
syngo MR XA51 What's New List - USA
The What's new list provides you an overview of features and options coming with the software XA51.
Target group: All users.
MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit syngo MR XA51A What’s New 7 siemens-healthineers.us/ magnetic-resonance-imaging Healthingers SIEMENS althMENS (O) MAGNETOM Sola MAGNETOM Altea MAGNETOM Sola Fit Cardiovascular Billion SIEMENS Healthineers E A Dear MAGNETOM user, We are pleased to announce the arrival of our latest MRI scanner software, syngo MR XA51A. syngo MR XA51A provides comprehensive improvements to your existing scanner functionality and access to exciting new features. Scanners qualified for this update include the following 1.5T systems: • MAGNETOM Sola • MAGNETOM Altea • MAGNETOM Sola Fit For MAGNETOM Sola Fit, please also refer to the syngo MR XA31A delta list. Learn more about syngo MR XA51A in this informative packet and discover how it can improve your daily routine. Sincerely yours, Your Siemens Healthineers MR team 2 Contents Click each section below to learn more 1. New sequences, protocols and applications 1.1 BioMatrix Beat Sensor 1.2 Deep Resolve Boost 1.3 Open Recon 1.4 BLADE Diffusion with SMS functionality 1.5 myExam Angio Advanced Assist 1.6 myExam 3D Camera 1.7 myExam Brain Autopilot and myExam Knee Autopilot 2. Improvements to sequences, protocols and applications 2.1 Deep Resolve Gain 2.2 Deep Resolve Sharp 2.3 Breast Biopsy improvements (detection of fiducial markers) 2.4 Motion Correction for TSE with more than a single average 2.5 GSP: Toolbar pinning 2.6 GSP: Center line for scan planning 2.7 Transition of Dot Engines to myExam Companion 2.8 Improvements to Simultaneous Multi-Slice TSE imaging 2.9 Faster image reconstruction in Simultaneous Multi-Slice imaging 2.10 Improved RESOLVE diffusion imaging in the breast 2.11 Improvements for radial planning 2.12 Improvements of SAR Assistant 2.13 Improvement of graphics handling – DICOM interoperative mod 2.14 Multi Environment Profiles 3 syngo MR XA platform – XA51A E A 1. New sequences, protocols, and applications 1.1 BioMatrix Beat Sensor Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature for MAGNETOM Sola and MAGNETOM Sola Fit; Optional feature for MAGNETOM Altea Pre-requisites: BioMatrix Body 12 Coil or BioMatrix Body 18 Coil The BioMatrix Beat Sensor is a Siemens Healthineers Highlights and benefits: unique breakthrough technology which enables a • complete cardiac MRI exam without ECG leads! Beat Eliminates the need to place electrodes on the Sensor uses the heart’s own beating motion as the patient and thus speeds up the workflow for triggering source. This is unlike ECG which only indirectly CMR exams • measures the onset of cardiac motion by detecting the Saves time that would be spent shaving chest hair, electrical activity of the heart. using cleaning gel, and placing electrodes on patients • Improves the patient experience, especially for patients who have sensitive skin (e.g. allergic to cleaning gel) and/or feel uncomfortable with ECG lead placement • Saves on supplies and reduces plastic waste BioMatrix Beat Sensor triggering vs ECG ECG I 57 min AR4 1047 ms Beat Sensor Cardiac @ 57 min RR.4 1052 mS CINE Segmented with ECG CINE Segmented with Beat Sensor 1aaaa3624 4 syngo MR XA platform – XA51A E A 1.2 Deep Resolve Boost Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Optional feature Pre-requisites: High-end MaRS (Reconstruction System) Note: TSE is supported with the exception of BLADE TSE and Dixon Deep Resolve Boost takes Deep Learning Reconstruction with Simultaneous Multi-Slice (SMS) TSE, rendering this to the next level. It enables previously inaccessible the industry first k-space-to-image-space Deep Learning parallel imaging acceleration. This is made possible by Reconstruction combinable with SMS TSE. our first raw-data-to-image Deep Learning reconstruction. The neural network behind Deep Resolve Boost enables Highlights and benefits: effective denoising that improves the visual signal- • to-noise ratio of the images. The Deep Learning Deep Learning Reconstruction with effective denoising • reconstruction used in Deep Resolve Boost achieves Three user selectable levels for the denoising strength • a stronger denoising than Deep Resolve Gain and Utilizes parallel imaging factors previously inaccessible the denoising strength can be adapted by choosing in MR imaging • from three levels. With this, Deep Resolve Boost will Significantly cuts down scan times for TSE imaging significantly cut scan times in clinical routine areas such sequences • as neuro, spine, and MSK