable lung (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) .... C Portable lung, with grid (d) ABDOMEN-ACUTE INCL PA CHEST_S( C Shoulder (d) Remove OGP ABDOMEN-DECUBITUS_S(d) .... C Shoulder axial (d) ABDOMEN-LATERAL ONLY_S(d) C Zygomatic arch (d) ACROMIOCLAVICULAR JOINTS BIL_S( Group by Name Body Part Acq. type Sort by O Name Body Part Acq. type Exam Parameters Default Exams OGP Parameters ExamName ABDOMEN KUB_S Name for RIS ABDOMEN KUB_S DICOM Modality Add to favorites Filming Layout Network Node 1 Default Network Node Exam level GP leve Network Node 2 Fluoro Network Node 3 Rad Camera Default camera Auto Scale O Auto Scale Autosending Never for this exam Automatically switch to next OGP after acquisition Store as new Store Close Modifying Exam Names Exam Organ Program Fluoro Program Param . Module Configuration OGP View Examination View 9_Peri_Template (dl) ARDOMFN 3 VIFWS_S(d) C Abdomen. left side pos. (d) ABDOMEN FLAT & UPRIGHT_S(d) C C-spine lat (d) C Femural neck axial (d) C Hip (d) Insert OGP T ABDOMEN SUPINE (d) X ABDOMEN SUPINE (d) C Hip, with grid (d) T ABDOMEN (8-13cm) (d) .... C Humerus lat (d) T ABDOMEN (14-19cm) (d) C Patella tangential (d) T ABDOMEN (20-25cm) (d) C Pelvis (d) L XTL ABDOMEN DECUB (d) C Pelvis, with grid (d) C Portable lung (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) C Portable lung, with grid (d) C Shoulder (d) Remove OGP ABDOMEN-ACUTE INCL PA CHEST_S( ABDOMEN-DECUBITUS_S(d) .... C Shoulder axial (d) ABDOMEN-LATERAL ONLY_S(d) C Zygomatic arch (d) ACROMIOCLAVICULAR JOINTS BIL_S( Group by O Name Body Part Acq. type Sort by O Name Body Part Acq. type Exam Parameters Default Exams OGP Parameters ExamName ABDOMEN KUB S me for RIS ABDOMEN KUB S DICOM Modality Add to favorites Filming Layout Network Node 1 Default Network Node Exam level OGP level Nelwurk Nude 2 Fluuru Network Node 3 Camera Default camera . Alle scale Auto Scale Autnsending Never for this exam % Automatically switch to next OGP after acquisition Store as new Store Delete Close • The Examination View is located on the right side of the screen in the Exam tab. • This is where the names can be created or modified to match the RIS Exam Names (a copy of the RIS Exam Names should be supplied by the site). • Left Click on an Exam name that is like the name in the RIS worklist. • Populate the Name for RIS field, with the name from the RIS list, then copy and paste this name into the Examination View field (Control C to copy and Control V to paste). • Use Store if the name was modified and Store as New if a new name is created. 11 Turnover Workbook | Multitom Rax Modifying or Creating Organ Programs Notes 1.The OGP View is on the left side of the screen in the Exam Tab. This is where Organ Programs that need to be modified can be selected. 2.When creating or modifying Organ Programs, be mindful to pick the correct prefix. • C = Cassette Exposure (CR or Film) • T = Table Exposure (Detector under the table) • W = Wall stand Exposure (Wall position) • V = Free Exposure (Detector Stand) • X = Free Exposure* (Wireless Detector) • Fluoro = Fluoroscopy Mode • DSA = Subtracted Imaging/Roadmap* • OW/OT = Ortho Imaging* (In table mode or wall mode) • L = Cross table Exposure 3.Double left click on the Organ Program to be modified. 4.The Organ Program subtask card will open. 5.In the Program Name field, remove the (d) and enter the new or modified name. 6.Adjust any Exposure Parameters/Settings and select Store for modifying or Store as New if a new Organ Program is created. * Option Exam Organ Program Fluoro Program Param . Module Configuration Body Part Examined ABDOMEN Alternative Acquisition Programs Program Name T ABDOMEN SUPINE (d) X ABDOMEN SUPINE (d) X ABDOMEN DECUB (d) W ABDOMEN UPRIGH. Acquisition Mode DR RAD Acquisition Type Table X - Ray Parameters Image Processing Parameters Presettings Mark Image Auto-cropping Standard Set Black Fluoro Program Set CP_RAD_Po ... PT Position Not defined Defined size as cropped Laterality Not Defined MField Amplification 2.0 v Auto Enhanced MField View position Not Defined O 1 pt Gradation Parameters Anatomically Correct View 1 pt with ext. exp. 13 Spine/Abdomen Flip No change ... 