Multitom RAX Performing Real 3D upright acquisitions
Multitom RAX Performing Real 3D upright acquisitions
Multitom RAX: Performing Real 3D upright acquisitions During the exam, the system will offer guidance through prompts on the workstation screen and the overhead tube face. 1. Open the patient exam and select the desired 3D desired organ program. Remove the tabletop if necessary. Place the stand in a dedicated location on the floor. 3D Examination, Knee 040822_150334 O uGy*m2 0 10.00 30 T Knee 2. Insert the Horizontal grid if prompted. 3. Position the patient standing in the L stand, facing forward and using the correct positioning accessories and appropriate location on the stand base. For lumbar exams, place each foot on a dotted line. For knee exams, place the foot of the leg of interest on the center of the dotted line with the heel touching the solid line in the back. For foot/ankle exams, place the appropriate foot in the center of the field on the solid line. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers 4. Press and hold the SmartMove button on the wireless remote control (along with the Dead Man Grip (DMG) ) on the back to move the system into the start position. Monitor for any collisions. 5. Ensure the anatomy is centered laterally. If necessary, adjust the tube height using the remote control by selecting the tube button and using the blue buttons to raise or lower the tube. For other adjustments, move the patient. 6. Press and hold the SmartMove button to start the 3D test run. Continue to monitor for collisions. 7. Ensure the anatomy is centered. Adjust the patient if necessary. Press the SmartMove button again to complete the test run. Hold until prompted to disengage. Continue to monitor for collisions. 8. Press and hold the SmartMove button to complete the 3D test run. Continue to monitor for collisions. 9. In the control room, use any exposure button (on the console, hand switch*, back of Multi- function Joystick*, or fluoroscopy pedal*) to start acquisition by pressing the button and holding it throughout the entire duration of the scan. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 2 of 4 10. Once the scan is complete, use either the SmartMove button to move the system into the transfer position or the lower left purple button to move to the start position to repeat the scan. 11. Acquired images will be automatically sent to the syngo.via View&GO Workstation. *Items marked with an asterisk are options. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collec- tively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not neces- sarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Healthcare Sector Henkestr. 127 40 Liberty Blvd. Forchheim, Germany 91301 91052 Erlangen, Germany Malvern, PA, USA 19355-9998 Phone: +49 9131 84-4746 Phone: +49 9131 84-0 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography siemens-healthineers.com siemens-healthineers .com/en-us Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 4 of 4
- rax