while not compromising on Compatible with SMS TSE, a Siemens Healthineers image quality. Deep Resolve Boost can be combined exclusive feature C 50% faster 1aaaa3996 Example of T2 TSE imaging in the brain. Left: PAT 2, conventional reconstruction (GRAPPA); right: PAT 4 with Deep Resolve Boost and Sharp. PD TSE fs PD TSE fs PD TSE fs T1 TSE PAT3 SMS2 DRB DRS PAT3 SMS2 DRB DRS PAT3 SMS2 DRB DRS PAT3 SMS2 DRB DRS 0.3 x 0.3 x 3 mm³ 0.3 x 0.3 x 3 mm³ 0.3 x 0.3 x 3 mm³ 0.3 x 0.3 x 3 mm³ TA: 1:00 min TA: 43 s TA: 50 s TA: 36 s Total scan time: 3:09 min 1aaaa3995 Deep Resolve Boost supports SMS TSE, a Siemens Healthineers exclusive feature. This enables ultra-fast high-resolution knee imaging in 3:09 minutes with 6-fold acceleration for each contrast (PAT3 SMS2). 5 syngo MR XA platform – XA51A E A 1.3 Open Recon Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: SubtleMR license, High-end MaRS Open Recon is a developer-friendly open digital interface Highlights and benefits: for co-creation and knowledge exchange with partners. • SubtleMR is our first partner on the Open Recon Open platform design between Siemens Healthineers environment. The partner application will run within a and partners • container directly on the MaRS and is seamlessly 3 rd party image reconstruction techniques and machine integrated in the imaging reconstruction chain. It will learning directly at the scanner • manifest as an additional tab on the “Inline” card and Inline reconstruction can facilitate clinical evaluation • provide convenient access to options supported by Open Convenient access via new tab on the “Inline” card Recon. Results are displayed in the user interface and will appear in the DICOM data base. The Open Recon Framework only allows FDA cleared 3rd party algorithms to be imported for clinical use. General 8 41 sec | Auto @ 2 0.9x0.9x4.0 mm3 ֏ 1.00 Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Ference Voice Commands Execution Liver Subtraction MIP Soft Tissue Composing Maplt Open Recon Image Management Algorithm SubtleMR V1 Auto Load Copy References Preset super-resolution Free Text ... OK Cancel The Open Recon tab can be found under “Inline”. 6 syngo MR XA platform – XA51A E A 1.4 BLADE Diffusion with SMS functionality Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature (BLADE TGSE) Optional feature (BLADE Diffusion and SMS option) Pre-requisites: None BLADE Diffusion is a new member of the BLADE family With the additional option of the Simultaneous Multi- based on the TGSE sequence. It utilizes a TSE-based Slice (SMS) license (either individually or by selecting sequence design that enables an EPI readout to collect Turbo Suite Excelerate) you can use SMS to reduce the multiple echoes around the main spin echo. In its basic total scan time of the BLADE diffusion. SMS BLADE version, it will become available as standard with the Diffusion is a Siemens Healthineers exclusive feature. same functionality as the already available BLADE TSE, meaning EPI factor = 1. Highlights and benefits: By adding the BLADE Diffusion license, BLADE leverages • New non-EPI based diffusion functionality based on the advantage of the TGSE sequence design. Diffusion a BLADE TGSE sequence weighting is now available, allowing EPI factors > 1 so • No geometric distortions in challenging areas with that a BLADE-based non-EPI diffusion sequence becomes large susceptibility changes available. By performing diffusion imaging with a • SMS support for BLADE diffusion is a Siemens non-EPI sequence, geometric distortions are eliminated Healthineers exclusive feature in areas with large susceptibility changes such as the sinuses and the inner auditory canal. BLADE diffusion is recommended in situations where RESOLVE does not minimize geometric distortions sufficiently. 7 syngo MR XA platform – XA51A E A 1.5 myExam Angio Advanced Assist Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Optional feature Pre-requisites: myExam Angio Assist myExam Angio Advanced Assist is a semi-automated in the GSP. After planning is complete, the angio workflow for peripheral MR angiography examinations pre-contrast data-acquisition is executed for all planned with step-by-step guidance throughout the exam. This stations. workflow support feature offers clear planning for With the care bolus step the arrival of the contrast agent all multi-station angiography exams by enabling the is manually or automatically detected. Once the contrast planning in the Graphical Slice Positioning (GSP) user agent is detected, the angio post-contrast measurement interface for all stations in one common planning step. is