3 pt Invert (Image) )3 pt with AEC Spatial Frequency Parameters KV 81 Rotate 90 180 @ 270 MAS Abdomen Label ms EXI Value 88 Exp. Correction 0 EP default Dose 2.5 Sensitivity 400 Vindowing Stand Parameters Tube Load 80 % Width Factor Auto TOD not defined cm Focus Center Shift Grid 115v Filter Type 0.0 Cu mm Window Center 2000 cm Grid rotation Collimator 16.93 × 16.93 inches Window Width 2500 Stand Position Table position Top Alignment |SID Tracking Tracking Table Anatomic order number 0 Store Store as new Print DEICHE previous next Close 12 Turnover Workbook | Multitom Rax Adding an OGP View to Examination View Notes Exam Organ Program Fluoro Program Param. Module Configuration OGP View Examination View T ABDOMEN (20-25cm) (d) 0_Pex Database_OCT2015_G1_ROW(! T ABDOMEN (8-13cm) (d) 0_RAD_Daily_Check(d) T ARDOMEN RARIUM AP (r) n_Siemens CSF Test Programs(d) ..... T ABDOMEN BARIUM PA (d) Insert Ocr 1_Position_Setup T ABDOMEN IODINE (d) ABDOMEN 3 VIEWS_S(d) T ABDOMEN LATERAL (d) ABDOMEN FLAT & UPRIGHT_S(d) T ABDOMEN OBLIQUE (U) T ABDOMEN PEDS BARIUM AP (d) T ABDOMEN SUPINE (d) ..... T ABDOMEN PEDS IODINE (d) X ABDOMEN SUPINE (d) T ABDOMEN SUPINE (d) T ABDOMEN (8-13cm) (d) ..... T ABDOMEN UPRIGHT (d) T ABDOMEN (14-19cm) (d) ..... I AC JOINIS (d) ..... T ANKLE 0-0yrs (d) Remove OGP I ABDOMEN (2U-25cm) (a) L XTL ADDOMEN DECUD (d) ..... T ANKLE 4-12yrs (c) CR (c) T ANKLE AP (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) * ..... Group by O Name Body Part Acq. type Sort by O Name Body Part Acq. type Exam Parameters Default Exams OGP Parame ExamName ABDOMEN KUB_S Name for RIS ABDOMEN KUB_S DICOM Modality Add to favorites Filming Layout Network Node 1 Default Network Node Exam level OGP level Network Node 2 Fluoro Network Node 3 Camera Default camera Auto Scale Auto Scale Autosending Never for this cxam Automatically switch to next OGP after acquisition Store as new Store Delete Close 1.Highlight the desired Examination View and highlight the OGP View to be added, select Insert OGP. To remove OGP Views, highlight the OGP View from the desired Examination View and select Remove OGP. 2.The order of the OGP Views can be adjusted, using the up/down arrows. 3.The check box for automatically switch to next OGP after acquisition allows the next view to populate automatically. Select Store to save this function per OGP View. Backup PEX Editor 1.After changes to the PEX Editor, a backup is recommended. 2.While in the PEX Editor, select the Configuration tab. 3.Select Backup/Export 4.Select the C or D drive and go to back up the PEX Editor to the local hard disc (each drive can hold ten backups). Exam Organ Program Fluoro Program Param Module Configuration Units fo Password Collimator Size inches Change Password Reset Customer Password Data Type Selection Siemens Default Database Export/Import inguage English Backup / Export Restore / import Merge Image Converter Flat detector Include RIS Names. Image intensifier Pex Versions Editor version: $.9.30. Database version: 60 Store Close 13 Turnover Workbook | Multitom Rax 1.8 Stand Positions Notes Each Organ Program will have a stand position assigned to it. The exact location of the position in the room will be configured in the PEX Editor. Each stand position may be used by multiple Organ Programs. Storing Stand Positions in the PEX Editor 1.Set up the system in the desired location in the room. 2.Select the Parameter Module tab in the PEX Editor. 3.In the Stand Position Section (top right), select the desired stand position from the Name field. Exam Organ Program Fluoro Program Param. Module configuration Body Part Examined Stand Position ABDOME Identifier s005 Store Name Table position New Collimator settings Ignore for auto cropping Position: Assigned Identificr Store Position store Parameters Name Min. EXI Delete Activate New O Max. EXI O Target EXI Spatial Frequency Parameters Delete Store New Gradation Parameters Identifier Identifier Name Name Diamond View ID UU Shape Diamond View Name Off Contrast 0.1 Noise Reduction Center Edge Filter: Kernel Offsel -2048 Edge Filter: Gain Harmonization: Kernel Delete C Store New Harmonization: Gain Trajectory Import Delete Store New CLOSE 4.Select Store Position (confirm override of previous stand position if asked) Assigning Stand Positions to Organ Programs 1.In the Exam tab double left click on the Organ Program to be modified. 