MR View&GO - Compose/Combine (XA40)
This job aid reviews the workflow steps to compose or combine images that have multiple table moves.
MR View&GO: Compose & Combine Job Aid MAGNETOM Free.Max (XA40); syngo MR Systems 1. From MR View&GO, select series for composing (Ctrl + Left-Click). 2. In Favorite Tools, select the Compose/Combine icon. Favorite Tools × 3D Show In Timecurve ADCE Comporel 30 Combina 3. Select Create New Composition or Create New Combining window. 4. Confirm that all intended Series are in the Selected Series box. 5. If all Series are not in Selected Series box, select from Available Series and click-arrow to move. Create New Composition Create New Combining Selected Series Available Series Selected Series Available Series t1_tse_sag_p2_B.latest t2_tse_stir_sag_p2.latest t1_Ise_sag_p2_A.latest t2_Ise_sag_p2.latest t2_tse_tra_B.latest t2_tse_tra_RR.latest t2_tse_stir_sag.latest t2_tse_sag_p2_SC.latest Composing Algorithm Angio algorithm Name Of Composed Series Composed Spinel Name Of Combined Series Combined Transverse Spine OK Cancel OK Cancel Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252796 Healthineers 6. Select Composing Algorithm (only for composing). • Spine – based on bone structure for spine images • Angio – based on vessel structure • MIP – optimized for Compose MIP images • Adaptive – based on elastic matching, corrects BO induced inhomogeneities in image areas Composing Algorithm Angio algorithm Spine algorithm Name Of Composed Series Angio algorithm Mip algorithm Adaptive algorithm 7. Enter Name of Composed/Combined Series. Name Of Composed Series Composed Spine Name Of Combined Serles Combined Transverse Spine 8. Click OK. Composing starts. OK Cancel Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252796 Healthineers Page 2 of 4 9. Series composes and provides a preview to adjust and/or save data. MR View&GO MR View&GO 1/1/1 996, 1, 25Y Stack 3a2 Stack 2x2 Stack 5x4 1/1/1996. M. 25Y 3/23/2021 CURRENT 3/23/2021 1010 IN44 1 FRM 89 6 Favorite Tools · Composer :27:17 PM 10 10 IMA 1 FRM 8/16 Confirm Compose Combine Results Composed Spine_COMP saluas SEC 4.0 -2 V 0cm Supund Favorite Tools X 3D o Show in TimeCurve ADC & b Compocel Combine DE Fit la Segment Snapshot Print Stack A FIp TR 4000.0 Horizontal FMIFILICOMP_AN DIS2D Zoom O L SP LO.2 FoV 542 352 NIFINTILICOMP ANDIS20 Zoom 0.51 ANGIO 10. Adjust series in Composer Tools window (only for composing). • Blend/Cut Mode – switches between soft transitions (for smooth transitions and hard cuts, shows original image borders) • Normalize – harmonizes different grayscale values for a homogeneous overview • Manual Adjust – enables manual alignment of original images auto Blend/Cut Normalize Manual Mode Adjust 11. Save Composed/Combined images. 12. Select Confirm Result icon in Composer Series Navigator to save series. Composer × 32 t1 tse sag p2 B t2 tse sur saq_p2 New New Confirm Compose Combine Result 10 ... A Results Composed Spine COMP Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252796 Healthineers Page 3 of 4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Imaging & Therapy Systems Henkestr. 127 91052 Erlangen, Germany 40 Liberty Blvd. Magnetic Resonance Phone: +49 9131 84-0 Malvern, PA, USA 19355-9998 Henkestr. 127 siemens-healthineers.com Telephone: +1-888-826-9702 DE-91052 Erlangen, Germany siemens.com/healthcare Telephone: +49 9191 18-0 siemens.com/healthcare Unrestricted | Published by Siemens Healthcare GmbH “ Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2022 | HOOD05162003252796 Healthineers Page 4 of 4
- MRI compose
- MR post processing
- post-process MR
- MR table