performed in accordance with the pre-contrast This new Assist workflow uses test bolus and care measurement. Alternatively, the test bolus workflow can bolus-functionality to optionally track the bolus arrival be used. Finally, an optional dynamic CE MRA (TWIST) in the vessels. measurement can be performed myExam Angio Advanced Assist provides workflow support for peripheral MR angiography exams. After Highlights and benefits: performing an overview scan, the relevant peripheral • Automation and guidance for robust peripheral vessels and the aorta are localized. Then planning of the MRA exams actual angiography measurement is performed by using • Easy planning with coverage boxes, overlap clearly the Angio Advanced Planning Add-in, which enables visible users to plan all stations (abdomen, legs, feet) together • Individual parametrization Angio Assist Advanced Angio Advanced Patien ... Care Bolus Feet first - Position 20cm / 7in above feet FastView 00:35 Whole Body FastView Vessel Scout yes O Abdomen O Abdomen vessel scout 02:19 El Generic Views localizer_aorta 00:31 + Generic Views angio_f13d_cor_pre 00-39 Angio Advanced Planning Check pre images, prepare injector Legs Legs Care Bolus 01:21 Care Bolus angio_f13d_cor_post 00:39 1 TWIST feet yes Basic Decision Feet TWIST feet Feet yes angio_twist_cor iso feet 02:03 Feet Generic Views 8 syngo MR XA platform – XA51A E A 1.6 myExam 3D Camera Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Optional feature Pre-requisites: None Restrictions: • Pediatric patients are not supported. • Minimum distance between camera and patient table is 120 cm. Check the planning guide for detailed site requirements of myExam 3D Camera installation. The myExam 3D Camera automates patient positioning Highlights and benefits: and makes it more efficient, accurate and reproducible. • The AutoPositioning feature captures the patient’s shape AutoPositioning and position on the table in three dimensions. The Using infrared measurements, the myExam 3D Camera myExam 3D Camera extends the automatic positioning recognizes body contours and the position capabilities of BioMatrix Select&GO by additional body of the different body parts, e.g., the position of elbow, regions and coils. In addition, AutoRegistration is wrist, or hand. The AutoPositioning integrates these designed to help streamline and safeguard accurate measurements with the data from the Select&GO touch patient registration based on height and weight. display. The AI trained algorithm of the myExam3D Camera automatically detects body landmarks and positions the relevant body parts in the isocenter of the MRI scanner without the use of the table ruler or the positioning laser. This can make positioning up to 48%1 faster compared to a manual workflow without the help of the camera – allowing for accurate and consistent positioning – even with flexible Contour coils. myExam 3D Camera feature supports the following patient orientations: • Supine • Prone • Head first • Feet first • AutoRegistration2 AutoRegistration will autofill the weight, height and myExam 3D Camera orientation fields in the patient registration screen to assist with accurate patient registration. 1 AutoPositioning accuracy of 48%: Data on file. 2 AutoRegistration with detection of patient height, weight and orientation is still under development and not commercially available yet. It is not for sale in the U.S. Its future availability cannot be guaranteed. 9 syngo MR XA platform – XA51A E A 1.7 myExam Brain Autopilot and myExam Knee Autopilot Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None myExam Autopilot uses AI and automation to remove and simplify burdensome, routine tasks. myExam Autopilot Knee and myExam Autopilot Brain provide automation such as AutoPosition, AutoAlign, AutoCoverage, Inline MPRs, and the flexibility of customization for site specific standards of care. Predefined protocols enable you to scan with minimal manual interactions. You can switch to myExam Assist at any time to further personalize scan settings on the fly. Highlights and benefits: • Automates exams for novice users • Enables high quality scans with just a simple click 000000000 ...... myExam Knee Autopilot user interface. 