2.In the Stand Parameters section (bottom right), select the desired Stand Position from the drop down and select Store. 14 Turnover Workbook | Multitom Rax 2. System training continued 2.1 Objectives Notes By the end of this section, technologists will be able to: • Review and use the wireless Remote Control • Utilize the Fluoro Spot Compact and all corresponding tabs • Utilize the Tube Stand and TUI • Navigate the Remote Control Console* and TUI • Prepare room for patient exams 2.2 Room Review 2.3 Wireless Remote Control • The wireless remote has an approximate range of five meters around the receiver mounted to the stand. • Charging time is approximately two hours. • Operating time with a full battery is approximately twelve hours. Display area ---- Operation area # Selection area --- - p • Dead-man switch must be pressed to facilitate system movements. Dead-man switch *Option 15 Turnover Workbook | Multitom Rax Notes • Remote RHA Buttons • Remote RVA Buttons • Remote Transverse Adjustments • Remote Longitudinal Adjustments • Remote Move to OGP Position • Remote Vertical Adjustments • Remote Detector Center Tracking enable/disable • Remote SID Tracking enable/disable • Remote Activate Park Position P • Remote Charging Station 16 Turnover Workbook | Multitom Rax 2.4 Fluorospot Compact (FLC) Training Notes Attaching a detector 1.The MAX Detector Overview page must be open on the FLC. 2. 3.Hold the detector with the LEDs facing the infrared sensor on the upper right corner of the Fluorospot Compact. SIEMENS 4.All of the LEDs on the detector will start to blink orange, then green. 5.When the LEDs stop blinking, the detector can be taken away. 17 Turnover Workbook | Multitom Rax Patient Tab Notes • Pre-Registered and Examined Patient tabs • Patient subtask card Patient Settings Service + == RIS RIS • Settings subtask card Patient Settings Service ? EXI • Service subtask card Patient Settings Service 18 Turnover Workbook | Multitom Rax Examination Tab Notes • Patient and resource Information SIEMENS, SIEMENS 11-11-1999 Patient uGym2 0 0.00 O *T ABDOMEN (8-13cm) T ABDOMEN (14-19cm) T ABDOMEN (20-25cm) T ABDOMEN (26-31cm) Examination Fluoro Rad 16.6 “ x 16.6 8 41.6 " Post Current Target none • Fluoro* subtask card Examination Fluoro Rad Postprocessing 7.0 s O CP_Pediatric Series DSA p/s 3 2 KV 0 KV 73 mA 0.0 mAs Documentation Ims 0.0 ms min 000.0 Dose 3.48 0.0 mm Cu 0.3 mm Cu 0.0 30 p/s Focus mGy/min % < 2 Gy mGy 1.1 *Only available with Fluoro option • Rad subtask card Fluoro Rad 43.0 cm x 43.0 cm 0 cm Current Target none @ 115 cm KV 70 mAs Dose 0.89 S 0.0 mm Cu 0.0 Focus % 80 19 Turnover Workbook | Multitom Rax Postprocessing Tab Notes • Process subtask card T ABDOMEN (26-31cm) Examination Process. |Graphics Rad 0-0 R R Postprocessing -O'- • Graphics subtask card T ABDOMEN (26-31cm) Examination Process. Graphics Rad Postprocessing XYZ • Rad subtask card T ABDOMEN (25-31cm) Examination Process. Graphics Rad Auto-cropping Set black Auto-window Amplification 0.5 V Auto Postprocessing as cropped 20 Turnover Workbook | Multitom Rax Notes • DSA subtask card* VOSA TABLE_PEDIATRIC_2fp - CR Examination Process. Graphics DSA Jopac % Postprocessing -O- • Image subtask card tation KV 0 KV 73 mA 0.0 mAs min 000.0 ms Image Tools • Tools subtask card itation KV 0 KV 70 mA 0.0 mAs 28 min 000.0 ms Image Tools REE REF 21 Turnover Workbook | Multitom Rax Notes • Documentation Tab • Select subtask card xamination Select Film Send Postprocessing Documentation KV KV 73 mA 0.0 ImAs • Send subtask card Select Film amination Send Target 1 Target 2 Target 3 ¥ Postprocessing Send Exam Protocol as: SC image DICOM Dose SR Override configured settings Documentation ? KV 0 KV 73 mA 0.0 MAS 22 Turnover Workbook | Multitom Rax 2.5 Tube Stand with MAX Touch User Interface Notes Generator Tab • Exposure Parameters • Home Button Tape Measure Tab • SID Measurement 8 • SOD Measurement 8 • Magnification display (SOD Mag = SID/SOD) Device Position Tab • Zero-degree detent On/Off • Tube rotation Horizontally/Vertically • Detector RHA/RTA • MAXalign* 50º • Combined angulation Setup Tab • Block Movement/block Radiation • CAREposition On/Off* • Stand Movement Speed *8> *Option 23 Turnover Workbook | Multitom Rax 2.6 Remote Control Console* (RCC) with TUI Notes