Multitom RAX Performing True2scale acquisitions
Multitom RAX Performing True2scale acquisitions
Multitom RAX: Performing True2Scale acquisitions During the exam, the system will offer guidance through prompts on the workstation screen and the overhead tube face. 1. Open the patient and select a T2S organ program. 05-03-1967 uGy*m2 0.00 ient T25 U Spine M ap + lat T25 U Spine M ap T2S U Spine M lat T25 U Spine S ap + lat Exa Fluoro Rad 2. Define patient orientation in the box that populates. Upright: Patient Position Please define the patient position OK Cancel Supine: Patient Position Please define the patient position O OK Cancel 3. Remove grid, if prompted. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers 4. Position patient: Supine: Lying on the table, head at the head end, centered in the middle of the table. Upright: Standing in the L-stand in AP position only (stand positioned and locked in programmed floor location). Position the patient’s feet in the appropriate area of the positioning block. Remove the tabletop if necessary. 5. Press and hold the SmartMove button on the wireless remote control (along with the Dead Man Grip (DMG) on the back) to move the tube to the top of the scan range. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 2 of 5 6. To set the first position, select the tube on the wireless remote control. For supine exams, use the green longitudinal control to move the light field to the top of the anatomy to be imaged. For upright exams, use the blue vertical control. OR On the MaxTouch tube face, use individual directional control buttons. For supine exams, use only the green longitudinal button to move the light field to the top of the anatomy to be imaged. For upright exams, use only the blue vertical button. 7. On the wireless remote control press the SmartMove button once (without applying pressure to the touchpad on the back of the control) to set Position 1. OR On any available Touch User Interface (tube face or remote control console*), tap the round icon marked 1 to set Position 1. 1 8. Press and hold the SmartMove button on the Wireless remote control (along with the Dead Man Grip (DMG) on the back) to move the tube to the bottom of the scan range. 9. On the wireless remote control, select tube. For supine exams, use green longitudinal con- trol to move the light field to the bottom of the anatomy to be imaged. For upright exams, use blue vertical control. OR On the MaxTouch tube face, use individual movement control buttons. For supine exams, use only the green longitudinal button to move the light field to the bottom of the anatomy to be imaged. For upright exams, use only the blue vertical button. 10. On the Wireless remote control press the SmartMove button once (without applying pressure to the touchpad on the back of the control) to set Position 2. OR On any available Touch User Interface (tube face or remote control console*), tap the round icon marked 2 to set Position 2. 11. SmartMove to the start of the scan. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 3 of 5 12. If preferred, collimate side to side. Collimation size will be valid for the AP scan only. Collimation will open for the lateral scan. 13. Using any exposure button (on the console, hand switch*, back of Multifunction Joystick*, or fluoroscopy pedal*), hold exposure down throughout the entire duration of the scan (sin- gle direction for AP or LAT only, both directions for AP+LAT). Acquired images will automati- cally send to the View&GO workstation for automatic reconstruction. 14. If a scan repeat is necessary, SmartMove again to position at the start of the scan using previ- ously stored positions. *Items marked with an asterisk are options. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 4 of 5 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collec- tively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not neces- sarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Healthcare Sector Henkestr. 127 40 Liberty Blvd. Magnetic Resonance 91052 Erlangen Malvern, PA 19355-9998 USA Henkestr. 127 Germany Telephone: +1-888-826-9702 DE-91052 Erlangen Phone: +49 9131 84-0 Customer Care Telephone: Germany https://www.siemens-healthineers.com +1-800-888-7436 Telephone: +49 9191 18-0 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 5 of 5
- true2scale
- rax