10 syngo MR XA platform – XA51A E A 2. Improvements to sequences, protocols and applications 2.1 Deep Resolve Gain Available for: MAGNETOM Sola, MAGNETOM Altea and MAGNETOM Sola Fit Category: Optional feature Pre-requisites: None Note: TSE is supported with the exception of BLADE TSE Deep Resolve Gain is our solution for targeted denoising, this can be accomplished: Deep Resolve Gain can addressing local noise variations. Image noise usually is be used to mitigate noise introduced by reducing the not uniformly distributed in MR images. This is due to number of averages in the acquisition, or it can be coil array geometries, as well as acceleration techniques used to reduce image noise introduced by increasing such as parallel imaging. These local variations can’t be acceleration factors such as PAT. addressed by standard image filters. Deep Resolve Gain uses individual noise maps in the reconstruction process New benefits: to reduce noise where it is most needed in the image. • Deep Resolve Gain now supports TSE Dixon and Deep Resolve Gain can be used for the reduction of conventional Spin Echo image acquisition times. There are mainly two ways • Deep Resolve Gain is now compatible with SMS TSE 2.2 Deep Resolve Sharp Available for: MAGNETOM Sola, MAGNETOM Altea and MAGNETOM Sola Fit Category: Optional feature Pre-requisites: None Note: TSE is supported with the exception of BLADE TSE Deep Resolve Sharp is a novel image reconstruction Deep Resolve sharp can be used to reduce acquisition technology that increases sharpness in the resulting times: Images can be acquired with reduced phase images. The deep neural network at the core of Deep resolution; the resolution can then be recovered when Resolve Sharp generates a high-resolution image from reconstructing the images with Deep Resolve Sharp. low resolution input data. The network was trained on a large number of pairs of low-resolution and New benefits: high-resolution data. As the training data for Deep • Resolve Sharp covered a wide range of anatomies, Deep Resolve Sharp now supports TSE Dixon and the reconstruction network can be applied to all body conventional Spin Echo • regions. Deep Resolve Sharp can increase the matrix Deep Resolve Sharp is now compatible with SMS TSE size by a factor of up to two along both in-plane axes, resulting in substantially increased image sharpness. 11 syngo MR XA platform – XA51A E A 2.3 Breast Biopsy improvements (detection of fiducial markers) Available for: MAGNETOM Sola, MAGNETOM Altea and MAGNETOM Sola Fit Category: Included with Breast Biopsy software license Pre-requisites: Breast Biopsy software license, Breast Biopsy Coil and Grid- or Post&Pillar-Device and Fiducial Marker This functionality supports the breast biopsy user by New benefits: automatically selecting the fiducial marker. After the automatic selection, you can approve the selected The automatic detection of the fiducial markers provides marker. The marker is then highlighted with a yellow an improved breast biopsy workflow, which can be arrow in the images. performed faster as the user does not need to manually select the fiducial marker by scrolling/navigating through all the images. Device Settings ? X Presets BI4 Kit1 Grid Name B17 Grid BI4 Kit2 PP (*) BI7 Grid Coil Breast BI 7 BI7 PP Intervention Method Grid Marker Position CA Needle ATEC Petite 9g Automatic Marker Detection on Markers to detect 1 · Lateral . Medial Copy Delete OK Apply Cancel The automatic f iducial marker detection can be activated in the Device Settings pre-configuration dialogue. MR Breast Biopsy Ca + Anonymous Female 1967 MR Breast Biopsy ANONPPO11E1LG F. 51Y MR B19 Calibration CURRENT HFP 29.06.2019 Device B17 Grid (AF2) 11_f13d_ax DYNAMIC NON FATSAT latest/Phase_02 Markers 1 Left Later ... # RPPO11E1KG STUDY ID EPPO11E1KG 15:12:16 Breast Left IMA 92 M (C4) Access Direction Lateral Skin Edge L133 R 1 cm Skin Edge 20 1.2 F SL Approve TR 7,0 TP O TE 4,8 SP H52,5 Target Selection FoV 250*250 BW 610,0 192*256 MIND/NORM Tra Zoom 2,02 A1/PFP W 876 *113d1 /10 C 414 Dotarem After automatic detection of the fiducial marker, the marker is displayed and labeled in the “Markers” field. The approved marker is also highlighted with a yellow arrow in the image. 12 syngo MR XA platform – XA51A E A 2.4 Motion Correction for TSE with more than a single average Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None Note: Not compatible with Deep Resolve Boost TSE motion correction is an image-based motion New benefits: correction technique in the average-dimension for TSE imaging. The motion correction technique employs a The motion correction in the average dimension reduces non-rigid elastic registration to consistently align the the image blur that would result from organ movement images before averaging. The feature has been optimized between averages. and validated for improved prostate TSE imaging. 