Multitom RAX: Performing Real 3D table acquisitions During the exam, the system will offer guidance through prompts on the workstation screen and the overhead tube face. 1. Open the patient exam and select the desired 3D lower extremity organ program. 3D Examination, Knee 040822_150334 uGy*m2 0 0 0.00 3D T Knee 2. Define the patient’s position and laterality. Attach the tabletop extension to the table. Position the patient on the table with their head closest to the table base end. Patient Position / View Position Please define the patient position Head First Feet First Please define the image laterality Left Right None OK Cancel 3. Insert the Horizontal grid if prompted. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 4. Press and hold the SmartMove button on the wireless remote control (along with the Dead Man Grip (DMG) on the back to move the system into the start position. The table will be high and the tube and detector will be in place for the scan. 5. Position the patient with the area of interest centered in the light field. For knees, center the knee of interest in the light field, keeping the knees close together. For foot/ankle, center foot/ankle of interest in the light field. Position the other leg out of the FoV. 6. Press and hold the SmartMove button to start the test run. Monitor for any collisions. 7. Ensure anatomy is centered laterally. If necessary, adjust the table height using the remote control by selecting the table button and using the blue buttons to raise or lower the table. For other adjustments, move the patient. 8. Press and hold the SmartMove button again to complete the test run. Hold until prompted to disengage. Continue to monitor for collisions. 9. In the control room, use any exposure button (on the console, hand switch*, back of multi- function joystick*, or fluoroscopy pedal*) to start acquisition by pressing the button and holding it throughout the entire duration of the scan. 10. Once the scan is complete, use either the SmartMove button to move the system into the transfer position or the lower left purple button to move to the start position to repeat the scan. 11. Acquired images will be automatically sent to the syngo.via View&GO Workstation. *Items marked with an asterisk are options. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 2 of 3 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collec- tively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not neces- sarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemensstrasse 1 Healthcare Sector Henkestr. 127 40 Liberty Blvd. Forchheim, Germany 91301 91052 Erlangen, Germany Malvern, PA, USA 19355-9998 Phone: +49 9131 84-4746 Phone: +49 9131 84-0 Telephone: +1-888-826-9702 siemens-healthineers .com/radiography siemens-healthineers.com siemens-healthineers .com/en-us Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2023 | HOOD05162003356945 Healthineers Page 3 of 3

  • rax