This job aid, reviews workflow steps to compose or combine images with multiple table moves.
Applicable for Numaris X XA60 software and up.
MR View&GO – Compose/Combine Numaris X Job Aid syngo MAGNETOM MR Systems with Numaris X software Perform composing to create composite images for sagittal and coronal images. There are several algorithms available that are based on the image type. (e.g., Spine, Angio, and Maximum Inten- sity Projection (MIP) images). 1. Load a Study that uses the Tim Planning Suite (i.e., with multiple table moves) into MR View&GO. 2. In the Viewing area of MR View&GO, select all Series for Compose/Combine (Ctrl + left-click). 3. Favorite Tools area, select Compose/Combine icon. Compose is for the Sagittal/Coronal planes. Favorite Tools X • 3D • Combine is for the Axial plane. Show in TimeCurve ADC & Compose/ 3D value Combine 4. In the Create New Composition window, confirm that All Series selected are loaded into the Selected Series area. If not, left-click on the sequence needed and click on the Arrow to move to the Selected Se- ries list. Create New Composition X Selected Series Available Series Whole Spine_Sag T2 3D Upper.latest Whole Spine_Sag T2 3D Lower.latest Composing Algorithm Spine algorithm Name Of Composed Series OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 3 DEC 2023 | QR700002996 Healthineers 5. Select the Composing Algorithm from the drop-down list. • Spine is based on bone structure, for composing spine images. • Angio is based on vessel structure, to compose an overview of vessels. • MIP is based on composing Maximum Intensity Projection (MIP) images. • Adaptive is based on elastic matching, to correct B0-induced inhomogeneities in image areas beyond the magnetic homogeneity volume. Composing Algorithm Spine algorithm Spine algorithm Name Of Composed Series Angio algorithm Mip algorithm Adaptive algorithm 6. Enter the series name in the Name of Composed Series field. Composing Algorithm Spine algorithm Name Of Composed Series Whole Spine Sagittal T2 Composed 7. Click OK. Composing begins. Composing Algorithm Spine algorithm Name Of Composed Series Whole Spine Sagittal T2 Composed OK Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 3 DEC 2023 | QR700002996 Healthineers Page 2 of 4 8. Series composes and provides a preview for adjusting and/or saving the data. MR View&GO HR MR View&GO View&GO Dataset Stack 342 Stack 2x2 Stock 123456789 View&GO Dataset MAGNETOM Altea Siemens Healthineers "1/28/1991, M, 30Y MAGNETOM Aera syngo MR XA60 123456789 1/28/1991. M. 30Y MAGNETOM Altea 1/28/2021 HFS MAGNETOM Aera syngo MR XA60 Results Whole Spine Sagittal T 2 Composed COMP +LPH 1/28/2021 HFS 9934565d-ba3c-419b-919a-aa 94 +LPH Results Whole Spine Sagittal T2 Composed_COMP 12:24:02 PM Favorite Tools - Composer X 9934565d-ba3c-419b-9f9a-aa9499520e 2f 1006 IMA 1 FRM 48/95 STUDY ID cd328ed3-1ea6-45 Confirm 12:34:02 PM 1006 IMA 1 FRM 48/95 Results Whole Spine Sagittal 12 Com Series Normalize TAL SL 0.7 10 cm Printing Favorite Tools × 3D Show in TimeCurve ADC & b- Composel Image CE value Combine Sorting TR 1200.0 EB TE 160.0 SP R7.0 TA 03:46 FoV 705*305 Position Snapshot Print Stack BW 481.0 1080*832s | RR p7.0 MAGN/M/COMP_SP/DIS2D/SH5_3/FIL/MFSPLIT Sag>Cor(-1)>Tra(-1) TR 1200.0 TE 160.0 SP R7.0 A2/SAT1 Zoom 0.49 TA03:46 FoV 705*305 Mosaic Subtracti ... BY1,2;HE3.4; NE1,2;SP1,2 W 574 BW 481.0 1080*832s | p7.0 MAGN/M/COMP_SP/DIS2D/SH5_3/FIU ... Sag>Cor(-1)>Tra(-1) *spcR_100 / 125 C 252 A2/SAT1 Zoom 0.46 BY1,2;HE3,4 NE1,2;SP1,2 574 SPINE Q - Score : 42 *spcR_100/ 125 SPINE C 252 + Q - Score : 42 9. Adjust the Series using the tools in the Composer Series Navigator. • Blend/Cut Mode icon, switches between soft transitions (smooth image transition) and hard cuts (shows the original image borders). • Normalize icon, harmonizes different grayscale values for a homogeneous overview. • Manual Adjust icon, opens an alignment mini toolbar to manually align the original images. auto Blend/Cut Normalize Manual Mode Adjust 10. To save composed/combined images, click the Confirm Result icon in the Composer Series Navigator to save the series. Composer X 1/28/2021 9:42 PM MR, View&GO Dataset 40 New New Confirm 14 Whole Spine_Sag T2 3D Upper Compose Combine Result 15 Whole Spine Sag 12 3D Lower 10 ... : Results Whole Spine Sagittal T ... Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 3 DEC 2023 | QR700002996 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Henkestr. 127 91052 Erlangen, Germany 40 Liberty Blvd. Magnetic Resonance Phone: +49 9131 84-0 Malvern, PA, USA 19355-9998 Henkestr. 127 siemens-healthineers.com Telephone: +1-888-826-9702 DE-91052 Erlangen, Germany siemens.com/healthcare Telephone: +49 9191 18-0 siemens.com/healthcare Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 3 DEC 2023 | QR700002996 Healthineers Page 4 of 4
- planning suite
- compose
- combine