0 2:57 min | Auto @ 3 0.3x0.3x3.0 mm3 1.00 Routine Contrast Resolution Geometry System Physio Inline Sequence Part 1 Part 2 Assistant Introduction v WARP Phase Correction Automatic Red. EC Sensitivity Compensate T2 Decay Acoustic noise reduction Off Hyperecho Reduce Motion Sens. Motion Correction None None Registration of Averages The TSE motion correction functionality can be activated in the UI element “Motion Correction” through the option “Registration of Averages”. This functionality is only selectable if multiple averages are selected. 13 syngo MR XA platform – XA51A E A 2.5 GSP: Toolbar pinning Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None The Graphical Slice Positioning (GSP) user interface (UI) New benefit: is the central workplace when planning and conducting an exam. When using the Toolbar of the GSP, there GSP Toolbar can be pinned on systems starting with was no way to pin it. With syngo MR XA51A, the syngo MR XA51A. possibility to pin the Toolbar has been added to the GSP UI. SIEMENS .. i Toolbar pinning, Demo X Healthineers * 7/24/1981 M 2021. 10. 14-10:08:24 ... MR View&GO Brain LOC AFR AFR AFR Toolbar pinning, Demo Toolbar pinning, Demo Toolbar pinning, Demo AAhead_scout 2021.10.14-10:08:24-DST-1.3.12.2.1107.5.99.3 2021.10.14-10:08:24-DST-1.3.12.2.1107.5.99.3 2021.10.14-10:08:24-DST-1.3.12.2.1107.5.99.3 10/1 4/2021 10/1 4/2021 10/1 4/2021 t1_f12d_sag_p2_256 5 IMA 1 FRM 1/1 5 IMA 1 FRM 1/1 5 IMA 1 FRM 1/1 t2_tse_tra_p3_256 & t2_tse_dark-fluid_tra_p2_256 5 % ep2d_diff_mddw_12_p2 6 ep2d_tra_hemo 00:06 RPH RPH F F TP O TP 0 SP F24.3 SP F24.3 SP F24.3 IMPRIRESAMPINORMIDIS 3D FoY 259*259 FoV 259*259 JMPRIRESAMP/NORM/DIS3D FoV 259*259 AAhead_scout_MPR_tra Cor(9)>Sag(-1) .. IMPR/RESAMP/NORM/DIS3D Tra>Cor(9)>Sag(-1) >Cor(9)>Sag(-1) 576 AAhead_scout_MPR_tra W 576 274 AAhead_scout_MPR_tra 576 274 274 01:12 Cancel 1:52 min 1 Auto @ 2 @ 0.9x0.9x5.0 mm3 1.00 Copy&Go GO Routine Contrast Resolution Geometry System Physio Inline Sequence Slice Group 1 FoV Read 220 - mm Slices 25 OV Phase 87.5 % Slice Thickness 5.0 + mm Distance Factor 20- TR 8000.0 + ms Position Isocenter TE 119.00 m Orientation Transversal Average Phase Encoding Dir. R>> L Concatenations Phase Oversampling 25 + % AutoAlign Head > Brain Coil Elements HC2 SAR Stimu settings myExam actor FIRST Normal Waiting for slice positionin 10:09:46 AM Regular user interface in syngo MR XA51A. The toolbar is hidden and can be activated by clicking the white downwards oriented triangle above the three localizer images in the center. 14 syngo MR XA platform – XA51A E A SIEMENS .. Toolbar pinning, Demo * 7 124/ 1981 M 2021 10 14 - 10 : 08 : 24 ... X Healthineers .... MR View&GO 2 Brain LOC ID + Saturat Graphies Package Image Coils Table Line vondi AAhead_scout 10/1 4/2021 t1_f12d_sag_p2_256 5 IMA 1 FRM 1/1 10/1 4/2227 5 IMA 1 FRM 1/ 10/1 4/2021 5 IMA1 FRM 1/1 t2_tse_tra_p3_256 & t2_tse_dark-fluid_tra_p2_256 5 % ep2d_diff_mddw_12_p2 6 ep2d_tra_hemo 00:06 RPH RPH F F F TP O TP O TP 0 SP F24.3 SP F24.3 SP F24.3 FoV 259-259 FoV 259*259 FoV 259*259 IMPRIRESAMPINORMIDIS3D AAhead_scout M or(9)>Sag(-1) JMPRIRESAMP/NORM/DIS3D a>Cor(9)>Sag(-1) >Cor(9)>Sag(-1) W ... IMPR/RESAMP/NORM/DIS3D C 576 W 576 274 AAhead_scout_MPR_tra 576 274 AAhead_scout_MPR_tra 274 2 01:12 Pause Continue Copy&Go GO Cancel Ò 1:52 min " in 4 Auto @ 2 0.9x0.9x5.0 mm3 1.00 Routine Contrast Resolution Geometry System Physio Inline Sequence Slice Group 1 -oV Read 220 - mm Slices 25 FOV Phase 87.5 % Slice Thickness 5.0 - mm Distance Factor 20 8000.0 + ms Position Isocenter TE 119.00 - ms Orientation Transversal Average Phase Encoding Dir. R>> L Concatenations Phase Oversampling 25 + % AutoAlign Head > Brain Coil Elements HC2 O mybom SAR Stimu Norma Waiting for slice positioning 10:10:55 AM After the triangle has been clicked, the toolbar opens. Please note on the far-right side the small pin next to the settings wheel. SIEMENS Healthineers Toolbar pinning, Demo X x * 7 124/1981 M 2021 . 10 . 14 - 10 : 08 : 24 .. 41001 CH MR View&GO * Brain LOC & D + + AFR AFR AFR AAhead_scout T 2021.10.14-10-08-24-DST-1.3.12.2.11 07.5.99.3 2021.10.14-10-08-24-DST-1.3.12.2.1107.5.99.3 Toolbar pinning, Demo 2021.10.14-10:08:24-DST-1.3.12.2.1107.5.99.3 2 t1_f12d_sag_p2_256 10/1 4/2021 5 IMA 1 FRM 1/1 5 IMA 1 FRM 1/1 10/1 4/2021 5 IMA 1 FRM 1/1 3 t2_tse_tra_p3_256 4 % t2_tse_dark-fluid_tra_p2_256 ep2d_diff_mddw_12_p2 01:06 6 ep2d_tra_hemo 00:06 RPH RPH 5cm 5cm 5cm F F TP 0 TP 0 TP 0 SP F24.3 SP F24.3 SP F24.3 APRIRESAMP/NORM/DIS3D FoV 259+259 FoV 259*259 Ahead_scout-MPR_tra Cor(9)>Sag(-1) ... /MPR/RESAMP/NORM/DIS3D a>Cor(9)>Sag(-1) IMPRIRESAMP/NORM/DIS3D FoV 259*259 Cor(9)>Sag(-1) 576 C 274 AAhead_scout-MPR-tra w 576 AAhead Scott ORMIDIS 576 274 2 01:1 copy&Go Go Cancel $1:52 min Auto @ 2 0.9x0.9x5.0 mm3 1.00 Routine Contrast Resolution Geometry System Physio Inline Sequence Slice Group 1 FOV Read 220 - mm Slices 25 + FoV Phase 87.5 4 % Slice Thickness 5.0 ¢ mm Distance Factor 20 TR 8000.0 + ms Position Isocenter TE 119.00 ¢ ms Orientation Transversal Average 1 + Phase Encoding Dir. R>> L Concatenation Phase Oversampling 25 AutoAlign Head > Brain Coil Elements HC2 SAR Stimu settings Settings myExam lector First Normal Level Mode Waiting for slice positioning 10: 11:25 AM After clicking the pin, the background of the pin turns to a light gray and the orientation of the pin changes from horizontal to downwards tilted. The Toolbar is now pinned and, hence, the tools are always visible in the UI. 15 syngo MR XA platform – XA51A E A 2.6 GSP: Center line for scan planning Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None When modifying the slice or slab group orientation in the slice orientation is perpendicular to your planning 2D or 3D scanning, a dashed line along the slice/slab image plane, e.g., if you plan a sagittal slice stack on a direction is displayed. This center line is designed to sagittal image. facilitate precise positioning along anatomical structures such as the brainstem, spinal cord, septal wall etc. As New benefits: soon as the user releases the mouse button, the center • line disappears for clear visualization of the underlying Center line along slice direction for precise positioning anatomy. Please note that no center line is displayed if along anatomical structures • Available for 2D and 3D imaging SIEMENS Centerline, Demo x X Healthineers * 7124/1981 M 2021.10.14-09:26:00 ... MR View&GO Brain LOC HPL Centerline, Demo Centerline, Demo AAhead_scout 2021.10.14-09:26:00-DST-1.3.12.2-1107.5.99.3 2021.10.14-09:26:00-DST-1.3.12.2.1107.5.99.3 10/1 4/2021 10/14/2021 t1_f12d_sag_p2_256 4 IMA 1 FRM 1/1 4 IMA 1 FRIK 1/1 %_ 12_tse_tra_p3_256 4 t2_tse_dark-fluid_tra_p2_256 01:52 5 ep2d_diff_mddw_12_p2 01:06 6 ep2d_tra_hemo 00:06 SP LO.2 ESAMPINORMDIS3D FOV 259-259 AAhead_scout MPR_sag Sag.Cor(5) . Tra(2) 534 IMPRIRE SAMP/NORMDIS3D M8 AAhead_scout_MPR_sap 2 03:04 Un Cancel & 1:02 min Auto2 3 @ 0.9x0.9x5.0 mm3 Routine Contrast Resolution Geometry System Physlo Inline Sequence When modifying the orientation of the slice group for 2D imaging, a dashed white line along the slice direction through the pivot (yellow circle in the center of the slice group) appears. SIEMENS .. Centerline, Demo X Healthineers 7 - 7/24/1981 M 2021.10.14-09:26:00 ... MR View&GO ? Brain LOC + HPL HPL Centerline, Demo Centerline, Demo AAhead_scout 2021.10.14-09:26.00-DST-1.3.12.2.1107.5.99.3 2021.10.14-09:26.00-DST-1.3.12.2.1107.5.99.3 2021.10.14-09:26:00-DST-1.3.12.2.1107.5.99.3 10/14/2021 10/1 4/2021 10/14/2021 t1_f12d_sag_p2_256 4 IMA 1 FRMM 1/1 4 IMA 1 FRM 1/1 4 IMA 1 FRMK 1/1 3 %_ 12_tse_tra p3_256 4 t2_tse_dark-fluid_tra_p2_256 01:52 5 ep2d_diff_mddw_12_p2 01:06 6 ep2d_tra_hemo 00:06 SP LU.2 SP 12 .IMPRIRE SAMP/NORM/DIS3D FOV 259.259 FOV 259-259 AAhead_scout_MPR_sag Cor(5) -Tra(2) IMPRIRESAMPINORM/DIS3D Sag.Cor(5) .Tra(2) IMPRIRE SAMP/NORMDIS30 FoV 259 259 g.Cor(5) -Tra(2) 534 $34 C HC1 248 AAhead_scout_MPR_sag C HCI 2448 MAhead_scout MAPR_sap Hc534 248 E 03:04 Un Un Go Cancel & 1:02 min 4 Auto2 3 @ 0.9x0.9x5.0 mm) 1.00 Routine Contrast tesolution Geometry System Physio Inline Sequence No center line is visible when the mouse button is released. 16 syngo MR XA platform – XA51A E A 2.7 Transition of Dot Engines to myExam Companion Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard and optional features Pre-requisites: None With syngo MR XA51A, the Dot engines will move under brand name. On the MAGNETOM scanners running on the umbrella of the Siemens Healthineers myExam syngo MR XA51A, myExam Companion will feature the Companion. This will harmonize tools facilitating easier “Dot engines” as “myExam Assist” or simply “Assist”; the workflow across different modalities under one common former “Dot Cockpit” becomes the “myExam Cockpit”. Overview of new names: Previous naming New naming with syngo MR XA51A Dot Engines myExam Assist Brain Dot Engine myExam Brain Assist Spine Dot Engine myExam Spine Assist Large Joint Dot Engine myExam Large Joint Assist Abdomen Dot Engine myExam Abdomen Assist Whole-body Dot Engine myExam Whole-Body Assist Breast Dot Engine myExam Breast Assist Angio Dot Engine myExam Angio Assist Cardiac Dot Engine myExam Cardiac Assist RT Dot Engine myExam RT Assist LiverLab Dot Engine myExam LiverLab Assist As additional stand-alone option w/o Abdomen Assist Prostate Dot Engine myExam Prostate Assist Dot Cockpit myExam Cockpit 