Hardware Functions O STOP WARNING! THIS X-RAY UNIT MAY BE DANGEROUS TO PATIENT AND OPERATOR UNLESS SAFE EXPO- SURE FACTORS, OPERATING INSTRUCTIONS AND MAINTENANCE SCHEDULES ARE OBSERVED. T P • Collimation Adjustments # # # • Tube Angulation • Orbital Movements *option 24 Turnover Workbook | Multitom Rax Notes • Exposure with rotor • Room lights (If configured) • SID adjustments + 110|- • Room On/Off Ò • Emergency Stop STOP • Park P • Patient transfer • Slow/Fast OGP position ¥ Touch User Interface (TUI) • The TUI is split into three main sections: Fluoro Settings, Acquisition Settings, and the Image/Tools/Setup Subtask cards • Header Information is always displayed at the top • Footer Information is always displayed at the bottom 25 Turnover Workbook | Multitom Rax Fluoro Settings Notes 0 0.2 KV mm Cu 0.0 V 30 MA p/s 0:00 15 min p/s • Automatic Fluoro Program 1,2, or 3 • Automatic Fluoro Stop • Reset Fluoro Alarm • Store Fluoro Loop • Fluoro Pulse Rate Selection Acquisition Settings + 70 KV f/s • Exposure Parameters • Frame Rate Selection • Series On/Off • Restore Original Values (Home) • + Button (Show More Parameters) 26 Turnover Workbook | Multitom Rax Image subtask card Notes Image Tools Setup REF REF • Image navigation • Start/Stop Loop Replay • Last Image Hold (LIH) • Display Overview Tools subtask card Image Tools Setup 10. # A IN • Image Navigation • Mark/Unmark Image • Set L/R Label • Magnification • Lock Collimation • DSA Functions* *Option 27 Turnover Workbook | Multitom Rax Setup subtask card Notes Image Tools Setup R R A • Flip Horizontal/Vertical • Reverse Transverse/Longitudinal Movement • Block Movement/Block Radiation • DVD Recording (optional) • CAREposition* 2.7 Perform Patient Exams *Option 28 Turnover Workbook | Multitom Rax 3. Review & Ortho* Training 3.1 Objectives Notes By the end of this section, technologists will be able to: • Review the Ortho Package and options • Utilize room for patient exams 3.2 Review 3.3 Ortho Package Training* System Set Up • Tube/Detector Ortho Tab* • TOD 10.5 cm • Set Position one (Start Position) • Set Position two (End Position) Auto Composing • Manual Adjustments 3.4 Perform Patient Exams *Option 29 Turnover Workbook | Multitom Rax 4. Patient Exams & Review 4.1 Objectives Notes By the end of this section, technologists will be able to: • Utilize room for patient exams 4.2 Review 4.3 Perform Patient Exams 30 Turnover Workbook | Multitom Rax 5. Customer Care Center & Review 5.1 Objectives Notes By the end of this section, technologists will be able to: • Utilize room for patient exams • Review checklist 5.2 Customer Care Center • To contact the Customer Care Center dial 800-888-7436, then follow the prompts to route you to applications or technical support. 5.3 Review 5.4 Checklist 31 Workbook | Workbook Name Notes 32 Turnover Workbook | Multitom Rax On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country Local Contact Information and is subject to change without prior Siemens Medical Solutions USA, Inc. notice. Some/All of the features and 40 Liberty Blvd. products described herein may not be Malvern, PA 19355-9998 available in the United States. USA Telephone: +1-888-826-9702 Customer Care The information in this document Telephone: +1-800-888-7436 contains general technical descriptions https://www.siemens-healthineers.com/en-us of specifications and options as well as standard and optional features which do not always have to be present in Legal Manufacturer individual cases. Siemensstrasse 1 Forchheim, Germany 91301 Siemens reserves the right to modify the design, packaging, specifications Phone: +49 9131 84-4746 and options described herein without https://www.siemens-healthineers.com/radiography prior notice. Please contact your local Siemens sales representative for the most current information. Siemens Healthcare Headquarters Siemens Healthcare GmbH Healthcare Sector Note: Any technical data contained in Henkestr. 127 this document may vary within defined 91052 Erlangen tolerances. Original images always lose Germany a certain amount of detail when Phone: +49 9131 84-0 reproduced. https://www.siemens-healthineers.com Published by Siemens Healthcare GmbH · Printed in USA · 0000.2 · ©Siemens Healthcare GmbH, 2022 33
- Multitom Rax Turnover Workbook