17 syngo MR XA platform – XA51A E A 2.8 Improvements to Simultaneous Multi-Slice TSE imaging Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Included with SMS license Pre-requisites: SMS license SMS TSE imaging can suffer from distinct ghosting New benefit: artifacts that can compromise image quality. These ghosting artifacts are residual fat signal. The root cause Reduction of ghosting artifacts results in improved image is the difference in the resonance frequencies between quality for SMS TSE. fat and water. With syngo MR XA51A the induced phase shift of the blip gradients in the SMS TSE sequence has been optimized, resulting in an effective reduction of fat-related ghosting artifacts. 2.9 Faster image reconstruction in Simultaneous Multi-Slice imaging Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Included with SMS license Pre-requisites: SMS license In rare cases, users running high resolution matrix sizes New benefits: in conjunction with SMS imaging ran into memory • issues with their MaRS. With syngo MR XA51A, data Reconstruction of highly resolved SMS imaging data processing has been optimized such that these memory should not lead to memory problems • problems should no longer occur. As a side effect, SMS Faster image reconstruction due to optimized data reconstruction times can be reduced by up to a factor processing of two. 18 syngo MR XA platform – XA51A E A 2.10 Improved RESOLVE diffusion imaging in the breast Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None In rare cases, when applying RESOLVE diffusion imaging New benefit: in the breast with arms down, signal drops could be visible. With syngo MR XA51A, the calculation of the Rare signal drops in RESOLVE breast imaging are avoided. ghost correction factors has been refined such that erroneous results are now avoided. 2.11 Improvements for radial planning Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None “Radial Slices” allows a calculation of radial layers on the Routine Contrast Resolution Geometry System Physio Inline Sequence basis of the selected slice group with their perpendicular Coils Miscellaneous Adjustments Adjust Volume Tx/Rx axis rotated around the image. For example, for an Coil Selection Auto Coil Select ... Coll Combination Adaptive Combine accurate assessment of hip joints. Radial Sorting New benefit: MSMA S-C-T Matrix Optimization Off Sagittal R>>L The display of the slices created by the Radial Slices Coronal A>> P function is now clockwise when radial sorting is Transversal F>>H activated. 19 syngo MR XA platform – XA51A E A 2.12 Improvements of SAR Assistant Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None syngo MR XA51A introduces another parameter to the New benefits: SAR Assistant: The RF Pulse Type. This value is now available in addition to TR and flip angle for resolving This makes the adjustment of scan values for SAR SAR limitations. sensitive examinations even more flexible. USER >> New Region >> New Exam >> New Program >> BEAT ? X General 8 8 sec Auto @ None @ 2.3x2.3x10.0 mm3 ~ 1.00 Protocol Parameters Routine Contrast Resolution Geometry System Physio nline Sequence Voice Commands Execution Part 1 Part2 Assistant Image Management SAR Assistant TR > Flip Angle Optimization Min. TE Auto Load Min Flip Angle Off Copy References Flip Angle Preview Max. TR Flip Angle > TR Allowed Delay Flip Angle > TR > RF Pulse Type Flip Angle > RF Pulse Type Flip Angle > RF Pulse Type > TR TR TR > Flip Angle TR > Flip Angle > RF Pulse Type TR > RF Pulse Type TR > RF Pulse Type > Flip Angle RF Pulse Type RF Pulse Type > Flip Angle RF Pulse TvDe > Flip Anale > TRY 20 syngo MR XA platform – XA51A E A 2.13 Improvement of graphics handling – DICOM interoperative mode Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None Display of additional graphics (such as spine labeling) New benefits: on MR images in PACS systems. On the MR scanner created graphics can be easily recognized, transferred, and used as regular MR images in the PACS system. This makes it easier to include them in the reporting. A › A E Spine labelling in localizer at the MR system Spine labelling in localizer at the PACS system 21 syngo MR XA platform – XA51A E A 2.14 Multi Environment Profiles Available for: MAGNETOM Sola, MAGNETOM Altea, MAGNETOM Sola Fit Category: Standard feature Pre-requisites: None By introducing Multi Environment Profiles, the admin New benefits: user can set up different profiles. These profiles can • contain institution names as well as default Radiology Available for systems that are shared by different Information System (RIS) and Picture Archiving and institutions • Communication System (PACS) settings associated with Contains RIS and PACS information relevant for the that institution. This enables a simpler change of the respective institution • user preferences for RIS and PACS at systems that are The admin user can create, modify and delete Multi shared by different institutions. Besides the possibility Environment Profiles • to switch between profiles in the admin user account, The admin user can switch between Multi Environment a technologist user can be defined that is only allowed Profiles, thereby propagating the associated RIS and to switch between the different Multi Environment PACS settings for the respective institution • Profiles. A technologist user can be defined who is only allowed to switch between Multi Environment Profiles, thereby propagating the associated RIS and PACS settings for the respective institution. This circumvents the necessity to have an admin user performing this profile change MAGNETOM Vida Administration Portal SIEMENS leolthineers NXVSIM / medadmin Free (Restricted Remote Access) Installation ₭º Technical Configuration Quality Assurance Clinical Configuration Site Information Environment Profiles Environment Profiles Remote Service Current loaded profile: Radiology - Department for Diagnostic and Caution: Switching profiles during scanning may cause inconsistency Licensing Interventional Radiology in the acquired data User and Role Administration DICOM Nodes DICOM Data Handling Save the current configuration as a New Profile Auditing to Syslog Server Automatically save the current profile when activating other Neuroradiology Department for Neuroradiology Activate Rename Update Delete Profile 2021-12-15 13:48:40 Radiology Department for Diagnostic and Interventional Radiology Activate Rename Update Delete Profile 2021-12-15 13:49:04 In the admin portal, a new “Environment Profiles” option is now available. Here, the admin user can create profiles referring to different institutions that share the same MR scanner. 22 Siemens Healthineers AG (listed in Frankfurt, Germany: The outcomes and statements provided by customers SHL) pioneers breakthroughs in healthcare. For everyone. of Siemens Healthineers are unique to each customer’s Everywhere. As a leading medical technology company setting. Since there is no “typical” hospital and many headquartered in Erlangen, Germany, Siemens variables exist (e.g., hospital size, case mix, and level of Healthineers and its regional companies is continuously service/technology adoption), there can be no guarantee developing its product and service portfolio, with that others will achieve the same results. AI-supported applications and digital offerings that play an increasingly important role in the next On account of certain regional limitations of sales rights generation of medical technology. These new and service availability, we cannot guarantee that all applications will enhance the company’s foundation products included in this brochure are available through in in-vitro diagnostics, image-guided therapy, in-vivo the Siemens Healthineers sales organization worldwide. diagnostics, and innovative cancer care. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the Siemens Healthineers also provides a range of services features and products described herein may not be and solutions to enhance healthcare providers’ ability to available in the United States. provide high-quality, efficient care. In fiscal 2021, which ended on September 30, 2021, Siemens Healthineers, The information in this document contains general which has approximately 66,000 employees worldwide, technical descriptions of specifications and options as generated revenue of €18.0 billion and adjusted EBIT well as standard and optional features, which do not of €3.1 billion. always have to be present in individual cases. Further information is available at Siemens Healthineers reserves the right to modify the www.siemens-healthineers.com. design, packaging, specifications, and options described herein without prior notice. For the most current information, please contact your local sales representative from Siemens Healthineers. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. Siemens Healthineers Headquarters USA Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Healthcare 91052 Erlangen, Germany 40 Liberty Boulevard siemens-healthineers.com Malvern, PA 19355-9998, USA siemens-healthineers.us Published by Siemens Medical Solutions USA, Inc. · Order No. MR-22-NAM-3826 · HOOD05162003307903 · 09.2022 · ©Siemens Medical Solutions USA, Inc., 2022
- xa51
- mr51